{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,19]],"date-time":"2025-11-19T14:42:13Z","timestamp":1763563333547,"version":"3.40.5"},"reference-count":17,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2018,1,1]],"date-time":"2018-01-01T00:00:00Z","timestamp":1514764800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["onlinecjc.ca","clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Canadian Journal of Cardiology"],"published-print":{"date-parts":[[2018,1]]},"DOI":"10.1016\/j.cjca.2017.09.022","type":"journal-article","created":{"date-parts":[[2017,10,11]],"date-time":"2017-10-11T13:16:58Z","timestamp":1507727818000},"page":"61-65","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":16,"title":["Comparability of Automated Office Blood Pressure to Daytime 24-Hour Ambulatory Blood Pressure"],"prefix":"10.1016","volume":"34","author":[{"given":"Jennifer S.","family":"Ringrose","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jonathan","family":"Cena","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Shannon","family":"Ip","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Fraulein","family":"Morales","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Peter","family":"Hamilton","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3541-2817","authenticated-orcid":false,"given":"Raj","family":"Padwal","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.cjca.2017.09.022_bib1","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/j.cjca.2015.02.014","article-title":"A\u00a0new algorithm for the diagnosis of hypertension in Canada","volume":"31","author":"Cloutier","year":"2015","journal-title":"Can J Cardiol"},{"key":"10.1016\/j.cjca.2017.09.022_bib2","doi-asserted-by":"crossref","first-page":"557","DOI":"10.1016\/j.cjca.2017.03.005","article-title":"Hypertension Canada's 2017 guidelines for diagnosis, risk assessment, prevention, and treatment of hypertension in adults","volume":"33","author":"Leung","year":"2017","journal-title":"Can J Cardiol"},{"key":"10.1016\/j.cjca.2017.09.022_bib3","doi-asserted-by":"crossref","first-page":"83","DOI":"10.1111\/jch.12252","article-title":"Eliminating the human factor in office blood pressure measurement","volume":"16","author":"Myers","year":"2014","journal-title":"J\u00a0Clin Hypertens"},{"key":"10.1016\/j.cjca.2017.09.022_bib4","first-page":"e193","article-title":"How do family physicians measure blood pressure in routine clinical practice? National survey of Canadian family physicians","volume":"63","author":"Kaczorowski","year":"2017","journal-title":"Can Fam Physician"},{"key":"10.1016\/j.cjca.2017.09.022_bib5","doi-asserted-by":"crossref","first-page":"963","DOI":"10.1016\/j.cjca.2017.04.001","article-title":"Measuring blood pressure and diagnosing hypertension in the physicians office in the age of automated devices: time for guidelines to reflect reality","volume":"33","author":"Godwin","year":"2017","journal-title":"Can J Cardiol"},{"key":"10.1016\/j.cjca.2017.09.022_bib6","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1161\/HYPERTENSIONAHA.116.08076","article-title":"Effect of intensive versus standard clinic-based hypertension management on ambulatory blood pressure: novelty and significance","volume":"69","author":"Drawz","year":"2017","journal-title":"Hypertension"},{"key":"10.1016\/j.cjca.2017.09.022_bib7","first-page":"37","article-title":"Blood pressure in Canadian adults","volume":"21","author":"Wilkins","year":"2010","journal-title":"Health Rep"},{"key":"10.1016\/j.cjca.2017.09.022_bib8","doi-asserted-by":"crossref","first-page":"644","DOI":"10.1016\/j.cjca.2017.01.020","article-title":"Are automated blood pressure monitors comparable to ambulatory blood pressure monitors? A systematic review and meta-analysis","volume":"33","author":"Jegatheswaran","year":"2017","journal-title":"Can J Cardiol"},{"key":"10.1016\/j.cjca.2017.09.022_bib9","first-page":"1","article-title":"Blood pressure randomized methodology study comparing automatic oscillometric and mercury sphygmomanometer devices: National Health and Nutrition Examination Survey, 2009-2010","volume":"59","author":"Ostchega","year":"2012","journal-title":"Natl Health Stat Report"},{"key":"10.1016\/j.cjca.2017.09.022_bib10","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1007\/s12170-012-0247-z","article-title":"Hypertension prevalence and control: impact of method of blood pressure measurement","volume":"6","author":"Cloutier","year":"2012","journal-title":"Curr Cardiovasc Risk Rep"},{"key":"10.1016\/j.cjca.2017.09.022_bib11","doi-asserted-by":"crossref","first-page":"E689","DOI":"10.1503\/cmaj.130764","article-title":"Assessment and management of resistant hypertension","volume":"186","author":"Padwal","year":"2014","journal-title":"CMAJ"},{"key":"10.1016\/j.cjca.2017.09.022_bib13","doi-asserted-by":"crossref","first-page":"591","DOI":"10.1016\/S0140-6736(14)61212-5","article-title":"Blood pressure-lowering treatment based on cardiovascular risk: a meta-analysis of individual patient data","volume":"384","year":"2014","journal-title":"Lancet"},{"key":"10.1016\/j.cjca.2017.09.022_bib14","doi-asserted-by":"crossref","first-page":"494","DOI":"10.1016\/S0895-7061(03)00058-X","article-title":"Use of an automated blood pressure recording device, the BpTRU, to reduce the \u201cwhite coat effect\u201d in routine practice","volume":"16","author":"Myers","year":"2003","journal-title":"Am J Hypertens"},{"key":"10.1016\/j.cjca.2017.09.022_bib15","doi-asserted-by":"crossref","first-page":"267","DOI":"10.1111\/j.1524-6175.2007.06512.x","article-title":"Automated measurement of blood pressure in routine clinical practice","volume":"9","author":"Myers","year":"2007","journal-title":"J\u00a0Clin Hypertens"},{"key":"10.1016\/j.cjca.2017.09.022_bib16","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.jash.2013.07.002","article-title":"BpTRUth: do automated blood pressure monitors outperform mercury","volume":"7","author":"Edwards","year":"2013","journal-title":"J\u00a0Am Soc Hypertens"},{"key":"10.1016\/j.cjca.2017.09.022_bib17","doi-asserted-by":"crossref","first-page":"110","DOI":"10.1093\/fampra\/cmq067","article-title":"Manual and automated office measurements in relation to awake ambulatory blood pressure monitoring","volume":"28","author":"Godwin","year":"2011","journal-title":"Fam Pract"},{"key":"10.1016\/j.cjca.2017.09.022_bib18","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1097\/MBP.0b013e32831e314f","article-title":"Comparison of two automated sphygmomanometers for use in the office setting","volume":"14","author":"Myers","year":"2009","journal-title":"Blood Press Monit"}],"container-title":["Canadian Journal of Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0828282X17310425?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0828282X17310425?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,8,26]],"date-time":"2018-08-26T23:26:20Z","timestamp":1535325980000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0828282X17310425"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,1]]},"references-count":17,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2018,1]]}},"alternative-id":["S0828282X17310425"],"URL":"https:\/\/doi.org\/10.1016\/j.cjca.2017.09.022","relation":{},"ISSN":["0828-282X"],"issn-type":[{"type":"print","value":"0828-282X"}],"subject":[],"published":{"date-parts":[[2018,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparability of Automated Office Blood Pressure to Daytime 24-Hour Ambulatory Blood Pressure","name":"articletitle","label":"Article Title"},{"value":"Canadian Journal of Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.cjca.2017.09.022","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2017 Canadian Cardiovascular Society. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}