{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,24]],"date-time":"2026-09-24T11:14:45Z","timestamp":1790248485591,"version":"4.1.0"},"reference-count":29,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2019,2,1]],"date-time":"2019-02-01T00:00:00Z","timestamp":1548979200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"name":"FWO\/FNRS Belgium EOS","award":["30897864"],"award-info":[{"award-number":["30897864"]}]},{"DOI":"10.13039\/501100003130","name":"Research Foundation Flanders","doi-asserted-by":"crossref","award":["FWO \u2013 grant no. 12J6517N"],"award-info":[{"award-number":["FWO \u2013 grant no. 12J6517N"]}],"id":[{"id":"10.13039\/501100003130","id-type":"DOI","asserted-by":"crossref"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Chromatography A"],"published-print":{"date-parts":[[2019,2]]},"DOI":"10.1016\/j.chroma.2018.11.078","type":"journal-article","created":{"date-parts":[[2018,11,30]],"date-time":"2018-11-30T06:09:10Z","timestamp":1543558150000},"page":"52-61","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"special_numbering":"C","title":["Peak sharpening limits of solvent-assisted post-column refocusing to enhance detection limits in liquid chromatography"],"prefix":"10.1016","volume":"1586","author":[{"given":"Vincent","family":"Pepermans","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jelle","family":"De Vos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sebastiaan","family":"Eeltink","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gert","family":"Desmet","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"12","key":"10.1016\/j.chroma.2018.11.078_bib0005","doi-asserted-by":"crossref","first-page":"1640","DOI":"10.1021\/ac60348a053","article-title":"Role of column parameters and injection volume on detection limits in liquid chromatography","volume":"46","author":"Karger","year":"1974","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2018.11.078_bib0010","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1016\/S0021-9673(01)93121-8","article-title":"Effect of organic solvents in sample solutions and injection volumes on chromatographic peak profiles of analytes in reversed-phase high-performance liquid chromatography","volume":"483","author":"Vukmanic","year":"1989","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2018.11.078_bib0015","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/S0021-9673(00)81011-0","article-title":"Two-dimensional column liquid chromatographic technique for resolution of complex mixtures","volume":"149","author":"Erni","year":"1978","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2018.11.078_bib0020","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/S0021-9673(00)82604-7","article-title":"Automated on-line multi-dimensional high-performance liquid chromatographic techniques for the clean-up and analysis of water-soluble samples","volume":"206","author":"Apffel","year":"1981","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2018.11.078_bib0025","doi-asserted-by":"crossref","first-page":"7785","DOI":"10.1016\/j.chroma.2009.09.016","article-title":"Detection issues in two-dimensional on-line chromatography","volume":"1216","author":"Horv\u00e1th","year":"2009","journal-title":"J.Chromatogr. A."},{"key":"10.1016\/j.chroma.2018.11.078_bib0030","doi-asserted-by":"crossref","first-page":"8525","DOI":"10.1021\/ac101420f","article-title":"Comprehensive study on the optimization of online two-dimensional liquid chromatographic systems considering losses in theoretical peak capacity in first- and second-dimensions: a pareto-optimality approach","volume":"82","author":"Viv\u00f3-Truyols","year":"2010","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2018.11.078_bib0035","doi-asserted-by":"crossref","first-page":"7648","DOI":"10.1016\/j.chroma.2010.09.023","article-title":"Targeted three-dimensional liquid chromatography: a versatile tool for quantitative trace analysis in complex matrices","volume":"1217","author":"Simpkins","year":"2010","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2018.11.078_bib0040","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/j.chroma.2011.06.035","article-title":"Selective comprehensive multi-dimensional separation for resolution enhancement in high performance liquid chromatography. Part I: Principles and instrumentation","volume":"1228","author":"Groskreutz","year":"2012","journal-title":"J. Chromatogr. A."},{"issue":"3","key":"10.1016\/j.chroma.2018.11.078_bib0045","doi-asserted-by":"crossref","first-page":"1785","DOI":"10.1021\/acs.analchem.5b04051","article-title":"Reducing dilution and analysis time in online comprehensive two-dimensional liquid chromatography by active modulation","volume":"88","author":"Gargano","year":"2016","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2018.11.078_bib0050","doi-asserted-by":"crossref","first-page":"190","DOI":"10.1007\/BF02491569","article-title":"Sensitivity enhancement in capillary electrochromatography by on-column preconcentration","volume":"53","author":"Hilhorst","year":"2000","journal-title":"Chromatographia"},{"issue":"5","key":"10.1016\/j.chroma.2018.11.078_bib0055","first-page":"268","article-title":"The modulator in comprehensive two-dimensional liquid chromatography","volume":"29","author":"Egeness","year":"2016","journal-title":"LCGC Europe"},{"issue":"18","key":"10.1016\/j.chroma.2018.11.078_bib0060","doi-asserted-by":"crossref","first-page":"7053","DOI":"10.1021\/ac201207t","article-title":"Thermal modulation for multidimensional liquid chromatography separations using low-thermal-mass liquid chromatography (LC)","volume":"83","author":"Verstraeten","year":"2011","journal-title":"Anal. Chem."},{"issue":"12\u201313","key":"10.1016\/j.chroma.2018.11.078_bib0065","doi-asserted-by":"crossref","first-page":"1147","DOI":"10.1002\/jssc.200301500","article-title":"Novel column oven concept for cold spot large volume sample enrichment in high throughput temperature gradient capillary liquid chromatography","volume":"26","author":"Holm","year":"2003","journal-title":"J. Sep. Sci."},{"key":"10.1016\/j.chroma.2018.11.078_bib0070","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1021\/acs.analchem.6b03279","article-title":"Longitudinal on-column thermal modulation for comprehensive two-dimensional liquid chromatography","volume":"89","author":"Creese","year":"2017","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2018.11.078_bib0075","doi-asserted-by":"crossref","first-page":"5112","DOI":"10.1021\/acs.analchem.5b04793","article-title":"Improving the sensitivity, resolution, and peak capacity of gradient elution in capillary liquid chromatography with large-volume injections by using temperature-assisted on-column solute focusing","volume":"88","author":"Wilson","year":"2016","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2018.11.078_bib0080","doi-asserted-by":"crossref","first-page":"90","DOI":"10.1016\/j.chroma.2015.11.082","article-title":"Switching solvent and enhancing analyte concentrations in small effluent fractions using in-column focusing","volume":"1427","author":"van de Ven","year":"2016","journal-title":"J. Chromatogr. A"},{"issue":"4","key":"10.1016\/j.chroma.2018.11.078_bib0085","doi-asserted-by":"crossref","first-page":"2031","DOI":"10.1021\/ac203252u","article-title":"Exploring the possibilities of cryogenic cooling in liquid chromatography for biological applications: a proof of principle","volume":"84","author":"Eghbali","year":"2012","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2018.11.078_bib0090","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.chroma.2014.07.072","article-title":"A generic approach to post-column refocusing in liquid chromatography","volume":"1360","author":"De Vos","year":"2014","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2018.11.078_bib0095","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.chroma.2014.12.082","article-title":"Peak refocusing using subsequent retentive trapping and strong eluent remobilization in liquid chromatography: a theoretical optimization study","volume":"1381","author":"De Vos","year":"2015","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2018.11.078_bib0100","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0009-5907(65)80002-3","article-title":"Principles of gradient elution","volume":"7","author":"Snyder","year":"1965","journal-title":"Chromatogr. Rev."},{"key":"10.1016\/j.chroma.2018.11.078_bib0105","doi-asserted-by":"crossref","first-page":"77","DOI":"10.1016\/S0021-9673(00)81641-6","article-title":"Peak width in solvent-programmed chromatography: I. General description of peak broadening in solvent-programmed elution","volume":"204","author":"Poppe","year":"1981","journal-title":"J. Chromatogr."},{"key":"10.1016\/j.chroma.2018.11.078_bib0110","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/S0021-9673(00)94850-7","article-title":"Zone compression effects in high-performance liquid chromatography","volume":"367","author":"Hsu","year":"1986","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2018.11.078_bib0115","doi-asserted-by":"crossref","first-page":"116","DOI":"10.1016\/j.chroma.2015.07.038","article-title":"Quantitative evaluation of models for solvent-based, on-column focusing in liquid chromatography","volume":"1409","author":"Groskreutz","year":"2015","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2018.11.078_bib0120","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/S0021-9673(96)00753-4","article-title":"Assessment of injection volume limits when using on-column focusing with microbore liquid chromatography","volume":"759","author":"Mills","year":"1997","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2018.11.078_bib0125","doi-asserted-by":"crossref","first-page":"32","DOI":"10.1016\/j.chroma.2006.01.104","article-title":"Peak compression in reversed-phase gradient elution","volume":"1111","author":"Neue","year":"2006","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2018.11.078_bib0130","doi-asserted-by":"crossref","first-page":"189","DOI":"10.1007\/s10337-013-2556-x","article-title":"Theory of gradient elution liquid chromatography with linear solvent strength: Part 2. peak width formation","volume":"77","author":"Blumberg","year":"2014","journal-title":"Chromatography"},{"key":"10.1016\/j.chroma.2018.11.078_bib0135","series-title":"Numerical Analysis","first-page":"888","author":"Burden","year":"1997"},{"key":"10.1016\/j.chroma.2018.11.078_bib0140","series-title":"Numerical Simulations of Heat Transfer and Fluid Flow on a Personal Computer","first-page":"341","author":"Kotake","year":"1993"},{"key":"10.1016\/j.chroma.2018.11.078_bib0145","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.chroma.2016.03.016","article-title":"Effect of pre- and post-column band broadening on the performance of high-speed chromatography columns under isocratic and gradient conditions","volume":"1442","author":"Vanderlinden","year":"2016","journal-title":"J. Chromatogr. A"}],"container-title":["Journal of Chromatography A"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021967318315036?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021967318315036?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,1,29]],"date-time":"2019-01-29T11:26:51Z","timestamp":1548761211000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021967318315036"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,2]]},"references-count":29,"alternative-id":["S0021967318315036"],"URL":"https:\/\/doi.org\/10.1016\/j.chroma.2018.11.078","relation":{},"ISSN":["0021-9673"],"issn-type":[{"value":"0021-9673","type":"print"}],"subject":[],"published":{"date-parts":[[2019,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Peak sharpening limits of solvent-assisted post-column refocusing to enhance detection limits in liquid chromatography","name":"articletitle","label":"Article Title"},{"value":"Journal of Chromatography A","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.chroma.2018.11.078","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}