{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,3]],"date-time":"2026-04-03T02:52:26Z","timestamp":1775184746257,"version":"3.50.1"},"reference-count":22,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,9,1]],"date-time":"2025-09-01T00:00:00Z","timestamp":1756684800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2025,5,29]],"date-time":"2025-05-29T00:00:00Z","timestamp":1748476800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["cjcopen.ca","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["CJC Open"],"published-print":{"date-parts":[[2025,9]]},"DOI":"10.1016\/j.cjco.2025.05.015","type":"journal-article","created":{"date-parts":[[2025,6,4]],"date-time":"2025-06-04T19:54:30Z","timestamp":1749066870000},"page":"1149-1156","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"title":["From Wrist to Precision: Enhanced Atrial Flutter Detection with Modified Smartwatch Single-Lead Electrocardiogram Placement"],"prefix":"10.1016","volume":"7","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-8440-8892","authenticated-orcid":false,"given":"Yuval","family":"Avidan","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Amir","family":"Aker","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Razi","family":"Khoury","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sameha","family":"Zahra","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Nissan","family":"Ben Dov","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jorge E.","family":"Schliamser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Asaf","family":"Danon","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.cjco.2025.05.015_bib1","doi-asserted-by":"crossref","first-page":"373","DOI":"10.1093\/eurheartj\/ehaa612","article-title":"2020 ESC guidelines for the diagnosis and management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"42","author":"Hindricks","year":"2021","journal-title":"Eur Heart J"},{"key":"10.1016\/j.cjco.2025.05.015_bib2","doi-asserted-by":"crossref","first-page":"66","DOI":"10.1016\/j.ahj.2018.09.002","article-title":"Rationale and design of a large-scale, app-based study to identify cardiac arrhythmias using a smartwatch: The Apple Heart Study","volume":"207","author":"Turakhia","year":"2019","journal-title":"Am Heart J"},{"key":"10.1016\/j.cjco.2025.05.015_bib3","doi-asserted-by":"crossref","first-page":"55","DOI":"10.15420\/aer.2017:5:2","article-title":"Atrial flutter, typical and atypical: a review","volume":"6","author":"Cos\u00edo","year":"2017","journal-title":"Arrhythm Electrophysiol Rev"},{"key":"10.1016\/j.cjco.2025.05.015_bib4","doi-asserted-by":"crossref","first-page":"2176","DOI":"10.1161\/CIRCULATIONAHA.114.014343","article-title":"Mass screening for untreated atrial fibrillation","volume":"131","author":"Svennberg","year":"2015","journal-title":"Circulation"},{"key":"10.1016\/j.cjco.2025.05.015_bib5","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1016\/j.jelectrocard.2018.07.008","article-title":"Modified positioning of a smartphone based single-lead electrocardiogram device improves detection of atrial flutter","volume":"51","author":"Rajakariar","year":"2018","journal-title":"J Electrocardiol"},{"key":"10.1016\/j.cjco.2025.05.015_bib6","doi-asserted-by":"crossref","first-page":"808","DOI":"10.1016\/j.hrcr.2020.06.021","article-title":"Using a smartwatch to identify the morphology of atrial flutter","volume":"6","author":"Ahmed","year":"2020","journal-title":"HeartRhythm Case Rep"},{"key":"10.1016\/j.cjco.2025.05.015_bib7","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1016\/j.acvd.2021.11.003","article-title":"Beyond the wrist: using a smartwatch electrocardiogram to detect electrocardiographic abnormalities","volume":"115","author":"Ploux","year":"2022","journal-title":"Arch Cardiovasc Dis"},{"key":"10.1016\/j.cjco.2025.05.015_bib8","doi-asserted-by":"crossref","first-page":"3314","DOI":"10.1093\/eurheartj\/ehae176","article-title":"2024 ESC guidelines for the management of atrial fibrillation developed in collaboration with the European Association for Cardio-Thoracic Surgery (EACTS)","volume":"45","author":"Van Gelder","year":"2024","journal-title":"Eur Heart J"},{"key":"10.1016\/j.cjco.2025.05.015_bib9","doi-asserted-by":"crossref","first-page":"2356","DOI":"10.1093\/eurheartj\/ehv118","article-title":"Atrial flutter: more than just one of a kind","volume":"36","author":"Bun","year":"2015","journal-title":"Eur Heart J"},{"key":"10.1016\/j.cjco.2025.05.015_bib10","doi-asserted-by":"crossref","first-page":"60","DOI":"10.1161\/01.CIR.0000079140.35025.1E","article-title":"Surface electrocardiographic characteristics of right and left atrial flutter","volume":"108","author":"Bochoeyer","year":"2003","journal-title":"Circulation"},{"key":"10.1016\/j.cjco.2025.05.015_bib11","first-page":"450","article-title":"Typical atrial flutter with atypical flutter wave morphology due to abnormal interatrial conduction","volume":"18","author":"Irie","year":"2011","journal-title":"Cardiol J"},{"key":"10.1016\/j.cjco.2025.05.015_bib12","doi-asserted-by":"crossref","first-page":"1251","DOI":"10.1111\/j.1540-8159.2011.03137.x","article-title":"Predictors of unusual ECG characteristics in cavotricuspid isthmus-dependent atrial flutter ablation","volume":"34","author":"Hoffmayer","year":"2011","journal-title":"Pacing Clin Electrophysiol"},{"key":"10.1016\/j.cjco.2025.05.015_bib13","doi-asserted-by":"crossref","DOI":"10.1016\/j.jelectrocard.2024.153851","article-title":"In the face of confounders: atrial fibrillation detection\u2014Practitioners vs. ChatGPT","volume":"88","author":"Avidan","year":"2025","journal-title":"J Electrocardiol"},{"key":"10.1016\/j.cjco.2025.05.015_bib14","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1097\/MAJ.0b013e3181e73fcf","article-title":"Accuracy of diagnosing atrial flutter and atrial fibrillation from a surface electrocardiogram by hospital physicians: analysis of data from internal medicine departments","volume":"340","author":"Shiyovich","year":"2010","journal-title":"Am J Med Sci"},{"key":"10.1016\/j.cjco.2025.05.015_bib15","doi-asserted-by":"crossref","first-page":"e289","DOI":"10.1016\/j.amjmed.2016.06.042","article-title":"Why do computer programs misdiagnose flutter?","volume":"129","author":"Bui","year":"2016","journal-title":"Am J Med"},{"key":"10.1016\/j.cjco.2025.05.015_bib16","doi-asserted-by":"crossref","first-page":"1524","DOI":"10.1016\/j.hrthm.2021.06.1176","article-title":"Smartwatch-based detection of cardiac arrhythmias: beyond the differentiation between sinus rhythm and atrial fibrillation","volume":"18","author":"Strik","year":"2021","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.cjco.2025.05.015_bib17","doi-asserted-by":"crossref","first-page":"655","DOI":"10.1093\/eurheartj\/ehz467","article-title":"2019 ESC guidelines for the management of patients with supraventricular tachycardia: The Task Force for the Management of Patients with Supraventricular Tachycardia of the European Society of Cardiology (ESC)","volume":"41","author":"Brugada","year":"2020","journal-title":"Eur Heart J"},{"key":"10.1016\/j.cjco.2025.05.015_bib18","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1093\/europace\/euab050","article-title":"The European telecheck-AF project on remote app-based management of atrial fibrillation during the COVID-19 pandemic: centre and patient experiences","volume":"23","author":"Gawa\u0142ko","year":"2021","journal-title":"EP Europace"},{"key":"10.1016\/j.cjco.2025.05.015_bib19","doi-asserted-by":"crossref","first-page":"1823","DOI":"10.1038\/s41591-022-01979-w","article-title":"Smartphone-based screening for atrial fibrillation: a pragmatic randomized clinical trial","volume":"28","author":"Rizas","year":"2022","journal-title":"Nat Med"},{"key":"10.1016\/j.cjco.2025.05.015_bib20","article-title":"Wearable health monitoring: wave of the future or waste of time?","volume":"2024","author":"Hudock","year":"2024","journal-title":"Glob Cardiol Sci Pract"},{"key":"10.1016\/j.cjco.2025.05.015_bib21","doi-asserted-by":"crossref","first-page":"1690","DOI":"10.1016\/j.amjcard.2019.08.026","article-title":"Predictors and incidence of atrial flutter after catheter ablation of atrial fibrillation","volume":"124","author":"Gucuk Ipek","year":"2019","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.cjco.2025.05.015_bib22","doi-asserted-by":"crossref","first-page":"33","DOI":"10.1016\/j.jacep.2017.07.018","article-title":"Useful electrocardiographic features to help identify the mechanism of atrial tachycardia occurring after persistent atrial fibrillation ablation","volume":"4","author":"Pascale","year":"2018","journal-title":"JACC Clin Electrophysiol"}],"container-title":["CJC Open"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2589790X25003968?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2589790X25003968?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,4,3]],"date-time":"2026-04-03T01:56:16Z","timestamp":1775181376000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2589790X25003968"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,9]]},"references-count":22,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2025,9]]}},"alternative-id":["S2589790X25003968"],"URL":"https:\/\/doi.org\/10.1016\/j.cjco.2025.05.015","relation":{},"ISSN":["2589-790X"],"issn-type":[{"value":"2589-790X","type":"print"}],"subject":[],"published":{"date-parts":[[2025,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"From Wrist to Precision: Enhanced Atrial Flutter Detection with Modified Smartwatch Single-Lead Electrocardiogram Placement","name":"articletitle","label":"Article Title"},{"value":"CJC Open","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.cjco.2025.05.015","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2025 The Authors. Published by Elsevier Inc. on behalf of the Canadian Cardiovascular Society.","name":"copyright","label":"Copyright"}]}}