{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,9,17]],"date-time":"2025-09-17T15:24:59Z","timestamp":1758122699937},"reference-count":37,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2005,9,1]],"date-time":"2005-09-01T00:00:00Z","timestamp":1125532800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Contact Lens and Anterior Eye"],"published-print":{"date-parts":[[2005,9]]},"DOI":"10.1016\/j.clae.2005.06.001","type":"journal-article","created":{"date-parts":[[2005,7,6]],"date-time":"2005-07-06T22:12:11Z","timestamp":1120687931000},"page":"127-134","source":"Crossref","is-referenced-by-count":2,"title":["Changes in water content of high plus hydrogel lenses worn on an extended wear basis in a geriatric aphakic population"],"prefix":"10.1016","volume":"28","author":[{"given":"Sudi","family":"Patel","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Waheeda","family":"Illahi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Arthur","family":"Davies","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.clae.2005.06.001_bib1","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1111\/j.1475-1313.1988.tb01055.x","article-title":"Dehydration of hydrogel contact lenses in vitro and in vivo","volume":"8","author":"Efron","year":"1988","journal-title":"Ophthal Physiol Opt"},{"key":"10.1016\/j.clae.2005.06.001_bib2","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/S0002-9394(14)77949-8","article-title":"The effects of hypotonic and hypertonic solutions on the fluid content of hydrophilic contact lenses","volume":"99","author":"Aiello","year":"1985","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.clae.2005.06.001_bib3","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1111\/j.1475-1313.1981.tb00388.x","article-title":"Age dependence of human refractive errors","volume":"1","author":"Saunders","year":"1981","journal-title":"Ophthal Physiol Opt"},{"key":"10.1016\/j.clae.2005.06.001_bib4","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1001\/archopht.1950.00910010231004","article-title":"Influence of age and sex on flow of tears","volume":"43","author":"Henderson","year":"1950","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.clae.2005.06.001_bib5","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1097\/00006324-198903000-00008","article-title":"Age related changes in precorneal tear film stability","volume":"66","author":"Patel","year":"1989","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.clae.2005.06.001_bib6","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1136\/bjo.68.5.316","article-title":"Normal tear protein profiles and age-related changes","volume":"68","author":"McGill","year":"1984","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.clae.2005.06.001_bib7","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1016\/0014-4835(76)90228-1","article-title":"The glycoprotein (mucus) content of tears from normal and dry eye patients","volume":"22","author":"Dohlman","year":"1976","journal-title":"Exp Eye Res"},{"key":"10.1016\/j.clae.2005.06.001_bib8","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/0275-5408(95)00071-K","article-title":"Tear lipid layer structure and stability following expression of the meibomian glands","volume":"15","author":"Craig","year":"1995","journal-title":"Ophthal Physiol Opt"},{"key":"10.1016\/j.clae.2005.06.001_bib9","doi-asserted-by":"crossref","first-page":"8","DOI":"10.1097\/00006324-199701000-00014","article-title":"Importance of the lipid layer in human tear stability and evaporation","volume":"74","author":"Craig","year":"1997","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.clae.2005.06.001_bib10","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1097\/00006324-198303000-00004","article-title":"A comparative study of tear evaporation rates and water content of soft contact lenses","volume":"60","author":"Cedarstaff","year":"1983","journal-title":"Am J Optom Physiol Opt"},{"key":"10.1016\/j.clae.2005.06.001_bib11","doi-asserted-by":"crossref","first-page":"1092","DOI":"10.3109\/02713689608995140","article-title":"The effects of eye closure on the protein and complement deposition on group IV hydrogel contact lenses: relationship to tear flow dynamics","volume":"15","author":"Sack","year":"1996","journal-title":"Curr Eye Res"},{"key":"10.1016\/j.clae.2005.06.001_bib12","first-page":"735","article-title":"Uneven swelling of the corneal stroma","volume":"9","author":"Kikkawa","year":"1970","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2005.06.001_bib13","doi-asserted-by":"crossref","first-page":"253","DOI":"10.1159\/000264570","article-title":"Glucose concentration and hydration of the corneal stroma","volume":"2","author":"Turss","year":"1971","journal-title":"Ophthal Res"},{"key":"10.1016\/j.clae.2005.06.001_bib14","doi-asserted-by":"crossref","first-page":"457","DOI":"10.3109\/02713688109019986","article-title":"Non-uniform swelling properties of the corneal stroma","volume":"1","author":"Lee","year":"1981","journal-title":"Curr Eye Res"},{"key":"10.1016\/j.clae.2005.06.001_bib15","doi-asserted-by":"crossref","first-page":"224","DOI":"10.3928\/1081-597X-19920501-09","article-title":"A comparison of corneal stromal edema induced from the anterior or the posterior surface","volume":"8","author":"Cristol","year":"1992","journal-title":"Refract Corneal Surg"},{"key":"10.1016\/j.clae.2005.06.001_bib16","first-page":"31","article-title":"The effects of the hydration characteristics of hydrogel lenses on the refractive index","volume":"10","author":"Moussa","year":"1983","journal-title":"Int Contact lens Clin"},{"key":"10.1016\/j.clae.2005.06.001_bib17","first-page":"357","article-title":"A simple instrument for measuring the water content of hydrogel lenses","volume":"10","author":"Brennan","year":"1983","journal-title":"Int Contact lens Clin"},{"key":"10.1016\/j.clae.2005.06.001_bib18","first-page":"625","article-title":"Refractive index calculation of hydrogel lenses","volume":"11","author":"Teurle","year":"1984","journal-title":"Int Contact lens Clin"},{"key":"10.1016\/j.clae.2005.06.001_bib19","doi-asserted-by":"crossref","first-page":"277","DOI":"10.1097\/00006324-198804000-00006","article-title":"Dehydration of hydrogel lenses: environmental influences during normal wear","volume":"65","author":"Brennan","year":"1988","journal-title":"Am J Optom Physiol Opt"},{"key":"10.1016\/j.clae.2005.06.001_bib20","first-page":"152","article-title":"Dehydration of hydrogel lenses under normal wearing conditions","volume":"13","author":"Efron","year":"1987","journal-title":"CLAO J"},{"key":"10.1016\/j.clae.2005.06.001_bib21","first-page":"49","article-title":"Comparative study of some physiologically important properties of six brands of disposable hydrogel contact lenses","volume":"23","author":"Fatt","year":"1997","journal-title":"CLAO J"},{"key":"10.1016\/j.clae.2005.06.001_bib22","doi-asserted-by":"crossref","first-page":"317","DOI":"10.1098\/rstl.1863.0014","article-title":"Researchs in the refraction dispersion and sensitiviness of liquids","volume":"153","author":"Gladstone","year":"1863","journal-title":"Philos Trans Royal Soc (Lond)"},{"key":"10.1016\/j.clae.2005.06.001_bib23","first-page":"250","article-title":"The effect of temperature on the refractive index, water content and central thickness of hydrogel contact lenses","volume":"7","author":"Fatt","year":"1980","journal-title":"Int Contact lens Clin"},{"key":"10.1016\/j.clae.2005.06.001_bib24","first-page":"117","article-title":"Limitations of in vitro contact lens dehydration\/rehydration data in predicting on-eye dehydration","volume":"23","author":"McConville","year":"1997","journal-title":"CLAO J"},{"key":"10.1016\/j.clae.2005.06.001_bib25","first-page":"22","article-title":"Hydrogel dehydration in various environments","volume":"10","author":"Andrasko","year":"1983","journal-title":"Int Contact lens Clin"},{"key":"10.1016\/j.clae.2005.06.001_bib26","first-page":"210","article-title":"The effect of humidity on dehydration of soft contact lenses on the eye","volume":"7","author":"Andrasko","year":"1980","journal-title":"Int Contact lens Clin"},{"key":"10.1016\/j.clae.2005.06.001_bib27","first-page":"154","article-title":"In vivo hydration of gel lenses","volume":"9","author":"Wechsler","year":"1982","journal-title":"Int Contact lens Clin"},{"key":"10.1016\/j.clae.2005.06.001_bib28","first-page":"349","article-title":"In vivo hydration of hydrogel lenses- the first hour","volume":"10","author":"Wechsler","year":"1983","journal-title":"Int Contact lens Clin"},{"key":"10.1016\/j.clae.2005.06.001_bib29","first-page":"85","article-title":"Hydrogel contact lens ageing","volume":"2","author":"Morgan","year":"2000","journal-title":"CLAO J"},{"key":"10.1016\/j.clae.2005.06.001_bib30","first-page":"40","article-title":"Omafilcon A (Proclear) soft contact lenses in a dry eye population","volume":"25","author":"Lemp","year":"1999","journal-title":"CLAO J"},{"key":"10.1016\/j.clae.2005.06.001_bib31","doi-asserted-by":"crossref","first-page":"281","DOI":"10.1016\/0275-5408(95)00004-W","article-title":"Dehydration, lens movement and dryness ratings of hydrogel contact lenses","volume":"15","author":"Pritchard","year":"1995","journal-title":"Ophthalmic Physiol Opt"},{"key":"10.1016\/j.clae.2005.06.001_bib32","doi-asserted-by":"crossref","first-page":"700","DOI":"10.1097\/00006324-199910000-00021","article-title":"Hydrogel lens dehydration and subjective comfort and dryness ratings in symptomatic and asymptomatic contact lens wearers","volume":"76","author":"Fonn","year":"1999","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.clae.2005.06.001_bib33","doi-asserted-by":"crossref","first-page":"201","DOI":"10.1097\/00006324-199003000-00010","article-title":"In vivo dehydration of disposable (Acuvue) contact lenses","volume":"67","author":"Brennan","year":"1990","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.clae.2005.06.001_bib34","first-page":"148","article-title":"Hydrogel contact lens dehydration and oxygen transmissibility","volume":"25","author":"Efron","year":"1999","journal-title":"CLAO J"},{"key":"10.1016\/j.clae.2005.06.001_bib35","first-page":"501","article-title":"Tear analysis in contact lens wearers","volume":"88","author":"Farris","year":"1985","journal-title":"Trans Am Ophthalmol Soc"},{"key":"10.1016\/j.clae.2005.06.001_bib36","first-page":"374","article-title":"The effect of collection technique on tear composition","volume":"25","author":"Stuchell","year":"1984","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2005.06.001_bib37","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1111\/j.1475-1313.1989.tb00848.x","article-title":"Apparent changes in the refractive index of hydrogel lenses","volume":"9","author":"Patel","year":"1989","journal-title":"Ophthalmic Physiol Opt"}],"container-title":["Contact Lens and Anterior Eye"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048405000457?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048405000457?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2021,7,13]],"date-time":"2021-07-13T02:54:05Z","timestamp":1626144845000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1367048405000457"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,9]]},"references-count":37,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2005,9]]}},"alternative-id":["S1367048405000457"],"URL":"https:\/\/doi.org\/10.1016\/j.clae.2005.06.001","relation":{},"ISSN":["1367-0484"],"issn-type":[{"value":"1367-0484","type":"print"}],"subject":[],"published":{"date-parts":[[2005,9]]}}}