{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,16]],"date-time":"2026-10-16T06:18:21Z","timestamp":1792131501897,"version":"4.4.0"},"reference-count":42,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2012,1,1]],"date-time":"2012-01-01T00:00:00Z","timestamp":1325376000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Clinical Biomechanics"],"published-print":{"date-parts":[[2012,1]]},"DOI":"10.1016\/j.clinbiomech.2011.07.006","type":"journal-article","created":{"date-parts":[[2011,12,21]],"date-time":"2011-12-21T13:24:29Z","timestamp":1324473869000},"page":"71-76","source":"Crossref","is-referenced-by-count":47,"title":["Biomechanical evaluation of bone-cement augmented Proximal Femoral Nail Antirotation blades in a polyurethane foam model with low density"],"prefix":"10.1016","volume":"27","author":[{"given":"A.","family":"Sermon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"V.","family":"Boner","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"K.","family":"Schwieger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Boger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Boonen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Broos","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"G.","family":"Richards","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Windolf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0005","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/S0020-1383(02)00008-6","article-title":"The AO\/ASIF proximal femoral nail (PFN) for the treatment of unstable trochanteric femoral fracture","volume":"33","author":"Al Yassari","year":"2002","journal-title":"Injury"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0010","series-title":"ASTM F 1839\u201301 Standard Specification for Rigid Polyurethane Foam for Use as a Standard Material for Testing Orthopaedic Devices and Instruments","author":"ASTM International","year":"2001"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0015","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1097\/00005131-200205000-00004","article-title":"A modified hip screw incorporating injected cement for the fixation of osteoporotic trochanteric fractures","volume":"16","author":"Augat","year":"2002","journal-title":"J. Orthop. Trauma"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0020","doi-asserted-by":"crossref","first-page":"438","DOI":"10.1097\/00005131-199310000-00006","article-title":"Healing complications after internal fixation of trochanteric hip fractures: the prognostic value of osteoporosis","volume":"7","author":"Barrios","year":"1993","journal-title":"J. Orthop. Trauma"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0025","doi-asserted-by":"crossref","first-page":"1094","DOI":"10.2106\/00004623-198567070-00014","article-title":"The effect of adjunctive methylmethacrylate on failures of fixation and function in patients with intertrochanteric fractures and osteoporosis","volume":"67","author":"Bartucci","year":"1985","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0030","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1302\/0301-620X.79B6.7949","article-title":"Awareness of tip\u2013apex distance reduces failure of fixation of trochanteric fractures of the hip","volume":"79","author":"Baumgaertner","year":"1997","journal-title":"J. Bone Joint Surg. Br."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0035","doi-asserted-by":"crossref","first-page":"1058","DOI":"10.2106\/00004623-199507000-00012","article-title":"The value of the tip\u2013apex distance in predicting failure of fixation of peritrochanteric fractures of the hip","volume":"77","author":"Baumgaertner","year":"1995","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0040","doi-asserted-by":"crossref","first-page":"859","DOI":"10.1016\/S0021-9290(01)00040-9","article-title":"Hip contact forces and gait patterns from routine activities","volume":"34","author":"Bergmann","year":"2001","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0045","doi-asserted-by":"crossref","first-page":"84","DOI":"10.1007\/s002239900300","article-title":"Hip fracture-associated mortality reconsidered","volume":"61","author":"Block","year":"1997","journal-title":"Calcif. Tissue Int."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0050","unstructured":"Boger, A., Wheeler, K., (submitted for publication). A medium viscous acrylic cement enhances uniformity of cement filling and reduce leakage in cancellous bone augmentation. Spine."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0055","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1080\/00016470310013662","article-title":"The proximal femoral nail (PFN)\u2014a minimal invasive treatment of unstable proximal femoral fractures: a prospective study of 55 patients with a follow-up of 15months","volume":"74","author":"Boldin","year":"2003","journal-title":"Acta Orthop. Scand."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0060","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1002\/jbm.b.31353","article-title":"Temperature evaluation during PMMA screw augmentation in osteoporotic bone\u2014an in vitro study about the risk of thermal necrosis in human femoral heads","volume":"90","author":"Boner","year":"2009","journal-title":"J. Biomed. Mater. Res. B Appl. Biomater."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0065","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/s00198-003-1515-z","article-title":"Functional outcome and quality of life following hip fracture in elderly women: a prospective controlled study","volume":"15","author":"Boonen","year":"2004","journal-title":"Osteoporos. Int."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0070","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1016\/j.beem.2008.07.002","article-title":"Osteoporosis and osteoporotic fracture occurrence and prevention in the elderly: a geriatric perspective","volume":"22","author":"Boonen","year":"2008","journal-title":"Best Pract. Res. Clin. Endocrinol. Metab."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0080","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1359\/jbmr.061113","article-title":"Incidence and economic burden of osteoporosis-related fractures in the United States, 2005\u20132025","volume":"22","author":"Burge","year":"2007","journal-title":"J. Bone Miner. Res."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0085","doi-asserted-by":"crossref","first-page":"556","DOI":"10.1007\/s001980070075","article-title":"Risk of mortality following clinical fractures","volume":"11","author":"Cauley","year":"2000","journal-title":"Osteoporos. Int."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0090","doi-asserted-by":"crossref","first-page":"134","DOI":"10.1016\/0020-1383(89)90082-X","article-title":"Long-term results and complications of cement augmentation in the treatment of unstable trochanteric fractures","volume":"20","author":"Cheng","year":"1989","journal-title":"Injury"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0095","doi-asserted-by":"crossref","first-page":"1889","DOI":"10.1001\/jama.288.15.1889","article-title":"Clinical use of bone densitometry: scientific review","volume":"288","author":"Cummings","year":"2002","journal-title":"JAMA"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0100","doi-asserted-by":"crossref","first-page":"26","DOI":"10.1302\/0301-620X.72B1.2298790","article-title":"Intertrochanteric femoral fractures. Mechanical failure after internal fixation","volume":"72","author":"Davis","year":"1990","journal-title":"J. Bone Joint Surg. Br."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0105","doi-asserted-by":"crossref","first-page":"302","DOI":"10.1097\/00005131-200205000-00003","article-title":"The effect of augmentation with resorbable or conventional bone cement on the holding strength for femoral neck fracture devices","volume":"16","author":"Eriksson","year":"2002","journal-title":"J. Orthop. Trauma"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0110","doi-asserted-by":"crossref","first-page":"403","DOI":"10.1007\/s00264-006-0170-3","article-title":"Proximal femoral nail \u2014 an analysis of 100 cases of proximal femoral fractures with an average follow up of 1year","volume":"31","author":"Gadegone","year":"2007","journal-title":"Int. Orthop."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0115","doi-asserted-by":"crossref","first-page":"506","DOI":"10.1016\/j.clinbiomech.2004.01.014","article-title":"Femoroplasty-augmentation of mechanical properties in the osteoporotic proximal femur: a biomechanical investigation of PMMA reinforcement in cadaver bones","volume":"19","author":"Heini","year":"2004","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0120","doi-asserted-by":"crossref","first-page":"265","DOI":"10.1503\/cmaj.081720","article-title":"Relation between fractures and mortality: results from the Canadian Multicentre Osteoporosis Study","volume":"181","author":"Ioannidis","year":"2009","journal-title":"CMAJ"},{"issue":"5","key":"10.1016\/j.clinbiomech.2011.07.006_bb0125","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1055\/s-2000-10179","article-title":"Schraubenhalt-Verst\u00e4rkung im Femurkopf durch Zementapplikation via Implantat - eine biomechanische Studie","volume":"138","author":"Kramer","year":"2000","journal-title":"Z. Orthop. Ihre Grenzgeb."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0130","first-page":"272","article-title":"The relationship between bone density, mineral content, and mechanical strength in the femoral neck","author":"Leichter","year":"1982","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0135","doi-asserted-by":"crossref","first-page":"428","DOI":"10.1016\/j.injury.2008.10.014","article-title":"The AO\/ASIF proximal femoral nail antirotation (PFNA): a new design for the treatment of unstable proximal femoral fractures","volume":"40","author":"Mereddy","year":"2009","journal-title":"Injury"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0140","doi-asserted-by":"crossref","first-page":"577","DOI":"10.1097\/00005131-199711000-00006","article-title":"Hip screw augmentation with an in situ-setting calcium phosphate cement: an in vitro biomechanical analysis","volume":"11","author":"Moore","year":"1997","journal-title":"J. Orthop. Trauma"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0145","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1115\/1.2401178","article-title":"The biomechanics of human femurs in axial and torsional loading: comparison of finite element analysis, human cadaveric femurs, and synthetic femurs","volume":"129","author":"Papini","year":"2007","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0150","doi-asserted-by":"crossref","DOI":"10.1097\/BRS.0b013e318205e3af","article-title":"Biomechanical evaluation of a novel fenestrated pedicle screw augmented with bone cement in osteoporotic spines","author":"Par\u00e9","year":"2011","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0155","doi-asserted-by":"crossref","first-page":"994","DOI":"10.1016\/j.injury.2003.10.028","article-title":"Prediction of fixation failure after sliding hip screw fixation","volume":"35","author":"Pervez","year":"2004","journal-title":"Injury"},{"issue":"34","key":"10.1016\/j.clinbiomech.2011.07.006_bb0160","doi-asserted-by":"crossref","first-page":"2619","DOI":"10.1097\/BRS.0b013e3181b61d10","article-title":"Vertebroplasty with high viscosity polymethylmethacrylate cement facilitates vertebral body restoration in vitro","volume":"24","author":"R\u00fcger","year":"2009","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0165","doi-asserted-by":"crossref","first-page":"86","DOI":"10.1302\/0301-620X.86B1.14455","article-title":"Treatment of unstable trochanteric fractures. Randomised comparison of the gamma nail and the proximal femoral nail","volume":"86","author":"Schipper","year":"2004","journal-title":"J. Bone Joint Surg. Br."},{"issue":"6","key":"10.1016\/j.clinbiomech.2011.07.006_bb0170","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1016\/j.bone.2009.07.086","article-title":"Direct healthcare costs of hip, vertebral, and non-hip, non-vertebral fractures","volume":"45","author":"Shi","year":"2009","journal-title":"Bone"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0175","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1016\/S0020-1383(99)00091-1","article-title":"The AO\/ASIF-proximal femoral nail (PFN): a new device for the treatment of unstable proximal femoral fractures","volume":"30","author":"Simmermacher","year":"1999","journal-title":"Injury"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0180","doi-asserted-by":"crossref","first-page":"361","DOI":"10.1097\/00005131-200407000-00006","article-title":"A laboratory model to evaluate cutout resistance of implants for pertrochanteric fracture fixation","volume":"18","author":"Sommers","year":"2004","journal-title":"J. Orthop. Trauma"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0190","doi-asserted-by":"crossref","first-page":"433","DOI":"10.1002\/jor.1100050316","article-title":"Torsion and bending analysis of internal fixation techniques for femoral neck fractures: the role of implant design and bone density","volume":"5","author":"Swiontkowski","year":"1987","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0195","doi-asserted-by":"crossref","first-page":"125","DOI":"10.1002\/jab.770060207","article-title":"Characterization of three formulations of a synthetic foam as models for a range of human cancellous bone types","volume":"6","author":"Szivek","year":"1995","journal-title":"J. Appl. Biomater."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0200","doi-asserted-by":"crossref","first-page":"34","DOI":"10.1097\/00005131-200401000-00007","article-title":"Prevention of hip lag screw cut-out by cement augmentation: description of a new technique and preliminary clinical results","volume":"18","author":"Szpalski","year":"2004","journal-title":"J. Orthop. Trauma"},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0205","first-page":"276","article-title":"Treatment of trochanteric fractures with the PFNA (proximal femoral nail antirotation) nail system \u2014 report of early results","volume":"66","author":"Takigami","year":"2008","journal-title":"Bull. NYU Hosp. Jt. Dis."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0210","doi-asserted-by":"crossref","first-page":"2230","DOI":"10.1002\/jor.20299","article-title":"Biomechanical evaluation of a new augmentation method for enhanced screw fixation in osteoporotic proximal femoral fractures","volume":"24","author":"von der Linden","year":"2006","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0215","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1016\/j.clinbiomech.2008.07.004","article-title":"Is a helical shaped implant a superior alternative to the Dynamic Hip Screw for unstable femoral neck fractures? A biomechanical investigation","volume":"24","author":"Windolf","year":"2009","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2011.07.006_bb0220","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.clinbiomech.2008.09.005","article-title":"Quantification of cancellous bone-compaction due to DHS Blade insertion and influence upon cut-out resistance","volume":"24","author":"Windolf","year":"2009","journal-title":"Clin. Biomech."}],"container-title":["Clinical Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003311001872?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003311001872?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,6,21]],"date-time":"2019-06-21T01:27:08Z","timestamp":1561080428000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0268003311001872"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2012,1]]},"references-count":42,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2012,1]]}},"alternative-id":["S0268003311001872"],"URL":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2011.07.006","relation":{},"ISSN":["0268-0033"],"issn-type":[{"value":"0268-0033","type":"print"}],"subject":[],"published":{"date-parts":[[2012,1]]}}}