{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,27]],"date-time":"2026-09-27T19:17:30Z","timestamp":1790536650706,"version":"4.1.0"},"reference-count":24,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Chromatography A"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.chroma.2026.467385","type":"journal-article","created":{"date-parts":[[2026,8,24]],"date-time":"2026-08-24T06:16:15Z","timestamp":1787552175000},"page":"467385","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Centrifugal mini-SPE cleanup for monitoring contaminants in food. Part I: Comparison with dispersive-SPE"],"prefix":"10.1016","volume":"1787","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-5934-7469","authenticated-orcid":false,"given":"Steven J.","family":"Lehotay","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-8967-9621","authenticated-orcid":false,"given":"Bunhong","family":"Lai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.chroma.2026.467385_bib0001","series-title":"Handbook of GC-MS: Fundamentals and Applications","first-page":"928","author":"H\u00fcbschmann","year":"2025"},{"key":"10.1016\/j.chroma.2026.467385_bib0002","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/j.aca.2019.02.036","article-title":"QuEChERS \u2013 Fundamentals, relevant improvements, applications and future trends","volume":"1070","author":"Perestrelo","year":"2019","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.chroma.2026.467385_bib0003","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1016\/j.trac.2015.08.014","article-title":"Solid-phase extraction of organic compounds: a critical review (Part I)","volume":"80","author":"Andrade-Eiroa","year":"2016","journal-title":"Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467385_bib0004","doi-asserted-by":"crossref","first-page":"1252","DOI":"10.1093\/jaoac\/78.5.1252","article-title":"Multiresidue determination of pesticides in fruit and vegetables by gas chromatography mass-selective detection and liquid chromatography with fluoresence detection","volume":"78","author":"Fillion","year":"1995","journal-title":"J. AOAC Int."},{"key":"10.1016\/j.chroma.2026.467385_bib0005","first-page":"972","article-title":"Evaluation of QuEChERS, cartridge SPE cleanup, and gas chromatography time-of-flight mass spectrometry for the analysis of pesticides in dietary supplements","volume":"28","author":"Kowalski","year":"2010","journal-title":"LCGC N. Am."},{"key":"10.1016\/j.chroma.2026.467385_bib0006","doi-asserted-by":"crossref","first-page":"982","DOI":"10.1039\/C4AY01867B","article-title":"Evaluation of dispersive and cartridge SPE clean-up procedures using the modified QuEChERS method for the analysis of pesticides in strawberries","volume":"7","author":"Oshita","year":"2015","journal-title":"Anal. Methods"},{"key":"10.1016\/j.chroma.2026.467385_bib0007","doi-asserted-by":"crossref","first-page":"4328","DOI":"10.1039\/D6AN00462H","article-title":"Automated offline \u00b5-SPE cleanup in GC-based multi-residue analysis: overcoming the challenges of fatty acid containing matrices","volume":"151","author":"Aloisi","year":"2026","journal-title":"Analyst"},{"key":"10.1016\/j.chroma.2026.467385_bib0008","doi-asserted-by":"crossref","DOI":"10.1002\/jssc.202300571","article-title":"Matrix effects demystified: strategies for resolving challenges in analytical separations of complex samples","volume":"46","author":"Williams","year":"2023","journal-title":"J. Sep. Sci."},{"key":"10.1016\/j.chroma.2026.467385_bib0009","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1038\/s43586-024-00379-3","article-title":"Comprehensive two-dimensional gas chromatography-mass spectrometry","volume":"5","author":"Mondello","year":"2025","journal-title":"Nat. Rev. Methods Primers"},{"key":"10.1016\/j.chroma.2026.467385_bib0010","article-title":"Review on atmospheric pressure ionization sources for gas chromatography-mass spectrometry. Part I: current ion source developments and improvements in ionization strategies","volume":"1238","author":"Ayala-Cabrera","year":"2023","journal-title":"Anal. Chim. Acta"},{"key":"10.1016\/j.chroma.2026.467385_bib0011","doi-asserted-by":"crossref","DOI":"10.1016\/j.trac.2019.04.007","article-title":"Capillary gas chromatography-mass spectrometry: current trends and perspectives","volume":"124","author":"Gruber","year":"2020","journal-title":"Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467385_bib0012","first-page":"22","article-title":"Overview of the evolution and trends of the QuEChERS sample preparation procedure","volume":"262","author":"Veiga-del-Ba\u00f1o","year":"2024","journal-title":"Rev. Environ. Contam. Toxicol."},{"key":"10.1016\/j.chroma.2026.467385_bib0013","doi-asserted-by":"crossref","first-page":"5107","DOI":"10.1021\/jf505539e","article-title":"Development of an automated column solid-phase extraction cleanup of QuEChERS extracts using zirconia-based sorbent, for pesticide residue analysis by LC-MS\/MS","volume":"63","author":"Morris","year":"2015","journal-title":"J. Agric. Food Chem."},{"key":"10.1016\/j.chroma.2026.467385_bib0014","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1007\/s10337-016-3116-y","article-title":"Automated mini-column solid-phase extraction cleanup for high-throughput analysis of chemical contaminants in foods by low-pressure gas chromatography\u2014tandem mass spectrometry","volume":"79","author":"Lehotay","year":"2016","journal-title":"Chromatographia"},{"key":"10.1016\/j.chroma.2026.467385_bib0015","doi-asserted-by":"crossref","DOI":"10.1016\/j.chroma.2022.463596","article-title":"Evaluation of a septumless mini-cartridge for automated solid-phase extraction cleanup in gas chromatographic analysis of >250 pesticides and environmental contaminants in fatty and nonfatty foods","volume":"1685","author":"Michlig","year":"2022","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2026.467385_bib0016","doi-asserted-by":"crossref","DOI":"10.1016\/j.chroma.2025.465882","article-title":"Use of a centrifuge in solid-phase extraction is a valid platform for cleanup in the high-throughput analysis of chemical contaminants in nonfatty and fatty foods","volume":"1749","author":"Michlig","year":"2025","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2026.467385_bib0017","doi-asserted-by":"crossref","first-page":"3709","DOI":"10.1039\/D3AY00612C","article-title":"Comparison of recovery efficiency and matrix effect reduction in pesticide residue analysis: quEChERS with d-SPE, SPE, and FaPEx in apples and Korean cabbage","volume":"15","author":"Lee","year":"2023","journal-title":"Anal. Methods"},{"key":"10.1016\/j.chroma.2026.467385_bib0018","doi-asserted-by":"crossref","first-page":"2761","DOI":"10.1039\/D2AY00713D","article-title":"Analysis of pesticides, veterinary drugs, and environmental contaminants in goat and Lamb by the QuEChERSER mega-method","volume":"14","author":"Ninga","year":"2022","journal-title":"Anal. Methods"},{"key":"10.1016\/j.chroma.2026.467385_bib0019","unstructured":"S.J. Lehotay, P. Greene, L. Vaclavik, J. Schmitz, Centrifugal mini-SPE cleanup for monitoring contaminants in food. Part II: sorbents capacity, quantification, and comparison of lots, J. Chromatogr. A (submitted)."},{"key":"10.1016\/j.chroma.2026.467385_bib0020","doi-asserted-by":"crossref","DOI":"10.1016\/j.trac.2020.115957","article-title":"Advanced gas chromatography and mass spectrometry technologies for fatty acids and triaglycerols analysis","volume":"129","author":"Waktola","year":"2020","journal-title":"Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467385_bib0021","doi-asserted-by":"crossref","first-page":"223","DOI":"10.1007\/BF02269707","article-title":"M. S. Tswett and the discovery of chromatography I: early work (1899-1903)","volume":"35","author":"Ettre","year":"1993","journal-title":"Chromatographia"},{"key":"10.1016\/j.chroma.2026.467385_bib0022","doi-asserted-by":"crossref","first-page":"5599","DOI":"10.1039\/D4AY00858H","article-title":"Comparison of different fast chromatography \u2013 mass spectrometry techniques (Cold EI, MS\/MS, and HRMS) for the analysis of pyrethroid insecticide residues in food","volume":"16","author":"Michlig","year":"2024","journal-title":"Anal. Methods"},{"key":"10.1016\/j.chroma.2026.467385_bib0023","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1093\/jaoacint\/qsae093","article-title":"Validation of the QuEChERSER method for 245 pesticides and environmental contaminants in barley and hemp by low-pressure GC: comparison of triple quadrupole MS\/MS and orbitrap HRMS for qualitative and quantitative analysis","volume":"109","author":"Michlig","year":"2026","journal-title":"J. AOAC Int."},{"key":"10.1016\/j.chroma.2026.467385_bib0024","doi-asserted-by":"crossref","DOI":"10.1016\/j.chroma.2020.461596","article-title":"Critical review and re-assessment of analyte protectants in gas chromatography","volume":"1632","author":"Rodr\u00edguez-Ramos","year":"2020","journal-title":"J. Chromatogr. A"}],"container-title":["Journal of Chromatography A"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021967326007120?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021967326007120?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T12:22:38Z","timestamp":1790425358000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021967326007120"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":24,"alternative-id":["S0021967326007120"],"URL":"https:\/\/doi.org\/10.1016\/j.chroma.2026.467385","relation":{},"ISSN":["0021-9673"],"issn-type":[{"value":"0021-9673","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Centrifugal mini-SPE cleanup for monitoring contaminants in food. Part I: Comparison with dispersive-SPE","name":"articletitle","label":"Article Title"},{"value":"Journal of Chromatography A","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.chroma.2026.467385","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"467385"}}