{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,14]],"date-time":"2026-08-14T18:03:32Z","timestamp":1786730612401,"version":"build-2736575974"},"reference-count":12,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,4,1]],"date-time":"2025-04-01T00:00:00Z","timestamp":1743465600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,3,6]],"date-time":"2025-03-06T00:00:00Z","timestamp":1741219200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinica Chimica Acta"],"published-print":{"date-parts":[[2025,4]]},"DOI":"10.1016\/j.cca.2025.120224","type":"journal-article","created":{"date-parts":[[2025,3,5]],"date-time":"2025-03-05T16:51:19Z","timestamp":1741193479000},"page":"120224","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["A new pitfall in potassium testing: A case series of false elevation of hemolysis index in the presence of monoclonal protein"],"prefix":"10.1016","volume":"571","author":[{"given":"Cl\u00e9ment","family":"Capaldo","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Richard","family":"Eveillard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"H\u00e9l\u00e8ne","family":"Kerspern","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jean-Christophe","family":"Ianotto","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cyril","family":"Leven","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.cca.2025.120224_b0005","doi-asserted-by":"crossref","first-page":"718","DOI":"10.1515\/cclm-2017-1104","article-title":"Practical recommendations for managing hemolyzed samples in clinical chemistry testing","volume":"56","author":"Lippi","year":"2018","journal-title":"Clin. Chem. Lab. Med."},{"issue":"1","key":"10.1016\/j.cca.2025.120224_b0010","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/10408363.2019.1664391","article-title":"Managing hemolyzed samples in clinical laboratories","volume":"57","author":"Simundic","year":"2020","journal-title":"Crit. Rev. CL Lab. Sci."},{"key":"10.1016\/j.cca.2025.120224_b0015","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.clinbiochem.2021.01.001","article-title":"Hydroxocobalamin interference in routine laboratory tests: development of a protocol for identifying samples and reporting results from patients treated with cyanokittm","volume":"91","author":"Dang","year":"2021","journal-title":"Clin. Biochem."},{"key":"10.1016\/j.cca.2025.120224_b0020","doi-asserted-by":"crossref","first-page":"527","DOI":"10.1177\/0004563216643557","article-title":"Serum indices: managing assay interference","volume":"53","author":"Farrell","year":"2016","journal-title":"Ann. Clin. Biochem."},{"key":"10.1016\/j.cca.2025.120224_b0025","doi-asserted-by":"crossref","DOI":"10.1016\/j.cca.2024.119917","article-title":"Cherry-red plasma: beyond the assumption of hemolysis","volume":"564","author":"Chen","year":"2025","journal-title":"Clin. Chim. Act."},{"key":"10.1016\/j.cca.2025.120224_b0030","doi-asserted-by":"crossref","first-page":"1062","DOI":"10.1373\/jalm.2018.028456","article-title":"The lipemia index: an underutilized tool to detect monoclonal proteins","volume":"3","author":"Agrawal","year":"2019","journal-title":"J. Appl. Lab. Med."},{"key":"10.1016\/j.cca.2025.120224_b0035","doi-asserted-by":"crossref","first-page":"352","DOI":"10.11613\/BM.2012.037","article-title":"Investigation of unusual high serum indices for lipemia in clear serum samples on siemens analysers dimension","volume":"22","author":"Fliser","year":"2012","journal-title":"Biochem. Med."},{"key":"10.1016\/j.cca.2025.120224_b0040","doi-asserted-by":"crossref","first-page":"258","DOI":"10.11613\/BM.2021.020703","article-title":"Utility of icteric index in clinical laboratories: more than a preanalytical indicator","volume":"31","author":"Mondejar","year":"2021","journal-title":"Biochem. Med."},{"key":"10.1016\/j.cca.2025.120224_b0045","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1179\/acb.2004.039","article-title":"Protein precipitation as a possible important pitfall in the clinical chemistry analysis of blood samples containing monoclonal immunoglobulins: 2 case reports and a review of the literature","volume":"5","author":"Berth","year":"2004","journal-title":"Acta Clin. Belg."},{"key":"10.1016\/j.cca.2025.120224_b0050","doi-asserted-by":"crossref","unstructured":"L. Thouault, C. Leven, JR. Eveillard, K. Kerspern, E. Pl\u00e9e-Gautier, JC. Ianotto JC, JL. Carre, C. Capaldo, Assessment of the lipemia index determined by the Atellica CH 930 analyzer for the detection of monoclonal immunoglobulins.Clin. Chem. Lab. Med. 62 (2024) e68\u2013e71. DOI: 10.1515\/cclm-2023-0872.","DOI":"10.1515\/cclm-2023-0872"},{"key":"10.1016\/j.cca.2025.120224_b0055","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1093\/clinchem\/hvae065","article-title":"Problematic proteins: a patient with a high paraprotein concentration","volume":"70","author":"Hortin","year":"2024","journal-title":"Clin. Chem."},{"key":"10.1016\/j.cca.2025.120224_b0060","doi-asserted-by":"crossref","first-page":"1329","DOI":"10.1515\/cclm-2015-0608","article-title":"Analytical interference by monoclonal immunoglobulins on the direct bilirubin AU Beckman Coulter assay: the benefit of unsuspected diagnosis from spurious results","volume":"54","author":"Garc\u00eda-Gonz\u00e1lez","year":"2016","journal-title":"Clin. Chem. Lab. Med."}],"container-title":["Clinica Chimica Acta"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009898125001032?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009898125001032?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,6,12]],"date-time":"2025-06-12T12:19:53Z","timestamp":1749730793000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0009898125001032"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,4]]},"references-count":12,"alternative-id":["S0009898125001032"],"URL":"https:\/\/doi.org\/10.1016\/j.cca.2025.120224","relation":{},"ISSN":["0009-8981"],"issn-type":[{"value":"0009-8981","type":"print"}],"subject":[],"published":{"date-parts":[[2025,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A new pitfall in potassium testing: A case series of false elevation of hemolysis index in the presence of monoclonal protein","name":"articletitle","label":"Article Title"},{"value":"Clinica Chimica Acta","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.cca.2025.120224","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"120224"}}