{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,1,16]],"date-time":"2026-01-16T02:51:17Z","timestamp":1768531877026,"version":"3.49.0"},"reference-count":32,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2020,6,1]],"date-time":"2020-06-01T00:00:00Z","timestamp":1590969600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2020,6,1]],"date-time":"2020-06-01T00:00:00Z","timestamp":1590969600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"funder":[{"DOI":"10.13039\/501100003725","name":"National Research Foundation of Korea","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100003725","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalimaging.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Imaging"],"published-print":{"date-parts":[[2020,6]]},"DOI":"10.1016\/j.clinimag.2020.01.017","type":"journal-article","created":{"date-parts":[[2020,1,18]],"date-time":"2020-01-18T11:25:41Z","timestamp":1579346741000},"page":"41-48","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":17,"special_numbering":"C","title":["Comparison of image quality and focal lesion detection in abdominopelvic CT: Potential dose reduction using advanced modelled iterative reconstruction"],"prefix":"10.1016","volume":"62","author":[{"given":"Seung Joon","family":"Choi","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"So Hyun","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Young Sup","family":"Shim","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jung Han","family":"Hwang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Suyoung","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seong Yong","family":"Pak","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Myung-Won","family":"You","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Seong Ho","family":"Park","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.clinimag.2020.01.017_bb0005","first-page":"7","article-title":"Cancer statistics, 2018","volume":"68","author":"Siegel","year":"2018","journal-title":"CA Cancer J Clin"},{"issue":"22","key":"10.1016\/j.clinimag.2020.01.017_bb0010","doi-asserted-by":"crossref","first-page":"2277","DOI":"10.1056\/NEJMra072149","article-title":"Computed tomography\u2014an increasing source of radiation exposure","volume":"357","author":"Brenner","year":"2007","journal-title":"N Engl J Med"},{"issue":"1","key":"10.1016\/j.clinimag.2020.01.017_bb0015","doi-asserted-by":"crossref","first-page":"27","DOI":"10.1016\/j.rcl.2008.10.006","article-title":"Strategies for reducing radiation dose in CT","volume":"47","author":"McCollough","year":"2009","journal-title":"Radiol Clin North Am"},{"key":"10.1016\/j.clinimag.2020.01.017_bb0020","doi-asserted-by":"crossref","first-page":"68","DOI":"10.1016\/j.ejrad.2018.12.018","article-title":"Clinical application of radiation dose reduction at abdominal CT","volume":"111","author":"Higaki","year":"2019","journal-title":"Eur J Radiol"},{"issue":"4","key":"10.1016\/j.clinimag.2020.01.017_bb0025","doi-asserted-by":"crossref","first-page":"384","DOI":"10.2214\/AJR.14.13241","article-title":"CT radiation dose and iterative reconstruction techniques","volume":"204","author":"Padole","year":"2015","journal-title":"AJR Am J Roentgenol"},{"issue":"11","key":"10.1016\/j.clinimag.2020.01.017_bb0030","doi-asserted-by":"crossref","first-page":"4526","DOI":"10.1118\/1.2789499","article-title":"A three-dimensional statistical approach to improved image quality for multislice helical CT","volume":"34","author":"Thibault","year":"2007","journal-title":"Med Phys"},{"issue":"12","key":"10.1016\/j.clinimag.2020.01.017_bb0035","doi-asserted-by":"crossref","first-page":"63","DOI":"10.1088\/0031-9155\/58\/12\/R63","article-title":"Modelling the physics in the iterative reconstruction for transmission computed tomography","volume":"58","author":"Nuyts","year":"2013","journal-title":"Phys Med Biol"},{"issue":"3","key":"10.1016\/j.clinimag.2020.01.017_bb0040","doi-asserted-by":"crossref","first-page":"735","DOI":"10.1148\/radiol.15142005","article-title":"Diagnostic performance of an advanced modeled iterative reconstruction algorithm for low-contrast detectability with a third-generation dual-source multidetector CT scanner: potential for radiation dose reduction in a multireader study","volume":"275","author":"Solomon","year":"2015","journal-title":"Radiology"},{"issue":"6","key":"10.1016\/j.clinimag.2020.01.017_bb0045","doi-asserted-by":"crossref","first-page":"2464","DOI":"10.1007\/s00330-017-5113-4","article-title":"Assessment of image quality in abdominal CT: potential dose reduction with model-based iterative reconstruction","volume":"28","author":"Kataria","year":"2018","journal-title":"Eur Radiol"},{"issue":"8","key":"10.1016\/j.clinimag.2020.01.017_bb0050","doi-asserted-by":"crossref","first-page":"946","DOI":"10.1177\/0284185118809544","article-title":"Comparison of standard-dose and half-dose dual-source abdominopelvic CT scans for evaluation of acute abdominal pain","volume":"60","author":"Lee","year":"2019","journal-title":"Acta Radiol"},{"issue":"1","key":"10.1016\/j.clinimag.2020.01.017_bb0055","doi-asserted-by":"crossref","first-page":"50","DOI":"10.2214\/AJR.11.6582","article-title":"A prospective comparison of standard-dose CT enterography and 50% reduced-dose CT enterography with and without noise reduction for evaluating Crohn disease","volume":"197","author":"Lee","year":"2011","journal-title":"AJR Am J Roentgenol"},{"issue":"4","key":"10.1016\/j.clinimag.2020.01.017_bb0060","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1097\/RLI.0000000000000017","article-title":"Image comparative assessment using iterative reconstructions: clinical comparison of low-dose abdominal\/pelvic computed tomography between adaptive statistical, model-based iterative reconstructions and traditional filtered back projection in 65 patients","volume":"49","author":"Vardhanabhuti","year":"2014","journal-title":"Invest Radiol"},{"issue":"1","key":"10.1016\/j.clinimag.2020.01.017_bb0065","doi-asserted-by":"crossref","first-page":"2","DOI":"10.1016\/j.ejrad.2014.09.022","article-title":"Ultra-low dose abdominal MDCT: using a knowledge-based Iterative Model Reconstruction technique for substantial dose reduction in a prospective clinical study","volume":"84","author":"Khawaja","year":"2015","journal-title":"Eur J Radiol"},{"issue":"10","key":"10.1016\/j.clinimag.2020.01.017_bb0070","doi-asserted-by":"crossref","first-page":"1225","DOI":"10.1177\/0284185117752551","article-title":"Evaluation of an iterative model-based CT reconstruction algorithm by intra-patient comparison of standard and ultra-low-dose examinations","volume":"59","author":"Noel","year":"2018","journal-title":"Acta Radiol"},{"issue":"8","key":"10.1016\/j.clinimag.2020.01.017_bb0075","doi-asserted-by":"crossref","first-page":"3300","DOI":"10.1007\/s00330-016-4712-9","article-title":"Emergency assessment of patients with acute abdominal pain using low-dose CT with iterative reconstruction: a comparative study","volume":"27","author":"Poletti","year":"2017","journal-title":"Eur Radiol"},{"issue":"6","key":"10.1016\/j.clinimag.2020.01.017_bb0080","doi-asserted-by":"crossref","first-page":"1266","DOI":"10.2214\/AJR.12.9382","article-title":"Abdominal CT with model-based iterative reconstruction (MBIR): initial results of a prospective trial comparing ultralow-dose with standard-dose imaging","volume":"199","author":"Pickhardt","year":"2012","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"10.1016\/j.clinimag.2020.01.017_bb0085","doi-asserted-by":"crossref","first-page":"469","DOI":"10.1148\/radiol.13130002","article-title":"Model-based iterative reconstruction and adaptive statistical iterative reconstruction techniques in abdominal CT: comparison of image quality in the detection of colorectal liver metastases","volume":"269","author":"Volders","year":"2013","journal-title":"Radiology"},{"issue":"9","key":"10.1016\/j.clinimag.2020.01.017_bb0090","doi-asserted-by":"crossref","first-page":"2279","DOI":"10.1007\/s00261-017-1140-5","article-title":"Reduced dose CT with model-based iterative reconstruction compared to standard dose CT of the chest, abdomen, and pelvis in oncology patients: intra-individual comparison study on image quality and lesion conspicuity","volume":"42","author":"Morimoto","year":"2017","journal-title":"Abdom Radiol (NY)"},{"issue":"1021","key":"10.1016\/j.clinimag.2020.01.017_bb0095","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20120224","article-title":"Dose reduction in oncological staging multidetector CT: effect of iterative reconstruction","volume":"86","author":"Karpitschka","year":"2013","journal-title":"Br J Radiol"},{"issue":"4","key":"10.1016\/j.clinimag.2020.01.017_bb0100","doi-asserted-by":"crossref","first-page":"2107","DOI":"10.1007\/s00330-018-5750-2","article-title":"Prospective evaluation of ultra-low-dose contrast-enhanced 100-kV abdominal computed tomography with tin filter: effect on radiation dose reduction and image quality with a third-generation dual-source CT system","volume":"29","author":"Leyendecker","year":"2019","journal-title":"Eur Radiol"},{"issue":"4","key":"10.1016\/j.clinimag.2020.01.017_bb0105","doi-asserted-by":"crossref","first-page":"285","DOI":"10.3348\/jksr.2016.75.4.285","article-title":"100 kVp low-tube voltage abdominal CT in adults: radiation dose reduction and image quality comparison of 120 kVp abdominal CT","volume":"75","author":"Ha","year":"2016","journal-title":"J Korean Soc Radiol"},{"key":"10.1016\/j.clinimag.2020.01.017_bb0110","series-title":"European guidelines on quality criteria for computed tomography","author":"Leonardi","year":"1999"},{"key":"10.1016\/j.clinimag.2020.01.017_bb0115","first-page":"1","article-title":"The 2007 recommendations of the international commission on radiological protection: ICRP Publication 103","volume":"37","author":"International Commission on Radiation Protection","year":"2007","journal-title":"Ann ICRP"},{"issue":"1","key":"10.1016\/j.clinimag.2020.01.017_bb0120","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3348\/kjr.2012.13.1.1","article-title":"CT radiation dose optimization and estimation: an update for radiologists","volume":"13","author":"Goo","year":"2012","journal-title":"Korean J Radiol"},{"key":"10.1016\/j.clinimag.2020.01.017_bb0125","doi-asserted-by":"crossref","unstructured":"AAPM Task Group 204. Size specific dose estimates in pediatric and adult body CT examinations. College Park, MD: American Association of Physicists in Medicine, 2011. Available from: https:\/\/www.aapm.org\/pubs\/reports\/RPT_204.pdf. doi:https:\/\/doi.org\/10.1118\/1.4725756. [accessed 15 June 2019]","DOI":"10.1118\/1.4725756"},{"issue":"2","key":"10.1016\/j.clinimag.2020.01.017_bb0130","doi-asserted-by":"crossref","first-page":"303","DOI":"10.1148\/radiol.2282011860","article-title":"Measurement of observer agreement","volume":"228","author":"Kundel","year":"2003","journal-title":"Radiology"},{"issue":"6","key":"10.1016\/j.clinimag.2020.01.017_bb0135","doi-asserted-by":"crossref","first-page":"543","DOI":"10.1016\/0895-4356(90)90158-L","article-title":"High agreement but low kappa. I. The problems of two paradoxes","volume":"43","author":"Feinstein","year":"1990","journal-title":"J Clin Epidemiol"},{"issue":"4","key":"10.1016\/j.clinimag.2020.01.017_bb0140","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1097\/RCT.0000000000000231","article-title":"Assessment of filtered back projection, adaptive statistical, and model-based iterative reconstruction for reduced dose abdominal computed tomography","volume":"39","author":"Padole","year":"2015","journal-title":"J Comput Assist Tomogr"},{"issue":"1","key":"10.1016\/j.clinimag.2020.01.017_bb0145","doi-asserted-by":"crossref","first-page":"99","DOI":"10.1016\/j.clinimag.2014.10.013","article-title":"Feasibility of ultra-low radiation dose reduction for renal stone CT using model-based iterative reconstruction: prospective pilot study","volume":"39","author":"Scott Kriegshauser","year":"2015","journal-title":"Clin Imaging"},{"issue":"1","key":"10.1016\/j.clinimag.2020.01.017_bb0150","doi-asserted-by":"crossref","first-page":"193","DOI":"10.1148\/radiol.11102452","article-title":"Impact of reduced patient life expectancy on potential cancer risks from radiologic imaging","volume":"261","author":"Brenner","year":"2011","journal-title":"Radiology"},{"issue":"1","key":"10.1016\/j.clinimag.2020.01.017_bb0155","doi-asserted-by":"crossref","first-page":"197","DOI":"10.1148\/radiol.12112707","article-title":"Filtered back projection, adaptive statistical iterative reconstruction, and a model-based iterative reconstruction in abdominal CT: an experimental clinical study","volume":"266","author":"Deak","year":"2013","journal-title":"Radiology"},{"key":"10.1016\/j.clinimag.2020.01.017_bb0205","article-title":"Comparison of submillisievert CT with standard-dose CT for urolithiasis","author":"Shim","year":"2019","journal-title":"Acta Radiologica"}],"container-title":["Clinical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0899707120300309?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0899707120300309?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T11:41:39Z","timestamp":1760269299000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0899707120300309"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2020,6]]},"references-count":32,"alternative-id":["S0899707120300309"],"URL":"https:\/\/doi.org\/10.1016\/j.clinimag.2020.01.017","relation":{},"ISSN":["0899-7071"],"issn-type":[{"value":"0899-7071","type":"print"}],"subject":[],"published":{"date-parts":[[2020,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparison of image quality and focal lesion detection in abdominopelvic CT: Potential dose reduction using advanced modelled iterative reconstruction","name":"articletitle","label":"Article Title"},{"value":"Clinical Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clinimag.2020.01.017","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}