{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T03:05:04Z","timestamp":1789700704398,"version":"4.0.1"},"reference-count":42,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,10,1]],"date-time":"2026-10-01T00:00:00Z","timestamp":1790812800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","contactlensjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Contact Lens and Anterior Eye"],"published-print":{"date-parts":[[2026,10]]},"DOI":"10.1016\/j.clae.2026.102830","type":"journal-article","created":{"date-parts":[[2026,8,29]],"date-time":"2026-08-29T03:21:29Z","timestamp":1787973689000},"page":"102830","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"title":["OcuTOP: a novel handheld corneal topography device with misalignment correction"],"prefix":"10.1016","volume":"49","author":[{"given":"Vimal Manoharan","family":"Nair","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yabo","family":"Ye","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yuanwan","family":"Lou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Makarem","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ahmed","family":"Elsheikh","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"3","key":"10.1016\/j.clae.2026.102830_bb0005","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1016\/j.jcrs.2010.12.037","article-title":"Anatomy and physiology of the cornea","volume":"37","author":"DelMonte","year":"2011","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"10.1016\/j.clae.2026.102830_bb0010","doi-asserted-by":"crossref","first-page":"770","DOI":"10.1016\/j.survophthal.2017.06.009","article-title":"A review of keratoconus: diagnosis, pathophysiology, and genetics","volume":"62","author":"Mas Tur","year":"2017","journal-title":"Surv Ophthalmol"},{"issue":"4","key":"10.1016\/j.clae.2026.102830_bb0015","doi-asserted-by":"crossref","first-page":"359","DOI":"10.1097\/ICO.0000000000000408","article-title":"Global consensus on keratoconus and ectatic diseases","volume":"34","author":"Gomes","year":"2015","journal-title":"Cornea"},{"issue":"4","key":"10.1016\/j.clae.2026.102830_bb0020","doi-asserted-by":"crossref","first-page":"293","DOI":"10.1016\/0039-6257(84)90094-8","article-title":"Keratoconus and related noninflammatory cornea1 thinning disorders","volume":"28","author":"Krachmer","year":"1984","journal-title":"Surv Ophthalmol"},{"issue":"2","key":"10.1016\/j.clae.2026.102830_bb0025","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1111\/ceo.13136","article-title":"Applications of corneal topography and tomography: a review","volume":"46","author":"Fan","year":"2018","journal-title":"Clin Exp Ophthalmol"},{"issue":"4","key":"10.1016\/j.clae.2026.102830_bb0030","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1097\/00055735-200008000-00006","article-title":"Understanding corneal topography","volume":"11","author":"Rao","year":"2020","journal-title":"Curr Opin Ophthalmol"},{"issue":"5","key":"10.1016\/j.clae.2026.102830_bb0035","first-page":"705","article-title":"Quantitative evaluation of irregular astigmatism by Fourier series harmonic analysis of videokeratography data","volume":"39","author":"Oshika","year":"1998","journal-title":"Invest Ophthalmol Vis Sci"},{"key":"10.1016\/j.clae.2026.102830_bb0040","doi-asserted-by":"crossref","first-page":"752","DOI":"10.1016\/j.ophtha.2003.06.019","article-title":"Corneal regular and irregular astigmatism assessed by Fourier analysis of videokeratography data in normal and pathologic eyes","volume":"111","author":"Tanabe","year":"2004","journal-title":"Ophthalmology"},{"issue":"10","key":"10.1016\/j.clae.2026.102830_bb0045","doi-asserted-by":"crossref","first-page":"1327","DOI":"10.1016\/S0886-3350(99)00195-9","article-title":"KISA% index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus","volume":"25","author":"Rabinowitz","year":"1999","journal-title":"J Cataract Refract Surg"},{"issue":"6","key":"10.1016\/j.clae.2026.102830_bb0050","first-page":"2749","article-title":"Automated keratoconus screening with corneal topography analysis","volume":"35","author":"Maeda","year":"1994","journal-title":"Invest Ophthalmol Vis Sci"},{"issue":"5","key":"10.1016\/j.clae.2026.102830_bb0055","doi-asserted-by":"crossref","first-page":"813","DOI":"10.1016\/j.ajo.2007.12.033","article-title":"Validation of the ectasia risk score system for preoperative laser in situ keratomileusis screening","volume":"145","author":"Randleman","year":"2008","journal-title":"Am J Ophthalmol"},{"issue":"4","key":"10.1016\/j.clae.2026.102830_bb0060","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/S0886-3350(97)80204-0","article-title":"Topographical analysis of ablation centration after excimer laser photorefractive keratectomy and laser in situ keratomileusis for high myopia","volume":"23","author":"Mulhern","year":"1997","journal-title":"J Cataract Refract Surg"},{"issue":"5","key":"10.1016\/j.clae.2026.102830_bb0065","doi-asserted-by":"crossref","first-page":"806","DOI":"10.1016\/j.ajo.2003.11.077","article-title":"Topographically supported customized ablation for the management of decentered laser in situ keratomileusis","volume":"137","author":"Kymionis","year":"2004","journal-title":"Am J Ophthalmol"},{"issue":"7","key":"10.1016\/j.clae.2026.102830_bb0070","doi-asserted-by":"crossref","first-page":"904","DOI":"10.1016\/S0886-3350(99)00090-5","article-title":"Diurnal fluctuations in corneal topography 10 years after radial keratotomy in the prospective evaluation of radial keratotomy study","volume":"25","author":"Kemp","year":"1999","journal-title":"J Cataract Refract Surg"},{"issue":"3","key":"10.1016\/j.clae.2026.102830_bb0075","doi-asserted-by":"crossref","first-page":"351","DOI":"10.1001\/archopht.1992.01080150049026","article-title":"Diurnal variation of corneal topography after radial keratotomy","volume":"110","author":"Kwitko","year":"1992","journal-title":"Arch Ophthalmol"},{"issue":"7","key":"10.1016\/j.clae.2026.102830_bb0080","doi-asserted-by":"crossref","first-page":"1029","DOI":"10.1007\/s00417-009-1272-6","article-title":"Limbal relaxing incision during cataract extraction versus photoastigmatic keratectomy after cataract extraction in controlling pre-existing corneal astigmatism","volume":"248","author":"Fouda","year":"2010","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"key":"10.1016\/j.clae.2026.102830_bb0085","doi-asserted-by":"crossref","unstructured":"Carvalho M.J, Suzuki S.H, Freitas L.L, Branco B.C, Schor P, Lima A.L.H. Limbal relaxing incisions to correct corneal astigmatism during phacoemulsification.J Refract Surg, 23, 2007:499\u2013504, doi:10.3928\/1081-597X-20070501-14.","DOI":"10.3928\/1081-597X-20070501-14"},{"key":"10.1016\/j.clae.2026.102830_bb0090","first-page":"2019","article-title":"Keratoconus: current perspectives","volume":"7","author":"Vazirani","year":"2013","journal-title":"Clin Ophthalmol"},{"issue":"4","key":"10.1016\/j.clae.2026.102830_bb0095","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1016\/j.clae.2007.06.003","article-title":"The application of a computerised videokeratography (CVK) based contact lens fitting software programme on irregularly shaped corneal surfaces","volume":"30","author":"Nosch","year":"2007","journal-title":"Contact Lens Anterior Eye"},{"issue":"3","key":"10.1016\/j.clae.2026.102830_bb0100","doi-asserted-by":"crossref","first-page":"128","DOI":"10.1016\/j.clae.2009.11.004","article-title":"A comparison of a topography-based rigid gas permeable contact lens design with a conventionally fitted lens in patients with keratoconus","volume":"33","author":"Bhatoa","year":"2010","journal-title":"Contact Lens Anterior Eye"},{"key":"10.1016\/j.clae.2026.102830_bb0105","doi-asserted-by":"crossref","first-page":"1421361","DOI":"10.3389\/fmed.2024.1421361","article-title":"Analysis of corneal surface shape following overnight orthokeratology with different optical zone diameters","volume":"11","author":"Chen","year":"2024","journal-title":"Front Med"},{"issue":"5","key":"10.1016\/j.clae.2026.102830_bb0110","doi-asserted-by":"crossref","first-page":"620","DOI":"10.1016\/S0002-9394(02)02220-1","article-title":"Riboflavin\/ultraviolet-a\u2013induced collagen crosslinking for the treatment of keratoconus","volume":"135","author":"Wollensak","year":"2003","journal-title":"Am J Ophthalmol"},{"issue":"9","key":"10.1016\/j.clae.2026.102830_bb0115","doi-asserted-by":"crossref","first-page":"1259","DOI":"10.1016\/j.ophtha.2017.03.052","article-title":"United States multicenter clinical trial of corneal collagen crosslinking for keratoconus treatment","volume":"124","author":"Hersh","year":"2017","journal-title":"Ophthalmology"},{"issue":"2","key":"10.1016\/j.clae.2026.102830_bb0120","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.jtos.2013.01.003","article-title":"Corneal crosslinking with riboflavin and ultraviolet A. Part II. Clinical indications and results","volume":"11","author":"Raiskup","year":"2013","journal-title":"Ocul Surf"},{"key":"10.1016\/j.clae.2026.102830_bb0125","doi-asserted-by":"crossref","first-page":"169","DOI":"10.1016\/j.ajo.2016.12.015","article-title":"Age-specific incidence and prevalence of keratoconus: a nationwide registration study","volume":"175","author":"Godefrooij","year":"2017","journal-title":"Am J Ophthalmol"},{"issue":"4","key":"10.1016\/j.clae.2026.102830_bb0130","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/3494982","article-title":"Smartkc: smartphone-based corneal topographer for keratoconus detection","volume":"5","author":"Gairola","year":"2021","journal-title":"Proc ACM Interact Mob Wear Ubiquitous Technol"},{"issue":"3","key":"10.1016\/j.clae.2026.102830_bb0135","doi-asserted-by":"crossref","DOI":"10.3390\/s22031181","article-title":"Developing affordable, portable and simplistic diagnostic sensors to improve access to care","volume":"22","author":"Hafezi","year":"2022","journal-title":"Sensors (Basel, Switzerland)"},{"issue":"2","key":"10.1016\/j.clae.2026.102830_bb0140","doi-asserted-by":"crossref","DOI":"10.3390\/jcm14020460","article-title":"Strategies for early keratoconus diagnosis: a narrative review of evaluating affordable and effective detection techniques","volume":"14","author":"Gideon Abou Said","year":"2025","journal-title":"J Clin Med"},{"key":"10.1016\/j.clae.2026.102830_bb0145","doi-asserted-by":"crossref","first-page":"71","DOI":"10.2147\/OPTO.S446599","article-title":"Barriers to the diagnosis and management of keratoconus among optometrists in Kenya","author":"Rashid","year":"2024","journal-title":"Clin Optom"},{"issue":"9","key":"10.1016\/j.clae.2026.102830_bb0150","doi-asserted-by":"crossref","first-page":"1522","DOI":"10.1016\/j.jcrs.2007.05.029","article-title":"Effects of misalignment during corneal topography","volume":"33","author":"Hick","year":"2007","journal-title":"J Cataract Refract Surg"},{"issue":"11","key":"10.1016\/j.clae.2026.102830_bb0155","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0139541","article-title":"Effect of misalignment between successive corneal videokeratography maps on the repeatability of topography data","volume":"10","author":"Bao","year":"2015","journal-title":"PloS One"},{"issue":"10","key":"10.1016\/j.clae.2026.102830_bb0160","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1016\/S0161-6420(94)31109-2","article-title":"The effect of poor fixation on computer-assisted topographic corneal analysis: pseudokeratoconus","volume":"101","author":"Hubbe","year":"1994","journal-title":"Ophthalmology"},{"issue":"17","key":"10.1016\/j.clae.2026.102830_bb0165","doi-asserted-by":"crossref","first-page":"5411","DOI":"10.1364\/AO.54.005411","article-title":"Surface shape evaluation with a corneal topographer based on a conical null-screen with a novel radial point distribution","volume":"54","author":"Campos-Garc\u00eda","year":"2015","journal-title":"Appl Optics"},{"issue":"7","key":"10.1016\/j.clae.2026.102830_bb0170","doi-asserted-by":"crossref","first-page":"283","DOI":"10.1097\/ICL.0000000000001090","article-title":"Morphological features among Gaussian, Sagittal, and Tangential curvature maps in normal and keratoconus eyes using anterior segment optical coherence tomography","volume":"50","author":"Henriquez","year":"2024","journal-title":"Eye Contact Lens"},{"issue":"1","key":"10.1016\/j.clae.2026.102830_bb0175","doi-asserted-by":"crossref","first-page":"14","DOI":"10.1111\/j.1442-9071.2008.01821.x","article-title":"An introduction to understanding elevation-based topography: how elevation data are displayed \u2013 a review","volume":"37","author":"Belin","year":"2009","journal-title":"Clin Exp Ophthalmol"},{"issue":"4","key":"10.1016\/j.clae.2026.102830_bb0180","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1364\/JOSAA.19.000657","article-title":"Videokeratoscope\u2013line-of-sight misalignment and its effect on measurements of corneal and internal ocular aberrations","volume":"19","author":"Salmon","year":"2002","journal-title":"J Opt Soc Am A"},{"issue":"12","key":"10.1016\/j.clae.2026.102830_bb0185","doi-asserted-by":"crossref","DOI":"10.1364\/BOE.2.003232","article-title":"Corneal topography from spectral optical coherence tomography (sOCT)","volume":"2","author":"Ortiz","year":"2011","journal-title":"Biomed Opt Express"},{"issue":"10","key":"10.1016\/j.clae.2026.102830_bb0190","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1016\/S0886-3350(99)00195-9","article-title":"KISA% index: a quantitative videokeratography algorithm embodying minimal topographic criteria for diagnosing keratoconus","volume":"25","author":"Rabinowitz","year":"1999","journal-title":"J Cataract Refract Surg"},{"issue":"2","key":"10.1016\/j.clae.2026.102830_bb0195","doi-asserted-by":"crossref","first-page":"136","DOI":"10.1016\/j.zemedi.2015.11.001","article-title":"Detection of ectatic corneal diseases based on pentacam","volume":"26","author":"Lopes","year":"2016","journal-title":"Z Med Phys"},{"issue":"6","key":"10.1016\/j.clae.2026.102830_bb0200","doi-asserted-by":"crossref","first-page":"1381","DOI":"10.1364\/AO.449875","article-title":"Smartphone-based corneal topography with null-screens","volume":"61","author":"Huerta-Carranza","year":"2022","journal-title":"Appl Optics"},{"issue":"7","key":"10.1016\/j.clae.2026.102830_bb0205","doi-asserted-by":"crossref","first-page":"2199","DOI":"10.1007\/s00417-024-06426-9","article-title":"Evaluation of a new portable corneal topography system for self-measurement using smartphones: a pilot study","volume":"262","author":"Kobashi","year":"2024","journal-title":"Graefes Arch Clin Exp Ophthalmol"},{"issue":"1","key":"10.1016\/j.clae.2026.102830_bb0210","doi-asserted-by":"crossref","first-page":"26732","DOI":"10.1038\/s41598-024-77699-7","article-title":"Correlation of angle kappa and angle alpha on visual outcomes in eyes implanted with three types of multifocal intraocular lenses","volume":"14","author":"Ang","year":"2024","journal-title":"Sci Rep"}],"container-title":["Contact Lens and Anterior Eye"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048426002262?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1367048426002262?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T02:47:37Z","timestamp":1789699657000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1367048426002262"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,10]]},"references-count":42,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2026,10]]}},"alternative-id":["S1367048426002262"],"URL":"https:\/\/doi.org\/10.1016\/j.clae.2026.102830","relation":{},"ISSN":["1367-0484"],"issn-type":[{"value":"1367-0484","type":"print"}],"subject":[],"published":{"date-parts":[[2026,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"OcuTOP: a novel handheld corneal topography device with misalignment correction","name":"articletitle","label":"Article Title"},{"value":"Contact Lens and Anterior Eye","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clae.2026.102830","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 British Contact Lens Association. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"102830"}}