{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,5]],"date-time":"2026-05-05T05:42:38Z","timestamp":1777959758830,"version":"3.51.4"},"reference-count":24,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2016,4,1]],"date-time":"2016-04-01T00:00:00Z","timestamp":1459468800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","contactlensjournal.com","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Contact Lens and Anterior Eye"],"published-print":{"date-parts":[[2016,4]]},"DOI":"10.1016\/j.clae.2015.09.007","type":"journal-article","created":{"date-parts":[[2015,10,24]],"date-time":"2015-10-24T15:03:38Z","timestamp":1445699018000},"page":"148-153","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"title":["The use of ocular anatomical measurements using a rotating Scheimpflug camera to assist in the Esclera\u00ae scleral contact lens fitting process"],"prefix":"10.1016","volume":"39","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-8339-4321","authenticated-orcid":false,"given":"Sarah","family":"La Porta Weber","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"suffix":"Jr.","given":"Renato","family":"Ambr\u00f3sio","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C\u00e9sar","family":"Lipener","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cleusa","family":"Coral-Ghanem","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Ana Luisa","family":"Hofling-Lima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.clae.2015.09.007_bib0005","doi-asserted-by":"crossref","first-page":"507","DOI":"10.1016\/0002-9394(52)91317-2","article-title":"Leonardo da Vinci: of the eye; an original new translation fro Codmex D","volume":"35","author":"Ferrero","year":"1952","journal-title":"Am. J. Ophthalmol."},{"key":"10.1016\/j.clae.2015.09.007_bib0010","first-page":"1373","article-title":"A contact-lens. 1888 (translation)","volume":"106","author":"Fick","year":"1988","journal-title":"Arch. Ophthalmol."},{"key":"10.1016\/j.clae.2015.09.007_bib0015","doi-asserted-by":"crossref","first-page":"21","DOI":"10.1097\/01.icl.0000228964.74647.25","article-title":"Modern scleral lenses part II: patient satisfaction","volume":"33","author":"Visser","year":"2007","journal-title":"Eye Contact Lens"},{"key":"10.1016\/j.clae.2015.09.007_bib0020","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/01.ICL.0000152492.98553.8D","article-title":"Fluid-ventilated, gas-permeable scleral contact lens is an effective option for managing severe ocular surface disease and many corneal disorders that would otherwise require penetrating keratoplasty","volume":"31","author":"Rosenthal","year":"2005","journal-title":"Eye Contact Lens"},{"key":"10.1016\/j.clae.2015.09.007_bib0025","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1097\/01.ico.0000148311.94180.6b","article-title":"Scleral contact lenses: the expanding role","volume":"24","author":"Pullum","year":"2005","journal-title":"Cornea"},{"key":"10.1016\/j.clae.2015.09.007_bib0030","first-page":"160","article-title":"Gas permeable haptic lenses","volume":"6","author":"Ezekiel","year":"1983","journal-title":"Contact Lens Anterior Eye"},{"key":"10.1016\/j.clae.2015.09.007_bib0035","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1097\/ICO.0b013e318155743d","article-title":"Boston scleral lens prosthetic device for treatment of severe dry eye in chronic graft-versus-host disease","volume":"26","author":"Jacobs","year":"2007","journal-title":"Cornea"},{"key":"10.1016\/j.clae.2015.09.007_bib0040","doi-asserted-by":"crossref","first-page":"1729","DOI":"10.1016\/j.jcrs.2005.03.058","article-title":"Central corneal thickness measurement with the Pentacam Scheimpflug system, optical low-coherence reflectometry pachymeter, and ultrasound pachymetry","volume":"31","author":"Barkana","year":"2005","journal-title":"J. Cataract. Refract. Surg."},{"key":"10.1016\/j.clae.2015.09.007_bib0045","doi-asserted-by":"crossref","first-page":"858","DOI":"10.1097\/01.opx.0000177804.53192.15","article-title":"Validity and repeatability of anterior chamber depth measurements with Pentacam and Orbscan","volume":"82","author":"Lackner","year":"2005","journal-title":"Optom. Vis. Sci."},{"key":"10.1016\/j.clae.2015.09.007_bib0050","doi-asserted-by":"crossref","first-page":"1817","DOI":"10.1016\/j.jcrs.2011.04.030","article-title":"International values of corneal elevation in normal subjects by rotating Scheimpflug camera","volume":"37","author":"Feng","year":"2011","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.clae.2015.09.007_bib0055","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1016\/j.ajo.2007.07.021","article-title":"Reproducibility and repeatability of central corneal thickness measurement in keratoconus using the rotating Scheimpflug camera and ultrasound pachymetry","volume":"144","author":"de Sanctis","year":"2007","journal-title":"Am. J. Ophthalmol."},{"key":"10.1016\/j.clae.2015.09.007_bib0060","doi-asserted-by":"crossref","first-page":"448","DOI":"10.1016\/j.jcrs.2006.11.008","article-title":"Intrasession and intersession repeatability of the Pentacam system on posterior corneal assessment in the normal human eye","volume":"33","author":"Chen","year":"2007","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.clae.2015.09.007_bib0065","doi-asserted-by":"crossref","first-page":"970","DOI":"10.1016\/j.jcrs.2006.02.037","article-title":"Corneal thickness measurements in normal and keratoconic eyes: Pentacam comprehensive eye scanner versus noncontact specular microscopy and ultrasound pachymetry","volume":"32","author":"U\u00e7akhan","year":"2006","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.clae.2015.09.007_bib0070","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/j.ajo.2007.08.026","article-title":"Comparison of corneal thickness measurements by ultrasound and Scheimpflug photography in eyes that have undergone laser in situ keratomileusis","volume":"145","author":"Ciolino","year":"2008","journal-title":"Am. J. Ophthalmol."},{"key":"10.1016\/j.clae.2015.09.007_bib0075","doi-asserted-by":"crossref","first-page":"2119","DOI":"10.1016\/j.jcrs.2008.08.030","article-title":"Estimation of the effective lens position using a rotating Scheimpflug camera","volume":"34","author":"Ho","year":"2008","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.clae.2015.09.007_bib0080","doi-asserted-by":"crossref","first-page":"1708","DOI":"10.1016\/j.jcrs.2007.06.020","article-title":"Evaluation of anterior segment parameters in keratoconic eyes measured with the Pentacam system","volume":"33","author":"Emre","year":"2007","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.clae.2015.09.007_bib0085","doi-asserted-by":"crossref","first-page":"456","DOI":"10.1016\/j.jcrs.2005.12.103","article-title":"Anterior chamber measurements using Pentacam rotating Scheimpflug camera","volume":"32","author":"Rabsilber","year":"2006","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.clae.2015.09.007_bib0090","doi-asserted-by":"crossref","first-page":"1101","DOI":"10.1016\/j.jcrs.2009.12.046","article-title":"Anterior chamber characteristics of keratoconus assessed by rotating Scheimpflug imaging","volume":"36","author":"Kov\u00e1cs","year":"2010","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.clae.2015.09.007_bib0095","series-title":"The myopias: basic science and clinical management","first-page":"277","article-title":"Ocular findings and complications","author":"Curtin","year":"1985"},{"key":"10.1016\/j.clae.2015.09.007_bib0100","doi-asserted-by":"crossref","first-page":"916","DOI":"10.1136\/bjo.85.8.916","article-title":"The cornea in young myopic adults","volume":"85","author":"Chang","year":"2001","journal-title":"Br. J. Ophthalmol."},{"key":"10.1016\/j.clae.2015.09.007_bib0105","doi-asserted-by":"crossref","first-page":"489","DOI":"10.1097\/00006324-199707000-00015","article-title":"Ocular components measured by keratometry, phakometry, and ultrasonography in emmetropic and myopic optometry students","volume":"74","author":"Goss","year":"1997","journal-title":"Optom. Vis. Sci."},{"key":"10.1016\/j.clae.2015.09.007_bib0110","first-page":"1507","article-title":"Correlates of lens thickness: the Beaver Dam eye study","volume":"39","author":"Klein","year":"1998","journal-title":"Invest. Ophthalmol. Vis. Sci."},{"key":"10.1016\/j.clae.2015.09.007_bib0115","doi-asserted-by":"crossref","first-page":"651","DOI":"10.1016\/S0161-6420(91)32238-3","article-title":"Long-term outcome after corneal transplantation. Visual result and patient perception of success","volume":"98","author":"Williams","year":"1991","journal-title":"Ophthalmology"},{"key":"10.1016\/j.clae.2015.09.007_bib0120","doi-asserted-by":"crossref","first-page":"1851","DOI":"10.1016\/j.jcrs.2006.06.025","article-title":"Corneal-thickness spatial profile and corneal-volume distribution: tomographic indices to detect keratoconus","volume":"32","author":"Ambr\u00f3sio","year":"2006","journal-title":"J. Cataract Refract. Surg."}],"container-title":["Contact Lens and Anterior Eye"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048415300291?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048415300291?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,18]],"date-time":"2018-09-18T07:20:41Z","timestamp":1537255241000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1367048415300291"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,4]]},"references-count":24,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2016,4]]}},"alternative-id":["S1367048415300291"],"URL":"https:\/\/doi.org\/10.1016\/j.clae.2015.09.007","relation":{},"ISSN":["1367-0484"],"issn-type":[{"value":"1367-0484","type":"print"}],"subject":[],"published":{"date-parts":[[2016,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The use of ocular anatomical measurements using a rotating Scheimpflug camera to assist in the Esclera\u00ae scleral contact lens fitting process","name":"articletitle","label":"Article Title"},{"value":"Contact Lens and Anterior Eye","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clae.2015.09.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}