{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T01:24:56Z","timestamp":1761269096568,"version":"build-2065373602"},"reference-count":64,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,10,1]],"date-time":"2023-10-01T00:00:00Z","timestamp":1696118400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,7,1]],"date-time":"2023-07-01T00:00:00Z","timestamp":1688169600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100013348","name":"Innosuisse - Schweizerische Agentur f\u00fcr Innovationsf\u00f6rderung","doi-asserted-by":"publisher","award":["KTI- 28143.1 PFLS- LS"],"award-info":[{"award-number":["KTI- 28143.1 PFLS- LS"]}],"id":[{"id":"10.13039\/501100013348","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","contactlensjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Contact Lens and Anterior Eye"],"published-print":{"date-parts":[[2023,10]]},"DOI":"10.1016\/j.clae.2023.101888","type":"journal-article","created":{"date-parts":[[2023,7,6]],"date-time":"2023-07-06T08:49:46Z","timestamp":1688633386000},"page":"101888","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Corneal sensitivity in silicone hydrogel and rigid gas permeable contact lens wear"],"prefix":"10.1016","volume":"46","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7995-2121","authenticated-orcid":false,"given":"Daniela S.","family":"Nosch","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Emanuele","family":"K\u00e4ser","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Alice","family":"Christen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Julia","family":"Schinzel","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Roland E.","family":"Joos","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.clae.2023.101888_b0005","doi-asserted-by":"crossref","first-page":"513","DOI":"10.1016\/j.exer.2003.09.023","article-title":"Neural basis of sensation in intact and injured corneas","volume":"78","author":"Belmonte","year":"2004","journal-title":"Exp Eye Res"},{"key":"10.1016\/j.clae.2023.101888_b0010","doi-asserted-by":"crossref","first-page":"2333","DOI":"10.1167\/iovs.03-1366","article-title":"Tear secretion induced by selective stimulation of corneal and conjunctival sensory nerve fibers","volume":"45","author":"Acosta","year":"2004","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0015","doi-asserted-by":"crossref","first-page":"920","DOI":"10.1016\/S0161-6420(80)35143-9","article-title":"Basic tear flow. Does it exist?","volume":"87","author":"Jordan","year":"1980","journal-title":"Ophthalmology"},{"key":"10.1016\/j.clae.2023.101888_b0020","doi-asserted-by":"crossref","first-page":"565","DOI":"10.1016\/S1350-9462(98)00004-4","article-title":"Tear dynamics and dry eye","volume":"17","author":"Tsubota","year":"1998","journal-title":"Prog Retin Eye Res"},{"key":"10.1016\/j.clae.2023.101888_b0025","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1111\/j.1755-3768.1989.tb04103.x","article-title":"Blinking and corneal sensitivity","volume":"67","author":"Collins","year":"1989","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.clae.2023.101888_b0030","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1016\/S0161-6420(81)34940-9","article-title":"Blinking and the mechanics of the lacrimal drainage system","volume":"88","author":"Doane","year":"1981","journal-title":"Ophthalmology"},{"issue":"4","key":"10.1016\/j.clae.2023.101888_b0035","doi-asserted-by":"crossref","first-page":"354","DOI":"10.1097\/00003226-199407000-00012","article-title":"Tear film lipid layer thickness as a function of blinking","volume":"13","author":"Korb","year":"1994","journal-title":"Cornea"},{"key":"10.1016\/j.clae.2023.101888_b0040","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1097\/OPX.0000000000000827","article-title":"Relationship between corneal sensation, blinking, and tear film quality","volume":"93","author":"Nosch","year":"2016","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0045","doi-asserted-by":"crossref","first-page":"521","DOI":"10.1016\/S0014-4835(03)00050-2","article-title":"Corneal nerves: structure, contents and function","volume":"76","author":"M\u00fcller","year":"2003","journal-title":"Exp Eye Res"},{"key":"10.1016\/j.clae.2023.101888_b0050","doi-asserted-by":"crossref","first-page":"555","DOI":"10.1016\/0306-4522(91)90397-7","article-title":"Trophic functions of primary sensory neurons: Are they really local?","volume":"42","author":"Knyazev","year":"1991","journal-title":"Neuroscience"},{"key":"10.1016\/j.clae.2023.101888_b0055","doi-asserted-by":"crossref","first-page":"264","DOI":"10.1097\/00003226-200104000-00006","article-title":"The effect of long-term, daily contact lens wear on corneal sensitivity","volume":"20","author":"Murphy","year":"2001","journal-title":"Cornea"},{"key":"10.1016\/j.clae.2023.101888_b0060","first-page":"212","article-title":"The effect of rigid gas permeable lenses on corneal sensitivity","volume":"58","author":"Bergenske","year":"1987","journal-title":"J Am Optom Assoc"},{"key":"10.1016\/j.clae.2023.101888_b0065","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1111\/j.1755-3768.1994.tb02737.x","article-title":"Variations in corneal sensitivity with hydrogel contact lenses","volume":"72","author":"Velasco","year":"1994","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.clae.2023.101888_b0070","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1111\/j.1755-3768.1974.tb01096.x","article-title":"Effect of soft lenses on corneal sensitivity","volume":"52","author":"Millodot","year":"1974","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.clae.2023.101888_b0075","doi-asserted-by":"crossref","first-page":"434","DOI":"10.1111\/j.1755-3768.1980.tb05744.x","article-title":"Effect of oxygen deprivation on corneal sensitivity","volume":"58","author":"Millodot","year":"1980","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.clae.2023.101888_b0080","first-page":"1202","article-title":"Etiology of corneal sensitivity changes accompanying contact lens wear","volume":"17","author":"Polse","year":"1978","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0085","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1097\/OPX.0000000000000016","article-title":"Corneal sensitivity with contact lenses of different mechanical properties","volume":"90","author":"Lum","year":"2013","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0090","doi-asserted-by":"crossref","first-page":"699","DOI":"10.1097\/00006324-199109000-00004","article-title":"Esthesiometry as an indicator of corneal health","volume":"68","author":"Brennan","year":"1991","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0095","doi-asserted-by":"crossref","first-page":"1547","DOI":"10.1136\/bjo.2004.044024","article-title":"Corneal and conjunctival sensitivity to air stimuli","volume":"88","author":"Stapleton","year":"2004","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.clae.2023.101888_b0100","doi-asserted-by":"crossref","first-page":"6111","DOI":"10.1167\/iovs.09-4807","article-title":"Effects of silicone hydrogel contact lens wear on ocular surface sensitivity to tactile, pneumatic mechanical, and chemical stimulation","volume":"51","author":"Situ","year":"2010","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0105","doi-asserted-by":"crossref","first-page":"721","DOI":"10.1111\/j.1755-3768.1976.tb01791.x","article-title":"Effect of length of wear of contact lenses on corneal sensitivity","volume":"54","author":"Millodot","year":"1976","journal-title":"Acta Ophthalmol"},{"key":"10.1016\/j.clae.2023.101888_b0110","doi-asserted-by":"crossref","first-page":"1475","DOI":"10.1007\/BF01918817","article-title":"Does the long term wear of contact lenses produce a loss of corneal sensitivity?","volume":"33","author":"Millodot","year":"1977","journal-title":"Experientia"},{"key":"10.1016\/j.clae.2023.101888_b0115","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1001\/archopht.1978.03910060059011","article-title":"Effect of long-term wear of hard contact lenses on corneal sensitivity","volume":"96","author":"Millodot","year":"1978","journal-title":"Arch Ophthalmol"},{"issue":"10","key":"10.1016\/j.clae.2023.101888_b0120","doi-asserted-by":"crossref","first-page":"628","DOI":"10.1097\/00006324-197910000-00004","article-title":"Measurement of corneal sensitivity and thickness with PMMA and gas-permeable contact lenses","volume":"56","author":"Millodot","year":"1979","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0125","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1016\/S0141-7037(86)80009-X","article-title":"The effect of hard and gas permeable contact lenses on refractive error, corneal curvature, thickness and sensitivity","volume":"9","author":"Douthwaite","year":"1986","journal-title":"J Br Contact Lens Assoc"},{"key":"10.1016\/j.clae.2023.101888_b0130","doi-asserted-by":"crossref","first-page":"328","DOI":"10.1159\/000027317","article-title":"Corneal sensitivity changes in long-term wearing of hard polymethylmethacrylate contact lenses","volume":"212","author":"Sanaty","year":"1998","journal-title":"Ophthalmologica"},{"key":"10.1016\/j.clae.2023.101888_b0135","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1136\/bjo.63.7.475","article-title":"Some clinically observed phenomena in extended contact lens wear","volume":"63","author":"Larke","year":"1979","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.clae.2023.101888_b0140","doi-asserted-by":"crossref","first-page":"1177","DOI":"10.1167\/iovs.11-8416","article-title":"Corneal and conjunctival sensory function: The impact on ocular surface sensitivity of change from low to high oxygen transmissibility contact lenses","volume":"53","author":"Golebiowski","year":"2012","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0145","first-page":"541","article-title":"L\u2019esth\u00e9seiom\u00e9trie corn\u00e9enne. R\u00e9alisation et int\u00e9r\u00eat pratique","volume":"6","author":"Cochet","year":"1961","journal-title":"Bull Soc d\u2019Ophtalmol France"},{"key":"10.1016\/j.clae.2023.101888_b0150","first-page":"532","article-title":"Reliability of the non-contact corneal aesthesiometer and its comparison with the Cochet-Bonnet aesthesiometer","volume":"18","author":"Murphy","year":"1998","journal-title":"Ophth Physiol Optics"},{"key":"10.1016\/j.clae.2023.101888_b0155","first-page":"5","article-title":"Effect of bending of the nylon thread of the Cochet-Bonnet aesthesiometer upon the recorded pressure","volume":"1","author":"Millodot","year":"1967","journal-title":"Contact Lens"},{"key":"10.1016\/j.clae.2023.101888_b0160","doi-asserted-by":"crossref","first-page":"408","DOI":"10.1016\/j.exer.2011.02.016","article-title":"Assessing the sensory function of the ocular surface: Implications of use of a non-contact air jet aesthesiometer versus the Cochet-Bonnet aesthesiometer","volume":"92","author":"Golebiowski","year":"2011","journal-title":"Exp Eye Res"},{"key":"10.1016\/j.clae.2023.101888_b0165","doi-asserted-by":"crossref","first-page":"1644","DOI":"10.1038\/s41433-018-0150-z","article-title":"Effects of ambient humidity on the Cochet-Bonnet aesthesiometer","volume":"32","author":"Lum","year":"2018","journal-title":"Eye"},{"key":"10.1016\/j.clae.2023.101888_b0170","first-page":"513","article-title":"Measurement of corneal sensitivity to mechanical and chemical stimulation with a CO2 esthesiometer","volume":"40","author":"Belmonte","year":"1999","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0175","doi-asserted-by":"crossref","first-page":"529","DOI":"10.1167\/iovs.02-0003","article-title":"Nociceptive sensation and sensitivity evoked from human cornea and conjunctiva stimulated by CO 2","volume":"44","author":"Feng","year":"2003","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0180","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1046\/j.1475-1313.1996.95001026.x","article-title":"A new non-contact corneal aesthesiometer","volume":"16","author":"Murphy","year":"1996","journal-title":"Ophthalmic Physiol Opt"},{"key":"10.1016\/j.clae.2023.101888_b0185","doi-asserted-by":"crossref","first-page":"675","DOI":"10.1097\/00003226-199911000-00009","article-title":"A noncontact pneumatic esthesiometer for measurement of ocular sensitivity: A preliminary report","volume":"18","author":"Vega","year":"1999","journal-title":"Cornea"},{"key":"10.1016\/j.clae.2023.101888_b0190","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1111\/cxo.12603","article-title":"Does air gas aesthesiometry generate a true mechanical stimulus for corneal sensitivity measurement?","volume":"101","author":"Nosch","year":"2018","journal-title":"Clin Exp Optom"},{"key":"10.1016\/j.clae.2023.101888_b0195","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1111\/opo.12025","article-title":"Understanding the stimulus of an air-jet aesthesiometer: computerised modelling and subjective interpretation","volume":"33","author":"Golebiowski","year":"2013","journal-title":"Ophthalmic Physiol Opt"},{"key":"10.1016\/j.clae.2023.101888_b0200","doi-asserted-by":"crossref","first-page":"609","DOI":"10.1111\/opo.12962","article-title":"Working principle and relevant physical properties of the Swiss Liquid Jet Aesthesiometer for Corneal Sensitivity (SLACS) evaluation","volume":"42","author":"Nosch","year":"2022","journal-title":"Ophthalmic Physiol Opt"},{"key":"10.1016\/j.clae.2023.101888_b0205","article-title":"Clinical application of the new Swiss Liquid Jet Aesthesiometer for corneal sensitivity measurement","author":"Nosch","year":"2023","journal-title":"Clin Exp Optom"},{"key":"10.1016\/j.clae.2023.101888_b0210","doi-asserted-by":"crossref","first-page":"615","DOI":"10.1001\/archopht.118.5.615","article-title":"Reliability and validity of the Ocular Surface Disease Index","volume":"118","author":"Schiffman","year":"2000","journal-title":"Arch Ophthalmol"},{"key":"10.1016\/j.clae.2023.101888_b0215","first-page":"140","article-title":"The influence of age on the sensitivity of the cornea","volume":"16","author":"Millodot","year":"1977","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0220","doi-asserted-by":"crossref","first-page":"350","DOI":"10.1159\/000079478","article-title":"Age-related modifications of corneal sensitivity","volume":"218","author":"Roszkowska","year":"2004","journal-title":"Ophthalmologica"},{"key":"10.1016\/j.clae.2023.101888_b0225","doi-asserted-by":"crossref","first-page":"932","DOI":"10.1016\/j.exer.2006.04.018","article-title":"Influence of age, gender and iris color on mechanical and chemical sensitivity of the cornea and conjunctiva","volume":"83","author":"Acosta","year":"2006","journal-title":"Exp Eye Res"},{"key":"10.1016\/j.clae.2023.101888_b0230","doi-asserted-by":"crossref","first-page":"1737","DOI":"10.1167\/iovs.03-0689","article-title":"Noninvasive assessment of corneal sensitivity in young and elderly diabetic and nondiabetic subjects","volume":"45","author":"Murphy","year":"2004","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0235","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1097\/ICO.0b013e318193e0e3","article-title":"Corneal sensitivity and slit scanning in vivo confocal microscopy of the subbasal nerve plexus of the normal central and peripheral human cornea","volume":"28","author":"Patel","year":"2009","journal-title":"Cornea"},{"key":"10.1016\/j.clae.2023.101888_b0240","doi-asserted-by":"crossref","first-page":"E241","DOI":"10.1097\/OPX.0b013e3181694f96","article-title":"Factors affecting corneal and conjunctival sensitivity measurement","volume":"85","author":"Golebiowski","year":"2008","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0245","doi-asserted-by":"crossref","first-page":"844","DOI":"10.1136\/bjo.56.11.844","article-title":"Diurnal variation of corneal sensitivity","volume":"56","author":"Millodot","year":"1972","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.clae.2023.101888_b0250","doi-asserted-by":"crossref","first-page":"1435","DOI":"10.1097\/OPX.0b013e318269c90d","article-title":"Contact Lens Dry Eye Questionnaire-8 (CLDEQ-8) and opinion of contact lens performance","volume":"89","author":"Chalmers","year":"2012","journal-title":"Optom Vis Sci"},{"issue":"3","key":"10.1016\/j.clae.2023.101888_b0255","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1016\/j.jtos.2017.05.002","article-title":"TFOS DEWS II pain and sensation report","volume":"15","author":"Belmonte","year":"2017","journal-title":"Ocul Surf"},{"key":"10.1016\/j.clae.2023.101888_b0260","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1016\/S1542-0124(12)70112-X","article-title":"Nerves and sensations from the eye surface","volume":"2","author":"Belmonte","year":"2004","journal-title":"Ocul Surf"},{"key":"10.1016\/j.clae.2023.101888_b0265","doi-asserted-by":"crossref","unstructured":"Nosch DS, K\u00e4ser E, Bracher T, Joos RE. Age-related changes in corneal sensitivity. Cornea 2022;Epub ahead of print. https:\/\/doi.org\/10.1097\/ICO.0000000000003183.","DOI":"10.1097\/ICO.0000000000003183"},{"key":"10.1016\/j.clae.2023.101888_b0270","doi-asserted-by":"crossref","first-page":"117","DOI":"10.1016\/S1350-9462(96)00027-4","article-title":"Neurobiology of ocular pain","volume":"16","author":"Belmonte","year":"1997","journal-title":"Prog Retin Eye Res"},{"key":"10.1016\/j.clae.2023.101888_b0275","doi-asserted-by":"crossref","unstructured":"Murphy PJ, Morgan PB, Patel S, Marshall J. Corneal surface temperature change as the mode of stimulation of the Non-Contact Corneal Aesthesiometer. Cornea 1999;18:333\u201342. https:\/\/doi.org\/0.1097\/00003226-199905000-00016.","DOI":"10.1097\/00003226-199905000-00016"},{"key":"10.1016\/j.clae.2023.101888_b0280","doi-asserted-by":"crossref","first-page":"493","DOI":"10.1136\/bjo.47.8.493","article-title":"Corneal sensitivity and contact lenses","volume":"47","author":"Schirmer","year":"1963","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.clae.2023.101888_b0285","first-page":"305","article-title":"A review of research on the sensitivity of the cornea","volume":"4","author":"Millodot","year":"1984","journal-title":"Oph Phys Optics"},{"key":"10.1016\/j.clae.2023.101888_b0290","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1097\/01.opx.0000171817.32551.05","article-title":"The association between eye color and corneal sensitivity measured using a Belmonte Esthesiometer","volume":"82","author":"Henderson","year":"2005","journal-title":"Optom Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0295","doi-asserted-by":"crossref","first-page":"102","DOI":"10.4103\/2008-322X.163772","article-title":"Is corneal sensitivity sex dependent?","volume":"10","author":"Khezri","year":"2015","journal-title":"J Ophthalmic Vis Res"},{"key":"10.1016\/j.clae.2023.101888_b0300","doi-asserted-by":"crossref","first-page":"51","DOI":"10.3109\/13816818509004117","article-title":"Interindividual differences of corneal sensitivity Genetic aspects","volume":"6","author":"Draeger","year":"1985","journal-title":"Ophthalmic Paediatr Genet"},{"key":"10.1016\/j.clae.2023.101888_b0305","doi-asserted-by":"crossref","first-page":"38","DOI":"10.1111\/j.1475-1313.1994.tb00555.x","article-title":"Changes in ocular and visual variables during the menstrual cycle","volume":"14","author":"Guttridge","year":"1994","journal-title":"Oph Phys Optics"},{"key":"10.1016\/j.clae.2023.101888_b0310","doi-asserted-by":"crossref","first-page":"1200","DOI":"10.1167\/iovs.10-5349","article-title":"A role of corneal mechanical adaptation in contact lens\u2013related dry eye symptoms","volume":"52","author":"Chen","year":"2011","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2023.101888_b0315","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1038\/255151a0","article-title":"Do blue-eyed people have more sensitive corneas than brown-eyed people?","volume":"255","author":"Millodot","year":"1975","journal-title":"Nature"},{"key":"10.1016\/j.clae.2023.101888_b0320","doi-asserted-by":"crossref","first-page":"674","DOI":"10.1097\/ICO.0000000000001933","article-title":"Relationship between the degree of iris pigmentation and corneal sensitivity to a cooling stimulus","volume":"38","author":"Ntola","year":"2019","journal-title":"Cornea"}],"container-title":["Contact Lens and Anterior Eye"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048423001121?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048423001121?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,24]],"date-time":"2025-10-24T01:22:03Z","timestamp":1761268923000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1367048423001121"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,10]]},"references-count":64,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2023,10]]}},"alternative-id":["S1367048423001121"],"URL":"https:\/\/doi.org\/10.1016\/j.clae.2023.101888","relation":{},"ISSN":["1367-0484"],"issn-type":[{"type":"print","value":"1367-0484"}],"subject":[],"published":{"date-parts":[[2023,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Corneal sensitivity in silicone hydrogel and rigid gas permeable contact lens wear","name":"articletitle","label":"Article Title"},{"value":"Contact Lens and Anterior Eye","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clae.2023.101888","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Author(s). Published by Elsevier Ltd on behalf of British Contact Lens Association.","name":"copyright","label":"Copyright"}],"article-number":"101888"}}