{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,10]],"date-time":"2025-10-10T07:22:16Z","timestamp":1760080936208,"version":"3.37.3"},"reference-count":28,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,6,1]],"date-time":"2024-06-01T00:00:00Z","timestamp":1717200000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100005024","name":"Beijing Postdoctoral Research Foundation","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100005024","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100009592","name":"Beijing Municipal Science and Technology Commission","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100009592","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","contactlensjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Contact Lens and Anterior Eye"],"published-print":{"date-parts":[[2024,6]]},"DOI":"10.1016\/j.clae.2024.102134","type":"journal-article","created":{"date-parts":[[2024,3,11]],"date-time":"2024-03-11T21:54:35Z","timestamp":1710194075000},"page":"102134","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"title":["The biomechanical proteins different between low myopic corneas and moderate to high myopic corneas in human"],"prefix":"10.1016","volume":"47","author":[{"given":"Wenjing","family":"Wu","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yan","family":"Wang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jingyi","family":"Chen","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-3715-4164","authenticated-orcid":false,"given":"Fengju","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.clae.2024.102134_b0005","doi-asserted-by":"crossref","first-page":"269","DOI":"10.1146\/annurev-bioeng-070909-105243","article-title":"Corneal biomechanics and biomaterials","volume":"13","author":"Ruberti","year":"2011","journal-title":"Annu Rev Biomed Eng"},{"key":"10.1016\/j.clae.2024.102134_b0010","doi-asserted-by":"crossref","DOI":"10.1155\/2015\/758196","article-title":"The correlation analysis between corneal biomechanical properties and the surgically induced corneal high-order aberrations after small incision lenticule extraction and femtosecond laser in situ keratomileusis","volume":"2015","author":"Wu","year":"2015","journal-title":"J Ophthalmol"},{"key":"10.1016\/j.clae.2024.102134_b0015","doi-asserted-by":"crossref","first-page":"749","DOI":"10.3928\/1081-597X-20051101-15","article-title":"Keratoconus and corneal ectasia after LASIK","volume":"21","author":"Binder","year":"2005","journal-title":"J Refract Surg"},{"key":"10.1016\/j.clae.2024.102134_b0020","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1167\/tvst.7.5.11","article-title":"Predicting refractive outcome of small incision lenticule extraction for myopia using corneal properties","volume":"7","author":"Wang","year":"2018","journal-title":"Transl vis Sci Technol"},{"key":"10.1016\/j.clae.2024.102134_b0025","doi-asserted-by":"crossref","first-page":"419","DOI":"10.1016\/j.ajo.2019.07.007","article-title":"Comparison of corneal biomechanics between low and high myopic eyes-a meta-analysis","volume":"207","author":"Wu","year":"2019","journal-title":"Am J Ophthalmol"},{"key":"10.1016\/j.clae.2024.102134_b0030","article-title":"Corneal biomechanical properties in varying severities of myopia","volume":"8","author":"Sedaghat","year":"2020","journal-title":"Front Bioeng Biotechnol"},{"key":"10.1016\/j.clae.2024.102134_b0035","doi-asserted-by":"crossref","first-page":"299","DOI":"10.1016\/S0140-6736(16)30958-8","article-title":"Lung cancer: current therapies and new targeted treatments","volume":"389","author":"Hirsch","year":"2017","journal-title":"Lancet"},{"key":"10.1016\/j.clae.2024.102134_b0040","doi-asserted-by":"crossref","first-page":"2213","DOI":"10.1158\/1078-0432.CCR-14-2748","article-title":"Lung cancer in the era of precision medicine","volume":"21","author":"Politi","year":"2015","journal-title":"Clin Cancer Res"},{"key":"10.1016\/j.clae.2024.102134_b0045","doi-asserted-by":"crossref","first-page":"e010993","DOI":"10.1136\/bmjopen-2015-010993","article-title":"One-year visual outcome of small incision lenticule extraction (SMILE) surgery in high myopic eyes: retrospective cohort study","volume":"6","author":"Wu","year":"2016","journal-title":"BMJ Open"},{"key":"10.1016\/j.clae.2024.102134_b0050","article-title":"Novel corneal protein biomarker candidates reveal iron metabolic disturbance in high myopia eyes","volume":"9","author":"Chen","year":"2021","journal-title":"Front Cell Dev Biol"},{"key":"10.1016\/j.clae.2024.102134_b0055","first-page":"534","article-title":"Linkage and association of myocilin (MYOC) polymorphisms with high myopia in a chinese population","volume":"13","author":"Tang","year":"2007","journal-title":"Mol vis"},{"key":"10.1016\/j.clae.2024.102134_b0060","doi-asserted-by":"crossref","first-page":"e0214791","DOI":"10.1371\/journal.pone.0214791","article-title":"In-utero epigenetic factors are associated with early-onset myopia in young children","volume":"14","author":"Seow","year":"2019","journal-title":"PLoS One"},{"key":"10.1016\/j.clae.2024.102134_b0065","article-title":"Candidate molecular compounds as potential indicators for meibomian gland dysfunction","volume":"9","author":"Asiedu","year":"2022","journal-title":"Front Med (lausanne)"},{"key":"10.1016\/j.clae.2024.102134_b0070","doi-asserted-by":"crossref","first-page":"999","DOI":"10.1136\/bjophthalmol-2019-314466","article-title":"Histopathology and selective biomarker expression in human meibomian glands","volume":"104","author":"Reneker","year":"2020","journal-title":"Br J Ophthalmol"},{"key":"10.1016\/j.clae.2024.102134_b0075","doi-asserted-by":"crossref","first-page":"94","DOI":"10.1016\/0955-0674(92)90064-J","article-title":"Intermediate filament structure","volume":"4","author":"Parry","year":"1992","journal-title":"Curr Opin Cell Biol"},{"key":"10.1016\/j.clae.2024.102134_b0080","doi-asserted-by":"crossref","DOI":"10.1101\/cshperspect.a030288","article-title":"Overview of the cytoskeleton from an evolutionary perspective","volume":"10","author":"Pollard","year":"2018","journal-title":"Cold Spring Harb Perspect Biol"},{"key":"10.1016\/j.clae.2024.102134_b0085","doi-asserted-by":"crossref","DOI":"10.7554\/eLife.58149","article-title":"Keratins and the plakin family cytolinker proteins control the length of epithelial microridge protrusions","volume":"9","author":"Inaba","year":"2020","journal-title":"Elife"},{"key":"10.1016\/j.clae.2024.102134_b0090","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1007\/s12195-018-0526-y","article-title":"Mouse keratinocytes without keratin intermediate filaments demonstrate substrate stiffness dependent behaviors","volume":"11","author":"Zarkoob","year":"2018","journal-title":"Cell Mol Bioeng"},{"key":"10.1016\/j.clae.2024.102134_b0095","doi-asserted-by":"crossref","DOI":"10.15252\/embj.2018100741","article-title":"Human keratin 1\/10-1B tetramer structures reveal a knob-pocket mechanism in intermediate filament assembly","volume":"38","author":"Eldirany","year":"2019","journal-title":"EMBO J"},{"key":"10.1016\/j.clae.2024.102134_b0100","doi-asserted-by":"crossref","first-page":"18513","DOI":"10.1073\/pnas.1313491110","article-title":"Keratins as the main component for the mechanical integrity of keratinocytes","volume":"110","author":"Ramms","year":"2013","journal-title":"Proc Natl Acad Sci U S A"},{"key":"10.1016\/j.clae.2024.102134_b0105","doi-asserted-by":"crossref","first-page":"273","DOI":"10.1186\/s12886-022-02497-6","article-title":"Posterior scleral reinforcement for the treatment of myopic traction maculopathy","volume":"22","author":"He","year":"2022","journal-title":"BMC Ophthalmol"},{"key":"10.1016\/j.clae.2024.102134_b0110","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1038\/eye.2013.223","article-title":"Histological changes of high axial myopia","volume":"28","author":"Jonas","year":"2014","journal-title":"Eye (lond)"},{"key":"10.1016\/j.clae.2024.102134_b0115","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.exer.2014.07.015","article-title":"The dynamic sclera: extracellular matrix remodeling in normal ocular growth and myopia development","volume":"133","author":"Harper","year":"2015","journal-title":"Exp Eye Res"},{"key":"10.1016\/j.clae.2024.102134_b0120","doi-asserted-by":"crossref","first-page":"E7091","DOI":"10.1073\/pnas.1721443115","article-title":"Scleral hypoxia is a target for myopia control","volume":"115","author":"Wu","year":"2018","journal-title":"Proc Natl Acad Sci U S A"},{"key":"10.1016\/j.clae.2024.102134_b0125","doi-asserted-by":"crossref","first-page":"e0207189","DOI":"10.1371\/journal.pone.0207189","article-title":"High myopia induced by form deprivation is associated with altered corneal biomechanical properties in chicks","volume":"13","author":"Kang","year":"2018","journal-title":"PLoS One"},{"key":"10.1016\/j.clae.2024.102134_b0130","doi-asserted-by":"crossref","first-page":"132","DOI":"10.1097\/00006324-199802000-00017","article-title":"Role of the cornea in emmetropia and myopia","volume":"75","author":"Grosvenor","year":"1998","journal-title":"Optom vis Sci"},{"key":"10.1016\/j.clae.2024.102134_b0135","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1186\/1471-2415-14-11","article-title":"Biomechanical parameters of the cornea measured with the ocular response analyzer in normal eyes","volume":"14","author":"Kotecha","year":"2014","journal-title":"BMC Ophthalmol"},{"key":"10.1016\/j.clae.2024.102134_b0140","doi-asserted-by":"crossref","first-page":"3498","DOI":"10.1016\/j.bpj.2021.05.010","article-title":"Biophysical properties of corneal cells reflect high myopia progression","volume":"120","author":"Xin","year":"2021","journal-title":"Biophys J"}],"container-title":["Contact Lens and Anterior Eye"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048424000171?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048424000171?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,6,15]],"date-time":"2024-06-15T18:57:51Z","timestamp":1718477871000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1367048424000171"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,6]]},"references-count":28,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2024,6]]}},"alternative-id":["S1367048424000171"],"URL":"https:\/\/doi.org\/10.1016\/j.clae.2024.102134","relation":{},"ISSN":["1367-0484"],"issn-type":[{"type":"print","value":"1367-0484"}],"subject":[],"published":{"date-parts":[[2024,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The biomechanical proteins different between low myopic corneas and moderate to high myopic corneas in human","name":"articletitle","label":"Article Title"},{"value":"Contact Lens and Anterior Eye","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clae.2024.102134","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 British Contact Lens Association. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}],"article-number":"102134"}}