{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,10,15]],"date-time":"2026-10-15T02:37:22Z","timestamp":1792031842049,"version":"4.4.0"},"reference-count":39,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2019,10,1]],"date-time":"2019-10-01T00:00:00Z","timestamp":1569888000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2019,7,25]],"date-time":"2019-07-25T00:00:00Z","timestamp":1564012800000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/100010269","name":"Wellcome Trust","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100010269","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinbiomech.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Biomechanics"],"published-print":{"date-parts":[[2019,10]]},"DOI":"10.1016\/j.clinbiomech.2019.07.020","type":"journal-article","created":{"date-parts":[[2019,7,19]],"date-time":"2019-07-19T11:27:12Z","timestamp":1563535632000},"page":"148-155","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":14,"special_numbering":"C","title":["Comparing thermal discomfort with skin temperature response of lower-limb prosthesis users during exercise"],"prefix":"10.1016","volume":"69","author":[{"given":"Laura E.","family":"Diment","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark S.","family":"Thompson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jeroen H.M.","family":"Bergmann","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0005","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1177\/0141076814557301","article-title":"Lower limb amputation in England: prevalence, regional variation and relationship with revascularisation, deprivation and risk factors. A retrospective review of hospital data","volume":"107","author":"Ahmad","year":"2014","journal-title":"J. R. Soc. Med."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0010","doi-asserted-by":"crossref","first-page":"977","DOI":"10.1097\/PHM.0b013e3181587f6c","article-title":"Upper-limb prosthetics: critical factors in device abandonment","volume":"86","author":"Biddiss","year":"2007","journal-title":"Am. J. Phys. Med. Rehabil."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0015","doi-asserted-by":"crossref","first-page":"346","DOI":"10.1080\/17483100701714733","article-title":"Consumer design priorities for upper limb prosthetics","volume":"2","author":"Biddiss","year":"2007","journal-title":"Disabil. Rehabil. Assist. Technol."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0020","series-title":"C-29 Disabled population by type of disability, educational level and sex. Government of India","author":"Census of India","year":"2011"},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0025","series-title":"Prosthetics &amp; Orthotics Impact Assessment: India and Bangladesh","author":"Cochrane","year":"2015"},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0030","doi-asserted-by":"crossref","first-page":"5041","DOI":"10.3390\/s140305041","article-title":"Assessment of lower limb prosthesis through wearable sensors and thermography","volume":"14","author":"Cutti","year":"2014","journal-title":"Sensors (Switzerland)"},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0035","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1177\/0309364612437905","article-title":"Motivations and barriers to prosthesis users participation in physical activity, exercise and sport: a review of the literature","volume":"36","author":"Deans","year":"2012","journal-title":"Prosthetics Orthot. Int."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0040","doi-asserted-by":"crossref","first-page":"495","DOI":"10.1016\/S0010-4825(03)00086-6","article-title":"Mathematical modeling of temperature mapping over skin surface and its implementation in thermal disease diagnostics","volume":"34","author":"Deng","year":"2004","journal-title":"Comput. Biol. Med."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0045","doi-asserted-by":"crossref","unstructured":". Despopoulos, A. & Silbernagl, S. Color atlas of physiology. (Thieme, 2003). doi:https:\/\/doi.org\/10.1213\/ANE.0b013e3181e627d4.","DOI":"10.1213\/ANE.0b013e3181e627d4"},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0050","doi-asserted-by":"crossref","first-page":"563","DOI":"10.1097\/00002060-200108000-00003","article-title":"Use and satisfaction with prosthetic devices among persons with trauma-related amputations: a long-term outcome study","volume":"80","author":"Dillingham","year":"2001","journal-title":"Am. J. Phys. Med. Rehabil."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0055","series-title":"ISPO UK Annual Scientific Meeting","article-title":"The effect of a lower-limb prosthesis on skin temperature","author":"Diment","year":"2017"},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0060","doi-asserted-by":"crossref","first-page":"659","DOI":"10.1016\/j.apmr.2004.09.003","article-title":"Dermatologic conditions associated with use of a lower-extremity prosthesis","volume":"86","author":"Dudek","year":"2005","journal-title":"Arch. Phys. Med. Rehabil."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0065","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1007\/s004840100099","article-title":"Computer prediction of human themoregulatory and temperature responses to a wide range of environmental conditions","volume":"45","author":"Fiala","year":"2001","journal-title":"Int. J. Biometeorol."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0070","doi-asserted-by":"crossref","first-page":"11513","DOI":"10.1021\/acsnano.7b06295","article-title":"Three-dimensional printed thermal regulation textiles","volume":"11","author":"Gao","year":"2017","journal-title":"ACS Nano"},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0075","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1097\/01823246-201223020-00004","article-title":"The Submaximal Clinical Exercise Tolerance Test (SXTT) to establish safe exercise prescription parameters for patients with chronic disease and disability","volume":"23","author":"Gappmaier","year":"2012","journal-title":"Cardiopulm. Phys. Ther. J."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0080","doi-asserted-by":"crossref","first-page":"855","DOI":"10.1682\/JRRD.2013.06.0133","article-title":"Prevalence of heat and perspiration discomfort inside prostheses: literature review","volume":"51","author":"Ghoseiri","year":"2014","journal-title":"J. Rehabil. Res. Dev."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0085","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1080\/03093640108726601","article-title":"Consequences of non-vascular trans-femoral amputation: a survey of quality of life, prosthetic use and problems","volume":"25","author":"Hagberg","year":"2001","journal-title":"Prosthetics Orthot. Int."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0090","doi-asserted-by":"crossref","first-page":"342","DOI":"10.1111\/j.1533-2500.2008.00216.x","article-title":"Residual limbs of amputees are significantly cooler than contralateral intact limbs","volume":"8","author":"Harden","year":"2008","journal-title":"Pain Pract"},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0095","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1097\/JPO.0b013e3181875b17","article-title":"Measuring residual limb skin temperatures at the skin-prosthesis interface","volume":"20","author":"Huff","year":"2008","journal-title":"JPO J. Prosthetics Orthot."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0100","doi-asserted-by":"crossref","first-page":"3255","DOI":"10.1001\/jama.1989.03420220069029","article-title":"Cardiorespiratory responses to aerobic training by patients with postpoliomyelitis sequelae","volume":"261","author":"Jones","year":"1989","journal-title":"JAMA J. Am. Med. Assoc."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0105","doi-asserted-by":"crossref","first-page":"933","DOI":"10.1152\/japplphysiol.00517.2016","article-title":"Restoration of thermoregulation after exercise","volume":"122","author":"Kenny","year":"2017","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0110","doi-asserted-by":"crossref","first-page":"2350","DOI":"10.1152\/japplphysiol.01107.2002","article-title":"Muscle temperature transients before, during, and after exercise measured using an intramuscular multisensor probe","volume":"94","author":"Kenny","year":"2003","journal-title":"J. Appl. Physiol."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0115","doi-asserted-by":"crossref","first-page":"292","DOI":"10.1080\/03093640601042554","article-title":"The thermal conductivity of prosthetic sockets and liners","volume":"31","author":"Klute","year":"2007","journal-title":"Prosthetics Orthot. Int."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0120","doi-asserted-by":"crossref","first-page":"3062","DOI":"10.1007\/s11999-014-3741-4","article-title":"Does activity affect residual limb skin temperatures?","volume":"472","author":"Klute","year":"2014","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0125","doi-asserted-by":"crossref","first-page":"1063","DOI":"10.1080\/09638288.2017.1422031","article-title":"Physical activity participation amongst individuals with lower limb amputation","volume":"41","author":"Langford","year":"2019","journal-title":"Disabil. Rehabil."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0130","doi-asserted-by":"crossref","DOI":"10.3389\/fphys.2018.00029","article-title":"Skin temperature measurement using contact thermometry: a systematic review of setup variables and their effects on measured values","volume":"9","author":"MacRae","year":"2018","journal-title":"Front. Physiol."},{"issue":"1\u20137","key":"10.1016\/j.clinbiomech.2019.07.020_bb0135","article-title":"Evaluation of a specific activity questionnaire to predict mortality in men referred for exercise testing","volume":"151","author":"McAuley","year":"2006","journal-title":"Am. Heart J."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0140","first-page":"264","article-title":"Neoprene thigh sleeves and muscle cooling after exercise","volume":"40","author":"Miller","year":"2005","journal-title":"J. Athl. Train."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0145","doi-asserted-by":"crossref","first-page":"101","DOI":"10.3233\/TAD-160448","article-title":"Examining the needs of affordable upper limb prosthetic users in India: a questionnaire-based survey","volume":"28","author":"Nagaraja","year":"2016","journal-title":"Technol. Disabil."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0150","first-page":"1307","article-title":"Different responses of the skin temperature to physical exercise: systematic review","author":"Neves","year":"2015","journal-title":"Conf. Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0155","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1682\/JRRD.2004.01.0013","article-title":"Residual-limb skin temperature in transtibial sockets","volume":"42","author":"Peery","year":"2005","journal-title":"J. Rehabil. Res. Dev."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0160","doi-asserted-by":"crossref","first-page":"336","DOI":"10.1109\/TNSRE.2006.881532","article-title":"A three-dimensional finite element model of the transibial residual limb and prosthetic socket to predict skin temperatures","volume":"14","author":"Peery","year":"2006","journal-title":"IEEE Trans. Neural Syst. Rehabil. Eng."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0165","doi-asserted-by":"crossref","first-page":"498","DOI":"10.1111\/apha.12231","article-title":"Skin temperature: its role in thermoregulation","volume":"210","author":"Romanovsky","year":"2014","journal-title":"Acta Physiol."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0170","first-page":"214","article-title":"Skin response to mechanical stress: adaptation rather than breakdown\u2014a review of the literature","volume":"32","author":"Sanders","year":"1995","journal-title":"J. Rehabil. Res. Dev."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0175","doi-asserted-by":"crossref","first-page":"619","DOI":"10.1682\/JRRD.2015.03.0053","article-title":"Residual limb skin temperature and thermal comfort in people with amputation during activity in a cold environment","volume":"53","author":"Segal","year":"2016","journal-title":"J. Rehabil. Res. Dev."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0180","doi-asserted-by":"crossref","first-page":"883","DOI":"10.2337\/diacare.29.04.06.dc05-2180","article-title":"The relationship among pain, sensory loss, and small nerve fibers in diabetes","volume":"29","author":"Sorensen","year":"2006","journal-title":"Diabetes Care"},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0185","doi-asserted-by":"crossref","first-page":"13","DOI":"10.1080\/08990229870925","article-title":"Temperature sensitivity of the body surface over the life span","volume":"15","author":"Stevens","year":"1998","journal-title":"Somatosens. Mot. Res."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0190","doi-asserted-by":"crossref","first-page":"129","DOI":"10.3109\/03093649209164325","article-title":"Cause of death of lower limb amputees","volume":"16","author":"Stewart","year":"1992","journal-title":"Prosthetics Orthot. Int."},{"key":"10.1016\/j.clinbiomech.2019.07.020_bb0195","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1016\/j.apmr.2007.11.005","article-title":"Estimating the prevalence of limb loss in the United States: 2005 to 2050","volume":"89","author":"Ziegler-Graham","year":"2008","journal-title":"Arch. Phys. Med. Rehabil."}],"container-title":["Clinical Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S026800331930213X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S026800331930213X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,2]],"date-time":"2025-10-02T16:48:23Z","timestamp":1759423703000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S026800331930213X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2019,10]]},"references-count":39,"alternative-id":["S026800331930213X"],"URL":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2019.07.020","relation":{},"ISSN":["0268-0033"],"issn-type":[{"value":"0268-0033","type":"print"}],"subject":[],"published":{"date-parts":[[2019,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparing thermal discomfort with skin temperature response of lower-limb prosthesis users during exercise","name":"articletitle","label":"Article Title"},{"value":"Clinical Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2019.07.020","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2019 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}]}}