{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,24]],"date-time":"2026-01-24T00:19:19Z","timestamp":1769213959958,"version":"3.49.0"},"reference-count":60,"publisher":"Elsevier BV","issue":"10","license":[{"start":{"date-parts":[[2015,12,1]],"date-time":"2015-12-01T00:00:00Z","timestamp":1448928000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"name":"NRF","award":["NRF-2014M3C1B1033319"],"award-info":[{"award-number":["NRF-2014M3C1B1033319"]}]}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","clinbiomech.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Biomechanics"],"published-print":{"date-parts":[[2015,12]]},"DOI":"10.1016\/j.clinbiomech.2015.08.009","type":"journal-article","created":{"date-parts":[[2015,8,21]],"date-time":"2015-08-21T01:22:44Z","timestamp":1440120164000},"page":"1162-1169","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":38,"title":["Biomechanical effects of fusion levels on the risk of proximal junctional failure and kyphosis in lumbar spinal fusion surgery"],"prefix":"10.1016","volume":"30","author":[{"given":"Won Man","family":"Park","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Dae Kyung","family":"Choi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Kyungsoo","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yongjung J.","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoon Hyuk","family":"Kim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0005","doi-asserted-by":"crossref","first-page":"2510","DOI":"10.1097\/BRS.0b013e3181af2622","article-title":"Segmental contribution toward total lumbar range of motion in disc replacement and fusions: a comparison of operative and adjacent levels","volume":"34","author":"Auerbach","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"issue":"Suppl. 5","key":"10.1016\/j.clinbiomech.2015.08.009_bb0010","doi-asserted-by":"crossref","first-page":"626","DOI":"10.1007\/s00586-011-1930-3","article-title":"Sagittal balance disorders in severe degenerative spine. Can we identify the compensatory mechanisms?","volume":"20","author":"Barrey","year":"2011","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0020","first-page":"299","article-title":"Biomechanical analysis of proximal junctional kyphosis: preliminary results","volume":"176","author":"Cammarata","year":"2012","journal-title":"Stud. Health Technol. Inform."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0015","doi-asserted-by":"crossref","first-page":"E500","DOI":"10.1097\/BRS.0000000000000222","article-title":"Biomechanical risk factors for proximal junctional kyphosis: a detailed numerical analysis of surgical instrumentation variables","volume":"39","author":"Cammarata","year":"2014","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0025","doi-asserted-by":"crossref","first-page":"2374","DOI":"10.1016\/j.jbiomech.2010.04.023","article-title":"A nonlinear finite element model validation study based on a novel experimental technique for inducing anterior wedge-shape fractures in human vertebral bodies in vitro","volume":"43","author":"Dall'Ara","year":"2010","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0030","doi-asserted-by":"crossref","first-page":"1540","DOI":"10.1007\/s00586-010-1368-z","article-title":"Spinal decompensation in degenerative lumbar scoliosis","volume":"19","author":"de Vries","year":"2010","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0035","doi-asserted-by":"crossref","first-page":"1745","DOI":"10.1097\/00007632-199408000-00015","article-title":"Comparison of in vivo and in vitro adjacent segment motion after lumbar fusion","volume":"19","author":"Dekutoski","year":"1994","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0040","doi-asserted-by":"crossref","first-page":"E729","DOI":"10.1097\/BRS.0b013e3181ae2ab2","article-title":"Incidence and risk factors for proximal and distal junctional kyphosis following surgical treatment for Scheuermann kyphosis: minimum five-year follow-up","volume":"34","author":"Denis","year":"2009","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0045","doi-asserted-by":"crossref","first-page":"1757","DOI":"10.1016\/j.jbiomech.2014.04.002","article-title":"Comparison of eight published static finite element models of the intact lumbar spine: predictive power of models improves when combined together","volume":"47","author":"Dreischarf","year":"2014","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0050","doi-asserted-by":"crossref","first-page":"16","DOI":"10.1186\/1748-7161-7-16","article-title":"Proximal junctional vertebral fracture-subluxation after adult spine deformity surgery. Does vertebral augmentation avoid this complication? A case report","volume":"7","author":"Fernandez-Baillo","year":"2012","journal-title":"Scoliosis"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0055","doi-asserted-by":"crossref","first-page":"1643","DOI":"10.1097\/01.brs.0000169451.76359.49","article-title":"Proximal junctional kyphosis in adult spinal deformity following long instrumented posterior spinal fusion: incidence, outcomes, and risk factor analysis","volume":"30","author":"Glattes","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0060","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1097\/00007632-199503150-00010","article-title":"Interlaminar shear stresses and laminae separation in a disc. Finite element analysis of the L3\u2013L4 motion segment subjected to axial compressive loads","volume":"20","author":"Goel","year":"1995","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0070","doi-asserted-by":"crossref","first-page":"633","DOI":"10.1007\/s11517-006-0066-9","article-title":"Validation of a clinical finite element model of the human lumbosacral spine","volume":"44","author":"Guan","year":"2006","journal-title":"Med. Biol. Eng. Comput."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0065","doi-asserted-by":"crossref","first-page":"1975","DOI":"10.1016\/j.jbiomech.2006.09.027","article-title":"Moment-rotation responses of the human lumbosacral spinal column","volume":"40","author":"Guan","year":"2007","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0075","doi-asserted-by":"crossref","first-page":"190S","DOI":"10.1016\/j.spinee.2004.07.007","article-title":"Adjacent segment degeneration and adjacent segment disease: the consequences of spinal fusion?","volume":"4","author":"Hilibrand","year":"2004","journal-title":"Spine J."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0080","doi-asserted-by":"crossref","DOI":"10.1097\/BRS.0b013e318271319c","article-title":"Incidence, mode, and location of acute proximal junctional failures following surgical treatment for adult spinal deformity","volume":"38","author":"Hostin","year":"2013","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0085","doi-asserted-by":"crossref","first-page":"1165","DOI":"10.1016\/j.jbiomech.2003.12.026","article-title":"Mechanisms for mechanical damage in the intervertebral disc annulus fibrosus","volume":"37","author":"Iatridis","year":"2004","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0090","doi-asserted-by":"crossref","first-page":"765","DOI":"10.1093\/ptj\/60.6.765","article-title":"Biomechanics of the lumbar intervertebral disk: a review","volume":"60","author":"Jensen","year":"1980","journal-title":"Phys. Ther."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0095","doi-asserted-by":"crossref","first-page":"E1499","DOI":"10.1097\/BRS.0b013e3181e9af93","article-title":"Lumbar interspinous spacers: a systematic review of clinical and biomechanical evidence","volume":"35","author":"Kabir","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0115","doi-asserted-by":"crossref","first-page":"2045","DOI":"10.1097\/01.brs.0000179084.45839.ad","article-title":"Proximal junctional kyphosis in adolescent idiopathic scoliosis following segmental posterior spinal instrumentation and fusion: minimum 5-year follow-up","volume":"30","author":"Kim","year":"2005","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0120","doi-asserted-by":"crossref","first-page":"2343","DOI":"10.1097\/01.brs.0000238970.67552.f5","article-title":"An analysis of sagittal spinal alignment following long adult lumbar instrumentation and fusion to L5 or S1: can we predict ideal lumbar lordosis?","volume":"31","author":"Kim","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0125","doi-asserted-by":"crossref","first-page":"2359","DOI":"10.1097\/01.brs.0000238969.59928.73","article-title":"Sagittal thoracic decompensation following long adult lumbar spinal instrumentation and fusion to L5 or S1: causes, prevalence, and risk factor analysis","volume":"31","author":"Kim","year":"2006","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0100","doi-asserted-by":"crossref","first-page":"19","DOI":"10.4184\/asj.2007.1.1.19","article-title":"Incidence of proximal adjacent failure in adult lumbar deformity correction based on proximal fusion level","volume":"1","author":"Kim","year":"2007","journal-title":"Asian Spine J."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0130","doi-asserted-by":"crossref","first-page":"2653","DOI":"10.1097\/BRS.0b013e31815a5a9d","article-title":"Is the T9, T11, or L1 the more reliable proximal level after adult lumbar or lumbosacral instrumented fusion to L5 or S1?","volume":"32","author":"Kim","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0110","doi-asserted-by":"crossref","first-page":"2179","DOI":"10.1097\/BRS.0b013e31817c0428","article-title":"Proximal junctional kyphosis in adult spinal deformity after segmental posterior spinal instrumentation and fusion: minimum five-year follow-up","volume":"33","author":"Kim","year":"2008","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0105","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1243\/09544119JEIM611","article-title":"Stress analysis in a pedicle screw fixation system with flexible rods in the lumbar spine","volume":"224","author":"Kim","year":"2010","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0135","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1016\/j.spinee.2012.01.014","article-title":"Assessment of pedicle screw pullout strength based on various screw designs and bone densities\u2014an ex vivo biomechanical study","volume":"12","author":"Kim","year":"2012","journal-title":"Spine J."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0140","doi-asserted-by":"crossref","first-page":"574","DOI":"10.1097\/00007632-198409000-00007","article-title":"Lumbosacral spinal fusion. A biomechanical study","volume":"9","author":"Lee","year":"1984","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0145","first-page":"29","article-title":"Adjacent segment degeneration following spinal fusion for degenerative disc disease","volume":"65","author":"Levin","year":"2007","journal-title":"Bull. NYU Hosp. Jt. Dis."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0150","doi-asserted-by":"crossref","first-page":"969","DOI":"10.1080\/10255842.2010.502894","article-title":"Biomechanical effect after Coflex and Coflex rivet implantation for segmental instability at surgical and adjacent segments: a finite element analysis","volume":"14","author":"Lo","year":"2011","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0155","doi-asserted-by":"crossref","first-page":"2570","DOI":"10.1097\/00007632-199611150-00006","article-title":"Do bending, twisting, and diurnal fluid changes in the disc affect the propensity to prolapse? A viscoelastic finite element model","volume":"21","author":"Lu","year":"1996","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0160","doi-asserted-by":"crossref","DOI":"10.1007\/s00586-015-3992-0","article-title":"Do in vivo kinematic studies provide insight into adjacent segment degeneration? A qualitative systematic literature review","author":"Malakoutian","year":"2015","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0165","series-title":"Proximal Junctional Kyphosis Following Surgical Treatment of Global Sagittal Imbalance: Predictive Analysis Using Mathematical and In Vitro Biomechanical Models","author":"Murray","year":"2012"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0170","doi-asserted-by":"crossref","first-page":"1873","DOI":"10.1097\/00007632-199909150-00003","article-title":"The influence of lumbar disc height and cross-sectional area on the mechanical response of the disc to physiologic loading","volume":"24","author":"Natarajan","year":"1999","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0175","doi-asserted-by":"crossref","first-page":"955","DOI":"10.1097\/00007632-200004150-00010","article-title":"Anterior cervical fusion: a finite element model study on motion segment stability including the effect of osteoporosis","volume":"25","author":"Natarajan","year":"2000","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0185","doi-asserted-by":"crossref","first-page":"257","DOI":"10.1016\/j.clinbiomech.2006.08.006","article-title":"Hybrid multidirectional test method to evaluate spinal adjacent-level effects","volume":"22","author":"Panjabi","year":"2007","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0190","doi-asserted-by":"crossref","first-page":"413","DOI":"10.2106\/00004623-199403000-00012","article-title":"Mechanical behavior of the human lumbar and lumbosacral spine as shown by three-dimensional load-displacement curves","volume":"76","author":"Panjabi","year":"1994","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0180","doi-asserted-by":"crossref","first-page":"959","DOI":"10.1097\/01.brs.0000260792.13893.88","article-title":"Hybrid testing of lumbar CHARITE discs versus fusions","volume":"32","author":"Panjabi","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0200","doi-asserted-by":"crossref","first-page":"443","DOI":"10.1007\/s00776-009-1341-z","article-title":"Biomechanical comparison of instrumentation techniques in treatment of thoracolumbar burst fractures: a finite element analysis","volume":"14","author":"Park","year":"2009","journal-title":"J. Orthop. Sci."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0195","doi-asserted-by":"crossref","first-page":"1234","DOI":"10.1016\/j.compbiomed.2013.06.011","article-title":"Effects of degenerated intervertebral discs on intersegmental rotations, intradiscal pressures, and facet joint forces of the whole lumbar spine","volume":"43","author":"Park","year":"2013","journal-title":"Comput. Biol. Med."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0205","doi-asserted-by":"crossref","first-page":"2484","DOI":"10.1016\/j.jbiomech.2005.07.026","article-title":"Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element method","volume":"39","author":"Rohlmann","year":"2006","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0210","doi-asserted-by":"crossref","first-page":"341","DOI":"10.1016\/j.jbiomech.2008.11.024","article-title":"Influence of single-level lumbar degenerative disc disease on the behavior of the adjacent segments\u2014a finite element model study","volume":"42","author":"Ruberte","year":"2009","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0215","doi-asserted-by":"crossref","first-page":"337","DOI":"10.1016\/j.clinbiomech.2005.12.001","article-title":"Application of a new calibration method for a three-dimensional finite element model of a human lumbar annulus fibrosus","volume":"21","author":"Schmidt","year":"2006","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0225","doi-asserted-by":"crossref","first-page":"748","DOI":"10.1097\/01.brs.0000259059.90430.c2","article-title":"Intradiscal pressure, shear strain, and fiber strain in the intervertebral disc under combined loading","volume":"32","author":"Schmidt","year":"2007","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0230","doi-asserted-by":"crossref","first-page":"988","DOI":"10.1016\/j.clinbiomech.2007.07.008","article-title":"The risk of disc prolapses with complex loading in different degrees of disc degeneration \u2014 a finite element analysis","volume":"22","author":"Schmidt","year":"2007","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0220","doi-asserted-by":"crossref","first-page":"642","DOI":"10.1016\/j.medengphy.2008.12.004","article-title":"Dependency of disc degeneration on shear and tensile strains between annular fiber layers for complex loads","volume":"31","author":"Schmidt","year":"2009","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0235","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1097\/00007632-198611000-00012","article-title":"Mechanical response of a lumbar motion segment in axial torque alone and combined with compression","volume":"11","author":"Shirazi-Adl","year":"1986","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0240","doi-asserted-by":"crossref","first-page":"2171","DOI":"10.1007\/s00586-010-1549-9","article-title":"Dynamic stabilization adjacent to single-level fusion: part I. Biomechanical effects on lumbar spinal motion","volume":"19","author":"Strube","year":"2010","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0245","series-title":"Paper presented at: 37th Annual Scoliosis Research Society Meeting September 18\u201321, Seattle, WA","article-title":"Adjacent segment failure above lumbosacral fusions instrumented to L1 or L2","author":"Swank","year":"2002"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0250","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1115\/1.3138670","article-title":"A three-dimensional nonlinear finite element model of lumbar intervertebral joint in torsion","volume":"109","author":"Ueno","year":"1987","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0255","doi-asserted-by":"crossref","first-page":"901","DOI":"10.1016\/j.orthres.2003.12.012","article-title":"Theoretical model and experimental results for the nonlinear elastic behavior of human annulus fibrosus","volume":"22","author":"Wagner","year":"2004","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0260","doi-asserted-by":"crossref","first-page":"138","DOI":"10.1097\/BRS.0b013e3181c8f35d","article-title":"Proximal junctional vertebral fracture in adults after spinal deformity surgery using pedicle screw constructs: analysis of morphological features","volume":"35","author":"Watanabe","year":"2010","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0265","doi-asserted-by":"crossref","first-page":"526","DOI":"10.1097\/00007632-199503010-00004","article-title":"Intradiscal pressure measurements above an instrumented fusion. A cadaveric study","volume":"20","author":"Weinhoffer","year":"1995","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0270","series-title":"Clinical biomechanics of the spine","author":"White","year":"1990"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0275","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1007\/s00586-008-0657-2","article-title":"Biomechanical effect of different lumbar interspinous implants on flexibility and intradiscal pressure","volume":"17","author":"Wilke","year":"2008","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0280","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1007\/s00402-011-1439-6","article-title":"A comparative study on screw loosening in osteoporotic lumbar spine fusion between expandable and conventional pedicle screws","volume":"132","author":"Wu","year":"2012","journal-title":"Arch. Orthop. Trauma Surg."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0285","doi-asserted-by":"crossref","first-page":"E60","DOI":"10.1097\/BRS.0b013e3181eeaee2","article-title":"Incidence, risk factors and classification of proximal junctional kyphosis: surgical outcomes review of adult idiopathic scoliosis","volume":"36","author":"Yagi","year":"2011","journal-title":"Spine (Phila Pa 1976)"},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0290","doi-asserted-by":"crossref","first-page":"479","DOI":"10.1016\/j.jbiomech.2003.09.005","article-title":"Investigation of fixation screw pull-out strength on human spine","volume":"37","author":"Zhang","year":"2004","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0295","doi-asserted-by":"crossref","first-page":"795","DOI":"10.1016\/j.medengphy.2005.11.009","article-title":"Effects of bone materials on the screw pull-out strength in human spine","volume":"28","author":"Zhang","year":"2006","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.clinbiomech.2015.08.009_bb0300","doi-asserted-by":"crossref","first-page":"365","DOI":"10.1016\/0268-0033(96)00010-1","article-title":"The accumulation of fatigue microdamage in human cortical bone of two different ages in vitro","volume":"11","author":"Zioupos","year":"1996","journal-title":"Clin. Biomech."}],"container-title":["Clinical Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003315002211?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003315002211?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,9,20]],"date-time":"2018-09-20T03:54:19Z","timestamp":1537415659000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0268003315002211"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2015,12]]},"references-count":60,"journal-issue":{"issue":"10","published-print":{"date-parts":[[2015,12]]}},"alternative-id":["S0268003315002211"],"URL":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2015.08.009","relation":{},"ISSN":["0268-0033"],"issn-type":[{"value":"0268-0033","type":"print"}],"subject":[],"published":{"date-parts":[[2015,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Biomechanical effects of fusion levels on the risk of proximal junctional failure and kyphosis in lumbar spinal fusion surgery","name":"articletitle","label":"Article Title"},{"value":"Clinical Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2015.08.009","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2015 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}