{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,23]],"date-time":"2026-01-23T11:00:09Z","timestamp":1769166009077,"version":"3.49.0"},"reference-count":50,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2008,11,1]],"date-time":"2008-11-01T00:00:00Z","timestamp":1225497600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Biomechanics"],"published-print":{"date-parts":[[2008,11]]},"DOI":"10.1016\/j.clinbiomech.2008.06.001","type":"journal-article","created":{"date-parts":[[2008,7,19]],"date-time":"2008-07-19T08:46:55Z","timestamp":1216457215000},"page":"1148-1157","source":"Crossref","is-referenced-by-count":54,"title":["The effect of bearing congruency, thickness and alignment on the stresses in unicompartmental knee replacements"],"prefix":"10.1016","volume":"23","author":[{"given":"D.J.","family":"Simpson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.","family":"Gray","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.","family":"D\u2019Lima","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"D.W.","family":"Murray","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.S.","family":"Gill","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"3","key":"10.1016\/j.clinbiomech.2008.06.001_bib1","doi-asserted-by":"crossref","first-page":"177","DOI":"10.1016\/j.knee.2004.03.004","article-title":"Polyethylene wear in a non-congruous unicompartmental knee replacement: a retrieval analysis","volume":"11","author":"Ashraf","year":"2004","journal-title":"Knee"},{"issue":"7","key":"10.1016\/j.clinbiomech.2008.06.001_bib2","doi-asserted-by":"crossref","first-page":"1041","DOI":"10.2106\/00004623-198668070-00010","article-title":"The effect of conformity, thickness, and material on stresses in ultra-high molecular weight components for total joint replacement","volume":"68","author":"Bartel","year":"1986","journal-title":"J. Bone Joint Surg. Am."},{"issue":"317","key":"10.1016\/j.clinbiomech.2008.06.001_bib3","first-page":"76","article-title":"Stresses in polyethylene components of contemporary total knee replacements","author":"Bartel","year":"1995","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"299","key":"10.1016\/j.clinbiomech.2008.06.001_bib4","first-page":"18","article-title":"Polyethylene wear in unicompartmental knee arthroplasty","author":"Bartley","year":"1994","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"5","key":"10.1016\/j.clinbiomech.2008.06.001_bib5","doi-asserted-by":"crossref","first-page":"999","DOI":"10.2106\/JBJS.C.00568","article-title":"Results of unicompartmental knee arthroplasty at a minimum of ten years of follow-up","volume":"87","author":"Berger","year":"2005","journal-title":"J. Bone Joint Surg. Am."},{"issue":"392","key":"10.1016\/j.clinbiomech.2008.06.001_bib6","doi-asserted-by":"crossref","first-page":"221","DOI":"10.1097\/00003086-200111000-00027","article-title":"Mobile-bearing knee replacement: clinical results: a review of the literature","author":"Callaghan","year":"2001","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"4","key":"10.1016\/j.clinbiomech.2008.06.001_bib7","doi-asserted-by":"crossref","first-page":"424","DOI":"10.1002\/jor.1100030405","article-title":"Stress analysis of a condylar knee tibial component: influence of metaphyseal shell properties and cement injection depth","volume":"3","author":"Cheal","year":"1985","journal-title":"J. Orthop. Res."},{"issue":"6","key":"10.1016\/j.clinbiomech.2008.06.001_bib8","first-page":"709","article-title":"Does a minimally invasive approach affect positioning of components in unicompartmental knee arthroplasty? Early results with survivorship analysis","volume":"72","author":"Cool","year":"2006","journal-title":"Acta Orthop. Belg."},{"issue":"392","key":"10.1016\/j.clinbiomech.2008.06.001_bib9","doi-asserted-by":"crossref","first-page":"272","DOI":"10.1097\/00003086-200111000-00035","article-title":"Unicompartmental knee arthroplasty: long-term results","author":"Deshmukh","year":"2001","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"1","key":"10.1016\/j.clinbiomech.2008.06.001_bib10","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1302\/0301-620X.74B1.1732274","article-title":"Polyethylene wear of metal-backed tibial components in total and unicompartmental knee prostheses","volume":"74","author":"Engh","year":"1992","journal-title":"J. Bone Joint Surg. Br."},{"issue":"1","key":"10.1016\/j.clinbiomech.2008.06.001_bib11","doi-asserted-by":"crossref","first-page":"80","DOI":"10.1002\/jor.1100160114","article-title":"Residual stresses in ultra-high molecular weight polyethylene loaded cyclically by a rigid moving indenter in nonconforming geometries","volume":"16","author":"Estupinan","year":"1998","journal-title":"J. Orthop. Res."},{"issue":"416","key":"10.1016\/j.clinbiomech.2008.06.001_bib12","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1097\/01.blo.0000093004.90435.d1","article-title":"Analysis of unicompartmental knee arthroplasty in a community-based implant registry","author":"Gioe","year":"2003","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"5","key":"10.1016\/j.clinbiomech.2008.06.001_bib13","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/j.knee.2004.06.006","article-title":"Fixed or mobile bearing unicompartmental knee replacement? A comparative cohort study","volume":"11","author":"Gleeson","year":"2004","journal-title":"Knee"},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib14","series-title":"Unicompartmental Arthroplasty with the Oxford Knee","author":"Goodfellow","year":"2006"},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib15","unstructured":"Gray, H.A., 2007. Finite Element Analysis of the Human Tibia. D. Phil Thesis."},{"issue":"3","key":"10.1016\/j.clinbiomech.2008.06.001_bib16","doi-asserted-by":"crossref","first-page":"315","DOI":"10.1243\/09544119JEIM119","article-title":"Experimental validation of a finite element model of a composite tibia","volume":"221","author":"Gray","year":"2007","journal-title":"Proc. Inst. Mech. Eng. [H]"},{"issue":"423","key":"10.1016\/j.clinbiomech.2008.06.001_bib17","doi-asserted-by":"crossref","first-page":"161","DOI":"10.1097\/01.blo.0000128285.90459.12","article-title":"Alignment influences wear in the knee after medial unicompartmental arthroplasty","author":"Hernigou","year":"2004","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"5","key":"10.1016\/j.clinbiomech.2008.06.001_bib18","doi-asserted-by":"crossref","first-page":"423","DOI":"10.1016\/S0021-9290(98)00028-1","article-title":"Dynamic knee loads during gait predict proximal tibial bone distribution","volume":"31","author":"Hurwitz","year":"1998","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib19","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1016\/S0021-9290(01)00244-5","article-title":"The effects of tibial component inclination on bone stress after unicompartmental knee arthroplasty","volume":"35","author":"Iesaka","year":"2001","journal-title":"J. Biomech."},{"issue":"2","key":"10.1016\/j.clinbiomech.2008.06.001_bib20","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.knee.2006.11.012","article-title":"The survivorship and results of total knee replacements converted from unicompartmental knee replacements","volume":"14","author":"Johnson","year":"2007","journal-title":"Knee"},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib21","series-title":"Contact Mechanics","author":"Johnson","year":"1987"},{"issue":"3","key":"10.1016\/j.clinbiomech.2008.06.001_bib22","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1080\/17453670710013942","article-title":"Quantification of polyethylene degradation in mobile bearing knees: a retrieval analysis of the Anterior\u2013Posterior-Glide (APG) and Rotating Platform (RP) Low Contact Stress (LCS) knee","volume":"78","author":"Kop","year":"2007","journal-title":"Acta Orthop."},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib23","doi-asserted-by":"crossref","unstructured":"Kurtz, S.M., Jewett, C.W., Moalli, J.E., Edidin, A.A., 1997. An elastic\u2013plastic material model for the true stress\u2013strain behavior of ultra-high molecular weight polyethylene in tension and compression. In: Advances in Bioengineering BED34. American Society of Mechanical Engineers, New York.","DOI":"10.1115\/IMECE1997-0353"},{"issue":"5","key":"10.1016\/j.clinbiomech.2008.06.001_bib24","doi-asserted-by":"crossref","first-page":"755","DOI":"10.1002\/jor.1100140512","article-title":"Exponential model for the tensile true stress\u2013strain behavior of as-irradiated and oxidatively degraded ultra high molecular weight polyethylene","volume":"14","author":"Kurtz","year":"1996","journal-title":"J. Orthop. Res."},{"issue":"375","key":"10.1016\/j.clinbiomech.2008.06.001_bib25","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1097\/00003086-200006000-00036","article-title":"The effects of conformity and load in total knee replacement","author":"Kuster","year":"2000","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"2","key":"10.1016\/j.clinbiomech.2008.06.001_bib26","doi-asserted-by":"crossref","first-page":"155","DOI":"10.1002\/(SICI)1097-4636(199722)38:2<155::AID-JBM10>3.0.CO;2-C","article-title":"Properties of acrylic bone cement: state of the art review","volume":"38","author":"Lewis","year":"1997","journal-title":"J. Biomed. Mater. Res."},{"issue":"392","key":"10.1016\/j.clinbiomech.2008.06.001_bib27","doi-asserted-by":"crossref","first-page":"279","DOI":"10.1097\/00003086-200111000-00036","article-title":"Revision of failed unicompartmental knee arthroplasty","author":"McAuley","year":"2001","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"7","key":"10.1016\/j.clinbiomech.2008.06.001_bib28","doi-asserted-by":"crossref","first-page":"873","DOI":"10.1016\/S0021-9290(01)00035-5","article-title":"Duration and frequency of every day activities in total hip patients","volume":"34","author":"Morlock","year":"2001","journal-title":"J. Biomech."},{"issue":"Suppl. 4","key":"10.1016\/j.clinbiomech.2008.06.001_bib29","doi-asserted-by":"crossref","first-page":"111","DOI":"10.2106\/00004623-200300004-00014","article-title":"Effects of walking gait on ultra-high molecular weight polyethylene damage in unicompartmental knee systems. A finite element study","volume":"85-A","author":"Morra","year":"2003","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib30","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1016\/0022-5096(67)90030-0","article-title":"On the description of anisotropic work hardening","volume":"15","author":"Mroz","year":"1967","journal-title":"J. Mech. Phys. Solids"},{"issue":"17","key":"10.1016\/j.clinbiomech.2008.06.001_bib31","doi-asserted-by":"crossref","first-page":"2933","DOI":"10.1016\/S0142-9612(03)00055-3","article-title":"Shrinkage stresses in bone cement","volume":"24","author":"Orr","year":"2003","journal-title":"Biomaterials"},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib32","doi-asserted-by":"crossref","unstructured":"Palmer, S.H., Morrison, P.J., Ross, A.C., 1998. Early catastrophic tibial component wear after unicompartmental knee arthroplasty. Clin. Orthop. Relat. Res. (350), 143\u2013148.","DOI":"10.1097\/00003086-199805000-00020"},{"issue":"2","key":"10.1016\/j.clinbiomech.2008.06.001_bib33","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1016\/j.knee.2007.11.008","article-title":"Combined anterior cruciate reconstruction and Oxford unicompartmental knee arthroplasty: in vivo kinematics","volume":"15","author":"Pandit","year":"2008","journal-title":"The Knee"},{"issue":"7","key":"10.1016\/j.clinbiomech.2008.06.001_bib34","doi-asserted-by":"crossref","first-page":"940","DOI":"10.1302\/0301-620X.87B7.15716","article-title":"Influence of surface geometry and the cam-post mechanism on the kinematics of total knee replacement","volume":"87","author":"Pandit","year":"2005","journal-title":"J. Bone Joint Surg. Br."},{"issue":"11","key":"10.1016\/j.clinbiomech.2008.06.001_bib35","doi-asserted-by":"crossref","first-page":"1493","DOI":"10.1302\/0301-620X.87B11.16325","article-title":"Ten-year in vivo wear measurement of a fully congruent mobile bearing unicompartmental knee arthroplasty","volume":"87","author":"Price","year":"2005","journal-title":"J. Bone Joint Surg. Br."},{"issue":"6","key":"10.1016\/j.clinbiomech.2008.06.001_bib36","doi-asserted-by":"crossref","first-page":"976","DOI":"10.1302\/0301-620X.80B6.8176","article-title":"Wear of congruent meniscal bearings in unicompartmental knee arthroplasty: a retrieval study of 16 specimens","volume":"80","author":"Psychoyios","year":"1998","journal-title":"J. Bone Joint Surg. Br."},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib37","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/S0021-9290(01)00172-5","article-title":"Flat medial-lateral conformity in total knee replacements does not minimise contact stresses","volume":"35","author":"Rawlinson","year":"2001","journal-title":"J. Biomech."},{"issue":"5","key":"10.1016\/j.clinbiomech.2008.06.001_bib38","doi-asserted-by":"crossref","first-page":"347","DOI":"10.1016\/1350-4533(95)97314-F","article-title":"Relations of mechanical properties to density and CT numbers in human bone","volume":"17","author":"Rho","year":"1995","journal-title":"Med. Eng. Phys."},{"issue":"333","key":"10.1016\/j.clinbiomech.2008.06.001_bib39","first-page":"87","article-title":"Fatigue strength of polyethylene after sterilization by gamma irradiation or ethylene oxide","author":"Ries","year":"1996","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"3","key":"10.1016\/j.clinbiomech.2008.06.001_bib40","doi-asserted-by":"crossref","first-page":"255","DOI":"10.1016\/0021-9290(94)90002-7","article-title":"Optimization of the bearing surface geometry of total knees","volume":"27","author":"Sathasivam","year":"1994","journal-title":"J. Biomech."},{"issue":"3","key":"10.1016\/j.clinbiomech.2008.06.001_bib41","doi-asserted-by":"crossref","first-page":"549","DOI":"10.1016\/j.orthres.2004.06.007","article-title":"Three-dimensional finite element analysis of unicompartmental knee arthroplasty \u2013 the influence of tibial component inclination","volume":"23","author":"Sawatari","year":"2005","journal-title":"J. Orthop. Res."},{"issue":"1","key":"10.1016\/j.clinbiomech.2008.06.001_bib42","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1016\/0043-1648(74)90149-5","article-title":"The friction and wear behavior of irradiated very high molecular weight polyethylene","volume":"30","author":"Shen","year":"1974","journal-title":"Wear"},{"issue":"1","key":"10.1016\/j.clinbiomech.2008.06.001_bib43","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/0045-7949(92)90540-G","article-title":"An augmented lagrangian treatment of contact problems involving friction","volume":"42","author":"Simo","year":"1992","journal-title":"Comput. Struct."},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib44","doi-asserted-by":"crossref","first-page":"131","DOI":"10.2106\/00004623-200409001-00004","article-title":"Unicompartmental knee arthroplasty in patients sixty years of age or younger","author":"Swienckowski","year":"2004","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib45","doi-asserted-by":"crossref","first-page":"S31","DOI":"10.1016\/j.jbiomech.2007.02.016","article-title":"How effective are added constraints in improving TKR kinematics?","volume":"40","author":"van Duren","year":"2007","journal-title":"J. Biomech."},{"issue":"5","key":"10.1016\/j.clinbiomech.2008.06.001_bib46","doi-asserted-by":"crossref","first-page":"379","DOI":"10.1016\/S1350-4533(00)00057-6","article-title":"A comparative study on different methods of automatic mesh generation of human femurs. Medical Engineering and Physics 20 (1998): 1\u201310","volume":"22","author":"Viceconti","year":"2000","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib47","series-title":"Strain Gauge Analysis of Hard Tissue: Factors Influencing Measurements","author":"Viceconti","year":"1992"},{"issue":"4","key":"10.1016\/j.clinbiomech.2008.06.001_bib48","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1243\/EMED_JOUR_1988_017_041_02","article-title":"Bearing surface design in total knee replacement","volume":"17","author":"Walker","year":"1988","journal-title":"Eng Med"},{"key":"10.1016\/j.clinbiomech.2008.06.001_bib49","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1097\/01.blo.0000187811.48717.9d","article-title":"Polyethylene in knee arthroplasty: what is the future?","volume":"440","author":"Wright","year":"2005","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"5","key":"10.1016\/j.clinbiomech.2008.06.001_bib50","doi-asserted-by":"crossref","first-page":"593","DOI":"10.1002\/jor.20362","article-title":"In vivo medial and lateral tibial loads during dynamic and high flexion activities","volume":"25","author":"Zhao","year":"2007","journal-title":"J. Orthop. Res."}],"container-title":["Clinical Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003308002076?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003308002076?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2023,5,19]],"date-time":"2023-05-19T07:28:42Z","timestamp":1684481322000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0268003308002076"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2008,11]]},"references-count":50,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2008,11]]}},"alternative-id":["S0268003308002076"],"URL":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2008.06.001","relation":{},"ISSN":["0268-0033"],"issn-type":[{"value":"0268-0033","type":"print"}],"subject":[],"published":{"date-parts":[[2008,11]]}}}