{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T12:06:46Z","timestamp":1790856406386,"version":"4.1.0"},"reference-count":62,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2018,11,1]],"date-time":"2018-11-01T00:00:00Z","timestamp":1541030400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2018,11,1]],"date-time":"2018-11-01T00:00:00Z","timestamp":1541030400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal.chestnet.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Chest"],"published-print":{"date-parts":[[2018,11]]},"DOI":"10.1016\/j.chest.2018.04.045","type":"journal-article","created":{"date-parts":[[2018,5,30]],"date-time":"2018-05-30T22:04:36Z","timestamp":1527717876000},"page":"1024-1034","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":81,"title":["Effectiveness of Reprocessing for Flexible Bronchoscopes and Endobronchial Ultrasound Bronchoscopes"],"prefix":"10.1016","volume":"154","author":[{"given":"Cori L.","family":"Ofstead","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mariah R.","family":"Quick","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Harry P.","family":"Wetzler","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John E.","family":"Eiland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Otis L.","family":"Heymann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David A.","family":"Sonetti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"J. Scott","family":"Ferguson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"9","key":"10.1016\/j.chest.2018.04.045_bib1","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1164\/rccm.1919P7","article-title":"Flexible bronchoscopy","volume":"191","author":"Manthous","year":"2015","journal-title":"Am J Respir Crit Care Med"},{"issue":"2","key":"10.1016\/j.chest.2018.04.045_bib2","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1128\/CMR.00085-12","article-title":"Transmission of infection by flexible gastrointestinal endoscopy and bronchoscopy","volume":"26","author":"Kovaleva","year":"2013","journal-title":"Clin Microbiol Rev"},{"key":"10.1016\/j.chest.2018.04.045_bib3","series-title":"Guidelines for Perioperative Practice","first-page":"675","article-title":"Guideline for processing flexible endoscopes","author":"Van Wicklin","year":"2016"},{"key":"10.1016\/j.chest.2018.04.045_bib4","series-title":"ANSI\/AAMI ST91: 2015 Flexible and semi-rigid endoscope processing in health care facilities","first-page":"1","year":"2015"},{"issue":"3","key":"10.1016\/j.chest.2018.04.045_bib5","doi-asserted-by":"crossref","first-page":"1742","DOI":"10.1378\/chest.128.3.1742","article-title":"American College of Chest Physicians and American Association for Bronchology [corrected] consensus statement: prevention of flexible bronchoscopy\u2013associated infection","volume":"128","author":"Mehta","year":"2005","journal-title":"Chest"},{"issue":"3","key":"10.1016\/j.chest.2018.04.045_bib6","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1086\/664495","article-title":"Lessons learned from outbreaks and pseudo-outbreaks associated with bronchoscopy","volume":"33","author":"Weber","year":"2012","journal-title":"Infect Control Hosp Epidemiol"},{"issue":"4","key":"10.1016\/j.chest.2018.04.045_bib7","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.ijmyco.2016.08.002","article-title":"Mycobacterial contamination of bronchoscopes: challenges and possible solutions in low resource settings","volume":"5","author":"Saeed","year":"2016","journal-title":"Int J Mycobacteriol"},{"issue":"2","key":"10.1016\/j.chest.2018.04.045_bib8","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1016\/j.jhin.2006.06.014","article-title":"Nosocomial outbreak of Pseudomonas aeruginosa infections related to a flexible bronchoscope","volume":"64","author":"Bou","year":"2006","journal-title":"J\u00a0Hosp Infect"},{"issue":"6","key":"10.1016\/j.chest.2018.04.045_bib9","doi-asserted-by":"crossref","first-page":"418","DOI":"10.1007\/s10156-008-0645-9","article-title":"An outbreak of Pseudomonas aeruginosa infections following thoracic surgeries occurring via the contamination of bronchoscopes and an automatic endoscope reprocessor","volume":"14","author":"Shimono","year":"2008","journal-title":"J\u00a0Infect Chemother"},{"issue":"8","key":"10.1016\/j.chest.2018.04.045_bib10","doi-asserted-by":"crossref","first-page":"936","DOI":"10.1016\/j.ajic.2014.04.022","article-title":"A\u00a0carbapenem-resistant Klebsiella pneumoniae outbreak following bronchoscopy","volume":"42","author":"Zweigner","year":"2014","journal-title":"Am J Infect Control"},{"issue":"6","key":"10.1016\/j.chest.2018.04.045_bib11","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1086\/597235","article-title":"Outbreak of Pseudomonas aeruginosa infection associated with contamination of a flexible bronchoscope","volume":"30","author":"DiazGranados","year":"2009","journal-title":"Infect Control Hosp Epidemiol"},{"key":"10.1016\/j.chest.2018.04.045_bib12","unstructured":"Dickson A. Enterobacter cloacae found in an endobronchial ultrasound scope (EBUS): now what do we do? Paper presented at: Association for Professionals in Infection Control and Epidemiology Annual Conference; June 14-16, 2017; Portland, OR."},{"issue":"7","key":"10.1016\/j.chest.2018.04.045_bib13","doi-asserted-by":"crossref","first-page":"815","DOI":"10.1016\/j.ajic.2016.01.017","article-title":"Practical toolkit for monitoring endoscope reprocessing effectiveness: identification of viable bacteria on gastroscopes, colonoscopes, and bronchoscopes","volume":"44","author":"Ofstead","year":"2016","journal-title":"Am J Infect Control"},{"key":"10.1016\/j.chest.2018.04.045_bib15","unstructured":"Food and Drug Administration. MAUDE Adverse Event Report: Olympus Endobronchial Ultrasound Scope EBUS Scope; 2016. MDR Report Key\u00a05755841."},{"key":"10.1016\/j.chest.2018.04.045_bib16","unstructured":"Food and Drug Administration. MAUDE Adverse Event Report: Olympus Endobronchial Ultrasound Scope EBUS Scope; 2016. MDR Report Key\u00a05755839."},{"key":"10.1016\/j.chest.2018.04.045_bib17","unstructured":"Food and Drug Administration. MAUDE Adverse Event Report: Karl Storz Endovision, Inc. Video Bronchoscope. 2015. MDR Report Key\u00a04895901."},{"key":"10.1016\/j.chest.2018.04.045_bib18","unstructured":"Food and Drug Administration. MAUDE Adverse Event Report: Olympus Medical Systems Corp Evis Exera Bronchovideoscope Bronchoscope. 2014. MDR Report Key\u00a04380504."},{"key":"10.1016\/j.chest.2018.04.045_bib19","unstructured":"Food and Drug Administration. MAUDE Adverse Event Report: Olympus Medical Systems Corp EVIS EXERA II Bronchovideoscope. 2016. MDR Report Key\u00a06077928."},{"key":"10.1016\/j.chest.2018.04.045_bib20","unstructured":"Food and Drug Administration. MAUDE Adverse Event Report: Olympus Medical Systems Corp. EVIS EXERA III Bronchovideoscope. 2017 MDR Report Key\u00a06816094."},{"issue":"8","key":"10.1016\/j.chest.2018.04.045_bib21","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1016\/j.ajic.2017.03.016","article-title":"The effectiveness of sterilization for flexible ureteroscopes: a real-world study","volume":"45","author":"Ofstead","year":"2017","journal-title":"Am J Infect Control"},{"issue":"2","key":"10.1016\/j.chest.2018.04.045_bib22","doi-asserted-by":"crossref","first-page":"e26","DOI":"10.1016\/j.ajic.2016.10.017","article-title":"Longitudinal assessment of reprocessing effectiveness for colonoscopes and gastroscopes: results of visual inspections, biochemical markers, and microbial cultures","volume":"45","author":"Ofstead","year":"2017","journal-title":"Am J Infect Control"},{"issue":"6","key":"10.1016\/j.chest.2018.04.045_bib23","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1111\/resp.13094","article-title":"Endobronchial ultrasound-guided transbronchial needle aspiration: safe as it sounds","volume":"22","author":"Vaidya","year":"2017","journal-title":"Respirology"},{"issue":"5","key":"10.1016\/j.chest.2018.04.045_bib24","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1097\/SGA.0000000000000266","article-title":"Standards of infection prevention in reprocessing flexible gastrointestinal endoscopes","volume":"39","author":"Herrin","year":"2016","journal-title":"Gastroenterol Nurs"},{"issue":"8","key":"10.1016\/j.chest.2018.04.045_bib25","doi-asserted-by":"crossref","first-page":"794","DOI":"10.1016\/j.ajic.2015.03.003","article-title":"Persistent contamination on colonoscopes and gastroscopes detected by biologic cultures and rapid indicators despite reprocessing performed in accordance with guidelines","volume":"43","author":"Ofstead","year":"2015","journal-title":"Am J Infect Control"},{"issue":"8","key":"10.1016\/j.chest.2018.04.045_bib26","doi-asserted-by":"crossref","first-page":"987","DOI":"10.1086\/677148","article-title":"The use of rapid indicators for the detection of organic residues on clinically used gastrointestinal endoscopes with and without visually apparent debris","volume":"35","author":"Visrodia","year":"2014","journal-title":"Infect Control Hosp Epidemiol"},{"issue":"2","key":"10.1016\/j.chest.2018.04.045_bib27","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.ajic.2012.02.030","article-title":"Comparison of adenosine triphosphate, microbiological load, and residual protein as indicators for assessing the cleanliness of flexible gastrointestinal endoscopes","volume":"41","author":"Fushimi","year":"2013","journal-title":"Am J Infect Control"},{"issue":"7","key":"10.1016\/j.chest.2018.04.045_bib28","doi-asserted-by":"crossref","first-page":"514","DOI":"10.26719\/2017.23.7.514","article-title":"Reprocessing practices for gastrointestinal endoscopes: a multicentre study in Egyptian university hospitals","volume":"23","author":"El-Sokkary","year":"2017","journal-title":"East Mediterr Health J"},{"issue":"3","key":"10.1016\/j.chest.2018.04.045_bib29","doi-asserted-by":"crossref","first-page":"245","DOI":"10.1016\/j.ajic.2012.03.018","article-title":"Validation of adenosine triphosphate to audit manual cleaning of flexible endoscope channels","volume":"41","author":"Alfa","year":"2013","journal-title":"Am J Infect Control"},{"issue":"9","key":"10.1016\/j.chest.2018.04.045_bib30","doi-asserted-by":"crossref","first-page":"860","DOI":"10.1016\/j.ajic.2011.10.006","article-title":"Development and validation of rapid use scope test strips to determine the efficacy of manual cleaning for flexible endoscope channels","volume":"40","author":"Alfa","year":"2012","journal-title":"Am J Infect Control"},{"issue":"3","key":"10.1016\/j.chest.2018.04.045_bib31","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1016\/j.ajic.2012.03.015","article-title":"The adenosine triphosphate test is a rapid and reliable audit tool to assess manual cleaning adequacy of flexible endoscope channels","volume":"41","author":"Alfa","year":"2013","journal-title":"Am J Infect Control"},{"issue":"12","key":"10.1016\/j.chest.2018.04.045_bib32","doi-asserted-by":"crossref","first-page":"1675","DOI":"10.1016\/j.ajic.2016.06.029","article-title":"Assessing residual contamination and damage inside flexible endoscopes over time","volume":"44","author":"Ofstead","year":"2016","journal-title":"Am J Infect Control"},{"issue":"3","key":"10.1016\/j.chest.2018.04.045_bib33","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1086\/669518","article-title":"Effectiveness of flexible gastrointestinal endoscope reprocessing","volume":"34","author":"Ribeiro","year":"2013","journal-title":"Infect Control Hosp Epidemiol"},{"issue":"1","key":"10.1016\/j.chest.2018.04.045_bib34","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1186\/s13104-016-2066-7","article-title":"Simulated-use validation of a sponge ATP method for determining the adequacy of manual cleaning of endoscope channels","volume":"9","author":"Alfa","year":"2016","journal-title":"BMC Res Notes"},{"issue":"6","key":"10.1016\/j.chest.2018.04.045_bib35","doi-asserted-by":"crossref","first-page":"1180","DOI":"10.1016\/j.gie.2016.10.035","article-title":"Adenosine triphosphate bioluminescence for bacteriological surveillance and reprocessing strategies for minimizing risk of infection transmission by duodenoscopes","volume":"85","author":"Sethi","year":"2016","journal-title":"Gastrointest Endosc"},{"issue":"6","key":"10.1016\/j.chest.2018.04.045_bib36","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/j.ajic.2018.03.002","article-title":"Residual moisture and waterborne pathogens inside flexible endoscopes: evidence from a multisite study of endoscope drying effectiveness","volume":"46","author":"Ofstead","year":"2018","journal-title":"Am J Infect Control"},{"issue":"1","key":"10.1016\/j.chest.2018.04.045_bib37","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.gie.2017.03.1544","article-title":"Duodenoscope reprocessing surveillance with adenosine triphosphate testing and terminal cultures: a clinical pilot study","volume":"86","author":"Visrodia","year":"2017","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.chest.2018.04.045_bib38","series-title":"A\u00a0glimpse at the true cost of reprocessing endoscopes: results of a pilot project [Communiqu\u00e9]","first-page":"62","author":"Ofstead","year":"2017"},{"key":"10.1016\/j.chest.2018.04.045_bib39","series-title":"Hygiene Management Guide for Environmental Surfaces","first-page":"1","year":"2013"},{"issue":"2","key":"10.1016\/j.chest.2018.04.045_bib40","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1055\/s-2006-945181","article-title":"ESGE-ESGENA guideline for quality assurance in reprocessing: microbiological surveillance testing in endoscopy","volume":"39","author":"Beilenhoff","year":"2007","journal-title":"Endoscopy"},{"key":"10.1016\/j.chest.2018.04.045_bib41","series-title":"Infection Control in Endoscopy [clinical update]","author":"Taylor","year":"2011"},{"key":"10.1016\/j.chest.2018.04.045_bib42","series-title":"Interim protocol for healthcare facilities regarding surveillance for bacterial contamination of duodenoscopes after reprocessing","first-page":"1","year":"2015"},{"issue":"8","key":"10.1016\/j.chest.2018.04.045_bib43","doi-asserted-by":"crossref","first-page":"704","DOI":"10.1055\/s-0042-107591","article-title":"Measures to improve microbial quality surveillance of gastrointestinal endoscopes","volume":"48","author":"Saliou","year":"2016","journal-title":"Endoscopy"},{"key":"10.1016\/j.chest.2018.04.045_bib44","unstructured":"Food and Drug Administration. MAUDE Adverse Event Report: Hoya Corporation PENTAX Tokyo Office PENTAX Fiber Bronchoscope. 2017 MDR Report Key\u00a07287335."},{"issue":"7","key":"10.1016\/j.chest.2018.04.045_bib45","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1055\/s-0042-105744","article-title":"Persistent residual contamination in endoscope channels: a fluorescence epimicroscopy study","volume":"48","author":"Herv\u00e9","year":"2016","journal-title":"Endoscopy"},{"issue":"4","key":"10.1016\/j.chest.2018.04.045_bib46","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1159\/000449137","article-title":"A\u00a0pseudo-outbreak of Pseudomonas putida and Stenotrophomonas maltophilia in a bronchoscopy unit","volume":"92","author":"Botana-Rial","year":"2016","journal-title":"Respiration"},{"issue":"suppl 1","key":"10.1016\/j.chest.2018.04.045_bib47","doi-asserted-by":"crossref","first-page":"247","DOI":"10.1093\/ofid\/ofw172.114","article-title":"Investigating a Mycobacterium avium complex pseudo-outbreak associated with outpatient bronchoscopy clinic: lessons for reprocessing","volume":"3","author":"Seidelman","year":"2016","journal-title":"Open Forum Infect Dis"},{"key":"10.1016\/j.chest.2018.04.045_bib48","unstructured":"Singh H, Duerksen DR, Schultz G, et\u00a0al. Impact of cleaning monitoring combined with channel purge storage on elimination of Escherichia coli and environmental bacteria from duodenoscopes. Gastrointest Endosc. In press."},{"key":"10.1016\/j.chest.2018.04.045_bib49","unstructured":"National Decontamination of Reusable Invasive Medical Devices Advisory Group, Quality Improvement Division, Health Service Executive (HSE). HSE Standards and Recommended Practices for Endoscope Reprocessing Units, version 2.2. October 2012. https:\/\/www.hse.ie\/eng\/about\/who\/qid\/qualityand-patient-safety-documents\/endoscopereprocessing-version22.pdf. Accessed June 5. 2018."},{"key":"10.1016\/j.chest.2018.04.045_bib50","unstructured":"Healthcare Infection Control Practices Advisory Committee (HICPAC). Essential Elements of a Reprocessing Program for Flexible Endoscopes: The Recommendations of HICPAC. 2016. https:\/\/www.cdc.gov\/hicpac\/pdf\/flexible-endoscope-reprocessing.pdf. Accessed June 5, 2018."},{"key":"10.1016\/j.chest.2018.04.045_bib51","series-title":"Lubricant Statement","author":"Drosnock","year":"2010"},{"issue":"suppl 1","key":"10.1016\/j.chest.2018.04.045_bib52","first-page":"e394","article-title":"Crystallization in the waterjet channel in colonoscopes due to simethicone","volume":"48","author":"van Stiphout","year":"2016","journal-title":"Endoscopy"},{"issue":"11","key":"10.1016\/j.chest.2018.04.045_bib53","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1016\/j.ajic.2016.05.016","article-title":"Simethicone residue remains inside gastrointestinal endoscopes despite reprocessing","volume":"44","author":"Ofstead","year":"2016","journal-title":"Am J Infect Control"},{"issue":"5 suppl","key":"10.1016\/j.chest.2018.04.045_bib54","doi-asserted-by":"crossref","first-page":"S77","DOI":"10.1016\/j.ajic.2012.12.008","article-title":"The role of biofilms in reprocessing medical devices","volume":"41","author":"Roberts","year":"2013","journal-title":"Am J Infect Control"},{"issue":"2","key":"10.1016\/j.chest.2018.04.045_bib55","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.jhin.2017.06.024","article-title":"Tolerance of Pseudomonas aeruginosa in in\u00a0vitro biofilms to high level peracetic acid disinfection","volume":"97","author":"Akinbobola","year":"2017","journal-title":"J\u00a0Hosp Infect"},{"issue":"3","key":"10.1016\/j.chest.2018.04.045_bib56","first-page":"192","article-title":"Clinical evaluation of a liquid chemical sterilization system for the flexible bronchoscopes","volume":"2","author":"Seballos","year":"1995","journal-title":"J\u00a0Bronchology Interv Pulmonol"},{"key":"10.1016\/j.chest.2018.04.045_bib57","series-title":"Video-Bronchoscope EB-450\/470 Series Operation Manual","first-page":"1","year":"2014"},{"key":"10.1016\/j.chest.2018.04.045_bib58","series-title":"BF-190 Series Reprocessing Manual","first-page":"1","year":"2013"},{"key":"10.1016\/j.chest.2018.04.045_bib59","series-title":"Instructions for Use 70\/70K Series Video Slim Scopes","year":"2016"},{"key":"10.1016\/j.chest.2018.04.045_bib60","series-title":"Sterrad 100NX System Cycle Selection","year":"2013"},{"key":"10.1016\/j.chest.2018.04.045_bib61","series-title":"Efficacy Letter","first-page":"1","year":"2017"},{"issue":"10","key":"10.1016\/j.chest.2018.04.045_bib62","doi-asserted-by":"crossref","first-page":"3275","DOI":"10.1128\/JCM.01225-12","article-title":"Probability of negative Mycobacterium tuberculosis complex cultures based on time to detection of positive cultures: a multicenter evaluation of commercial-broth-based culture systems","volume":"50","author":"Tyrrell","year":"2012","journal-title":"J\u00a0Clin Microbiol"},{"key":"10.1016\/j.chest.2018.04.045_bib63","unstructured":"Food and Drug Administration\/Centers for Disease Control and Prevention\/American Society for Microbiology Working Group on Duodenoscope Culture. Duodenoscope Surveillance Sampling and Culturing: Reducing the Risks of Infection. Atlanta, GA: Department of Health and Human Services; 2018. https:\/\/www.fda.gov\/downloads\/MedicalDevices\/ProductsandMedicalProcedures\/ReprocessingofReusableMedicalDevices\/UCM597949.pdf. Accessed June 5, 2018."}],"container-title":["Chest"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S001236921830802X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S001236921830802X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,15]],"date-time":"2025-09-15T08:04:01Z","timestamp":1757923441000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S001236921830802X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,11]]},"references-count":62,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2018,11]]}},"alternative-id":["S001236921830802X"],"URL":"https:\/\/doi.org\/10.1016\/j.chest.2018.04.045","relation":{},"ISSN":["0012-3692"],"issn-type":[{"value":"0012-3692","type":"print"}],"subject":[],"published":{"date-parts":[[2018,11]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effectiveness of Reprocessing for Flexible Bronchoscopes and Endobronchial Ultrasound Bronchoscopes","name":"articletitle","label":"Article Title"},{"value":"Chest","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.chest.2018.04.045","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}