{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,4,3]],"date-time":"2026-04-03T11:18:35Z","timestamp":1775215115995,"version":"3.50.1"},"reference-count":16,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2023,5,1]],"date-time":"2023-05-01T00:00:00Z","timestamp":1682899200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2023,5,1]],"date-time":"2023-05-01T00:00:00Z","timestamp":1682899200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Biochemistry"],"published-print":{"date-parts":[[2023,5]]},"DOI":"10.1016\/j.clinbiochem.2022.08.008","type":"journal-article","created":{"date-parts":[[2022,8,23]],"date-time":"2022-08-23T02:02:43Z","timestamp":1661220163000},"page":"86-91","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":5,"special_numbering":"C","title":["Not T too! False elevations in high-sensitivity cardiac troponin T (hs-TnT) following specimen transport"],"prefix":"10.1016","volume":"115","author":[{"given":"Heather A.","family":"Paul","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Qingli","family":"Chi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jessica L.","family":"Gifford","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Isolde","family":"Seiden-Long","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.clinbiochem.2022.08.008_b0005","doi-asserted-by":"crossref","unstructured":"K. Thygesen, J.S. Alpert, A.S. Jaffe, B.R. Chaitman, J.J. Bax, D.A. Morrow, H.D. White, S. Corbett, M. Chettibi, H. Hayrapetyan, F.X. Roithinger, F. Aliyev, V. Sujayeva, M.J. Claeys, E. Smaji\u0107, P. Kala, K.K. Iversen, E. El Hefny, T. Marandi, P. Porela, S. Antov, M. Gilard, S. Blankenberg, P. Davlouros, T. Gudnason, R. Alcalai, F. Colivicchi, S. Elezi, G. Baitova, I. Zakke, O. Gustiene, J. Beissel, P. Dingli, A. Grosu, P. Damman, V. Juliebo, J. Legutko, J. Morais, G. Tatu-Chitoiu, A. Yakovlev, M. Zavatta, M. Nedeljkovic, P. Radsel, A. Sionis, T. Jemberg, C. M\u00fcller, L. Abid, A. Abaci, A. Parkhomenko, Fourth Universal Definition of Myocardial Infarction (2018), Circulation. 138 (2018) e618\u2013e651. doi:10.1161\/CIR.0000000000000617.","DOI":"10.1093\/eurheartj\/ehy462"},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0010","first-page":"98","article-title":"Contemporary Emergency Department Management of Patients with Chest Pain: A Concise Review and Guide for the High-Sensitivity Troponin Era","volume":"34","author":"Andruchow","year":"2018","journal-title":"Can. J. Cardiol."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0015","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.ijcard.2004.03.008","article-title":"False-positive troponin I measured with the Abbott AxSYM attributed to fibrin interference","volume":"101","author":"Kazmierczak","year":"2005","journal-title":"Int. J. Cardiol."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0020","doi-asserted-by":"crossref","first-page":"1789","DOI":"10.1515\/CCLM.2008.345","article-title":"Prevention of preanalytical false-positive increases of cardiac troponin I on the Unicel\u00ae DxI 800 analyzer","volume":"46","author":"Hejl","year":"2008","journal-title":"Clin. Chem. Lab. Med."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0025","doi-asserted-by":"crossref","unstructured":"D. Beh\u00fa Lov\u00e1, V. Bzd\u00fa Ch, D. Hole\u0161ov\u00e1, A. Vasilenkov\u00e1, J. Ponec, Comparison of Single and Repeat Centrifugation of Blood Specimens Collected in BD Evacuated Blood Collection Tubes Containing a Clot Activator for Cardiac Troponin I Assay on the ACCESS Analyzer, n.d. https:\/\/academic.oup.com\/clinchem\/article\/46\/11\/1869\/5641210.","DOI":"10.1093\/clinchem\/46.11.1869"},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0030","doi-asserted-by":"crossref","first-page":"710","DOI":"10.1373\/clinchem.2010.159830","article-title":"Outliers as a cause of false cardiac troponin results: Investigating the robustness of 4 contemporary assays","volume":"57","author":"Pretorius","year":"2011","journal-title":"Clin. Chem."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0035","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1515\/CCLM.2011.163","article-title":"Evidence on the cause of false positive troponin i results with the Beckman AccuTnI method","volume":"49","author":"Dimeski","year":"2011","journal-title":"Clin. Chem. Lab. Med."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0040","doi-asserted-by":"crossref","first-page":"1201","DOI":"10.1515\/cclm-2020-1564","article-title":"The underestimated issue of non-reproducible cardiac troponin I and T results: Case series and systematic review of the literature","volume":"59","author":"Favresse","year":"2021","journal-title":"Clin. Chem. Lab. Med."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0045","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.cca.2013.09.004","article-title":"Interference from heterophilic antibodies in troponin testing. Case report and systematic review of the literature","volume":"426","author":"Lippi","year":"2013","journal-title":"Clin. Chim. Acta."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0050","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1016\/j.clinbiochem.2017.05.015","article-title":"The BD Barricor blood collection tube is an acceptable and robust alternative to the PST for use with the Beckman AccuTnI+3 assay","volume":"50","author":"F\u00fcz\u00e9ry","year":"2017","journal-title":"Clin. Biochem."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0055","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1016\/j.clinbiochem.2012.04.014","article-title":"BD rapid serum tubes reduce false positive plasma troponin T results on the Roche Cobas e411 analyzer","volume":"45","author":"Koch","year":"2012","journal-title":"Clin. Biochem."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0060","doi-asserted-by":"crossref","first-page":"1972","DOI":"10.1515\/cclm-2021-0626","article-title":"Identification of macrotroponin T: Findings from a case report and non-reproducible troponin T results","volume":"59","author":"Lam","year":"2021","journal-title":"Clin. Chem. Lab. Med."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0065","doi-asserted-by":"crossref","unstructured":"Z. Akhtar, J. Dargan, D. Gaze, S. Firoozi, P. Collinson, N. Shanmugam, False-positive troponin elevation due to an immunoglobulin-G-cardiac troponin T complex: A case report, Eur. Hear. J. - Case Reports. 4 (2020). doi:10.1093\/ehjcr\/ytaa082.","DOI":"10.1093\/ehjcr\/ytaa082"},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0070","doi-asserted-by":"crossref","first-page":"1819","DOI":"10.1016\/j.jacc.2011.08.026","article-title":"Diseased skeletal muscle: A noncardiac source of increased circulating concentrations of cardiac troponin T","volume":"58","author":"Jaffe","year":"2011","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.clinbiochem.2022.08.008_b0075","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1016\/j.jacc.2018.01.070","article-title":"Elevated Cardiac Troponin T in Patients With Skeletal Myopathies","volume":"71","author":"Schmid","year":"2018","journal-title":"J. Am. Coll. Cardiol."},{"issue":"2016","key":"10.1016\/j.clinbiochem.2022.08.008_b0080","first-page":"267","article-title":"ESC Guidelines for the management of acute coronary syndromes in patients presenting without persistent st-segment elevation: Task force for the management of acute coronary syndromes in patients presenting without persistent ST-segment elevation of","volume":"37","author":"Roffi","year":"2015","journal-title":"Eur. Heart J."}],"container-title":["Clinical Biochemistry"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009912022001977?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009912022001977?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,14]],"date-time":"2025-09-14T16:00:26Z","timestamp":1757865626000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0009912022001977"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2023,5]]},"references-count":16,"alternative-id":["S0009912022001977"],"URL":"https:\/\/doi.org\/10.1016\/j.clinbiochem.2022.08.008","relation":{},"ISSN":["0009-9120"],"issn-type":[{"value":"0009-9120","type":"print"}],"subject":[],"published":{"date-parts":[[2023,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Not T too! False elevations in high-sensitivity cardiac troponin T (hs-TnT) following specimen transport","name":"articletitle","label":"Article Title"},{"value":"Clinical Biochemistry","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clinbiochem.2022.08.008","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}