{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T12:59:03Z","timestamp":1790427543976,"version":"4.1.0"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T00:00:00Z","timestamp":1788307200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100020994","name":"CNES Toulouse","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100020994","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Journal of Chromatography A"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.chroma.2026.467419","type":"journal-article","created":{"date-parts":[[2026,9,2]],"date-time":"2026-09-02T06:44:18Z","timestamp":1788331458000},"page":"467419","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Lab-on-chip column for space missions\u2019 application: design optimization of fluidic interface and column inlet-outlet to combine test reliability and maximum efficiency"],"prefix":"10.1016","volume":"1787","author":[{"given":"Malak","family":"Rizk-Bigourd","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Audrey","family":"Boco-Simon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lylia","family":"Skander","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Gabin","family":"Bergerot","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Arnaud","family":"Philippart","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Val\u00e9rie","family":"Agasse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Pascal","family":"Cardinael","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cyril","family":"Szopa","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.chroma.2026.467419_bib0001","doi-asserted-by":"crossref","first-page":"686","DOI":"10.1016\/S0165-9936(02)00805-1","article-title":"Application of gas chromatography in food analysis","volume":"21","author":"Lehotay","year":"2002","journal-title":"TrAC Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467419_bib0002","doi-asserted-by":"crossref","first-page":"672","DOI":"10.1016\/S0165-9936(02)00813-0","article-title":"The application of gas chromatography to environmental analysis","volume":"21","author":"Santos","year":"2002","journal-title":"TrAC Trends Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467419_bib0003","series-title":"Basic Biotechniques for Bioprocess and Bioentrepreneurship","first-page":"173","article-title":"Chapter 10 - chromatography: basic principle, types, and applications","author":"Gupta","year":"2023"},{"key":"10.1016\/j.chroma.2026.467419_bib0004","doi-asserted-by":"crossref","first-page":"7891","DOI":"10.1029\/JA085iA13p07891","article-title":"Pioneer Venus gas chromatography of the lower atmosphere of venus","volume":"85","author":"Oyama","year":"1980","journal-title":"J. Geophys. Res. Space Phys."},{"key":"10.1016\/j.chroma.2026.467419_bib0005","doi-asserted-by":"crossref","first-page":"353","DOI":"10.1016\/S0273-1177(98)00193-8","article-title":"An exobiological view of Titan and the Cassini-Huygens mission","volume":"22","author":"Raulin","year":"1998","journal-title":"Adv. Space Res."},{"key":"10.1016\/j.chroma.2026.467419_bib0006","doi-asserted-by":"crossref","first-page":"817","DOI":"10.1063\/1.1135623","article-title":"Viking gas chromatograph\u2013mass spectrometer","volume":"49","author":"Rushneck","year":"1978","journal-title":"Rev. Sci. Instrum."},{"key":"10.1016\/j.chroma.2026.467419_bib0007","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1007\/s11214-012-9879-z","article-title":"The sample analysis at mars investigation and instrument suite","volume":"170","author":"Mahaffy","year":"2012","journal-title":"Space Sci. Rev."},{"key":"10.1016\/j.chroma.2026.467419_bib0008","doi-asserted-by":"crossref","first-page":"165","DOI":"10.1016\/S0021-9673(02)00104-8","article-title":"Gas chromatography for in situ analysis of a cometary nucleus: III. multi-capillary column system for the cometary sampling and composition experiment of the Rosetta lander probe","volume":"953","author":"Szopa","year":"2002","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2026.467419_bib0009","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1089\/ast.2016.1551","article-title":"The Mars organic molecule analyzer (MOMA) instrument: characterization of organic material in martian sediments","volume":"17","author":"Goesmann","year":"2017","journal-title":"Astrobiology"},{"key":"10.1016\/j.chroma.2026.467419_bib0010","doi-asserted-by":"crossref","first-page":"130","DOI":"10.3847\/PSJ\/abfdcf","article-title":"Science goals and objectives for the Dragonfly Titan rotorcraft relocatable lander","volume":"2","author":"Barnes","year":"2021","journal-title":"Planet. Sci. J."},{"key":"10.1016\/j.chroma.2026.467419_bib0011","doi-asserted-by":"crossref","DOI":"10.1038\/micronano.2017.101","article-title":"Compact prototype microfabricated gas chromatographic analyzer for autonomous determinations of VOC mixtures at typical workplace concentrations","volume":"4","author":"Wang","year":"2018","journal-title":"Microsyst. Nanoeng."},{"key":"10.1016\/j.chroma.2026.467419_bib0012","doi-asserted-by":"crossref","first-page":"32749","DOI":"10.1039\/C7RA03271D","article-title":"MEMS-based column coated with reduced graphene oxide as stationary phase for gas chromatography","volume":"7","author":"Yuan","year":"2017","journal-title":"RSC Adv"},{"key":"10.1016\/j.chroma.2026.467419_bib0013","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.1109\/JMEMS.2006.879708","article-title":"High-speed MEMS-based gas chromatography","volume":"15","author":"Agah","year":"2006","journal-title":"J. Microelectromech. Syst."},{"key":"10.1016\/j.chroma.2026.467419_bib0014","doi-asserted-by":"crossref","DOI":"10.34133\/adi.0049","article-title":"Biosignature detection from amino acid enantiomers with portable gas chromatography systems","volume":"5","author":"Blase","year":"2024","journal-title":"Adv. Devices Instrum."},{"key":"10.1016\/j.chroma.2026.467419_bib0015","doi-asserted-by":"crossref","DOI":"10.3389\/fspas.2022.828103","article-title":"MEMS GC column performance for analyzing organics and biological molecules for future landed planetary missions","volume":"9","author":"Blase","year":"2022","journal-title":"Front. Astron. Space Sci."},{"key":"10.1016\/j.chroma.2026.467419_bib0016","doi-asserted-by":"crossref","first-page":"1718","DOI":"10.1021\/acsearthspacechem.0c00131","article-title":"Experimental coupling of a MEMS gas chromatograph and a mass spectrometer for organic analysis in space environments","volume":"4","author":"Blase","year":"2020","journal-title":"ACS Earth Space Chem"},{"key":"10.1016\/j.chroma.2026.467419_bib0017","doi-asserted-by":"crossref","first-page":"329","DOI":"10.1016\/j.chroma.2015.12.037","article-title":"Conventional and enantioselective gas chromatography with microfabricated planar columns for analysis of real-world samples of plant volatile fraction","volume":"1429","author":"Cagliero","year":"2016","journal-title":"J. Chromatogr. A"},{"key":"10.1016\/j.chroma.2026.467419_bib0018","doi-asserted-by":"crossref","first-page":"6073","DOI":"10.1021\/es204625w","article-title":"Microfabricated gas chromatograph for on-site determinations of TCE in indoor air arising from vapor intrusion. 2. spatial\/temporal monitoring","volume":"46","author":"Kim","year":"2012","journal-title":"Environ. Sci. Technol."},{"key":"10.1016\/j.chroma.2026.467419_bib0019","unstructured":"M. Rizk-Bigourd, D. Coscia, F. Ferreira, P. Cardinael, C. Szopa, A. Buch, V. Agasse-Peulon, A. Boco-Simon, A. Philippart, Syst\u00e8me de chromatographie, French Patent FR3157547A1 (2023)."},{"key":"10.1016\/j.chroma.2026.467419_bib0020","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1021\/acsearthspacechem.4c00111","article-title":"Development and integration of an ultraminiaturized gas chromatograph prototype based on lab-on-a-chip microelectromechanical systems for space exploration missions","volume":"8","author":"Rizk-Bigourd","year":"2024","journal-title":"ACS Earth Space Chem"},{"key":"10.1016\/j.chroma.2026.467419_bib0021","doi-asserted-by":"crossref","DOI":"10.1016\/j.jcoa.2024.100180","article-title":"Microchip gas chromatographic columns dedicated for space exploration: stationary phase coating, setup optimization and evaluation of column performances","volume":"6","author":"Philippart","year":"2024","journal-title":"J. Chromatogr. Open"},{"key":"10.1016\/j.chroma.2026.467419_bib0022","unstructured":"M. Rizk-Bigourd, A. Philippart, P. Cardinael, V. Agasse-Peulon, C. Szopa, F. Ferreira, A. Buch, D. Coscia, A. Boco-Simon, Proc\u00e9d\u00e9 de pr\u00e9paration d\u2019un micro-canal tubulaire pour une chromatographie en phase gazeuse, French Patent FR3157547A1 (2023)."},{"key":"10.1016\/j.chroma.2026.467419_bib0023","doi-asserted-by":"crossref","first-page":"11605","DOI":"10.1021\/acs.analchem.7b03036","article-title":"Chip-based multicapillary column with maximal interconnectivity to combine maximum efficiency and maximum loadability","volume":"89","author":"Jespers","year":"2017","journal-title":"Anal. Chem."},{"key":"10.1016\/j.chroma.2026.467419_bib0024","series-title":"Extraterrestrial Molecular Indicators of Life Investigation (EMILI), 2024 IEEE Aerospace Conference","first-page":"1","author":"Danell","year":"2024"},{"key":"10.1016\/j.chroma.2026.467419_bib0025","doi-asserted-by":"crossref","first-page":"213","DOI":"10.1089\/ast.2022.0038","article-title":"Selection and analytical performances of the dragonfly mass spectrometer gas chromatographic columns to support the search for organic molecules of astrobiological interest on Titan","volume":"23","author":"Moulay","year":"2023","journal-title":"Astrobiology"},{"key":"10.1016\/j.chroma.2026.467419_bib0026","doi-asserted-by":"crossref","first-page":"2629","DOI":"10.1021\/ac030367x","article-title":"Design, fabrication, and evaluation of microfabricated columns for gas chromatography","volume":"76","author":"Lambertus","year":"2004","journal-title":"Anal. Chem."}],"container-title":["Journal of Chromatography A"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021967326007454?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0021967326007454?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,26]],"date-time":"2026-09-26T12:20:35Z","timestamp":1790425235000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0021967326007454"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":26,"alternative-id":["S0021967326007454"],"URL":"https:\/\/doi.org\/10.1016\/j.chroma.2026.467419","relation":{},"ISSN":["0021-9673"],"issn-type":[{"value":"0021-9673","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Lab-on-chip column for space missions\u2019 application: design optimization of fluidic interface and column inlet-outlet to combine test reliability and maximum efficiency","name":"articletitle","label":"Article Title"},{"value":"Journal of Chromatography A","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.chroma.2026.467419","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"467419"}}