{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T20:18:21Z","timestamp":1787861901367,"version":"build-2784847793"},"reference-count":42,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/100013018","name":"Hospital for Special Surgery","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100013018","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","journal.chestnet.org","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["CHEST"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.chest.2026.05.054","type":"journal-article","created":{"date-parts":[[2026,8,4]],"date-time":"2026-08-04T06:40:48Z","timestamp":1785825648000},"update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["Surface Topographic Assessment of Forced Pulmonary Maneuvers"],"prefix":"10.1016","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-1986-3247","authenticated-orcid":false,"given":"Benjamin N.","family":"Groisser","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ankush","family":"Thakur","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Howard J.","family":"Hillstrom","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Isabella G.","family":"Marsh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher J.","family":"Williams","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ithika S.","family":"Senthilnathan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jenna L.","family":"Wisch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0000-1328-0206","authenticated-orcid":false,"given":"Colson P.","family":"Zucker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matthew E.","family":"Cunningham","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8769-0969","authenticated-orcid":false,"given":"M. Timothy","family":"Hresko","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ram","family":"Haddas","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John S.","family":"Blanco","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mary F.","family":"DiMaio","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Roger F.","family":"Widmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jessica H.","family":"Heyer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.chest.2026.05.054_bib1","doi-asserted-by":"crossref","DOI":"10.1183\/13993003.01499-2021","article-title":"ERS\/ATS technical standard on interpretive strategies for routine lung function tests","volume":"60","author":"Stanojevic","year":"2022","journal-title":"Eur Respir J"},{"issue":"4","key":"10.1016\/j.chest.2026.05.054_bib3","doi-asserted-by":"crossref","first-page":"745","DOI":"10.1016\/j.mcna.2012.04.011","article-title":"The importance of the assessment of pulmonary function in COPD","volume":"96","author":"Bailey","year":"2012","journal-title":"Med Clin North Am"},{"issue":"1","key":"10.1016\/j.chest.2026.05.054_bib4","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1007\/s00586-022-07371-z","article-title":"Is impaired lung function related to spinal deformities in patients with adolescent idiopathic scoliosis? A systematic review and meta-analysis\u2014SOSORT 2019 award paper","volume":"32","author":"Kan","year":"2023","journal-title":"Eur Spine J"},{"issue":"4","key":"10.1016\/j.chest.2026.05.054_bib5","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1002\/ppul.25182","article-title":"Pulmonary function testing in patients with neuromuscular disease","volume":"56","author":"Miller","year":"2021","journal-title":"Pediatr Pulmonol"},{"issue":"8","key":"10.1016\/j.chest.2026.05.054_bib6","doi-asserted-by":"crossref","first-page":"e70","DOI":"10.1164\/rccm.201908-1590ST","article-title":"Standardization of spirometry 2019 update. An official American Thoracic Society and European Respiratory Society technical statement","volume":"200","author":"Graham","year":"2019","journal-title":"Am J Respir Crit Care Med"},{"issue":"7","key":"10.1016\/j.chest.2026.05.054_bib7","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1016\/j.rmed.2011.02.006","article-title":"Body plethysmography\u2014its principles and clinical use","volume":"105","author":"Cri\u00e9e","year":"2011","journal-title":"Respir Med"},{"issue":"2","key":"10.1016\/j.chest.2026.05.054_bib8","doi-asserted-by":"crossref","first-page":"319","DOI":"10.1183\/09031936.05.00034805","article-title":"Standardisation of spirometry","volume":"26","author":"Miller","year":"2005","journal-title":"Eur Respir J"},{"issue":"10","key":"10.1016\/j.chest.2026.05.054_bib9","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1016\/j.arbres.2023.04.004","article-title":"ALAT 2023 recommendations for performing respiratory function studies","volume":"59","author":"Sch\u00f6nffeldt-Guerrero","year":"2023","journal-title":"Arch Bronconeumol"},{"issue":"9","key":"10.1016\/j.chest.2026.05.054_bib10","doi-asserted-by":"crossref","first-page":"585","DOI":"10.31128\/AJGP-09-22-6568","article-title":"Barriers to spirometry in Australian general practice: a systematic review","volume":"52","author":"Lim","year":"2023","journal-title":"Aust J Gen Pract"},{"issue":"2","key":"10.1016\/j.chest.2026.05.054_bib11","doi-asserted-by":"crossref","first-page":"S1","DOI":"10.1513\/AnnalsATS.201301-017ST","article-title":"An official American Thoracic Society workshop report: optimal lung function tests for monitoring cystic fibrosis, bronchopulmonary dysplasia, and recurrent wheezing in children less than 6 years of age","volume":"10","author":"Rosenfeld","year":"2013","journal-title":"Ann Am Thorac Soc"},{"issue":"4","key":"10.1016\/j.chest.2026.05.054_bib12","doi-asserted-by":"crossref","first-page":"717","DOI":"10.1016\/j.ejcdt.2017.08.006","article-title":"Spirometry using facemask versus conventional tube in patients with neuromuscular disorders","volume":"66","author":"Abdelgawad","year":"2017","journal-title":"Egypt J Chest Dis Tuberc"},{"issue":"6","key":"10.1016\/j.chest.2026.05.054_bib13","doi-asserted-by":"crossref","first-page":"1001","DOI":"10.1183\/09031936.03.00028103","article-title":"Face mask spirometry and respiratory pressures in normal subjects","volume":"22","author":"Wohlgemuth","year":"2003","journal-title":"Eur Respir J"},{"issue":"6","key":"10.1016\/j.chest.2026.05.054_bib14","doi-asserted-by":"crossref","first-page":"4292","DOI":"10.1007\/s00330-021-08482-9","article-title":"Automatic quantitative computed tomography measurement of longitudinal lung volume loss in interstitial lung diseases","volume":"32","author":"Si-Mohamed","year":"2022","journal-title":"Eur Radiol"},{"issue":"22","key":"10.1016\/j.chest.2026.05.054_bib15","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography\u2014an increasing source of radiation exposure","volume":"357","author":"Brenner","year":"2007","journal-title":"N Eng J Med"},{"issue":"6","key":"10.1016\/j.chest.2026.05.054_bib16","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1001\/jamainternmed.2025.0505","article-title":"Projected lifetime cancer risks from current computed tomography imaging","volume":"185","author":"Smith-Bindman","year":"2025","journal-title":"JAMA Intern Med"},{"issue":"2","key":"10.1016\/j.chest.2026.05.054_bib17","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.chest.2020.07.066","article-title":"Thoracic quantitative dynamic MRI to understand developmental changes in normal ventilatory dynamics","volume":"159","author":"Tong","year":"2021","journal-title":"Chest"},{"issue":"2","key":"10.1016\/j.chest.2026.05.054_bib18","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1159\/000212117","article-title":"Respiratory monitoring by inductive plethysmography in unrestrained subjects using position sensor-adjusted calibration","volume":"79","author":"Br\u00fcllmann","year":"2009","journal-title":"Respiration"},{"issue":"6","key":"10.1016\/j.chest.2026.05.054_bib19","doi-asserted-by":"crossref","first-page":"261","DOI":"10.3390\/a17060261","article-title":"Artificial intelligence-based algorithms and healthcare applications of respiratory inductance plethysmography: a systematic review","volume":"17","author":"Rahman","year":"2024","journal-title":"Algorithms"},{"issue":"6","key":"10.1016\/j.chest.2026.05.054_bib20","doi-asserted-by":"crossref","first-page":"2680","DOI":"10.1152\/jappl.1996.81.6.2680","article-title":"Chest wall and lung volume estimation by optical reflectance motion analysis","volume":"81","author":"Cala","year":"1996","journal-title":"J Appl Physiol"},{"issue":"5","key":"10.1016\/j.chest.2026.05.054_bib21","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1159\/000462916","article-title":"Optoelectronic plethysmography in clinical practice and research: a review","volume":"93","author":"Massaroni","year":"2017","journal-title":"Respiration"},{"key":"10.1016\/j.chest.2026.05.054_bib22","first-page":"2371","article-title":"Noncontact respiratory measurement of volume change using depth camera","volume":"2012","author":"Yu","year":"2012","journal-title":"Annu Int Conf IEEE Eng Med Biol Soc"},{"issue":"24","key":"10.1016\/j.chest.2026.05.054_bib23","doi-asserted-by":"crossref","first-page":"7252","DOI":"10.3390\/s20247252","article-title":"Advancements in methods and camera-based sensors for the quantification of respiration","volume":"20","author":"Rehouma","year":"2020","journal-title":"Sensors (Basel)"},{"issue":"4","key":"10.1016\/j.chest.2026.05.054_bib24","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.3390\/s21041135","article-title":"Noncontact respiratory monitoring using depth sensing cameras: a review of current literature","volume":"21","author":"Addison","year":"2021","journal-title":"Sensors (Basel)"},{"key":"10.1016\/j.chest.2026.05.054_bib25","doi-asserted-by":"crossref","DOI":"10.3389\/fphys.2020.552942","article-title":"Development and clinical application of a novel non-contact early airflow limitation screening system using an infrared time-of-flight depth image sensor","volume":"11","author":"Takamoto","year":"2020","journal-title":"Front Physiol"},{"issue":"24","key":"10.1016\/j.chest.2026.05.054_bib26","doi-asserted-by":"crossref","first-page":"9680","DOI":"10.3390\/s22249680","article-title":"Depth-based measurement of respiratory volumes: a review","volume":"22","author":"Wichum","year":"2022","journal-title":"Sensors"},{"issue":"6","key":"10.1016\/j.chest.2026.05.054_bib27","first-page":"1421","article-title":"Depth-based whole body photoplethysmography in remote pulmonary function testing","volume":"65","author":"Soleimani","year":"2017","journal-title":"IEEE Trans Biomed Eng"},{"issue":"21","key":"10.1016\/j.chest.2026.05.054_bib28","doi-asserted-by":"crossref","first-page":"2664","DOI":"10.3390\/healthcare13212664","article-title":"Thoracic motion analysis using a TrueDepth camera in patients with relapsing polychondritis: a pilot study","volume":"13","author":"Nishi","year":"2025","journal-title":"Healthcare"},{"issue":"5","key":"10.1016\/j.chest.2026.05.054_bib29","doi-asserted-by":"crossref","first-page":"1025","DOI":"10.1007\/s10877-019-00417-6","article-title":"Continuous respiratory rate monitoring during an acute hypoxic challenge using a depth sensing camera","volume":"34","author":"Addison","year":"2020","journal-title":"J Clin Monit Comput"},{"issue":"5","key":"10.1016\/j.chest.2026.05.054_bib30","doi-asserted-by":"crossref","first-page":"1035","DOI":"10.1007\/s43390-022-00505-9","article-title":"Reliability of automated topographic measurements for spine deformity","volume":"10","author":"Groisser","year":"2022","journal-title":"Spine Deform"},{"issue":"11","key":"10.1016\/j.chest.2026.05.054_bib31","doi-asserted-by":"crossref","first-page":"1756","DOI":"10.3390\/children9111756","article-title":"3D surface topographic optical scans yield highly reliable global spine range of motion measurements in scoliotic and non-scoliotic adolescents","volume":"9","author":"Page","year":"2022","journal-title":"Children"},{"issue":"6","key":"10.1016\/j.chest.2026.05.054_bib32","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1097\/BPO.0000000000002677","article-title":"Novel surface topographic assessment of lung volume and pulmonary function tests in idiopathic scoliosis: a preliminary study","volume":"44","author":"Heyer","year":"2024","journal-title":"J Pediatr Orthop"},{"issue":"1","key":"10.1016\/j.chest.2026.05.054_bib33","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1164\/ajrccm.159.1.9712108","article-title":"Spirometric reference values from a sample of the general US population","volume":"159","author":"Hankinson","year":"1999","journal-title":"Am J Respir Crit Care Med"},{"issue":"2","key":"10.1016\/j.chest.2026.05.054_bib34","doi-asserted-by":"crossref","first-page":"420","DOI":"10.1037\/0033-2909.86.2.420","article-title":"Intraclass correlations: uses in assessing rater reliability","volume":"86","author":"Shrout","year":"1979","journal-title":"Psychol Bull"},{"issue":"4","key":"10.1016\/j.chest.2026.05.054_bib35","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1080\/10543400701329422","article-title":"Agreement between methods of measurement with multiple observations per individual","volume":"17","author":"Bland","year":"2007","journal-title":"J Biopharm Stat"},{"issue":"1","key":"10.1016\/j.chest.2026.05.054_bib36","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1081\/COPD-200053377","article-title":"Minimal clinically important differences in COPD lung function","volume":"2","author":"Donohue","year":"2005","journal-title":"COPD"},{"issue":"12","key":"10.1016\/j.chest.2026.05.054_bib37","doi-asserted-by":"crossref","first-page":"1573","DOI":"10.1164\/rccm.202012-4322LE","article-title":"FEV1 minimum important difference versus minimal detectable difference? In search of the unicorn","volume":"203","author":"Crim","year":"2021","journal-title":"Am J Respir Crit Care Med"},{"issue":"2","key":"10.1016\/j.chest.2026.05.054_bib38","doi-asserted-by":"crossref","first-page":"394","DOI":"10.1016\/j.chest.2023.03.011","article-title":"Respiratory management of patients with neuromuscular weakness: an American College of Chest Physicians clinical practice guideline and expert panel report","volume":"164","author":"Khan","year":"2023","journal-title":"Chest"},{"issue":"1","key":"10.1016\/j.chest.2026.05.054_bib39","doi-asserted-by":"crossref","first-page":"72","DOI":"10.7861\/clinmedicine.14-1-72","article-title":"Respiratory involvement in neuromuscular disease","volume":"14","author":"Bourke","year":"2014","journal-title":"Clin Med (Lond)"},{"issue":"3","key":"10.1016\/j.chest.2026.05.054_bib40","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1378\/chest.12-2317","article-title":"Optoelectronic plethysmography as an alternative method for the diagnosis of unilateral diaphragmatic weakness","volume":"144","author":"Boudarham","year":"2013","journal-title":"Chest"},{"issue":"6","key":"10.1016\/j.chest.2026.05.054_bib41","doi-asserted-by":"crossref","first-page":"1172","DOI":"10.1016\/j.jpedsurg.2011.03.047","article-title":"Regional chest wall motion dysfunction in patients with pectus excavatum demonstrated via optoelectronic plethysmography","volume":"46","author":"Redlinger","year":"2011","journal-title":"J Pediatr Surg"},{"issue":"3","key":"10.1016\/j.chest.2026.05.054_bib42","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1016\/j.resp.2007.10.019","article-title":"Chest wall kinematics and Hoover's sign","volume":"160","author":"Binazzi","year":"2008","journal-title":"Respir Physiol Neurobiol"},{"issue":"8","key":"10.1016\/j.chest.2026.05.054_bib43","doi-asserted-by":"crossref","first-page":"1963","DOI":"10.1007\/s10439-017-1840-6","article-title":"Chest wall kinematics using triangular Cosserat point elements in healthy and neuromuscular subjects","volume":"45","author":"Solav","year":"2017","journal-title":"Ann Biomed Eng"}],"container-title":["CHEST"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0012369226063294?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0012369226063294?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,27]],"date-time":"2026-08-27T19:30:28Z","timestamp":1787859028000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0012369226063294"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":42,"alternative-id":["S0012369226063294"],"URL":"https:\/\/doi.org\/10.1016\/j.chest.2026.05.054","relation":{},"ISSN":["0012-3692"],"issn-type":[{"value":"0012-3692","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Surface Topographic Assessment of Forced Pulmonary Maneuvers","name":"articletitle","label":"Article Title"},{"value":"CHEST","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.chest.2026.05.054","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 Published by Elsevier Inc under license from the American College of Chest Physicians.","name":"copyright","label":"Copyright"}]}}