{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T17:17:04Z","timestamp":1786987024889,"version":"build-2736575974"},"reference-count":52,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2017,1,1]],"date-time":"2017-01-01T00:00:00Z","timestamp":1483228800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["31300779"],"award-info":[{"award-number":["31300779"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100001809","name":"National Natural Science Foundation of China","doi-asserted-by":"publisher","award":["81572138"],"award-info":[{"award-number":["81572138"]}],"id":[{"id":"10.13039\/501100001809","id-type":"DOI","asserted-by":"publisher"}]},{"name":"Fundamental Research Funds","award":["20152152"],"award-info":[{"award-number":["20152152"]}]}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","clinbiomech.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Biomechanics"],"published-print":{"date-parts":[[2017,1]]},"DOI":"10.1016\/j.clinbiomech.2016.11.007","type":"journal-article","created":{"date-parts":[[2016,11,26]],"date-time":"2016-11-26T00:35:37Z","timestamp":1480120537000},"page":"34-38","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":33,"special_numbering":"C","title":["The effects of muscle weakness on degenerative spondylolisthesis: A finite element study"],"prefix":"10.1016","volume":"41","author":[{"given":"Rui","family":"Zhu","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Wen-xin","family":"Niu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhi-li","family":"Zeng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jian-hua","family":"Tong","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhi-wei","family":"Zhen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shuang","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Yan","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Li-ming","family":"Cheng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0005","doi-asserted-by":"crossref","first-page":"1972","DOI":"10.1016\/j.jbiomech.2005.03.028","article-title":"Spine biomechanics","volume":"38","author":"Adams","year":"2005","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0010","doi-asserted-by":"crossref","first-page":"533","DOI":"10.1016\/j.clinbiomech.2009.05.008","article-title":"Comparison of trunk muscle forces and spinal loads estimated by two biomechanical models","volume":"24","author":"Arjmand","year":"2009","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0015","doi-asserted-by":"crossref","first-page":"695","DOI":"10.1080\/10255842.2010.493517","article-title":"Parametric convergence sensitivity and validation of a finite element model of the human lumbar spine","volume":"14","author":"Ayturk","year":"2011","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0020","doi-asserted-by":"crossref","first-page":"954","DOI":"10.1097\/00007632-200205010-00014","article-title":"Intraoperative measurement of lumbar spine motion segment stiffness","volume":"27","author":"Brown","year":"2002","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0025","doi-asserted-by":"crossref","first-page":"727","DOI":"10.1016\/S0021-9290(99)00052-4","article-title":"Estimation of trunk muscle forces using the finite element method and in vivo loads measured by telemeterized internal spinal fixation devices","volume":"32","author":"Calisse","year":"1999","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0030","first-page":"45","article-title":"Biomechanics of grade I degenerative lumbar spondylolisthesis. Part 1: in vitro model","volume":"94","author":"Crawford","year":"2001","journal-title":"J. Neurosurg."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0035","doi-asserted-by":"crossref","first-page":"11","DOI":"10.1016\/j.pain.2009.01.002","article-title":"What causes low back pain?","volume":"142","author":"Devor","year":"2009","journal-title":"Pain"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0040","doi-asserted-by":"crossref","first-page":"562","DOI":"10.1097\/00007632-199105000-00014","article-title":"Functional radiographic diagnosis of the lumbar spine. Flexion-extension and lateral bending","volume":"16","author":"Dvorak","year":"1991","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0045","doi-asserted-by":"crossref","first-page":"S44","DOI":"10.1097\/00007632-199203001-00010","article-title":"Intraoperative measurement of lumbar spinal instability","volume":"17","author":"Ebara","year":"1992","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0050","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1080\/10255840108908005","article-title":"An anisotropic model for annulus tissue and enhanced finite element analyses of intact lumbar disc bodies","volume":"4","author":"Eberlein","year":"2000","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0055","doi-asserted-by":"crossref","first-page":"218","DOI":"10.1097\/00007632-200101150-00019","article-title":"Structural features and thickness of the vertebral cortex in the thoracolumbar spine","volume":"26","author":"Edwards","year":"2001","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0060","first-page":"431","article-title":"A biomechanical study of L5-S1 low-grade isthmic spondylolisthesis using a personalized finite element model","volume":"123","author":"El-Rich","year":"2006","journal-title":"Stud. Health Technol. Inform."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0065","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1080\/10255840802069823","article-title":"Mechanical loading effects on isthmic spondylolytic lumbar segment: finite element modelling using a personalised geometry","volume":"12","author":"El-Rich","year":"2009","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0070","doi-asserted-by":"crossref","first-page":"463","DOI":"10.3928\/0147-7447-19910401-11","article-title":"Instability in spondylolisthesis","volume":"14","author":"Friberg","year":"1991","journal-title":"Orthopedics"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0075","doi-asserted-by":"crossref","first-page":"9","DOI":"10.5435\/00124635-199401000-00002","article-title":"Degenerative spondylolisthesis: diagnosis and treatment","volume":"2","author":"Frymoyer","year":"1994","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0080","doi-asserted-by":"crossref","first-page":"1521","DOI":"10.1016\/j.jbiomech.2011.03.002","article-title":"An improved multi-joint EMG-assisted optimization approach to estimate joint and muscle forces in a musculoskeletal model of the lumbar spine","volume":"44","author":"Gagnon","year":"2011","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0085","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1097\/00007632-198809000-00007","article-title":"An analytical investigation of the mechanics of spinal instrumentation","volume":"13","author":"Goel","year":"1988","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0090","doi-asserted-by":"crossref","first-page":"1531","DOI":"10.1097\/00007632-199318110-00019","article-title":"A combined finite element and optimization investigation of lumbar spine mechanics with and without muscles","volume":"18","author":"Goel","year":"1993","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0095","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1097\/00007632-198903000-00014","article-title":"Roentgenographic evaluation of lumbar spine flexion-extension in asymptomatic individuals","volume":"14","author":"Hayes","year":"1989","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0100","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1097\/00007632-199505000-00018","article-title":"Spine update. Degenerative lumbar spondylolisthesis","volume":"20","author":"Herkowitz","year":"1995","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0105","first-page":"656","article-title":"Spondylolisthesis and spondylolysis","volume":"90","author":"Hu","year":"2008","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0110","doi-asserted-by":"crossref","first-page":"289","DOI":"10.1007\/s00586-010-1641-1","article-title":"Biomechanical evaluation of posterior lumbar dynamic stabilization: an in vitro comparison between universal clamp and Wallis systems","volume":"20","author":"Ilharreborde","year":"2011","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0115","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1007\/s00586-008-0874-8","article-title":"Reviewer's comments concerning \u201cBiomechanical evaluation of segmental instability in degenerative lumbar spondylolisthesis\u201d by K. Hasegawa et al. (ESJO-D-08-00441R1)","volume":"18","author":"Ito","year":"2009","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0120","doi-asserted-by":"crossref","first-page":"327","DOI":"10.1007\/s00586-007-0543-3","article-title":"Diagnosis and conservative management of degenerative lumbar spondylolisthesis","volume":"17","author":"Kalichman","year":"2008","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0125","doi-asserted-by":"crossref","DOI":"10.1115\/1.2907739","article-title":"Role of trunk muscles in generating follower load in the lumbar spine of neutral standing posture","volume":"130","author":"Kim","year":"2008","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0130","doi-asserted-by":"crossref","first-page":"E38","DOI":"10.1097\/00007632-200102150-00003","article-title":"The pathomechanism of spondylolytic spondylolisthesis in immature primate lumbar spines in vitro and finite element assessments","volume":"26","author":"Konz","year":"2001","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0135","doi-asserted-by":"crossref","first-page":"450","DOI":"10.1002\/jor.22792","article-title":"The effect of disc degeneration on anterior shear translation in the lumbar spine","volume":"33","author":"Melnyk","year":"2015","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0140","doi-asserted-by":"crossref","first-page":"706","DOI":"10.1016\/j.spinee.2013.02.017","article-title":"Segmental spinal canal volume in patients with degenerative spondylolisthesis","volume":"13","author":"Miao","year":"2013","journal-title":"Spine J."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0145","doi-asserted-by":"crossref","first-page":"254","DOI":"10.1007\/s00586-008-0822-7","article-title":"Investigation of solute concentrations in a 3D model of intervertebral disc","volume":"18","author":"Mokhbi Soukane","year":"2009","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0150","doi-asserted-by":"crossref","first-page":"1103","DOI":"10.1097\/01.BRS.0000067273.32911.C7","article-title":"Effects of slip severity and loading directions on the stability of isthmic spondylolisthesis: a finite element model study","volume":"28","author":"Natarajan","year":"2003","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0155","series-title":"Clinical Implant Materials","first-page":"663","article-title":"Biomechanical properties of lumbar spinal ligaments","volume":"9","author":"Nolte","year":"1990"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0160","doi-asserted-by":"crossref","first-page":"981","DOI":"10.1016\/j.jbiomech.2005.02.019","article-title":"Determination of trunk muscle forces for flexion and extension by using a validated finite element model of the lumbar spine and measured in vivo data","volume":"39","author":"Rohlmann","year":"2006","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0165","doi-asserted-by":"crossref","first-page":"1520","DOI":"10.1016\/j.jbiomech.2009.03.048","article-title":"Applying a follower load delivers realistic results for simulating standing","volume":"42","author":"Rohlmann","year":"2009","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0170","doi-asserted-by":"crossref","first-page":"884","DOI":"10.1016\/j.jbiomech.2009.01.017","article-title":"Realistic loading conditions for upper body bending","volume":"42","author":"Rohlmann","year":"2009","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0175","doi-asserted-by":"crossref","first-page":"2484","DOI":"10.1016\/j.jbiomech.2005.07.026","article-title":"Analysis of the influence of disc degeneration on the mechanical behaviour of a lumbar motion segment using the finite element method","volume":"39","author":"Rohlmann","year":"2006","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0180","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1177\/0363546504269035","article-title":"Athletes with unilateral spondylolysis are at risk of stress fracture at the contralateral pedicle and pars interarticularis: a clinical and biomechanical study","volume":"33","author":"Sairyo","year":"2005","journal-title":"Am. J. Sports Med."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0185","doi-asserted-by":"crossref","first-page":"887","DOI":"10.1097\/00007632-199504150-00003","article-title":"Role of ligaments and facets in lumbar spinal stability","volume":"20","author":"Sharma","year":"1995","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0190","doi-asserted-by":"crossref","first-page":"914","DOI":"10.1097\/00007632-198611000-00012","article-title":"Mechanical response of a lumbar motion segment in axial torque alone and combined with compression","volume":"11","author":"Shirazi-Adl","year":"1986","journal-title":"Spine"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0195","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1007\/s00586-004-0779-0","article-title":"Spinal muscle forces, internal loads and stability in standing under various postures and loads-application of kinematics-based algorithm","volume":"14","author":"Shirazi-Adl","year":"2005","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0200","doi-asserted-by":"crossref","first-page":"261","DOI":"10.2463\/mrms.2013-0099","article-title":"Investigation of intervertebral disc and facet joint in lumbar spondylolisthesis using T2 mapping","volume":"13","author":"Takashima","year":"2014","journal-title":"Magn. Reson. Med. Sci."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0205","doi-asserted-by":"crossref","first-page":"S10","DOI":"10.1016\/S0268-0033(03)00079-2","article-title":"Differences of lumbosacral kinematics between degenerative and induced spondylolisthetic spine","volume":"18","author":"Tsai","year":"2003","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0210","doi-asserted-by":"crossref","first-page":"200","DOI":"10.1115\/1.3138670","article-title":"A three-dimensional nonlinear finite element model of lumbar intervertebral joint in torsion","volume":"109","author":"Ueno","year":"1987","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0215","doi-asserted-by":"crossref","first-page":"222","DOI":"10.1097\/01.blo.0000200233.99436.ea","article-title":"Treatment of instability and spondylolisthesis: surgical versus nonsurgical treatment","volume":"443","author":"Vibert","year":"2006","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0220","first-page":"301","article-title":"Finite element analysis of the spondylolysis in lumbar spine","volume":"16","author":"Wang","year":"2006","journal-title":"Biomed. Mater. Eng."},{"issue":"Suppl. 1","key":"10.1016\/j.clinbiomech.2016.11.007_bb0225","doi-asserted-by":"crossref","first-page":"S111","DOI":"10.1016\/S0268-0033(00)00103-0","article-title":"Intradiscal pressure together with anthropometric data\u2013a data set for the validation of models","volume":"16","author":"Wilke","year":"2001","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0230","first-page":"23","article-title":"Classification of spondylolisis and spondylolisthesis","author":"Wiltse","year":"1976","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0235","doi-asserted-by":"crossref","first-page":"1018","DOI":"10.1016\/j.joca.2008.01.007","article-title":"Lower cervical spine facet cartilage thickness mapping","volume":"16","author":"Womack","year":"2008","journal-title":"Osteoarthr. Cartil."},{"issue":"Suppl. 1","key":"10.1016\/j.clinbiomech.2016.11.007_bb0240","doi-asserted-by":"crossref","first-page":"S73","DOI":"10.1016\/S0268-0033(00)00108-X","article-title":"Estimation of muscle forces in the lumbar spine during upper-body inclination","volume":"16","author":"Zander","year":"2001","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0245","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1007\/s00586-003-0540-0","article-title":"Influence of graded facetectomy and laminectomy on spinal biomechanics","volume":"12","author":"Zander","year":"2003","journal-title":"Eur. Spine J."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0250","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1515\/bmt-2013-0121","article-title":"Discrepancies in anthropometric parameters between different models affect intervertebral rotations when loading finite element models with muscle forces from inverse static analyses","volume":"59","author":"Zhu","year":"2014","journal-title":"Biomed. Tech. (Berl)"},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0255","doi-asserted-by":"crossref","first-page":"771","DOI":"10.1016\/j.clinbiomech.2012.05.008","article-title":"Comparison of four reconstruction methods after total sacrectomy: a finite element study","volume":"27","author":"Zhu","year":"2012","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2016.11.007_bb0260","doi-asserted-by":"crossref","first-page":"1376","DOI":"10.1016\/j.jbiomech.2013.03.003","article-title":"Considerations when loading spinal finite element models with predicted muscle forces from inverse static analyses","volume":"46","author":"Zhu","year":"2013","journal-title":"J. Biomech."}],"container-title":["Clinical Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003316302182?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003316302182?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,7,14]],"date-time":"2022-07-14T20:05:28Z","timestamp":1657829128000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0268003316302182"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2017,1]]},"references-count":52,"alternative-id":["S0268003316302182"],"URL":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2016.11.007","relation":{},"ISSN":["0268-0033"],"issn-type":[{"value":"0268-0033","type":"print"}],"subject":[],"published":{"date-parts":[[2017,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The effects of muscle weakness on degenerative spondylolisthesis: A finite element study","name":"articletitle","label":"Article Title"},{"value":"Clinical Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2016.11.007","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}