{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,31]],"date-time":"2026-10-31T05:33:55Z","timestamp":1793424835000,"version":"4.5.0"},"reference-count":23,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2023,4,1]],"date-time":"2023-04-01T00:00:00Z","timestamp":1680307200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,4,1]],"date-time":"2023-04-01T00:00:00Z","timestamp":1680307200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100004374","name":"Medtronic","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100004374","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal.chestnet.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Chest"],"published-print":{"date-parts":[[2023,4]]},"DOI":"10.1016\/j.chest.2022.10.019","type":"journal-article","created":{"date-parts":[[2022,10,29]],"date-time":"2022-10-29T17:48:24Z","timestamp":1667065704000},"page":"977-984","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":83,"title":["Shape-Sensing Robotic-Assisted Bronchoscopy vs\u00a0Digital Tomosynthesis-Corrected Electromagnetic Navigation Bronchoscopy"],"prefix":"10.1016","volume":"163","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-7523-7019","authenticated-orcid":false,"given":"See-Wei","family":"Low","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Robert J.","family":"Lentz","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heidi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James","family":"Katsis","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8540-487X","authenticated-orcid":false,"given":"Matthew C.","family":"Aboudara","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-5932-9498","authenticated-orcid":false,"given":"Samuel","family":"Whatley","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3938-8968","authenticated-orcid":false,"given":"Rafael","family":"Paez","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-7222-6840","authenticated-orcid":false,"given":"Otis B.","family":"Rickman","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6504-2063","authenticated-orcid":false,"given":"Fabien","family":"Maldonado","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"10","key":"10.1016\/j.chest.2022.10.019_bib1","doi-asserted-by":"crossref","first-page":"1208","DOI":"10.1164\/rccm.201505-0990OC","article-title":"Recent trends in the identification of incidental pulmonary nodules","volume":"192","author":"Gould","year":"2015","journal-title":"Am J Respir Crit Care Med"},{"issue":"6","key":"10.1016\/j.chest.2022.10.019_bib2","doi-asserted-by":"crossref","first-page":"503","DOI":"10.1056\/NEJMoa1911793","article-title":"Reduced lung-cancer mortality with volume CT screening in a randomized trial","volume":"382","author":"de Koning","year":"2020","journal-title":"N\u00a0Engl J Med"},{"issue":"2","key":"10.1016\/j.chest.2022.10.019_bib3","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1016\/j.chest.2020.08.2048","article-title":"Survival following detection of stage I lung cancer by screening in the National Lung Screening Trial","volume":"159","author":"Gierada","year":"2021","journal-title":"Chest"},{"issue":"5","key":"10.1016\/j.chest.2022.10.019_bib4","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1056\/NEJMoa1102873","article-title":"Reduced lung-cancer mortality with low-dose computed tomographic screening","volume":"365","author":"Aberle","year":"2011","journal-title":"N\u00a0Engl J Med"},{"issue":"suppl 4","key":"10.1016\/j.chest.2022.10.019_bib5","first-page":"S304","article-title":"Transthoracic needle biopsy of the lung","volume":"7","author":"DiBardino","year":"2015","journal-title":"J\u00a0Thorac Dis"},{"issue":"3","key":"10.1016\/j.chest.2022.10.019_bib6","doi-asserted-by":"crossref","first-page":"137","DOI":"10.7326\/0003-4819-155-3-201108020-00003","article-title":"Population-based risk for complications after transthoracic needle lung biopsy of a pulmonary nodule: an analysis of discharge records","volume":"155","author":"Wiener","year":"2011","journal-title":"Ann Intern Med"},{"issue":"4","key":"10.1016\/j.chest.2022.10.019_bib7","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1378\/chest.129.4.988","article-title":"Real-time electromagnetic navigation bronchoscopy to peripheral lung lesions using overlaid CT images: the first human study","volume":"129","author":"Schwarz","year":"2006","journal-title":"Chest"},{"issue":"2","key":"10.1016\/j.chest.2022.10.019_bib8","doi-asserted-by":"crossref","first-page":"206","DOI":"10.1111\/resp.13609","article-title":"Improved diagnostic yield for lung nodules with digital tomosynthesis-corrected navigational bronchoscopy: initial experience with a novel adjunct","volume":"25","author":"Aboudara","year":"2020","journal-title":"Respirology"},{"issue":"4","key":"10.1016\/j.chest.2022.10.019_bib9","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1097\/LBR.0000000000000766","article-title":"Diagnostic yield of digital tomosynthesis-assisted navigational bronchoscopy for indeterminate lung nodules","volume":"28","author":"Katsis","year":"2021","journal-title":"J\u00a0Bronchology Interv Pulmonol"},{"issue":"2","key":"10.1016\/j.chest.2022.10.019_bib10","doi-asserted-by":"crossref","first-page":"166","DOI":"10.1159\/000518009","article-title":"Sight unseen: diagnostic yield and safety outcomes of a novel multimodality navigation bronchoscopy platform with real-time target acquisition","volume":"101","author":"Avasarala","year":"2022","journal-title":"Respiration"},{"issue":"2","key":"10.1016\/j.chest.2022.10.019_bib11","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1159\/000498951","article-title":"First human use of a new robotic-assisted fiber optic sensing navigation system for small peripheral pulmonary nodules","volume":"98","author":"Fielding","year":"2019","journal-title":"Respiration"},{"issue":"2","key":"10.1016\/j.chest.2022.10.019_bib12","doi-asserted-by":"crossref","first-page":"572","DOI":"10.1016\/j.chest.2021.07.2169","article-title":"Shape-sensing robotic-assisted bronchoscopy in the diagnosis of pulmonary parenchymal lesions","volume":"161","author":"Kalchiem-Dekel","year":"2022","journal-title":"Chest"},{"issue":"2","key":"10.1016\/j.chest.2022.10.019_bib13","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1007\/s00408-021-00421-1","article-title":"Robotic-assisted navigation bronchoscopy as a paradigm shift in peripheral lung access","volume":"199","author":"Benn","year":"2021","journal-title":"Lung"},{"issue":"1","key":"10.1016\/j.chest.2022.10.019_bib14","doi-asserted-by":"crossref","first-page":"243","DOI":"10.1186\/s12890-019-1010-8","article-title":"Robot-assisted bronchoscopy for pulmonary lesion diagnosis: results from the initial multicenter experience","volume":"19","author":"Chaddha","year":"2019","journal-title":"BMC Pulm Med"},{"issue":"2","key":"10.1016\/j.chest.2022.10.019_bib15","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1016\/j.chest.2020.08.2047","article-title":"Robotic bronchoscopy for peripheral pulmonary lesions: a multicenter pilot and feasibility study (BENEFIT)","volume":"159","author":"Chen","year":"2021","journal-title":"Chest"},{"issue":"2","key":"10.1016\/j.chest.2022.10.019_bib16","doi-asserted-by":"crossref","first-page":"377","DOI":"10.1016\/j.jbi.2008.08.010","article-title":"Research electronic data capture (REDCap)\u2014a metadata-driven methodology and workflow process for providing translational research informatics support","volume":"42","author":"Harris","year":"2009","journal-title":"J\u00a0Biomed Inform"},{"key":"10.1016\/j.chest.2022.10.019_bib17","doi-asserted-by":"crossref","first-page":"103208","DOI":"10.1016\/j.jbi.2019.103208","article-title":"The REDCap consortium: building an international community of software platform partners","volume":"95","author":"Harris","year":"2019","journal-title":"J Biomed Inform. 07"},{"issue":"1","key":"10.1016\/j.chest.2022.10.019_bib18","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1164\/rccm.201507-1332OC","article-title":"Diagnostic yield and complications of bronchoscopy for peripheral lung lesions. results of the AQuIRE registry","volume":"193","author":"Ost","year":"2016","journal-title":"Am J Respir Crit Care Med"},{"issue":"1","key":"10.1016\/j.chest.2022.10.019_bib20","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1186\/s12890-017-0403-9","article-title":"Electromagnetic navigation bronchoscopy to access lung lesions in 1,000 subjects: first results of the prospective, multicenter NAVIGATE study","volume":"17","author":"Khandhar","year":"2017","journal-title":"BMC Pulm Med"},{"issue":"4","key":"10.1016\/j.chest.2022.10.019_bib21","doi-asserted-by":"crossref","first-page":"519","DOI":"10.1016\/j.jtho.2021.12.008","article-title":"NAVIGATE 24-month results: electromagnetic navigation bronchoscopy for pulmonary lesions at 37 centers in Europe and the United States","volume":"17","author":"Folch","year":"2022","journal-title":"J\u00a0Thorac Oncol"},{"issue":"1","key":"10.1016\/j.chest.2022.10.019_bib22","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1186\/s12890-016-0228-y","article-title":"Design of a prospective, multicenter, global, cohort study of electromagnetic navigation bronchoscopy","volume":"16","author":"Folch","year":"2016","journal-title":"BMC Pulm Med"},{"issue":"5","key":"10.1016\/j.chest.2022.10.019_bib23","doi-asserted-by":"crossref","first-page":"1426","DOI":"10.1016\/j.chest.2021.08.074","article-title":"The impact of alternative approaches to diagnostic yield calculation in studies of bronchoscopy","volume":"161","author":"Vachani","year":"2022","journal-title":"Chest"},{"issue":"3","key":"10.1016\/j.chest.2022.10.019_bib24","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.mayocpiqo.2022.02.004","article-title":"Combining shape-sensing robotic bronchoscopy with mobile three-dimensional imaging to verify tool-in-lesion and overcome divergence: a pilot study","volume":"6","author":"Reisenauer","year":"2022","journal-title":"Mayo Clin Proc Innov Qual Outcomes"}],"container-title":["Chest"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0012369222040326?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0012369222040326?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,15]],"date-time":"2025-09-15T08:49:58Z","timestamp":1757926198000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0012369222040326"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,4]]},"references-count":23,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2023,4]]}},"alternative-id":["S0012369222040326"],"URL":"https:\/\/doi.org\/10.1016\/j.chest.2022.10.019","relation":{},"ISSN":["0012-3692"],"issn-type":[{"value":"0012-3692","type":"print"}],"subject":[],"published":{"date-parts":[[2023,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Shape-Sensing Robotic-Assisted Bronchoscopy vs\u00a0Digital Tomosynthesis-Corrected Electromagnetic Navigation Bronchoscopy","name":"articletitle","label":"Article Title"},{"value":"Chest","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.chest.2022.10.019","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 American College of Chest Physicians. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}