{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,3]],"date-time":"2026-07-03T03:29:08Z","timestamp":1783049348668,"version":"3.54.6"},"reference-count":36,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,10,1]],"date-time":"2017-10-01T00:00:00Z","timestamp":1506816000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"name":"Sao Paulo State Science Foundation","award":["2015\/12306-2"],"award-info":[{"award-number":["2015\/12306-2"]}]},{"name":"Molecular Life Science initiative of the University of Oslo"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Chromatography A"],"published-print":{"date-parts":[[2017,10]]},"DOI":"10.1016\/j.chroma.2017.08.071","type":"journal-article","created":{"date-parts":[[2017,8,31]],"date-time":"2017-08-31T03:46:48Z","timestamp":1504151208000},"page":"104-110","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":24,"special_numbering":"C","title":["An automated and self-cleaning nano liquid chromatography mass spectrometry platform featuring an open tubular multi-hole crystal fiber solid phase extraction column and an open tubular separation column"],"prefix":"10.1016","volume":"1518","author":[{"given":"Meire Ribeiro","family":"da Silva","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ole Kristian","family":"Brandtzaeg","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Tore","family":"Vehus","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fernando Mauro","family":"Lan\u00e7as","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Steven Ray","family":"Wilson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Elsa","family":"Lundanes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.chroma.2017.08.071_bib0005","doi-asserted-by":"crossref","first-page":"938","DOI":"10.1021\/ac061411m","article-title":"Ultratrace LC\/MS proteomic analysis using 10-\u03bcm-id porous layer open tubular poly (styrene-divinylbenzene) capillary columns","volume":"79","author":"Yue","year":"2007","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2017.08.071_bib0010","doi-asserted-by":"crossref","first-page":"2838","DOI":"10.1002\/jssc.201300499","article-title":"Separation optimization of long porous-layer open-tubular columns for nano-LC-MS of limited proteomic samples","volume":"36","author":"Rogeberg","year":"2013","journal-title":"J. Sep. Sci."},{"key":"10.1016\/j.chroma.2017.08.071_bib0015","doi-asserted-by":"crossref","first-page":"1799","DOI":"10.4155\/bio.15.92","article-title":"Nano-LC in proteomics: recent advances and approaches","volume":"7","author":"Wilson","year":"2015","journal-title":"Bioanalysis"},{"key":"10.1016\/j.chroma.2017.08.071_bib0020","doi-asserted-by":"crossref","first-page":"2782","DOI":"10.1016\/j.chroma.2010.02.025","article-title":"Separation of intact proteins on porous layer open tubular (PLOT) columns","volume":"1217","author":"Rogeberg","year":"2010","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2017.08.071_bib0025","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.jpba.2013.05.006","article-title":"On-line solid phase extraction-liquid chromatography, with emphasis on modern bioanalysis and miniaturized systems","volume":"87","author":"Rogeberg","year":"2014","journal-title":"J. Pharm. Biomed. Anal."},{"key":"10.1016\/j.chroma.2017.08.071_bib0030","doi-asserted-by":"crossref","first-page":"e106881","DOI":"10.1371\/journal.pone.0106881","article-title":"Open tubular lab-on-column\/mass spectrometry for targeted proteomics of nanogram sample amounts","volume":"9","author":"Hustoft","year":"2014","journal-title":"PLoS One"},{"key":"10.1016\/j.chroma.2017.08.071_bib0035","doi-asserted-by":"crossref","first-page":"1604","DOI":"10.1002\/elps.200700741","article-title":"Two-dimensional strong cation exchange\/porous layer open tubular\/mass spectrometry for ultratrace proteomic analysis using a 10 (m id poly (styrene-divinylbenzene) porous layer open tubular column with an on-line triphasic trapping column","volume":"29","author":"Luo","year":"2008","journal-title":"Electrophoresis"},{"key":"10.1016\/j.chroma.2017.08.071_bib0040","doi-asserted-by":"crossref","first-page":"37507","DOI":"10.1038\/srep37507","article-title":"Versatile, sensitive liquid chromatography mass spectrometry\u2013implementation of 10\u2009\u03bcm OT columns suitable for small molecules, peptides and proteins","volume":"6","author":"Vehus","year":"2016","journal-title":"Sci. Rep."},{"key":"10.1016\/j.chroma.2017.08.071_bib0045","doi-asserted-by":"crossref","first-page":"10158","DOI":"10.1021\/acs.analchem.6b02713","article-title":"Very high efficiency porous silica layer open-tubular capillary columns produced via in-column Sol\u2013Gel processing","volume":"88","author":"Hara","year":"2016","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2017.08.071_bib0050","doi-asserted-by":"crossref","first-page":"88","DOI":"10.1016\/j.chroma.2012.09.054","article-title":"Synthesis and characterization of new generation open tubular silica capillaries for liquid chromatography","volume":"1265","author":"Forster","year":"2012","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2017.08.071_bib0055","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.chroma.2013.09.059","article-title":"Preparation and kinetic performance assessment of thick film 10\u201320 \u03bcm open tubular silica capillaries in normal phase high pressure liquid chromatography","volume":"1315","author":"Forster","year":"2013","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2017.08.071_bib0060","doi-asserted-by":"crossref","first-page":"30","DOI":"10.1002\/dta.1927","article-title":"Quantitative determination of opioids in whole blood using fully automated dried blood spot desorption coupled to on-line SPE-LC-MS\/MS","volume":"8","author":"Verplaetse","year":"2016","journal-title":"Drug Test. Anal."},{"key":"10.1016\/j.chroma.2017.08.071_bib0065","doi-asserted-by":"crossref","first-page":"2100","DOI":"10.1021\/ac069383v","article-title":"Monolithic materials: promises, challenges, achievements","volume":"78","author":"Svec","year":"2006","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2017.08.071_bib0070","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2015.10.005","article-title":"Wall modified photonic crystal fibre capillaries as porous layer open tubular columns for in-capillary micro-extraction and capillary chromatography","volume":"905","author":"Kazarian","year":"2016","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.chroma.2017.08.071_bib0075","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.trac.2006.11.008","article-title":"Miniaturized sample preparation using a fiber-packed capillary as the medium","volume":"26","author":"Jinno","year":"2007","journal-title":"TrAC Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2017.08.071_bib0080","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.chroma.2017.01.087","article-title":"Chromatographic properties PLOT multicapillary columns","volume":"1488","author":"Nikolaeva","year":"2017","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2017.08.071_bib0085","doi-asserted-by":"crossref","first-page":"3020","DOI":"10.1002\/jssc.201100553","article-title":"Automatic filtration and filter flush for robust online solid-phase extraction liquid chromatography","volume":"34","author":"Svendsen","year":"2011","journal-title":"J. Sep. Sci."},{"key":"10.1016\/j.chroma.2017.08.071_bib0090","doi-asserted-by":"crossref","first-page":"1325","DOI":"10.1007\/s00216-010-3630-y","article-title":"LC-QqLIT MS analysis of nine sulfonamides and one of their acetylated metabolites in the Llobregat River basin. Quantitative determination and qualitative evaluation by IDA experiments","volume":"397","author":"Garc\u00eda-Gal\u00e1n","year":"2010","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.chroma.2017.08.071_bib0095","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/j.envint.2010.11.011","article-title":"Occurrence of sulfonamide residues along the Ebro river basin: removal in wastewater treatment plants and environmental impact assessment","volume":"37","author":"Garc\u00eda-Gal\u00e1n","year":"2011","journal-title":"Environ. Int."},{"key":"10.1016\/j.chroma.2017.08.071_bib0100","doi-asserted-by":"crossref","first-page":"5267","DOI":"10.1021\/jf0605502","article-title":"Development of multiclass methods for drug residues in eggs: hydrophilic solid-phase extraction cleanup and liquid chromatography\/tandem mass spectrometry analysis of tetracycline, fluoroquinolone, sulfonamide, and \u03b2-lactam residues","volume":"54","author":"Heller","year":"2006","journal-title":"J. Agric. Food Chem."},{"key":"10.1016\/j.chroma.2017.08.071_bib0105","doi-asserted-by":"crossref","first-page":"9800","DOI":"10.1021\/jf202705d","article-title":"Development of an immunoaffinity chromatography purification and ultra performance liquid chromatography tandem mass spectrometry method for determination of 12 sulfonamides in beef and milk","volume":"59","author":"Zhao","year":"2011","journal-title":"J. Agric. Food Chem."},{"key":"10.1016\/j.chroma.2017.08.071_bib0110","doi-asserted-by":"crossref","first-page":"1245","DOI":"10.1007\/s00216-012-6511-8","article-title":"Ionic liquid-salt aqueous two-phase extraction based on salting-out coupled with high-performance liquid chromatography for the determination of sulfonamides in water and food","volume":"405","author":"Han","year":"2013","journal-title":"Anal. Bioanal. Chem."},{"key":"10.1016\/j.chroma.2017.08.071_bib0115","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1016\/j.talanta.2011.12.053","article-title":"Determination of six sulfonamide antibiotics, two metabolites and trimethoprim in wastewater by isotope dilution liquid chromatography\/tandem mass spectrometry","volume":"89","author":"Le-Minh","year":"2012","journal-title":"Talanta"},{"key":"10.1016\/j.chroma.2017.08.071_bib0120","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.chroma.2017.03.043","article-title":"Self-packed core shell nano liquid chromatography columns and silica-based monolithic trap columns for targeted proteomics","volume":"1498","author":"Berg","year":"2017","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2017.08.071_bib0125","doi-asserted-by":"crossref","DOI":"10.1038\/srep31693","article-title":"Proteomics tools reveal startlingly high amounts of oxytocin in plasma and serum","volume":"6","author":"Brandtzaeg","year":"2016","journal-title":"Sci. Rep."},{"key":"10.1016\/j.chroma.2017.08.071_bib0130","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/j.chroma.2012.02.002","article-title":"High sensitivity measurements of active oxysterols with automated filtration\/filter backflush-solid phase extraction-liquid chromatography\u2013mass spectrometry","volume":"1255","author":"Roberg-Larsen","year":"2012","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2017.08.071_bib0135","doi-asserted-by":"crossref","first-page":"8168","DOI":"10.1016\/j.chroma.2011.09.022","article-title":"Microproteomic analysis of 10,000 laser captured microdissected breast tumor cells using short-range sodium dodecyl sulfate-polyacrylamide gel electrophoresis and porous layer open tubular liquid chromatography tandem mass spectrometry","volume":"1218","author":"Thakur","year":"2011","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2017.08.071_bib0140","doi-asserted-by":"crossref","first-page":"1419","DOI":"10.1002\/jssc.200401825","article-title":"Organic polymer monoliths as stationary phases for capillary HPLC","volume":"27","author":"Svec","year":"2004","journal-title":"J. Sep. Sci."},{"key":"10.1016\/j.chroma.2017.08.071_bib0145","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1002\/jssc.200401721","article-title":"Preparation and HPLC applications of rigid macroporous organic polymer monoliths","volume":"27","author":"Svec","year":"2004","journal-title":"J. Sep. Sci."},{"key":"10.1016\/j.chroma.2017.08.071_bib0150","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1016\/j.chroma.2008.01.006","article-title":"Characterization of polymer-based monolithic capillary columns by inverse size-exclusion chromatography and mercury-intrusion porosimetry","volume":"1182","author":"Urban","year":"2008","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2017.08.071_bib0155","doi-asserted-by":"crossref","first-page":"537","DOI":"10.1039\/c0ay00649a","article-title":"Monolithic porous layer open tubular (monoPLOT) columns for low pressure liquid chromatography of proteins","volume":"3","author":"Nesterenko","year":"2011","journal-title":"Anal. Methods"},{"key":"10.1016\/j.chroma.2017.08.071_bib0160","doi-asserted-by":"crossref","first-page":"28165","DOI":"10.1039\/C4RA03792H","article-title":"Infrared photo-initiated fabrication of monolithic porous layer open tubular (monoPLOT) capillary columns for chromatographic applications","volume":"4","author":"Collins","year":"2014","journal-title":"RSC Adv."},{"key":"10.1016\/j.chroma.2017.08.071_bib0165","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.aca.2011.06.004","article-title":"Construction and initial evaluation of an apparatus for spatial comprehensive two-dimensional liquid-phase separations","volume":"701","author":"Vanhoutte","year":"2011","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.chroma.2017.08.071_bib0170","doi-asserted-by":"crossref","first-page":"217","DOI":"10.1016\/j.chroma.2003.10.093","article-title":"Isoelectric point separation of proteins by capillary pH-gradient ion-exchange chromatography","volume":"1025","author":"Andersen","year":"2004","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2017.08.071_bib0175","doi-asserted-by":"crossref","DOI":"10.1038\/srep09308","article-title":"Liquid chromatography-mass spectrometry platform for both small neurotransmitters and neuropeptides in blood, with automatic and robust solid phase extraction","volume":"5","author":"Johnsen","year":"2015","journal-title":"Sci. Rep."},{"key":"10.1016\/j.chroma.2017.08.071_bib0180","doi-asserted-by":"crossref","first-page":"355","DOI":"10.1016\/j.talanta.2009.12.009","article-title":"Determination of 19 sulfonamides in environmental water samples by automated on-line solid-phase extraction-liquid chromatography\u2013tandem mass spectrometry (SPE-LC\u2013MS\/MS)","volume":"81","author":"Garc\u00eda-Gal\u00e1n","year":"2010","journal-title":"Talanta"}],"container-title":["Journal of Chromatography A"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021967317312700?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021967317312700?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,8,28]],"date-time":"2018-08-28T07:28:13Z","timestamp":1535441293000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021967317312700"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,10]]},"references-count":36,"alternative-id":["S0021967317312700"],"URL":"https:\/\/doi.org\/10.1016\/j.chroma.2017.08.071","relation":{},"ISSN":["0021-9673"],"issn-type":[{"value":"0021-9673","type":"print"}],"subject":[],"published":{"date-parts":[[2017,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"An automated and self-cleaning nano liquid chromatography mass spectrometry platform featuring an open tubular multi-hole crystal fiber solid phase extraction column and an open tubular separation column","name":"articletitle","label":"Article Title"},{"value":"Journal of Chromatography A","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.chroma.2017.08.071","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}