{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,24]],"date-time":"2026-10-24T22:19:11Z","timestamp":1792880351876,"version":"4.5.0"},"reference-count":55,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,2,1]],"date-time":"2022-02-01T00:00:00Z","timestamp":1643673600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2021,4,1]],"date-time":"2021-04-01T00:00:00Z","timestamp":1617235200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","contactlensjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Contact Lens and Anterior Eye"],"published-print":{"date-parts":[[2022,2]]},"DOI":"10.1016\/j.clae.2021.101443","type":"journal-article","created":{"date-parts":[[2021,4,9]],"date-time":"2021-04-09T08:16:18Z","timestamp":1617956178000},"page":"101443","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Central-to-peripheral corneal edema during wear of embedded-component contact lenses"],"prefix":"10.1016","volume":"45","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-0991-3346","authenticated-orcid":false,"given":"Young Hyun","family":"Kim","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Meng C.","family":"Lin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Clayton J.","family":"Radke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"7","key":"10.1016\/j.clae.2021.101443_bib0005","doi-asserted-by":"crossref","first-page":"3290","DOI":"10.1016\/j.bios.2010.12.042","article-title":"A contact lens with embedded sensor for monitoring tear glucose level","volume":"26","author":"Yao","year":"2011","journal-title":"Biosens Bioelectron"},{"issue":"3","key":"10.1016\/j.clae.2021.101443_bib0010","first-page":"56","article-title":"An accommodative contact lens for presbyopic correction","volume":"6","author":"Jiang","year":"2015","journal-title":"J Clin Exp Ophthalmol"},{"key":"10.1016\/j.clae.2021.101443_bib0015","doi-asserted-by":"crossref","DOI":"10.1126\/sciadv.aap9841","article-title":"Soft, smart contact lenses with integrations of wireless circuits, glucose censors, and displays","volume":"4","author":"Park","year":"2018","journal-title":"Sci Adv"},{"key":"10.1016\/j.clae.2021.101443_bib0020","doi-asserted-by":"crossref","DOI":"10.1002\/adma.201906762","article-title":"Scleral lens sensor for ocular electrolyte analysis","volume":"32","author":"Yetisen","year":"2020","journal-title":"Adv Mater"},{"key":"10.1016\/j.clae.2021.101443_bib0025","series-title":"Proc. SPIE 11302, Light-Emitting Devices, Materials, and Applications XXIV","first-page":"1","article-title":"Mojo vision NanoLEDs for invisible computing","author":"Martin","year":"2020"},{"issue":"1","key":"10.1016\/j.clae.2021.101443_bib0030","doi-asserted-by":"crossref","first-page":"14641","DOI":"10.1038\/s41598-020-71376-1","article-title":"Artificial iris performance for smart contact lens vision correction applications","volume":"10","author":"V\u00e1squez Quintero","year":"2020","journal-title":"Sci Rep"},{"issue":"6","key":"10.1016\/j.clae.2021.101443_bib0035","doi-asserted-by":"crossref","first-page":"792","DOI":"10.1002\/adhm.201400504","article-title":"Contact lens sensors in ocular diagnostics","volume":"4","author":"Farandos","year":"2015","journal-title":"Adv Healthcare Mater"},{"issue":"8","key":"10.1016\/j.clae.2021.101443_bib0040","doi-asserted-by":"crossref","first-page":"9911","DOI":"10.1364\/OE.23.009911","article-title":"Novel switching mode in a vertically aligned liquid crystal contact lens","volume":"23","author":"Syed","year":"2015","journal-title":"Opt Express"},{"issue":"9","key":"10.1016\/j.clae.2021.101443_bib0045","doi-asserted-by":"crossref","first-page":"856","DOI":"10.1038\/nbt0914-856","article-title":"Novartis signs up for Google smart lens","volume":"32","author":"Senior","year":"2014","journal-title":"Nat Biotechnol"},{"issue":"S1","key":"10.1016\/j.clae.2021.101443_bib0050","first-page":"61","article-title":"A spherically shaped display for use as an artificial iris","volume":"44","author":"de Smet","year":"2013","journal-title":"Euro Display"},{"key":"10.1016\/j.clae.2021.101443_bib0055","doi-asserted-by":"crossref","first-page":"929","DOI":"10.1038\/nmat2010","article-title":"Liquid-crystal materials find a new order in biomedical applications","volume":"6","author":"Woltman","year":"2007","journal-title":"Nat Mater"},{"issue":"5","key":"10.1016\/j.clae.2021.101443_bib0060","doi-asserted-by":"crossref","first-page":"627","DOI":"10.1136\/bjo.2010.192922","article-title":"Continuous intraocular pressure monitoring with a wireless ocular telemetry sensor: initial clinical experience in patients with open angle glaucoma","volume":"95","author":"Mansouri","year":"2011","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.clae.2021.101443_bib0065","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1111\/j.1755-3768.2008.01404.x","article-title":"Wireless contact lens sensor for intraocular pressure monitoring: assessment on enucleated pig eyes","volume":"87","author":"Leonardi","year":"2009","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.clae.2021.101443_bib0070","series-title":"2008 IEEE 21st International Conference on Micro Electro Mechanical Systems","first-page":"403","article-title":"Contact lens with integrated inorganic semiconductor devices","author":"Ho","year":"2008"},{"issue":"6","key":"10.1016\/j.clae.2021.101443_bib0075","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1016\/j.preteyeres.2011.07.001","article-title":"Oxygen-deficient metabolism and corneal edema","volume":"30","author":"Leung","year":"2011","journal-title":"Prog Retin Eye Res"},{"key":"10.1016\/j.clae.2021.101443_bib0080","doi-asserted-by":"crossref","first-page":"760","DOI":"10.1001\/archopht.1984.01040030608032","article-title":"Comparative physiologic performance of polymethyl methacrylate and gas-permeable contact lenses","volume":"102","author":"Fonn","year":"1984","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.clae.2021.101443_bib0085","first-page":"553","article-title":"Etiology of corneal striae accompanying hydrogel lens wear","volume":"15","author":"Polse","year":"1976","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2021.101443_bib0090","doi-asserted-by":"crossref","first-page":"263","DOI":"10.1113\/jphysiol.1957.sp005758","article-title":"The structure and transparency of the cornea","volume":"136","author":"Maurice","year":"1957","journal-title":"J Physiol"},{"issue":"3","key":"10.1016\/j.clae.2021.101443_bib0095","doi-asserted-by":"crossref","first-page":"184","DOI":"10.1097\/00006324-199603000-00010","article-title":"Recovery from induced corneal edema and endothelial morphology after long-term PMMA contact lens wear","volume":"73","author":"McMahon","year":"1996","journal-title":"Optom Vis Sci"},{"issue":"10","key":"10.1016\/j.clae.2021.101443_bib0100","first-page":"1161","article-title":"Critical oxygen levels to avoid corneal edema for daily and extended wear contact lenses","volume":"25","author":"Holden","year":"1984","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"4","key":"10.1016\/j.clae.2021.101443_bib0105","doi-asserted-by":"crossref","first-page":"366","DOI":"10.1016\/j.clae.2019.04.002","article-title":"Effects of scleral-lens oxygen transmissibility on corneal thickness: a pilot study","volume":"42","author":"Tan","year":"2019","journal-title":"Cont Lens Anterior Eye"},{"issue":"11","key":"10.1016\/j.clae.2021.101443_bib0110","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1080\/02713683.2018.1500610","article-title":"Central corneal edema with scleral-lens wear","volume":"43","author":"Kim","year":"2018","journal-title":"Curr Eye Res"},{"issue":"3","key":"10.1016\/j.clae.2021.101443_bib0115","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1097\/OPX.0000000000000803","article-title":"Hypoxic corneal changes following eight hours of scleral contact lens wear","volume":"93","author":"Vincent","year":"2016","journal-title":"Optom Vis Sci"},{"issue":"10","key":"10.1016\/j.clae.2021.101443_bib0120","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1097\/00006324-199910000-00023","article-title":"Re-evaluation of the oxygen diffusion model for predicting minimum contact lens Dk\/t values needed to avoid corneal anoxia","volume":"76","author":"Harvitt","year":"1999","journal-title":"Optom Vis Sci"},{"issue":"10","key":"10.1016\/j.clae.2021.101443_bib0125","doi-asserted-by":"crossref","first-page":"6421","DOI":"10.1167\/iovs.14-14038","article-title":"Oxygen diffusion and edema with modern scleral rigid gas permeable contact lenses","volume":"55","author":"Compa\u00f1","year":"2014","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"3","key":"10.1016\/j.clae.2021.101443_bib0130","doi-asserted-by":"crossref","first-page":"1070","DOI":"10.1167\/iovs.02-0343","article-title":"Topographical thickness of the epithelium and total cornea after hydrogel and PMMA contact lens wear with eye closure","volume":"44","author":"Wang","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2021.101443_bib0135","doi-asserted-by":"crossref","first-page":"449","DOI":"10.1111\/j.1755-3768.2010.01947.x","article-title":"Measurement of central corneal thickness by high-resolution Scheimpflug imaging, Fourier-domain optical coherence tomography and ultrasound pachymetry","volume":"90","author":"Chen","year":"2012","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.clae.2021.101443_bib0140","doi-asserted-by":"crossref","first-page":"468","DOI":"10.1016\/S0002-9394(14)75798-8","article-title":"Interferometric measurement of corneal thickness with micrometer precision","volume":"118","author":"Hitzenberger","year":"1994","journal-title":"Am J Ophthalmol"},{"issue":"4","key":"10.1016\/j.clae.2021.101443_bib0145","doi-asserted-by":"crossref","first-page":"405","DOI":"10.1097\/ICO.0b013e31823f0930","article-title":"A quasi-2-dimensional model for respiration of the cornea with soft contact lens wear","volume":"31","author":"Takatori","year":"2012","journal-title":"Cornea"},{"issue":"6","key":"10.1016\/j.clae.2021.101443_bib0150","doi-asserted-by":"crossref","first-page":"654","DOI":"10.1097\/ICO.0b013e31804f5a22","article-title":"Corneal oxygen distribution with contact lens wear","volume":"26","author":"Alvord","year":"2007","journal-title":"Cornea"},{"issue":"5","key":"10.1016\/j.clae.2021.101443_bib0155","doi-asserted-by":"crossref","first-page":"454","DOI":"10.1097\/OPX.0b013e31819f9e70","article-title":"Modeling corneal metabolism and oxygen transport during contact lens wear","volume":"86","author":"Chhabra","year":"2009","journal-title":"Optom Vis Sci"},{"issue":"1","key":"10.1016\/j.clae.2021.101443_bib0160","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1113\/jphysiol.1972.sp009737","article-title":"The location of the fluid pump in the cornea","volume":"221","author":"Maurice","year":"1972","journal-title":"J Physiol"},{"issue":"7","key":"10.1016\/j.clae.2021.101443_bib0165","doi-asserted-by":"crossref","first-page":"44","DOI":"10.1167\/tvst.9.7.44","article-title":"Limbal metabolic support reduces peripheral corneal edema with contact-lens wear","volume":"9","author":"Kim","year":"2020","journal-title":"Transl Vis Sci Technol"},{"issue":"1","key":"10.1016\/j.clae.2021.101443_bib0170","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.clae.2020.09.001","article-title":"Conjunctival prolapse during open eye scleral lens wear","volume":"44","author":"Fisher","year":"2021","journal-title":"Cont Lens Anterior Eye"},{"issue":"5","key":"10.1016\/j.clae.2021.101443_bib0175","doi-asserted-by":"crossref","first-page":"487","DOI":"10.1016\/0014-4835(90)90037-U","article-title":"Effects of ambient bicarbonate, phosphate and carbonic anhydrase inhibitors on fluid transport across rabbit corneal endothelium","volume":"50","author":"Kuang","year":"1990","journal-title":"Exp Eye Res"},{"key":"10.1016\/j.clae.2021.101443_bib0180","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1113\/jphysiol.1981.sp013971","article-title":"Stromal lactate accumulation can account for corneal oedema osmotically following epithelial hypoxia in the rabbit","volume":"321","author":"Klyce","year":"1981","journal-title":"J Physiol"},{"issue":"6","key":"10.1016\/j.clae.2021.101443_bib0185","doi-asserted-by":"crossref","first-page":"601","DOI":"10.3109\/02713688809031816","article-title":"Limited lateral spread of stromal edema in the human cornea fitted with a (\u2019donut\u2019) contact lens with a large central aperture","volume":"7","author":"Holden","year":"1988","journal-title":"Curr Eye Res"},{"key":"10.1016\/j.clae.2021.101443_bib0190","unstructured":"Hydrogel and silicone hydrogel lens general considerations. Contact Lens Spectrum. Published 2010. Accessed June 2, 2020. https:\/\/www.clspectrum.com\/supplements\/2010\/july-2010\/2010-contact-lenses-solutions-summary\/soft-contact-lenses."},{"key":"10.1016\/j.clae.2021.101443_bib0195","series-title":"Do scleral lenses provide adequate oxygen permeability for overnight lens wear?","author":"Nefedov","year":"2016"},{"issue":"1","key":"10.1016\/j.clae.2021.101443_bib0200","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1097\/00003226-200401000-00005","article-title":"Corneal swelling with overnight wear of scleral contact lenses","volume":"23","author":"Smith","year":"2004","journal-title":"Cornea"},{"key":"10.1016\/j.clae.2021.101443_bib0205","doi-asserted-by":"crossref","first-page":"107","DOI":"10.1113\/jphysiol.1979.sp012841","article-title":"Numerical solution of coupled transport equations applied to corneal hydration dynamics","volume":"292","author":"Klyce","year":"1979","journal-title":"J Physiol"},{"key":"10.1016\/j.clae.2021.101443_bib0210","unstructured":"Giedd B. Understanding the nuances of contact lens materials. Contact Lens Spectrum. Published 1999. Accessed June 23, 2020. https:\/\/www.clspectrum.com\/issues\/1999\/july-1999\/understanding-the-nuances-of-contact-lens-material."},{"issue":"12","key":"10.1016\/j.clae.2021.101443_bib0215","doi-asserted-by":"crossref","first-page":"1129","DOI":"10.3109\/02713683.2011.608240","article-title":"Continuous IOP fluctuation recording in normal tension glaucoma patients","volume":"36","author":"Pajic","year":"2011","journal-title":"Curr Eye Res"},{"key":"10.1016\/j.clae.2021.101443_bib0220","doi-asserted-by":"crossref","first-page":"3015","DOI":"10.1021\/ie000596z","article-title":"Dispersive mixing in the posterior tear film under a soft contact lens","volume":"40","author":"Creech","year":"2001","journal-title":"Ind Eng Chem Res"},{"issue":"2","key":"10.1016\/j.clae.2021.101443_bib0225","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1097\/ICL.0000000000000400","article-title":"Silicone hydrogel and rigid gas-permeable scleral lens tear exchange","volume":"44","author":"Paugh","year":"2018","journal-title":"Eye Contact Lens"},{"issue":"1","key":"10.1016\/j.clae.2021.101443_bib0230","doi-asserted-by":"crossref","DOI":"10.1016\/j.clae.2018.11.016","article-title":"Tear dynamics under scleral lenses","volume":"42","author":"Tse","year":"2019","journal-title":"Cont Lens Anterior Eye"},{"issue":"5540","key":"10.1016\/j.clae.2021.101443_bib0235","first-page":"1","article-title":"Contact lens-induced corneal oedema","volume":"211","author":"Efron","year":"1996","journal-title":"Optician"},{"issue":"9","key":"10.1016\/j.clae.2021.101443_bib0240","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1097\/OPX.0000000000001558","article-title":"Fluid reservoir thickness and corneal edema during open-eye scleral lens wear","volume":"97","author":"Fisher","year":"2020","journal-title":"Optom Vis Sci"},{"issue":"7","key":"10.1016\/j.clae.2021.101443_bib0245","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1098\/rsif.2005.0085","article-title":"Numerical simulation of corneal transport processes","volume":"3","author":"Li","year":"2006","journal-title":"J R Soc Interface R Soc"},{"key":"10.1016\/j.clae.2021.101443_bib0250","doi-asserted-by":"crossref","first-page":"1305","DOI":"10.1097\/ICO.0b013e31829b21d1","article-title":"Diurnal pattern of tear osmolarity and its relationship to corneal thickness and deswelling","volume":"32","author":"Niimi","year":"2013","journal-title":"Cornea"},{"key":"10.1016\/j.clae.2021.101443_bib0255","doi-asserted-by":"crossref","DOI":"10.1016\/j.biomaterials.2019.119285","article-title":"Topical sustained drug delivery to the retina with a drug-eluting contact lens","volume":"217","author":"Ross","year":"2019","journal-title":"Biomaterials"},{"key":"10.1016\/j.clae.2021.101443_bib0260","series-title":"Extended wear ophthalmic lens","author":"Nicolson","year":"1999"},{"issue":"6","key":"10.1016\/j.clae.2021.101443_bib0265","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.clae.2012.07.003","article-title":"Aqueous salt transport through soft contact lenses: an osmotic-withdrawal mechanism for prevention of adherence","volume":"35","author":"Cerretani","year":"2012","journal-title":"Cont Lens Anterior Eye"},{"key":"10.1016\/j.clae.2021.101443_bib0270","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1016\/j.clae.2018.03.002","article-title":"Scleral contact lens thickness profiles: the relationship between average and centre lens thickness","volume":"42","author":"Vincent","year":"2019","journal-title":"Cont Lens Anterior Eye"},{"issue":"2","key":"10.1016\/j.clae.2021.101443_bib0275","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1016\/j.clae.2014.12.002","article-title":"Importance of contact lens power and thickness in oxygen transmissibility","volume":"38","author":"Lira","year":"2015","journal-title":"Cont Lens Anterior Eye"}],"container-title":["Contact Lens and Anterior Eye"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048421000540?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048421000540?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T01:18:23Z","timestamp":1761268703000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1367048421000540"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,2]]},"references-count":55,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2022,2]]}},"alternative-id":["S1367048421000540"],"URL":"https:\/\/doi.org\/10.1016\/j.clae.2021.101443","relation":{},"ISSN":["1367-0484"],"issn-type":[{"value":"1367-0484","type":"print"}],"subject":[],"published":{"date-parts":[[2022,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Central-to-peripheral corneal edema during wear of embedded-component contact lenses","name":"articletitle","label":"Article Title"},{"value":"Contact Lens and Anterior Eye","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clae.2021.101443","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2021 The Authors. Published by Elsevier Ltd on behalf of British Contact Lens Association.","name":"copyright","label":"Copyright"}],"article-number":"101443"}}