{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,25]],"date-time":"2026-08-25T01:03:06Z","timestamp":1787619786198,"version":"build-2736575974"},"reference-count":17,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,6,24]],"date-time":"2026-06-24T00:00:00Z","timestamp":1782259200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinbiomech.com","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Biomechanics"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.clinbiomech.2026.106905","type":"journal-article","created":{"date-parts":[[2026,6,23]],"date-time":"2026-06-23T23:31:21Z","timestamp":1782257481000},"page":"106905","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Ensuring bone-to-bone contact reduces interfragmentary strain in forearm shaft plating: A finite element study"],"prefix":"10.1016","volume":"138","author":[{"given":"Yusuke","family":"Matsuura","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takahiro","family":"Yamazaki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Aya","family":"Kanazuka","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Seiji","family":"Ohtori","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Takane","family":"Suzuki","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.clinbiomech.2026.106905_bb0005","doi-asserted-by":"crossref","first-page":"287","DOI":"10.2106\/00004623-197557030-00001","article-title":"Compression-plate fixation in acute diaphyseal fractures of the radius and ulna","volume":"57","author":"Anderson","year":"1975","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0010","author":"AO Foundation"},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0015","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/1750-1164-3-5","article-title":"Outcome of diaphyseal forearm fracture-nonunions treated by autologous bone grafting and compression plating","volume":"3","author":"dos Reis","year":"2009","journal-title":"Ann. Surg. Innov. Res."},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0020","series-title":"Bone Repair Biomaterials","first-page":"103","article-title":"Metals","author":"Gonz\u00e1lez-Carrasco","year":"2019"},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0025","first-page":"319","article-title":"Forearm fracture fixation with locking plates: does size matter?","volume":"6","author":"Justice","year":"2024","journal-title":"J. Hand Surg. Glob. Online."},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0030","doi-asserted-by":"crossref","first-page":"781","DOI":"10.1016\/j.otsr.2016.04.014","article-title":"Pre- and postoperative complications of adult forearm fractures treated with plate fixation","volume":"102","author":"Marcheix","year":"2016","journal-title":"Orthop. Traumatol. Surg. Res."},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0035","doi-asserted-by":"crossref","first-page":"1811","DOI":"10.1080\/10255842.2014.974579","article-title":"Accuracy of specimen-specific nonlinear finite element analysis for evaluation of radial diaphysis strength in cadaver material","volume":"18","author":"Matsuura","year":"2015","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0040","first-page":"41","article-title":"New material property conversion equation for bone strength measurement for CT-based finite element modeling","volume":"96E","author":"Matsuyama","year":"2020","journal-title":"Chiba Med. J."},{"issue":"4","key":"10.1016\/j.clinbiomech.2026.106905_bb0045","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1002\/jor.20990","article-title":"Effect of fracture gap on stability of compression plate fixation: a finite element study","volume":"28","author":"Oh","year":"2010","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0050","series-title":"Rockwood and Green\u2019s Fractures in Adults","first-page":"135","article-title":"Basic principles and techniques of internal fixation","author":"Orthopaedic Trauma Association (OTA)","year":"2020"},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0055","first-page":"1","article-title":"The concept of biological plating using the limited contact\u2013dynamic compression plate (LC-DCP): scientific background, design and application","volume":"22","author":"Perren","year":"1991","journal-title":"Injury"},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0060","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/j.hcl.2007.02.005","article-title":"Malunions and nonunions of the forearm","volume":"23","author":"Richard","year":"2007","journal-title":"Hand Clin."},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0065","doi-asserted-by":"crossref","first-page":"362","DOI":"10.1016\/j.injury.2011.11.006","article-title":"The increasing incidence of paediatric diaphyseal both-bone forearm fractures and their internal fixation during the last decade","volume":"43","author":"Sinikumpu","year":"2012","journal-title":"Injury"},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0070","doi-asserted-by":"crossref","DOI":"10.1016\/j.bone.2019.115212","article-title":"Biomechanics of callus in the bone healing process, determined by specimen-specific finite element analysis","volume":"132","author":"Suzuki","year":"2020","journal-title":"Bone"},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0075","doi-asserted-by":"crossref","first-page":"10","DOI":"10.1186\/s10195-025-00823-4","article-title":"Higher nonunion rates with locking plates compared to dynamic compression plates in forearm diaphyseal fractures: a multicenter study","volume":"26","author":"Tseng","year":"2025","journal-title":"J. Orthop. Traumatol."},{"key":"10.1016\/j.clinbiomech.2026.106905_bb0080","article-title":"Adverse events after surgical treatment of adult diaphyseal forearm fractures: a retrospective analysis of 470 patients","volume":"8","author":"Vasara","year":"2023","journal-title":"JB JS Open Access"},{"issue":"5","key":"10.1016\/j.clinbiomech.2026.106905_bb0085","doi-asserted-by":"crossref","first-page":"1123","DOI":"10.1002\/jor.25759","article-title":"Finite element modeling of fracture compression by compression plates","volume":"42","author":"Wee","year":"2024","journal-title":"J. Orthop. Res."}],"container-title":["Clinical Biomechanics"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003326001609?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0268003326001609?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,7,14]],"date-time":"2026-07-14T14:44:30Z","timestamp":1784040270000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0268003326001609"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":17,"alternative-id":["S0268003326001609"],"URL":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2026.106905","relation":{},"ISSN":["0268-0033"],"issn-type":[{"value":"0268-0033","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Ensuring bone-to-bone contact reduces interfragmentary strain in forearm shaft plating: A finite element study","name":"articletitle","label":"Article Title"},{"value":"Clinical Biomechanics","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clinbiomech.2026.106905","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"106905"}}