{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T15:37:44Z","timestamp":1784043464538,"version":"3.55.0"},"reference-count":13,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2021,5,1]],"date-time":"2021-05-01T00:00:00Z","timestamp":1619827200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,5,1]],"date-time":"2021-05-01T00:00:00Z","timestamp":1619827200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,2,26]],"date-time":"2021-02-26T00:00:00Z","timestamp":1614297600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Chinese Journal of Traumatology"],"published-print":{"date-parts":[[2021,5]]},"DOI":"10.1016\/j.cjtee.2021.02.009","type":"journal-article","created":{"date-parts":[[2021,2,26]],"date-time":"2021-02-26T12:51:45Z","timestamp":1614343905000},"page":"169-173","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":8,"title":["Comparison of the clinical efficacy of different fixation systems for the treatment of transverse patellar fractures"],"prefix":"10.1016","volume":"24","author":[{"given":"Zhi-Biao","family":"Bai","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shi-Chang","family":"Gao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Hai-Bo","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chao","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Chun","family":"Chen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.cjtee.2021.02.009_bib1","doi-asserted-by":"crossref","first-page":"1477","DOI":"10.1302\/0301-620X.100B11.BJJ-2018-0312.R2","article-title":"Patellar fractures are associated with an increased risk of total knee arthroplasty","volume":"100","author":"Larsen","year":"2018","journal-title":"Bone Joint Lett J"},{"key":"10.1016\/j.cjtee.2021.02.009_bib2","doi-asserted-by":"crossref","first-page":"20165","DOI":"10.4414\/smw.2020.20165","article-title":"Practical guidelines for the treatment of patellar fractures in adults","volume":"150","author":"Steinmetz","year":"2020","journal-title":"Swiss Med Wkly"},{"key":"10.1016\/j.cjtee.2021.02.009_bib3","first-page":"205","article-title":"Analysis of complications and causes of failure in the treatment of patellar fracture with Kirschner wire tension band internal fixation","volume":"20","author":"Liu","year":"2005","journal-title":"Chin J Bone Joint Injury"},{"key":"10.1016\/j.cjtee.2021.02.009_bib4","doi-asserted-by":"crossref","first-page":"653","DOI":"10.2106\/JBJS.K.01549","article-title":"Complications following tension-band fixation of patellar fractures with cannulated screws compared with Kirschner wires","volume":"95","author":"Hoshino","year":"2013","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.cjtee.2021.02.009_bib5","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1186\/s13018-019-1060-x","article-title":"Where should Kirschner wires be placed when fixing patella fracture with modified tension-band wiring? A finite element analysis","volume":"14","author":"Ling","year":"2019","journal-title":"J\u00a0Orthop Surg Res"},{"key":"10.1016\/j.cjtee.2021.02.009_bib6","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1186\/s12891-020-03536-3","article-title":"Clinical outcomes of Ti-Ni shape-memory patella concentrator combined with cannulated compression screws in the treatment of C2 and C3 patella fracture: a retrospective study of 54 cases","volume":"21","author":"Yao","year":"2020","journal-title":"BMC Muscoskel Disord"},{"key":"10.1016\/j.cjtee.2021.02.009_bib7","first-page":"967","article-title":"Effect and clinical advantage of hollow nail combined with tension band in the treatment of patellar fracture","volume":"25","author":"Gao","year":"2020","journal-title":"ZH J J Traumatic"},{"key":"10.1016\/j.cjtee.2021.02.009_bib8","first-page":"59","article-title":"Comparison of the effect of hollow tension screw and Kirschner wire combined with \"8\" tension band wire in the treatment of transverse patellar fracture","volume":"23","author":"Huang","year":"2017","journal-title":"Henan J Surg"},{"key":"10.1016\/j.cjtee.2021.02.009_bib9","first-page":"571","article-title":"Comparison of internal fixation of hollow nail combined with tension band wire and Kirschner wire combined with tension band wire in the treatment of patellar fracture","volume":"28","author":"Wei","year":"2013","journal-title":"Chin J Bone Joint Injury"},{"key":"10.1016\/j.cjtee.2021.02.009_bib10","series-title":"Vol","first-page":"33","article-title":"A\u00a0retrospective comparison of three different internal fixation methods in transverse patella fracture","author":"Huang","year":"2015"},{"key":"10.1016\/j.cjtee.2021.02.009_bib11","first-page":"5622","article-title":"QWIX screw fixation in repair of patellar fractures:continuous dynamic and static pressure in the broken ends of the bones","volume":"18","author":"Liu","year":"2014","journal-title":"Chin J Clin Rehabil Tissue Eng Res"},{"key":"10.1016\/j.cjtee.2021.02.009_bib12","first-page":"335","article-title":"Biomechanical study on internal fixations with a single cannulated one-threaded or double-threaded screw for the treatment of Type II odontoid fractures","volume":"3","author":"Han","year":"2007","journal-title":"Chin J Clin Anat"},{"key":"10.1016\/j.cjtee.2021.02.009_bib13","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1016\/j.medengphy.2019.09.008","article-title":"Comparison of pullout strength of pedicle screws following revision using larger diameter screws","volume":"74","author":"Varghese","year":"2019","journal-title":"Med Eng Phys"}],"container-title":["Chinese Journal of Traumatology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1008127521000328?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1008127521000328?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,19]],"date-time":"2025-10-19T14:15:45Z","timestamp":1760883345000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1008127521000328"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,5]]},"references-count":13,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2021,5]]}},"alternative-id":["S1008127521000328"],"URL":"https:\/\/doi.org\/10.1016\/j.cjtee.2021.02.009","relation":{},"ISSN":["1008-1275"],"issn-type":[{"value":"1008-1275","type":"print"}],"subject":[],"published":{"date-parts":[[2021,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of the clinical efficacy of different fixation systems for the treatment of transverse patellar fractures","name":"articletitle","label":"Article Title"},{"value":"Chinese Journal of Traumatology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.cjtee.2021.02.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 Chinese Medical Association. Production and hosting by Elsevier B.V.","name":"copyright","label":"Copyright"}]}}