{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T04:17:22Z","timestamp":1783138642770,"version":"3.54.6"},"reference-count":51,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T00:00:00Z","timestamp":1777507200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100001871","name":"Fundacao para a Ciencia e a Tecnologia","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001871","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Chromatography A"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.chroma.2026.467055","type":"journal-article","created":{"date-parts":[[2026,4,30]],"date-time":"2026-04-30T15:47:43Z","timestamp":1777564063000},"page":"467055","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Sustainable depletion of high-abundance serum proteins using aqueous biphasic systems based on glycine-betaine analogue ionic liquids for the detection of masked biomarkers"],"prefix":"10.1016","volume":"1780","author":[{"given":"Matheus M.","family":"Pereira","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-9483-0686","authenticated-orcid":false,"given":"S\u00f3nia N.","family":"Pedro","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6735-5437","authenticated-orcid":false,"given":"Francisca A.","family":"e Silva","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aminou","family":"Mohamadou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3841-743X","authenticated-orcid":false,"given":"Jo\u00e3o A.P.","family":"Coutinho","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8895-0614","authenticated-orcid":false,"given":"Mara G.","family":"Freire","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.chroma.2026.467055_bib0001","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1016\/j.trsl.2012.01.023","article-title":"Biomarkers: hopes and challenges in the path from discovery to clinical practice","volume":"159","author":"Frangogiannis","year":"2012","journal-title":"Transl. Res."},{"key":"10.1016\/j.chroma.2026.467055_bib0002","article-title":"Proteomics: challenges, techniques and possibilities to overcome biological sample complexity","volume":"1","author":"Chandramouli","year":"2009","journal-title":"Hum. Genom. Proteom."},{"key":"10.1016\/j.chroma.2026.467055_bib0003","doi-asserted-by":"crossref","first-page":"249","DOI":"10.1002\/elps.200800639","article-title":"Liquid-phase-based separation systems for depletion, prefractionation and enrichment of proteins in biological fluids for in-depth proteomics analysis","volume":"30","author":"Jmeian","year":"2009","journal-title":"Electrophoresis"},{"key":"10.1016\/j.chroma.2026.467055_bib0004","doi-asserted-by":"crossref","first-page":"182","DOI":"10.1602\/neurorx.1.2.182","article-title":"Biomarkers: potential uses and limitations","volume":"1","author":"Mayeux","year":"2004","journal-title":"NeuroRx"},{"key":"10.1016\/j.chroma.2026.467055_bib0005","doi-asserted-by":"crossref","first-page":"845","DOI":"10.1074\/mcp.R200007-MCP200","article-title":"The human plasma proteome: history, character, and diagnostic prospects","volume":"1","author":"Anderson","year":"2002","journal-title":"Mol. Cell. Proteom."},{"key":"10.1016\/j.chroma.2026.467055_bib0006","first-page":"57","article-title":"Changes in serum N-glycosylation profiles: functional significance and potential for diagnostics","volume":"37","author":"Mari\u00f1o","year":"2011","journal-title":"Carbohydr. Chem."},{"key":"10.1016\/j.chroma.2026.467055_bib0007","doi-asserted-by":"crossref","first-page":"2963","DOI":"10.1039\/C4CS00370E","article-title":"Cancer biomarker detection: recent achievements and challenges","volume":"44","author":"Wu","year":"2015","journal-title":"Chem. Soc. Rev."},{"key":"10.1016\/j.chroma.2026.467055_bib0008","doi-asserted-by":"crossref","first-page":"740","DOI":"10.1039\/C5AN01790D","article-title":"Biomarker detection technologies and future directions","volume":"141","author":"Nimse","year":"2016","journal-title":"Analyst"},{"key":"10.1016\/j.chroma.2026.467055_bib0009","doi-asserted-by":"crossref","first-page":"1799","DOI":"10.4155\/bio-2019-0145","article-title":"Plasma\/serum proteomics: depletion strategies for reducing high-abundance proteins for biomarker discovery","volume":"11","author":"Lee","year":"2019","journal-title":"Bioanalysis"},{"key":"10.1016\/j.chroma.2026.467055_bib0010","doi-asserted-by":"crossref","first-page":"305","DOI":"10.4149\/gpb_2019009","article-title":"A comparison of albumin removal procedures for proteomic analysis of blood plasma","volume":"38","author":"Tomascova","year":"2019","journal-title":"Gen. Physiol. Biophys."},{"key":"10.1016\/j.chroma.2026.467055_bib0011","doi-asserted-by":"crossref","first-page":"985","DOI":"10.1016\/j.talanta.2008.07.055","article-title":"An aqueous two-phase system as a strategy for serum albumin depletion","volume":"77","author":"da Silva","year":"2009","journal-title":"Talanta"},{"key":"10.1016\/j.chroma.2026.467055_bib0012","doi-asserted-by":"crossref","first-page":"12144","DOI":"10.1039\/D4CC02663B","article-title":"Aqueous two-phase systems \u2013 versatile and advanced (bio)process engineering tools","volume":"60","author":"Jorge","year":"2024","journal-title":"Chem. Commun."},{"key":"10.1016\/j.chroma.2026.467055_bib0013","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/0009-8981(94)90140-6","article-title":"Separation of alkaline phosphatase isoforms with and without intact glycan-phosphatidylinositol anchors in aqueous polymer phase systems","volume":"227","author":"Raymond","year":"1994","journal-title":"Clin. Chim. Acta."},{"key":"10.1016\/j.chroma.2026.467055_bib0014","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0142654","article-title":"An aqueous two-phase system for the concentration and extraction of proteins from the interface for detection using the lateral-flow immunoassay","volume":"10","author":"Chiu","year":"2015","journal-title":"PLoS One"},{"key":"10.1016\/j.chroma.2026.467055_bib0015","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1142\/S2339547814500150","article-title":"Aqueous two-phase systems enable multiplexing of homogeneous immunoassays","volume":"02","author":"Simon","year":"2014","journal-title":"Technology"},{"key":"10.1016\/j.chroma.2026.467055_bib0016","doi-asserted-by":"crossref","first-page":"4878","DOI":"10.1038\/srep04878","article-title":"Aqueous two-phase system patterning of detection antibody solutions for cross-reaction-free multiplex ELISA","volume":"4","author":"Frampton","year":"2014","journal-title":"Sci. Rep."},{"key":"10.1016\/j.chroma.2026.467055_bib0017","article-title":"Isolation of high-purity extracellular vesicles by extracting proteins using aqueous two-phase system","volume":"10","author":"Kim","year":"2015","journal-title":"PLoS One"},{"key":"10.1016\/j.chroma.2026.467055_bib0018","article-title":"Aqueous two-phase system to isolate extracellular vesicles from urine for prostate cancer diagnosis","volume":"13","author":"Shin","year":"2018","journal-title":"PLoS One"},{"key":"10.1016\/j.chroma.2026.467055_bib0019","doi-asserted-by":"crossref","DOI":"10.1038\/srep13103","article-title":"High-yield isolation of extracellular vesicles using aqueous two-phase system","volume":"5","author":"Shin","year":"2015","journal-title":"Sci. Rep."},{"key":"10.1016\/j.chroma.2026.467055_bib0020","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1080\/15422119.2017.1279628","article-title":"Recent advances in protein extraction using ionic liquid-based aqueous two-phase systems, Sep","volume":"46","author":"Lee","year":"2017","journal-title":"Purif. Rev."},{"key":"10.1016\/j.chroma.2026.467055_bib0021","doi-asserted-by":"crossref","DOI":"10.1016\/j.seppur.2023.124248","article-title":"Tailored pretreatment of serum samples and biomarker extraction afforded by ionic liquids as constituents of aqueous biphasic systems","volume":"322","author":"Rosa","year":"2023","journal-title":"Sep. Purif. Technol."},{"key":"10.1016\/j.chroma.2026.467055_bib0022","doi-asserted-by":"crossref","first-page":"2941","DOI":"10.1039\/c2gc35890e","article-title":"Design of environmentally friendly ionic liquid aqueous two-phase systems for the efficient and high activity extraction of proteins","volume":"14","author":"Li","year":"2012","journal-title":"Green Chem."},{"key":"10.1016\/j.chroma.2026.467055_bib0023","doi-asserted-by":"crossref","DOI":"10.1016\/j.fluid.2019.112373","article-title":"Aqueous biphasic systems of amino acid-based ionic liquids: evaluation of phase behavior and extraction capability for caffeine","volume":"506","author":"Basaiahgari","year":"2020","journal-title":"Fluid Phase Equilib"},{"key":"10.1016\/j.chroma.2026.467055_bib0024","doi-asserted-by":"crossref","DOI":"10.1016\/j.trac.2022.116530","article-title":"The ten principles of green sample preparation","volume":"148","author":"L\u00f3pez-Lorente","year":"2022","journal-title":"TrAC Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467055_bib0025","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.trac.2015.11.006","article-title":"Natural designer solvents for greening analytical chemistry","volume":"76","author":"Espino","year":"2016","journal-title":"TrAC Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467055_bib0026","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1007\/s12551-021-00782-0","article-title":"Cholinium amino acid-based ionic liquids","volume":"13","author":"Le Donne","year":"2021","journal-title":"Biophys. Rev."},{"key":"10.1016\/j.chroma.2026.467055_bib0027","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.fluid.2019.05.001","article-title":"Synthesis and characterization of analogues of glycine-betaine ionic liquids and their use in the formation of aqueous biphasic systems","volume":"494","author":"Pereira","year":"2019","journal-title":"Fluid Phase Equilib"},{"key":"10.1016\/j.chroma.2026.467055_bib0028","doi-asserted-by":"crossref","first-page":"1205","DOI":"10.1002\/btpr.2685","article-title":"Glycine-betaine ionic liquid analogues as novel phase-forming components of aqueous biphasic systems","volume":"34","author":"Pereira","year":"2018","journal-title":"Biotechnol. Prog."},{"key":"10.1016\/j.chroma.2026.467055_bib0029","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/j.gce.2021.01.004","article-title":"Revisiting greenness of ionic liquids and deep eutectic solvents","volume":"2","author":"Chen","year":"2021","journal-title":"Green Chem. Eng."},{"key":"10.1016\/j.chroma.2026.467055_bib0030","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.gce.2021.11.008","article-title":"Principles and strategies for green process engineering","volume":"3","author":"Zhang","year":"2022","journal-title":"Green Chem. Eng."},{"key":"10.1016\/j.chroma.2026.467055_bib0031","doi-asserted-by":"crossref","first-page":"10076","DOI":"10.1021\/acs.analchem.0c01887","article-title":"AGREE\u2014Analytical GREEnness metric approach and software","volume":"92","author":"Pena-Pereira","year":"2020","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467055_bib0032","doi-asserted-by":"crossref","DOI":"10.1016\/j.trac.2022.116553","article-title":"AGREEprep \u2013 Analytical greenness metric for sample preparation","volume":"149","author":"Wojnowski","year":"2022","journal-title":"TrAC Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467055_bib0033","doi-asserted-by":"crossref","first-page":"7598","DOI":"10.1039\/D3GC02347H","article-title":"Blue applicability grade index (BAGI) and software: a new tool for the evaluation of method practicality","volume":"25","author":"Manousi","year":"2023","journal-title":"Green Chem"},{"key":"10.1016\/j.chroma.2026.467055_bib0034","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.trac.2013.04.010","article-title":"The 12 principles of green analytical chemistry and the SIGNIFICANCE mnemonic of green analytical practices","volume":"50","author":"Ga\u0142uszka","year":"2013","journal-title":"TrAC Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467055_bib0035","doi-asserted-by":"crossref","DOI":"10.1016\/j.trac.2021.116223","article-title":"White Analytical Chemistry: an approach to reconcile the principles of Green Analytical Chemistry and functionality","volume":"138","author":"Nowak","year":"2021","journal-title":"TrAC Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467055_bib0036","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.molliq.2013.04.023","article-title":"Syntheses and characterisation of hydrophobic ionic liquids containing trialkyl(2-ethoxy-2-oxoethyl)ammonium or N-(1-methylpyrrolidyl-2-ethoxy-2- oxoethyl)ammonium cations","volume":"184","author":"Messadi","year":"2013","journal-title":"J. Mol. Liq."},{"key":"10.1016\/j.chroma.2026.467055_bib0037","series-title":"Microtox\u00ae Manual. A Toxicity Testing Handbook","year":"1992"},{"key":"10.1016\/j.chroma.2026.467055_bib0038","first-page":"1857","article-title":"Aqueous two-phase systems for protein separation studies on phase inversion","volume":"45","author":"Merchuk","year":"2016","journal-title":"J. Chromatogr. B Anal. Technol. Biomed. Life Sci."},{"key":"10.1016\/j.chroma.2026.467055_bib0039","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.fluid.2016.01.004","article-title":"Modeling of the binodal curve of ionic liquid\/salt aqueous systems","volume":"426","author":"Alvarez-Guerra","year":"2016","journal-title":"Fluid Phase Equilib"},{"key":"10.1016\/j.chroma.2026.467055_bib0040","series-title":"Essentials of Medical Biochemistry","first-page":"511","article-title":"Metabolism of iron and heme","author":"Bhagavan","year":"2015"},{"key":"10.1016\/j.chroma.2026.467055_bib0041","doi-asserted-by":"crossref","first-page":"1170","DOI":"10.1039\/b711119c","article-title":"Effects of different head groups and functionalised side chains on the aquatic toxicity of ionic liquids","volume":"9","author":"Stolte","year":"2007","journal-title":"Green Chem."},{"key":"10.1016\/j.chroma.2026.467055_bib0042","doi-asserted-by":"crossref","first-page":"6150","DOI":"10.1016\/j.tet.2013.05.054","article-title":"Biomass derived ionic liquids: synthesis from natural organic acids, characterization, toxicity, biodegradation and use as solvents for catalytic hydrogenation processes","volume":"69","author":"Ferlin","year":"2013","journal-title":"Tetrahedron"},{"key":"10.1016\/j.chroma.2026.467055_bib0044","doi-asserted-by":"crossref","first-page":"162","DOI":"10.1016\/j.ecoenv.2011.10.006","article-title":"Toxicity assessment of various ionic liquid families towards Vibrio fischeri marine bacteria","volume":"76","author":"Ventura","year":"2012","journal-title":"Ecotoxicol. Environ. Saf."},{"key":"10.1016\/j.chroma.2026.467055_bib0045","doi-asserted-by":"crossref","first-page":"301","DOI":"10.1042\/bj1570301","article-title":"Isolation of albumin from whole human plasma and fractionation of albumin depleted plasma","volume":"157","author":"Travis","year":"1976","journal-title":"Biochem. J."},{"key":"10.1016\/j.chroma.2026.467055_bib0046","doi-asserted-by":"crossref","first-page":"129","DOI":"10.1186\/1475-2875-7-129","article-title":"Evaluation of immunoglobulin purification methods and their impact on quality and yield of antigen-specific antibodies","volume":"7","author":"Bergmann-Leitner","year":"2008","journal-title":"Malar. J."},{"key":"10.1016\/j.chroma.2026.467055_bib0047","doi-asserted-by":"crossref","first-page":"1765","DOI":"10.1016\/j.dib.2018.06.042","article-title":"A human proteomic dataset from untreated and depleted\/enriched serum samples","volume":"19","author":"Pisanu","year":"2018","journal-title":"Data Br"},{"key":"10.1016\/j.chroma.2026.467055_bib0048","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1016\/j.jsps.2015.01.023","article-title":"Comparison of different serum sample extraction methods and their suitability for mass spectrometry analysis","volume":"23","author":"Alshammari","year":"2015","journal-title":"Saudi Pharm. J."},{"key":"10.1016\/j.chroma.2026.467055_bib0049","year":"2018","journal-title":"Bioanal. Method Valid."},{"key":"10.1016\/j.chroma.2026.467055_bib0050","series-title":"Advances in Clinical Chemistry","first-page":"71","article-title":"Transferrin saturation: a body iron biomarker","author":"Elsayed","year":"2016"},{"key":"10.1016\/j.chroma.2026.467055_bib0051","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1016\/j.jchromb.2012.06.006","article-title":"Quantification of human serum transferrin using liquid chromatography-tandem mass spectrometry based targeted proteomics","volume":"902","author":"Yu","year":"2012","journal-title":"J. Chromatogr. B Anal. Technol. Biomed. Life Sci."},{"key":"10.1016\/j.chroma.2026.467055_bib0052","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/10408347.2020.1743639","article-title":"A review of properties, delivery systems and analytical methods for the characterization of monomeric glycoprotein transferrin","author":"Fernandes","year":"2020","journal-title":"Crit. Rev. Anal. Chem."}],"container-title":["Journal of Chromatography A"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021967326003857?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021967326003857?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,7,4]],"date-time":"2026-07-04T03:32:06Z","timestamp":1783135926000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021967326003857"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":51,"alternative-id":["S0021967326003857"],"URL":"https:\/\/doi.org\/10.1016\/j.chroma.2026.467055","relation":{},"ISSN":["0021-9673"],"issn-type":[{"value":"0021-9673","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Sustainable depletion of high-abundance serum proteins using aqueous biphasic systems based on glycine-betaine analogue ionic liquids for the detection of masked biomarkers","name":"articletitle","label":"Article Title"},{"value":"Journal of Chromatography A","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.chroma.2026.467055","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"467055"}}