{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,16]],"date-time":"2026-09-16T05:14:23Z","timestamp":1789535663182,"version":"build-2803163510"},"reference-count":22,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,12,1]],"date-time":"2018-12-01T00:00:00Z","timestamp":1543622400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","clinbiomech.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Biomechanics"],"published-print":{"date-parts":[[2018,12]]},"DOI":"10.1016\/j.clinbiomech.2018.10.005","type":"journal-article","created":{"date-parts":[[2018,10,4]],"date-time":"2018-10-04T06:19:22Z","timestamp":1538633962000},"page":"89-94","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"special_numbering":"C","title":["The effect of radial head prosthesis diameter on posterolateral rotatory instability of the elbow"],"prefix":"10.1016","volume":"60","author":[{"given":"Chad E.","family":"Songy","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Cory G.","family":"Couch","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Eric R.","family":"Siegel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"James R.","family":"Kee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Shahryar","family":"Ahmadi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"3","key":"10.1016\/j.clinbiomech.2018.10.005_bb0005","doi-asserted-by":"crossref","first-page":"364","DOI":"10.1016\/j.jse.2014.10.026","article-title":"The effect of fracture comminution on the reliability and accuracy of radial head sizing","volume":"24","author":"Abdulla","year":"2015","journal-title":"J. Shoulder Elb. Surg."},{"issue":"14","key":"10.1016\/j.clinbiomech.2018.10.005_bb0010","doi-asserted-by":"crossref","first-page":"1339","DOI":"10.2106\/JBJS.J.01244","article-title":"Contralateral elbow radiographs can reliably diagnose radial head implant overlengthening","volume":"93","author":"Athwal","year":"2011","journal-title":"J. Bone Joint Surg. Am."},{"issue":"7","key":"10.1016\/j.clinbiomech.2018.10.005_bb0015","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1016\/S0268-0033(03)00115-3","article-title":"The effect of radial head fracture size on radiocapitellar joint stability","volume":"18","author":"Beingessner","year":"2003","journal-title":"Clin. Biomech."},{"issue":"8","key":"10.1016\/j.clinbiomech.2018.10.005_bb0020","doi-asserted-by":"crossref","first-page":"1730","DOI":"10.2106\/00004623-200408000-00018","article-title":"The effect of radial head excision and arthroplasty on elbow kinematics and stability","volume":"86-A","author":"Beingessner","year":"2004","journal-title":"J. Bone Joint Surg. Am."},{"issue":"1","key":"10.1016\/j.clinbiomech.2018.10.005_bb0025","doi-asserted-by":"crossref","first-page":"210","DOI":"10.1016\/j.orthres.2004.06.001","article-title":"The effect of radial head fracture size on elbow kinematics and stability","volume":"23","author":"Beingessner","year":"2005","journal-title":"J. Orthop. Res."},{"issue":"2","key":"10.1016\/j.clinbiomech.2018.10.005_bb0030","doi-asserted-by":"crossref","first-page":"208","DOI":"10.1016\/j.jse.2003.11.007","article-title":"Loss of flexion after radial head replacement","volume":"13","author":"Birkedal","year":"2004","journal-title":"J. Shoulder Elb. Surg."},{"issue":"1","key":"10.1016\/j.clinbiomech.2018.10.005_bb0035","doi-asserted-by":"crossref","first-page":"53","DOI":"10.1016\/j.jhsa.2005.06.012","article-title":"Reference points for radial head prosthesis size","volume":"31","author":"Doornberg","year":"2006","journal-title":"J. Hand. Surg. [Am.]"},{"issue":"7","key":"10.1016\/j.clinbiomech.2018.10.005_bb0040","doi-asserted-by":"crossref","first-page":"1738","DOI":"10.2106\/JBJS.H.01161","article-title":"Determination of correct implant size in radial head arthroplasty to avoid overlengthening","volume":"91","author":"Frank","year":"2009","journal-title":"J. Bone Joint Surg. Am."},{"issue":"10","key":"10.1016\/j.clinbiomech.2018.10.005_bb0045","first-page":"2192","article-title":"Comminuted radial head fractures treated with a modular metallic radial head arthroplasty. Study of outcomes","volume":"88","author":"Grewal","year":"2006","journal-title":"J. Bone Joint Surg. Am."},{"issue":"7","key":"10.1016\/j.clinbiomech.2018.10.005_bb0050","first-page":"1571","article-title":"Posterolateral rotatory instability of the elbow following radial head resection","volume":"87","author":"Hall","year":"2005","journal-title":"J. Bone Joint Surg. Am."},{"issue":"1","key":"10.1016\/j.clinbiomech.2018.10.005_bb0055","doi-asserted-by":"crossref","first-page":"73","DOI":"10.1016\/j.jse.2004.07.001","article-title":"Displaced Mason type I fractures of the radial head and neck in adults: a fifteen- to thirty-three-year follow-up study","volume":"14","author":"Herbertsson","year":"2005","journal-title":"J. Shoulder Elb. Surg."},{"issue":"86-A","key":"10.1016\/j.clinbiomech.2018.10.005_bb0060","doi-asserted-by":"crossref","first-page":"569","DOI":"10.2106\/00004623-200403000-00016","article-title":"Uncomplicated Mason type-II and III fractures of the radial head and neck in adults. A long-term follow-up study","volume":"3","author":"Herbertsson","year":"2004","journal-title":"J. Bone Joint Surg. Am."},{"issue":"3","key":"10.1016\/j.clinbiomech.2018.10.005_bb0065","doi-asserted-by":"crossref","first-page":"238","DOI":"10.1016\/S1058-2746(99)90135-0","article-title":"Elbow joint kinematics after excision of the radial head","volume":"8","author":"Jensen","year":"1999","journal-title":"J. Shoulder Elb. Surg."},{"issue":"1","key":"10.1016\/j.clinbiomech.2018.10.005_bb0070","doi-asserted-by":"crossref","first-page":"78","DOI":"10.1016\/j.jse.2004.05.009","article-title":"Elbow joint laxity after experimental radial head excision and lateral collateral ligament rupture: efficacy of prosthetic replacement and ligament repair","volume":"14","author":"Jensen","year":"2005","journal-title":"J. Shoulder Elb. Surg."},{"issue":"5","key":"10.1016\/j.clinbiomech.2018.10.005_bb0075","doi-asserted-by":"crossref","first-page":"444","DOI":"10.1016\/j.clinbiomech.2015.03.012","article-title":"Radial head implant diameter: a biomechanical assessment of the forgotten dimension","volume":"30","author":"Lanting","year":"2015","journal-title":"Clin. Biomech."},{"issue":"12","key":"10.1016\/j.clinbiomech.2018.10.005_bb0080","doi-asserted-by":"crossref","first-page":"1724","DOI":"10.1016\/j.jse.2013.06.014","article-title":"Measurements of the ispilateral capitellum can reliably predict the diameter of the radial head","volume":"22","author":"Leclerc","year":"2013","journal-title":"J. Shoulder Elb. Surg."},{"issue":"172","key":"10.1016\/j.clinbiomech.2018.10.005_bb0085","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1002\/bjs.18004217203","article-title":"Some observations on fractures of the head of the radius with a review of one hundred cases","volume":"42","author":"Mason","year":"1954","journal-title":"Br. J. Surg."},{"key":"10.1016\/j.clinbiomech.2018.10.005_bb0090","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1097\/00003086-199104000-00021","article-title":"Valgus stability of the elbow. A definition of primary and secondary constraints","volume":"265","author":"Morrey","year":"1991","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"3","key":"10.1016\/j.clinbiomech.2018.10.005_bb0095","doi-asserted-by":"crossref","first-page":"440","DOI":"10.2106\/00004623-199173030-00015","article-title":"Posterolateral rotatory instability of the elbow","volume":"73","author":"O'Driscoll","year":"1991","journal-title":"J. Bone Joint Surg. Am."},{"issue":"3","key":"10.1016\/j.clinbiomech.2018.10.005_bb0100","doi-asserted-by":"crossref","first-page":"413","DOI":"10.1302\/0301-620X.89B3.18099","article-title":"Validation of the lesser sigmoid notch of the ulna as a reference point for accurate placement of a prosthesis for the head of the radius: a cadaver study","volume":"89","author":"van Riet","year":"2007","journal-title":"J. Bone Joint Surg. (Br.)"},{"issue":"5","key":"10.1016\/j.clinbiomech.2018.10.005_bb0105","doi-asserted-by":"crossref","first-page":"975","DOI":"10.2106\/00004623-200405000-00013","article-title":"Coronoid process and radial head as posterolateral rotatory stabilizers of the elbow","volume":"86-A","author":"Schneeberger","year":"2004","journal-title":"J. Bone Joint Surg. Am."},{"issue":"12","key":"10.1016\/j.clinbiomech.2018.10.005_bb0110","doi-asserted-by":"crossref","first-page":"2629","DOI":"10.2106\/00004623-200412000-00007","article-title":"Detrimental effects of overstuffing or understuffing with a radial head replacement in the medial collateral-ligament deficient elbow","volume":"86-A","author":"Van Glabbeek","year":"2004","journal-title":"J. Bone Joint Surg. Am."}],"container-title":["Clinical Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003318301025?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003318301025?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2022,9,3]],"date-time":"2022-09-03T06:57:55Z","timestamp":1662188275000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0268003318301025"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,12]]},"references-count":22,"alternative-id":["S0268003318301025"],"URL":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2018.10.005","relation":{},"ISSN":["0268-0033"],"issn-type":[{"value":"0268-0033","type":"print"}],"subject":[],"published":{"date-parts":[[2018,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"The effect of radial head prosthesis diameter on posterolateral rotatory instability of the elbow","name":"articletitle","label":"Article Title"},{"value":"Clinical Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2018.10.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}