{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,3]],"date-time":"2026-09-03T16:58:58Z","timestamp":1788454738357,"version":"build-2803163510"},"reference-count":53,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,3,1]],"date-time":"2020-03-01T00:00:00Z","timestamp":1583020800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,3,1]],"date-time":"2020-03-01T00:00:00Z","timestamp":1583020800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinbiomech.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Biomechanics"],"published-print":{"date-parts":[[2020,3]]},"DOI":"10.1016\/j.clinbiomech.2020.01.017","type":"journal-article","created":{"date-parts":[[2020,1,20]],"date-time":"2020-01-20T11:33:23Z","timestamp":1579520003000},"page":"201-212","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":29,"special_numbering":"C","title":["Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: An early implant loosening case study"],"prefix":"10.1016","volume":"73","author":[{"given":"Dale L.","family":"Robinson","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Lauren","family":"Safai","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vahidreza Jafari","family":"Harandi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mark","family":"Graf","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L. Eduardo Cofr\u00e9","family":"Lizama","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Peter","family":"Lee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Mary P.","family":"Galea","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Fary","family":"Khan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Kwong Ming","family":"Tse","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David C.","family":"Ackland","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0005","doi-asserted-by":"crossref","first-page":"1463","DOI":"10.1016\/j.jbiomech.2012.02.023","article-title":"Sensitivity of model predictions of muscle function to changes in moment arms and muscle\u2013tendon properties: a Monte-Carlo analysis","volume":"45","author":"Ackland","year":"2012","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0010","doi-asserted-by":"crossref","first-page":"900","DOI":"10.2106\/JBJS.15.00808","article-title":"Safety of osseointegrated implants for transfemoral amputees: a two-center prospective cohort study","volume":"98","author":"Al Muderis","year":"2016","journal-title":"J. Bone Jt. Surg. - Am"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0015","doi-asserted-by":"crossref","first-page":"952","DOI":"10.1302\/0301-620X.98B7.37547","article-title":"The Osseointegration Group of Australia Accelerated Protocol (OGAAP-1) for two-stage osseointegrated reconstruction of amputated limbs","volume":"98","author":"Al Muderis","year":"2016","journal-title":"Bone Joint J"},{"issue":"4","key":"10.1016\/j.clinbiomech.2020.01.017_bb0020","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1007\/s00113-016-0296-8","article-title":"Osseointegrated prosthetic limb for the treatment of lower limb amputationsDas Osseointegrated prosthetic limb zur Behandlung von Amputationen der unteren Extremit\u00e4ten","volume":"120","author":"Al Muderis","year":"2017","journal-title":"Unfallchirurg"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0025","doi-asserted-by":"crossref","DOI":"10.1136\/bmjopen-2016-013508","article-title":"Single-stage osseointegrated reconstruction and rehabilitation of lower limb amputees: the Osseointegration Group of Australia Accelerated Protocol-2 (OGAAP-2) for a prospective cohort study","volume":"7","author":"Al Muderis","year":"2017","journal-title":"BMJ Open"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0030","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1093\/milmed\/usx185","article-title":"Two-stage osseointegrated reconstruction of post-traumatic unilateral transfemoral amputees","volume":"183","author":"Al Muderis","year":"2018","journal-title":"Mil. Med."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0035","first-page":"441","article-title":"Image-based musculoskeletal modeling: applications, advances, and future opportunities","volume":"25","author":"Blemker","year":"2007","journal-title":"J. Magn. Reson. Imaging An Off. J. Int. Soc. Magn. Reson. Med."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0040","first-page":"175","article-title":"Osseointegration in skeletal reconstruction and rehabilitation: a review","volume":"38","author":"Branemark","year":"2001","journal-title":"J. Rehabil. Res. Dev."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0045","doi-asserted-by":"crossref","first-page":"106","DOI":"10.1302\/0301-620X.96B1.31905","article-title":"A novel osseointegrated percutaneous prosthetic system for the treatment of patients with transfemoral amputation: a prospective study of 51 patients","volume":"96","author":"Br\u00e5nemark","year":"2014","journal-title":"Bone Joint J"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0050","doi-asserted-by":"crossref","first-page":"e743","DOI":"10.5435\/JAAOS-D-17-00621","article-title":"Osseointegrated percutaneous prosthetic system for the treatment of patients with transfemoral amputation: a prospective five-year follow-up of patient-reported outcomes and complications","volume":"27","author":"Br\u00e5nemark","year":"2019","journal-title":"J. Am. Acad. Orthop. Surg."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0055","doi-asserted-by":"crossref","first-page":"6","DOI":"10.1359\/jbmr.1997.12.1.6","article-title":"Bone microdamage and skeletal fragility in osteoporotic and stress fractures","volume":"12","author":"Burr","year":"1997","journal-title":"J. Bone Miner. Res."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0060","doi-asserted-by":"crossref","first-page":"481","DOI":"10.3109\/17453678108992136","article-title":"Fatigue behavior of adult cortical bone: the influence of mean strain and strain range","volume":"52","author":"Carter","year":"1981","journal-title":"Acta Orthop. Scand."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0065","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1007\/s12541-016-0097-6","article-title":"Lattice Ti structures with low rigidity but compatible mechanical strength: design of implant materials for trabecular bone","volume":"17","author":"Chen","year":"2016","journal-title":"Int. J. Precis. Eng. Manuf."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0070","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1080\/10255842.2011.554413","article-title":"Estimates of muscle function in human gait depend on how foot-ground contact is modelled","volume":"15","author":"Dorn","year":"2012","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0075","doi-asserted-by":"crossref","first-page":"349","DOI":"10.1097\/BCO.0000000000000248","article-title":"Clinical outcome of osseointegrated prostheses for lower extremity amputations: a systematic review of the literature","volume":"26","author":"van Eck","year":"2015","journal-title":"Curr. Orthop. Pract."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0080","doi-asserted-by":"crossref","first-page":"186","DOI":"10.1080\/03093640108726601","article-title":"Consequences of non-vascular trans-femoral amputation: a survey of quality of life, prosthetic use and problems","volume":"25","author":"Hagberg","year":"2001","journal-title":"Prosthetics Orthot. Int."},{"issue":"3","key":"10.1016\/j.clinbiomech.2020.01.017_bb0085","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1682\/JRRD.2008.06.0080","article-title":"One hundred patients treated with osseointegrated transfemoral amputation prostheses\u2014rehabilitation perspective","volume":"46","author":"Hagberg","year":"2009","journal-title":"J. Rehabil. Res. Dev."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0090","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1080\/03093640500238014","article-title":"Socket versus bone-anchored trans-femoral prostheses: hip range of motion and sitting comfort","volume":"29","author":"Hagberg","year":"2005","journal-title":"Prosthetics Orthot. Int."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0095","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1080\/03093640701553922","article-title":"Osseointegrated trans-femoral amputation prostheses: prospective results of general and condition-specific quality of life in 18 patients at 2-year follow-up","volume":"32","author":"Hagberg","year":"2008","journal-title":"Prosthetics Orthot. Int."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0100","doi-asserted-by":"crossref","first-page":"595","DOI":"10.1016\/j.medengphy.2008.11.015","article-title":"Risk of failure during gait for direct skeletal attachment of a femoral prosthesis: a finite element study","volume":"31","author":"Helgason","year":"2009","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0105","first-page":"239","article-title":"Resultant and local loading in models of joint disease","volume":"49","author":"Herzog","year":"2003","journal-title":"Arthritis Care Res. Off. J. Am. Coll. Rheumatol."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0110","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1016\/0021-9290(87)90030-3","article-title":"Adaptive bone-remodeling theory applied to prosthetic-design analysis","volume":"20","author":"Huiskes","year":"1987","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0115","doi-asserted-by":"crossref","first-page":"407","DOI":"10.1682\/JRRD.2014.11.0280","article-title":"Of artificial limb attachment system","volume":"52","author":"Juhnke","year":"2015","journal-title":"J. Rehabil. Res. Dev."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0120","doi-asserted-by":"crossref","first-page":"24","DOI":"10.1002\/jmri.25577","article-title":"Imaging near orthopedic hardware","volume":"46","author":"Koff","year":"2017","journal-title":"J. Magn. Reson. Imaging"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0125","doi-asserted-by":"crossref","first-page":"1243","DOI":"10.1016\/j.clinbiomech.2008.06.012","article-title":"FE stress analysis of the interface between the bone and an osseointegrated implant for amputees\u2013implications to refine the rehabilitation program","volume":"23","author":"Lee","year":"2008","journal-title":"Clin. Biomech."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0130","doi-asserted-by":"crossref","first-page":"147","DOI":"10.1080\/09593985.2016.1265620","article-title":"Gait rehabilitation for a patient with an osseointegrated prosthesis following transfemoral amputation","volume":"33","author":"Leijendekkers","year":"2017","journal-title":"Physiother. Theory Pract."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0135","doi-asserted-by":"crossref","first-page":"919","DOI":"10.1016\/j.bone.2006.10.027","article-title":"Effect of mechanical stimuli on skeletal regeneration around implants","volume":"40","author":"Leucht","year":"2007","journal-title":"Bone"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0140","doi-asserted-by":"crossref","first-page":"501","DOI":"10.1016\/S0190-9622(00)90227-5","article-title":"Skin disorders in amputees","volume":"42","author":"Lyon","year":"2000","journal-title":"J. Am. Acad. Dermatol."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0145","doi-asserted-by":"crossref","first-page":"522","DOI":"10.1080\/09638280010029859","article-title":"Phantom limb pain and residual limb pain following lower limb amputation: a descriptive analysis","volume":"23","author":"MacLachlan","year":"2001","journal-title":"Disabil. Rehabil."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0150","first-page":"161","article-title":"State-of-the-art research in lower-limb prosthetic biomechanics-socket interface: a review","volume":"38","author":"Mak","year":"2001","journal-title":"J. Rehabil. Res. Dev."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0155","doi-asserted-by":"crossref","first-page":"1784","DOI":"10.1016\/j.jbiomech.2014.03.036","article-title":"Strain energy in the femoral neck during exercise","volume":"47","author":"Martelli","year":"2014","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0160","doi-asserted-by":"crossref","first-page":"300","DOI":"10.1007\/s00113-017-0339-9","article-title":"The Compress\u00ae transcutaneous implant for rehabilitation following limb amputation","volume":"120","author":"McGough","year":"2017","journal-title":"Unfallchirurg"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0165","doi-asserted-by":"crossref","first-page":"569","DOI":"10.1016\/S0021-9290(01)00011-2","article-title":"Dependence of yield strain of human trabecular bone on anatomic site","volume":"34","author":"Morgan","year":"2001","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0170","doi-asserted-by":"crossref","first-page":"897","DOI":"10.1016\/S0021-9290(03)00071-X","article-title":"Trabecular bone modulus-density relationships depend on anatomic site","volume":"36","author":"Morgan","year":"2003","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0175","doi-asserted-by":"crossref","first-page":"707","DOI":"10.1016\/j.jbiomech.2004.05.013","article-title":"Trabecular bone microdamage and microstructural stresses under uniaxial compression","volume":"38","author":"Nagaraja","year":"2005","journal-title":"J. Biomech."},{"issue":"2","key":"10.1016\/j.clinbiomech.2020.01.017_bb2020","doi-asserted-by":"crossref","first-page":"121","DOI":"10.3109\/17453674.2012.678799","article-title":"\u201cStable fixation of an osseointegated implant system for above-the-knee amputees: titel RSA and radiographic evaluation of migration and bone remodeling in 55 cases","volume":"83","author":"Nebergall","year":"2012","journal-title":"Acta Orthop"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0180","series-title":"Recent Advances in Arthroplasty","article-title":"Titanium as a biomaterial for implants","author":"Oldani","year":"2012"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0185","doi-asserted-by":"crossref","first-page":"573","DOI":"10.1148\/rg.332125124","article-title":"Virtual monochromatic spectral imaging with fast kilovoltage switching: reduction of metal artifacts at CT","volume":"33","author":"Pessis","year":"2013","journal-title":"Radiographics"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0190","doi-asserted-by":"crossref","first-page":"173","DOI":"10.1243\/095441103765212677","article-title":"Strain distribution within the human femur due to physiological and simplified loading: finite element analysis using the muscle standardized femur model","volume":"217","author":"Polgar","year":"2003","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0195","series-title":"Oscillation and Reaction Board Techniques for Estimating Inertial Properties of a Below-knee Prosthesis","first-page":"1","author":"Smith","year":"2014"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0200","doi-asserted-by":"crossref","first-page":"1113","DOI":"10.1002\/jor.23352","article-title":"Effect of load on the bone around bone-anchored amputation prostheses","volume":"35","author":"Stenlund","year":"2017","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0205","doi-asserted-by":"crossref","first-page":"114","DOI":"10.1080\/03093640308726667","article-title":"Rehabilitation of the trans-femoral amputee with an osseointegrated prosthesis: the United Kingdom experience","volume":"27","author":"Sullivan","year":"2003","journal-title":"Prosthetics Orthot. Int."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0210","first-page":"1","article-title":"Four decades of finite element analysis of orthopaedic devices: where are we now and what are the opportunities\u202f?","author":"Taylor","year":"2015","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0215","doi-asserted-by":"crossref","first-page":"2418","DOI":"10.1007\/s10439-010-9966-9","article-title":"A comparative finite-element analysis of bone failure and load transfer of osseointegrated prostheses fixations","volume":"38","author":"Tomaszewski","year":"2010","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0220","doi-asserted-by":"crossref","first-page":"1300","DOI":"10.1016\/j.jbiomech.2013.02.010","article-title":"A novel dual fluoroscopic imaging method for determination of THA kinematics: in-vitro and in-vivo study","volume":"46","author":"Tsai","year":"2013","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0225","doi-asserted-by":"crossref","first-page":"1396","DOI":"10.2106\/00004623-198668090-00013","article-title":"A comparative study of porous coatings in a weight-bearing total hip-arthroplasty model","volume":"68","author":"Turner","year":"1986","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0230","doi-asserted-by":"crossref","first-page":"2800","DOI":"10.1007\/s11999-009-0946-z","article-title":"Compress \u00ae periprosthetic fractures: Interface stability and ease of revision","volume":"467","author":"Tyler","year":"2009","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0235","doi-asserted-by":"crossref","first-page":"1781","DOI":"10.1359\/jbmr.2003.18.10.1781","article-title":"Trabecular bone tissue strains in the healthy and osteoporotic human femur","volume":"18","author":"Van Rietbergen","year":"2003","journal-title":"J. Bone Miner. Res."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0240","doi-asserted-by":"crossref","first-page":"168","DOI":"10.1016\/j.ejrad.2018.08.010","article-title":"Metal artifact reduction techniques in musculoskeletal CT-imaging","volume":"107","author":"Wellenberg","year":"2018","journal-title":"Eur. J. Radiol."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0245","doi-asserted-by":"crossref","first-page":"661","DOI":"10.1243\/09544119JEIM84","article-title":"Three-dimensional finite element stress and strain analysis of a transfemoral osseointegration implant","volume":"220","author":"Xu","year":"2006","journal-title":"Proc. Inst. Mech. Eng. Part H J. Eng. Med."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0250","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1016\/j.jbiomech.2015.12.028","article-title":"Numerical evaluation of bone remodelling associated with trans-femoral osseointegration implant\u2013a 68\u00a0month follow-up study","volume":"49","author":"Xu","year":"2016","journal-title":"J. Biomech."},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0255","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/S0966-6362(02)00068-1","article-title":"Biomechanics and muscle coordination of human walking: part I: introduction to concepts, power transfer, dynamics and simulations","volume":"16","author":"Zajac","year":"2002","journal-title":"Gait Posture"},{"key":"10.1016\/j.clinbiomech.2020.01.017_bb0260","doi-asserted-by":"crossref","first-page":"528","DOI":"10.1007\/s11999-015-4552-y","article-title":"Revision distal femoral arthroplasty with the Compress \u00ae prosthesis has a low rate of mechanical failure at 10\u00a0years","volume":"474","author":"Zimel","year":"2016","journal-title":"Clin. Orthop. Relat. Res."}],"container-title":["Clinical Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003319306035?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003319306035?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,2]],"date-time":"2025-10-02T16:49:59Z","timestamp":1759423799000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0268003319306035"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,3]]},"references-count":53,"alternative-id":["S0268003319306035"],"URL":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2020.01.017","relation":{},"ISSN":["0268-0033"],"issn-type":[{"value":"0268-0033","type":"print"}],"subject":[],"published":{"date-parts":[[2020,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Load response of an osseointegrated implant used in the treatment of unilateral transfemoral amputation: An early implant loosening case study","name":"articletitle","label":"Article Title"},{"value":"Clinical Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2020.01.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}