{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,11,3]],"date-time":"2025-11-03T09:11:51Z","timestamp":1762161111205},"reference-count":42,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2014,7,1]],"date-time":"2014-07-01T00:00:00Z","timestamp":1404172800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clineu-journal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Neurology and Neurosurgery"],"published-print":{"date-parts":[[2014,7]]},"DOI":"10.1016\/j.clineuro.2014.04.013","type":"journal-article","created":{"date-parts":[[2014,4,22]],"date-time":"2014-04-22T07:32:57Z","timestamp":1398151977000},"page":"34-41","update-policy":"http:\/\/dx.doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":10,"special_numbering":"C","title":["Occlusion of canine aneurysms using microporous self-expanding stent grafts: Long-term follow-up"],"prefix":"10.1016","volume":"122","author":[{"given":"Shogo","family":"Nishi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yasuhide","family":"Nakayama","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Hatsue","family":"Ishibashi-Ueda","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Yoshida","family":"Masato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.clineuro.2014.04.013_bib0005","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1055\/s-0030-1268479","article-title":"Retrograde suction decompression assisted clipping of large and giant cerebral aneurysms: our experience","volume":"54","author":"Chen","year":"2011","journal-title":"Minim Invasive Neurosurg"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0010","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1016\/j.clineuro.2012.01.039","article-title":"Large and giant ventral paraclinoid carotid aneurysms; surgical techniques, complications and outcomes","volume":"114","author":"Li","year":"2012","journal-title":"Clin Neurol Neurosurg"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0015","first-page":"107","article-title":"Strategy for the treatment of large-giant aneurysms in the cavernous portion of the internal carotid artery","volume":"41","author":"Ohtaki","year":"2013","journal-title":"No Shinkei Geka"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0020","doi-asserted-by":"crossref","first-page":"E1008","DOI":"10.1227\/01.NEU.0000339119.92564.29","article-title":"Large distal anterior cerebral artery aneurysm treated with resection and interposition graft; case report","volume":"64","author":"Gelfenbeyn","year":"2009","journal-title":"Neurosurgery"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0025","doi-asserted-by":"crossref","first-page":"841","DOI":"10.1179\/1743132811Y.0000000012","article-title":"Complications and adverse events associated with Neuroform stent-assisted coiling of wide-neck intracranial aneurysms","volume":"33","author":"Gao","year":"2011","journal-title":"Neurol Res"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0030","doi-asserted-by":"crossref","first-page":"e224875","DOI":"10.1371\/journal.pone.0024875","article-title":"Comparison of devices used for stent-assisted coiling of intracranial aneurysms","volume":"6","author":"Izar","year":"2011","journal-title":"PLoS One"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0035","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1007\/s00234-009-0502-2","article-title":"Endovascular occlusion of intracranial wide-necked aneurysms with stenting (Neuroform) and coiling: mid-term and long-term results","volume":"51","author":"Sedat","year":"2009","journal-title":"Neuroradiology"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0040","doi-asserted-by":"crossref","first-page":"159","DOI":"10.3174\/ajnr.A2719","article-title":"Stent-supported aneurysm coiling: a literature survey of treatment and follow-up","author":"Shapiro","year":"2012","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0045","doi-asserted-by":"crossref","first-page":"1347","DOI":"10.1227\/01.NEU.0000159887.03290.D1","article-title":"Treatment of experimentally induced aneurysms with stents","volume":"56","author":"Krings","year":"2005","journal-title":"Neurosurgery"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0050","doi-asserted-by":"crossref","first-page":"819","DOI":"10.1007\/s00234-007-0257-6","article-title":"Endovascular treatment of giant or very large intracranial aneurysms with different modalities: analysis of 20 cases","volume":"49","author":"Li","year":"2007","journal-title":"Neuroradiology"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0055","doi-asserted-by":"crossref","first-page":"1115","DOI":"10.1227\/01.neu.0000325873.44881.6e","article-title":"Definitive reconstruction of circumferential fusiform intracranial aneurysms with the pipeline embolization device","volume":"62","author":"Fiorella","year":"2008","journal-title":"Neurosurgery"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0060","doi-asserted-by":"crossref","first-page":"632","DOI":"10.1227\/01.NEU.0000339109.98070.65","article-title":"Curative endovascular reconstruction of cerebral aneurysms with the Pipeline embolization device: the Buenos Aires experience","volume":"64","author":"Lylyk","year":"2009","journal-title":"Neurosurgery"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0065","doi-asserted-by":"crossref","first-page":"1436","DOI":"10.3174\/ajnr.A3246","article-title":"Treatment of intracranial aneurysms using the Pipeline flow diverter embolization device: a single-center experience with long-term follow-up results","author":"Saatci","year":"2012","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0070","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1007\/s10143-012-0404-3","article-title":"Successful endovascular management of brain aneurysms presenting with mass effect and cranial palsy","author":"Hassan","year":"2013","journal-title":"Neurosurg Rev"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0075","doi-asserted-by":"crossref","first-page":"597","DOI":"10.4103\/0028-3886.105193","article-title":"Endovascular management of giant intracranial aneurysms of the posterior circulation","volume":"60","author":"Limaye","year":"2012","journal-title":"Neurol India"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0080","first-page":"739","article-title":"Occlusion of experimentally created fusiform aneurysms with porous metallic stents","author":"Geremia","year":"2000","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0085","doi-asserted-by":"crossref","first-page":"911","DOI":"10.1227\/01.NEU.0000232841.08876.DA","article-title":"Long-term histological and scanning electron microscopy results of endovascular and operative treatments of experimentally induced aneurysms in the rabbit","volume":"59","author":"Krings","year":"2006","journal-title":"Neurosurgery"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0090","doi-asserted-by":"crossref","first-page":"961","DOI":"10.1148\/radiology.174.3.174-3-961","article-title":"Morphologic observation late after coronary balloon angioplasty: mechanisms of acute injury and relationship to restenosis","volume":"174","author":"Waller","year":"1990","journal-title":"Radiology"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0095","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1007\/s10047-011-0581-9","article-title":"Development of microporous self-expanding stent graft grafts for treating cerebral aneurysms: designing micropores to control intimal hyperplasia","author":"Nishi","year":"2011","journal-title":"J Artif Organs"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0100","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1007\/s10047-008-0437-0","article-title":"High performance self-expanding stent graft; development and application to experimental aneurysms","author":"Nishi","year":"2009","journal-title":"J Artif Organs"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0105","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.1227\/01.NEU.0000093427.89827.12","article-title":"Occlusion of experimental aneurysms with heparin-loaded, microporous stent grafts","volume":"53","author":"Nishi","year":"2003","journal-title":"Neurosurgery"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0110","doi-asserted-by":"crossref","first-page":"348","DOI":"10.1161\/01.RES.70.2.348","article-title":"Genetically engineered endothelial cells remain adherent and viable after stent deployment and exposure to flow in vitro","volume":"70","author":"Flugelman","year":"1992","journal-title":"Circ Res"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0115","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1177\/15910199000060S127","article-title":"A new stent graft with thin walled controlled micropored polymer covering","volume":"6","author":"Nishi","year":"2000","journal-title":"Intervent Neuroradiol"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0120","doi-asserted-by":"crossref","first-page":"191","DOI":"10.1016\/S0022-5223(19)35354-1","article-title":"In vivo evaluations of a new thrombo-resistant polyurethane for artificial heart blood pumps","volume":"95","author":"Farrar","year":"1988","journal-title":"J Thorac Cardiovasc Surg"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0125","first-page":"237","article-title":"Gastrointestinal artery stamp hemorrhage following pylorus-sparing whipple procedure: treatment with covered stents","author":"Giancario","year":"2002","journal-title":"Dig Surg"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0130","first-page":"472","article-title":"Biomaterials in the development and future of vascular grafts","author":"Hue","year":"2003","journal-title":"J Vasc Surg"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0135","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1021\/bi00296a014","article-title":"Selective inhibition of thrombin by (2R, 4R)-4-methyl-1-(N2-(3-methyl-1,2,3,4-tetra-hydro-8quinolinyl) sulfonyl)-1-arginyl)) -2-piperidinecarboxylic acid","author":"Kikumoto","year":"1984","journal-title":"Biochemistry"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0140","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1016\/0049-3848(81)90002-5","article-title":"Comparative study on heparin and a synthetic thrombin inhibitor no. 805 (MD-805*) in experimental antithrombin 3-deficient animals","author":"Kumada","year":"1981","journal-title":"Thromb Res"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0145","doi-asserted-by":"crossref","first-page":"256","DOI":"10.1253\/jcj.61.256","article-title":"Effects of locally administration of argatroban using a hydrogel-coated balloon catheter on intimal thickening induced by balloon injury","volume":"61","author":"Imanishi","year":"1997","journal-title":"Jpn Circ J"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0150","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1016\/S0142-9612(99)00281-1","article-title":"Surface modification of polyurethane balloon catheters for local drug delivery","author":"Richey","year":"2000","journal-title":"Biomaterials"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0155","doi-asserted-by":"crossref","first-page":"1267","DOI":"10.1016\/S0140-6736(02)11314-6","article-title":"International Subarachnoid Aneurysm Trial (ISAT) Collaborative Group International Subarachnoid Trial (ISAT) of neurosurgical clipping versus endovascular coiling in 2143 patients with ruptured intracranial aneurysms; a randomized trial","volume":"360","author":"Molyneux","year":"2002","journal-title":"Lancet"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0160","doi-asserted-by":"crossref","first-page":"793","DOI":"10.1097\/00006123-199910000-00013","article-title":"Clinical and angiographic results of endovascular coiling treatment of giant and very large intracranial aneurysms: a 7-year, single-center experience","volume":"45","author":"Gruber","year":"1999","journal-title":"Neurosurgery"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0165","doi-asserted-by":"crossref","first-page":"51","DOI":"10.1227\/01.NEU.0000194190.45595.9E","article-title":"Durability of aneurysm embolization with matrix detachable coils","volume":"58","author":"Fiorella","year":"2006","journal-title":"Neurosurgery"},{"issue":"1","key":"10.1016\/j.clineuro.2014.04.013_bib0170","doi-asserted-by":"crossref","first-page":"12","DOI":"10.1016\/j.clineuro.2011.07.017","article-title":"Comparison of coil types in aneurysm recurrence","volume":"114","author":"Khan","year":"2012","journal-title":"Clin Neurol Neurosurg"},{"issue":"August","key":"10.1016\/j.clineuro.2014.04.013_bib0175","first-page":"334","article-title":"Coiling of large and giant aneurysms; complications and long-term results of 334 cases","author":"Chalouhi","year":"2013","journal-title":"AJNR Am J Neuroraiol"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0180","doi-asserted-by":"crossref","first-page":"176","DOI":"10.3171\/jns.1997.87.2.0176","article-title":"Intracranial aneurysms treated with Guglielmi detachable coils: midterm clinical results in a consecutive series of 100 patients","volume":"87","author":"Malisch","year":"1997","journal-title":"J Neurosurg"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0185","doi-asserted-by":"crossref","first-page":"1354","DOI":"10.1227\/01.NEU.0000333800.51962.66","article-title":"Endovascular treatment of distally located giant aneurysms","volume":"62","author":"Ross","year":"2008","journal-title":"Neurosurgery"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0190","first-page":"1814","article-title":"Stent-within-stent technique for the treatment of dissecting vertebral artery aneurysm","volume":"24","author":"Mehta","year":"2003","journal-title":"AJNR Am J Neuroradiol"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0195","doi-asserted-by":"crossref","first-page":"701","DOI":"10.1056\/NEJM198703193161201","article-title":"Intravascular stents to prevent occlusion and restenosis after transluminal angioplasty","volume":"316","author":"Sigwart","year":"1987","journal-title":"N Engl J Med"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0200","doi-asserted-by":"crossref","first-page":"91","DOI":"10.1148\/radiology.175.1.2315508","article-title":"Flexible tantalum stents implanted in aortas and iliac arteries; effects in normal canines","volume":"175","author":"Barth","year":"1990","journal-title":"Radiology"},{"key":"10.1016\/j.clineuro.2014.04.013_bib0205","doi-asserted-by":"crossref","first-page":"390","DOI":"10.1227\/NEU.0b013e31828046a6","article-title":"In-stent stenosis following stent-assisted coiling: incidence, predictors and clinical outcomes of 435 cases","volume":"72","author":"Chalouhi","year":"2013","journal-title":"Neurosurgery"},{"issue":"January","key":"10.1016\/j.clineuro.2014.04.013_bib0210","article-title":"Treatment of rabbit carotid aneurysms by hybrid stents (microporous thin polyurethane-covered stents): preservation of side-branches","author":"Nishi","year":"2014","journal-title":"J Biomater Appl"}],"container-title":["Clinical Neurology and Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0303846714001413?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0303846714001413?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2020,8,18]],"date-time":"2020-08-18T05:25:43Z","timestamp":1597728343000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0303846714001413"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2014,7]]},"references-count":42,"alternative-id":["S0303846714001413"],"URL":"https:\/\/doi.org\/10.1016\/j.clineuro.2014.04.013","relation":{},"ISSN":["0303-8467"],"issn-type":[{"value":"0303-8467","type":"print"}],"subject":[],"published":{"date-parts":[[2014,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Occlusion of canine aneurysms using microporous self-expanding stent grafts: Long-term follow-up","name":"articletitle","label":"Article Title"},{"value":"Clinical Neurology and Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clineuro.2014.04.013","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2014 Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}