{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,10]],"date-time":"2026-11-10T16:38:05Z","timestamp":1794328685925,"version":"4.9.0"},"reference-count":20,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,12,9]],"date-time":"2024-12-09T00:00:00Z","timestamp":1733702400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.es","clinicalkey.com.au","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Neurology and Neurosurgery"],"published-print":{"date-parts":[[2025,2]]},"DOI":"10.1016\/j.clineuro.2024.108685","type":"journal-article","created":{"date-parts":[[2024,12,9]],"date-time":"2024-12-09T16:26:56Z","timestamp":1733761616000},"page":"108685","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"special_numbering":"C","title":["Robot-assisted anterior odontoid screw for the treatment of type \u2161 odontoid fractures: Safety and effectiveness analysis"],"prefix":"10.1016","volume":"249","author":[{"given":"Liang","family":"Wang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Bin","family":"Xia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-8538-8794","authenticated-orcid":false,"given":"Bo","family":"Yang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"8","key":"10.1016\/j.clineuro.2024.108685_bib1","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1097\/BSD.0000000000000872","article-title":"Odontoid fractures: a critical review of current management and future directions","volume":"32","author":"Carvalho","year":"2019","journal-title":"Clin. Spine Surg."},{"issue":"44","key":"10.1016\/j.clineuro.2024.108685_bib2","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000010281","article-title":"Surgery vs conservative treatment for type II and III odontoid fractures in a geriatric population: a meta-analysis","volume":"98","author":"Fan","year":"2019","journal-title":"Medicine"},{"issue":"3","key":"10.1016\/j.clineuro.2024.108685_bib3","doi-asserted-by":"crossref","first-page":"603","DOI":"10.14245\/ns.2040362.181","article-title":"Outcomes of patients undergoing anterior screw fixation for odontoid fracture and analysis of the predictive factors for surgical failure","volume":"17","author":"Lee","year":"2020","journal-title":"Neurospine"},{"issue":"1","key":"10.1016\/j.clineuro.2024.108685_bib4","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.nec.2019.08.012","article-title":"Robotic-assisted spinal surgery: current generation instrumentation and new applications","volume":"31","author":"Elswick","year":"2020","journal-title":"Neurosurg. Clin. N. Am."},{"key":"10.1016\/j.clineuro.2024.108685_bib5","doi-asserted-by":"crossref","DOI":"10.1302\/0301-620X.102B5.BJJ-2019-1392.R2","article-title":"Surgeon proficiency in robot-assisted spine surgery","author":"McDonnell","year":"2020","journal-title":"Bone Jt. J."},{"issue":"19","key":"10.1016\/j.clineuro.2024.108685_bib6","doi-asserted-by":"crossref","first-page":"B2","DOI":"10.1097\/BRS.0000000000001674","article-title":"Robot-assisted posterior C1-2 transarticular screw fixation for atlantoaxial instability: a case report","volume":"41","author":"Tian","year":"2016","journal-title":"Spine"},{"issue":"1","key":"10.1016\/j.clineuro.2024.108685_bib7","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1007\/s00586-020-06641-y","article-title":"Radiological and clinical differences between robotic-assisted pedicle screw fixation with and without real-time optical tracking","volume":"30","author":"Du","year":"2021","journal-title":"Eur. Spine J.: Off. Publ. Eur. Spine Soc.\u00a0Eur. Spinal Deform. Soc.\u00a0Eur. Sect. Cerv. Spine Res. Soc."},{"issue":"21","key":"10.1016\/j.clineuro.2024.108685_bib8","doi-asserted-by":"crossref","first-page":"2527","DOI":"10.4103\/0366-6999.217080","article-title":"Percutaneous sacroiliac screw placement: a prospective randomized comparison of robot-assisted navigation procedures with a conventional technique","volume":"130","author":"Wang","year":"2017","journal-title":"Chin. Med. J."},{"issue":"3","key":"10.1016\/j.clineuro.2024.108685_bib9","article-title":"The development and error analysis of a kinematic parameters based spatial positioning method for an orthopedic navigation robot system","volume":"13","author":"Pei","year":"2017","journal-title":"Int. J. Med. Robot. + Comput. Assist. Surg.: MRCAS"},{"issue":"2","key":"10.1016\/j.clineuro.2024.108685_bib10","doi-asserted-by":"crossref","first-page":"475","DOI":"10.1007\/s00586-020-06501-9","article-title":"The impact of odontoid screw fixation techniques on screw-related complications and fusion rates: a systematic review and meta-analysis","volume":"30","author":"Lvov","year":"2021","journal-title":"Eur. Spine J.: Off. Publ. Eur. Spine Soc.\u00a0Eur. Spinal Deform. Soc.\u00a0Eur. Sect. Cerv. Spine Res. Soc."},{"issue":"7","key":"10.1016\/j.clineuro.2024.108685_bib11","doi-asserted-by":"crossref","first-page":"2021","DOI":"10.1007\/s11999-012-2389-1","article-title":"One-screw fixation provides similar stability to that of two-screw fixation for type II dens fractures","volume":"470","author":"Feng","year":"2012","journal-title":"Clin. Orthop. Relat. Res."},{"issue":"1","key":"10.1016\/j.clineuro.2024.108685_bib12","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1186\/s13018-017-0702-0","article-title":"The comparison of clinical outcome of fresh type II odontoid fracture treatment between anterior cannulated screws fixation and posterior instrumentation of C1\u20132 without fusion: a retrospective cohort study","volume":"13","author":"Yuan","year":"2018","journal-title":"J. Orthop. Surg. Res."},{"issue":"2","key":"10.1016\/j.clineuro.2024.108685_bib13","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1111\/os.12453","article-title":"Guideline for thoracolumbar pedicle screw placement assisted by orthopaedic surgical robot","volume":"11","author":"Tian","year":"2019","journal-title":"Orthop. Surg."},{"issue":"13","key":"10.1016\/j.clineuro.2024.108685_bib14","doi-asserted-by":"crossref","first-page":"824","DOI":"10.21037\/atm-20-1106","article-title":"Accuracy of robot-assisted versus conventional freehand pedicle screw placement in spine surgery: a systematic review and meta-analysis of randomized controlled trials","volume":"8","author":"Peng","year":"2020","journal-title":"Ann. Transl. Med."},{"issue":"22","key":"10.1016\/j.clineuro.2024.108685_bib15","doi-asserted-by":"crossref","DOI":"10.1097\/MD.0000000000010970","article-title":"Accuracy of pedicle screw placement comparing robot-assisted technology and the free-hand with fluoroscopy-guided method in spine surgery: an updated meta-analysis","volume":"97","author":"Fan","year":"2018","journal-title":"Medicine"},{"issue":"5","key":"10.1016\/j.clineuro.2024.108685_bib16","doi-asserted-by":"crossref","DOI":"10.3171\/2017.3.FOCUS179","article-title":"Accuracy of robot-guided versus freehand fluoroscopy-assisted pedicle screw insertion in thoracolumbar spinal surgery","volume":"42","author":"Molliqaj","year":"2017","journal-title":"Neurosurg. Focus"},{"issue":"8","key":"10.1016\/j.clineuro.2024.108685_bib17","doi-asserted-by":"crossref","first-page":"1397","DOI":"10.1016\/j.spinee.2019.04.003","article-title":"Evaluation of surgeon and patient radiation exposure by imaging technology in patients undergoing thoracolumbar fusion: systematic review of the literature","volume":"19","author":"Pennington","year":"2019","journal-title":"Spine J.: Off. J. N. Am. Spine Soc."},{"issue":"1","key":"10.1016\/j.clineuro.2024.108685_bib18","doi-asserted-by":"crossref","DOI":"10.3171\/2020.10.FOCUS20792","article-title":"Video-assisted thoracoscopic image-guided spine surgery: evolution of 19 years of experience, from endoscopy to fully integrated 3D navigation","volume":"50","author":"Hanna","year":"2021","journal-title":"Neurosurg. Focus"},{"issue":"5","key":"10.1016\/j.clineuro.2024.108685_bib19","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1007\/s00198-020-05277-4","article-title":"Incidental bilateral calcaneal fractures following overground walking with a wearable robotic exoskeleton in a wheelchair user with a chronic spinal cord injury: is zero risk possible?","volume":"31","author":"Bass","year":"2020","journal-title":"Osteoporos. Int.: A J. Establ. Result Coop. Eur. Found. Osteoporos. Natl. Osteoporos. Found. USA"},{"key":"10.1016\/j.clineuro.2024.108685_bib20","doi-asserted-by":"crossref","first-page":"159","DOI":"10.1016\/j.wneu.2020.08.224","article-title":"Technologic evolution of navigation and robotics in spine surgery: a historical perspective","volume":"145","author":"Mao","year":"2021","journal-title":"World Neurosurg."}],"container-title":["Clinical Neurology and Neurosurgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0303846724005729?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0303846724005729?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,2,22]],"date-time":"2025-02-22T00:12:09Z","timestamp":1740183129000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0303846724005729"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":20,"alternative-id":["S0303846724005729"],"URL":"https:\/\/doi.org\/10.1016\/j.clineuro.2024.108685","relation":{},"ISSN":["0303-8467"],"issn-type":[{"value":"0303-8467","type":"print"}],"subject":[],"published":{"date-parts":[[2025,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Robot-assisted anterior odontoid screw for the treatment of type \u2161 odontoid fractures: Safety and effectiveness analysis","name":"articletitle","label":"Article Title"},{"value":"Clinical Neurology and Neurosurgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clineuro.2024.108685","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"108685"}}