{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,9]],"date-time":"2026-10-09T17:22:31Z","timestamp":1791566551724,"version":"4.3.4"},"reference-count":26,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T00:00:00Z","timestamp":1648771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,4,1]],"date-time":"2022-04-01T00:00:00Z","timestamp":1648771200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100000738","name":"Department of Veterans Affairs","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000738","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000002","name":"National Institutes of Health","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000002","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/100000133","name":"AHRQ","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100000133","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal.chestnet.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Chest"],"published-print":{"date-parts":[[2022,4]]},"DOI":"10.1016\/j.chest.2021.09.025","type":"journal-article","created":{"date-parts":[[2021,9,27]],"date-time":"2021-09-27T14:52:38Z","timestamp":1632754358000},"page":"971-978","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":97,"title":["Racial Bias in Pulse Oximetry Measurement Among Patients About to Undergo Extracorporeal Membrane Oxygenation in 2019-2020"],"prefix":"10.1016","volume":"161","author":[{"given":"Valeria S.M.","family":"Valbuena","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ryan P.","family":"Barbaro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dru","family":"Claar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Thomas S.","family":"Valley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert P.","family":"Dickson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven E.","family":"Gay","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael W.","family":"Sjoding","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Theodore J.","family":"Iwashyna","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"12","key":"10.1016\/j.chest.2021.09.025_bib1","doi-asserted-by":"crossref","first-page":"1671","DOI":"10.4187\/respcare.05208","article-title":"Pulse oximetry: beyond SpO2","volume":"61","author":"Hess","year":"2016","journal-title":"Respir Care"},{"issue":"1","key":"10.1016\/j.chest.2021.09.025_bib2","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1186\/s13054-015-0984-8","article-title":"Pulse oximetry","volume":"19","author":"Jubran","year":"2015","journal-title":"Crit Care"},{"issue":"1","key":"10.1016\/j.chest.2021.09.025_bib3","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1213\/ANE.0000000000001283","article-title":"Advanced uses of pulse oximetry for monitoring mechanically ventilated patients","volume":"124","author":"Tusman","year":"2017","journal-title":"Anesth Analg"},{"issue":"11","key":"10.1016\/j.chest.2021.09.025_bib4","doi-asserted-by":"crossref","first-page":"989","DOI":"10.1056\/NEJMoa1903297","article-title":"Conservative oxygen therapy during mechanical ventilation in the ICU","volume":"382","author":"Mackle","year":"2020","journal-title":"N\u00a0Engl J Med"},{"issue":"3","key":"10.1016\/j.chest.2021.09.025_bib5","doi-asserted-by":"crossref","first-page":"520","DOI":"10.1097\/ALN.0000000000002002","article-title":"Four types of pulse oximeters accurately detect hypoxia during low perfusion and motion","volume":"128","author":"Louie","year":"2018","journal-title":"Anesthesiology"},{"issue":"4","key":"10.1016\/j.chest.2021.09.025_bib6","doi-asserted-by":"crossref","first-page":"715","DOI":"10.1097\/00000542-200504000-00004","article-title":"Effects of skin pigmentation on pulse oximeter accuracy at low saturation","volume":"102","author":"Bickler","year":"2005","journal-title":"Anesthesiology"},{"issue":"6","key":"10.1016\/j.chest.2021.09.025_bib7","doi-asserted-by":"crossref","first-page":"1420","DOI":"10.1378\/chest.97.6.1420","article-title":"Reliability of pulse oximetry in titrating supplemental oxygen therapy in ventilator-dependent patients","volume":"97","author":"Jubran","year":"1990","journal-title":"Chest"},{"issue":"25","key":"10.1016\/j.chest.2021.09.025_bib8","doi-asserted-by":"crossref","first-page":"2477","DOI":"10.1056\/NEJMc2029240","article-title":"Racial bias in pulse oximetry measurement","volume":"383","author":"Sjoding","year":"2020","journal-title":"N\u00a0Engl J Med"},{"issue":"10257","key":"10.1016\/j.chest.2021.09.025_bib9","doi-asserted-by":"crossref","first-page":"1071","DOI":"10.1016\/S0140-6736(20)32008-0","article-title":"Extracorporeal membrane oxygenation support in COVID-19: an international cohort study of the Extracorporeal Life Support Organization registry","volume":"396","author":"Barbaro","year":"2020","journal-title":"Lancet"},{"issue":"12","key":"10.1016\/j.chest.2021.09.025_bib10","doi-asserted-by":"crossref","first-page":"1373","DOI":"10.1016\/S0895-4356(96)00236-3","article-title":"A\u00a0simulation study of the number of events per variable in logistic regression analysis","volume":"49","author":"Peduzzi","year":"1996","journal-title":"J\u00a0Clin Epidemiol"},{"issue":"1","key":"10.1016\/j.chest.2021.09.025_bib11","doi-asserted-by":"crossref","DOI":"10.1136\/bmjresp-2020-000778","article-title":"Working accuracy of pulse oximetry in COVID-19 patients stepping down from intensive care: a clinical evaluation","volume":"7","author":"Philip","year":"2020","journal-title":"BMJ Open Respir Res"},{"issue":"8476","key":"10.1016\/j.chest.2021.09.025_bib12","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1016\/S0140-6736(86)90837-8","article-title":"Statistical methods for assessing agreement between two methods of clinical measurement","volume":"1","author":"Bland","year":"1986","journal-title":"Lancet"},{"issue":"8982","key":"10.1016\/j.chest.2021.09.025_bib13","doi-asserted-by":"crossref","first-page":"1085","DOI":"10.1016\/S0140-6736(95)91748-9","article-title":"Comparing methods of measurement: why plotting difference against standard method is misleading","volume":"346","author":"Bland","year":"1995","journal-title":"Lancet"},{"issue":"2","key":"10.1016\/j.chest.2021.09.025_bib14","doi-asserted-by":"crossref","first-page":"135","DOI":"10.1177\/096228029900800204","article-title":"Measuring agreement in method comparison studies","volume":"8","author":"Bland","year":"1999","journal-title":"Stat Methods Med Res"},{"key":"10.1016\/j.chest.2021.09.025_bib15","article-title":"How a popular medical device encodes racial bias","author":"Moran-Thomas","year":"2021","journal-title":"Boston Review"},{"key":"10.1016\/j.chest.2021.09.025_bib16","article-title":"Oximeters used to be designed for equity. What happened?","author":"Moran-Thomas","year":"2021","journal-title":"Wired"},{"issue":"5","key":"10.1016\/j.chest.2021.09.025_bib17","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0126979","article-title":"Accuracy of pulse oximeters in detecting hypoxemia in patients with chronic thromboembolic pulmonary hypertension","volume":"10","author":"Kohyama","year":"2015","journal-title":"PLoS One"},{"key":"10.1016\/j.chest.2021.09.025_bib18","first-page":"1","article-title":"Educational outcomes of Asian and Hispanic Americans: the significance of skin color","volume":"44","author":"Ryabov","year":"2016","journal-title":"Res Social Stratif Mobil"},{"issue":"5","key":"10.1016\/j.chest.2021.09.025_bib19","doi-asserted-by":"crossref","first-page":"1337","DOI":"10.1016\/j.ssresearch.2010.12.006","article-title":"The persistence of skin color discrimination for immigrants","volume":"40","author":"Hersch","year":"2011","journal-title":"Social Sci Res"},{"key":"10.1016\/j.chest.2021.09.025_bib20","author":"Warren"},{"issue":"25","key":"10.1016\/j.chest.2021.09.025_bib21","doi-asserted-by":"crossref","first-page":"2477","DOI":"10.1056\/NEJMc2029240","article-title":"Racial bias in pulse oximetry measurement [Letter to the Editor]","volume":"383","author":"Sjoding","year":"2020","journal-title":"N\u00a0Engl J Med"},{"key":"10.1016\/j.chest.2021.09.025_bib22","article-title":"\u201cThese numbers are incredibly important\u201d: Doctors and lawmakers call on FDA to address racial disparities in pulse oximeters","author":"Brodwin","year":"2021","journal-title":"STAT News website"},{"issue":"4","key":"10.1016\/j.chest.2021.09.025_bib24","doi-asserted-by":"crossref","first-page":"e37","DOI":"10.1016\/S2213-2600(21)00102-8","article-title":"Critical care trainees call for pulse oximetry reform","volume":"9","author":"Hidalgo","year":"2021","journal-title":"Lancet Respir Med"},{"issue":"9","key":"10.1016\/j.chest.2021.09.025_bib26","doi-asserted-by":"crossref","first-page":"1040","DOI":"10.1513\/AnnalsATS.202005-418FR","article-title":"Pulse oximetry for monitoring patients with COVID-19 at home: potential pitfalls and practical guidance","volume":"17","author":"Luks","year":"2020","journal-title":"Ann Am Thorac Soc"},{"issue":"6 suppl","key":"10.1016\/j.chest.2021.09.025_bib27","doi-asserted-by":"crossref","first-page":"S18","DOI":"10.1213\/01.ane.0000285988.35174.d9","article-title":"Dark skin decreases the accuracy of pulse oximeters at low oxygen saturation: the effects of oximeter probe type and gender","volume":"105","author":"Feiner","year":"2007","journal-title":"Anesth Analg"},{"issue":"4","key":"10.1016\/j.chest.2021.09.025_bib28","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1111\/j.1399-6576.1992.tb03479.x","article-title":"The influence of changes in blood flow on the accuracy of pulse oximetry in humans","volume":"36","author":"Vegfors","year":"1992","journal-title":"Acta Anaesthesiol Scand"}],"container-title":["Chest"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0012369221040654?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0012369221040654?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,15]],"date-time":"2025-09-15T08:44:16Z","timestamp":1757925856000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0012369221040654"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,4]]},"references-count":26,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2022,4]]}},"alternative-id":["S0012369221040654"],"URL":"https:\/\/doi.org\/10.1016\/j.chest.2021.09.025","relation":{},"ISSN":["0012-3692"],"issn-type":[{"value":"0012-3692","type":"print"}],"subject":[],"published":{"date-parts":[[2022,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Racial Bias in Pulse Oximetry Measurement Among Patients About to Undergo Extracorporeal Membrane Oxygenation in 2019-2020","name":"articletitle","label":"Article Title"},{"value":"Chest","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.chest.2021.09.025","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}