{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T04:50:41Z","timestamp":1773809441069,"version":"3.50.1"},"reference-count":14,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2021,7,1]],"date-time":"2021-07-01T00:00:00Z","timestamp":1625097600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2021,7,1]],"date-time":"2021-07-01T00:00:00Z","timestamp":1625097600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalimaging.org","clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Imaging"],"published-print":{"date-parts":[[2021,7]]},"DOI":"10.1016\/j.clinimag.2020.12.011","type":"journal-article","created":{"date-parts":[[2020,12,26]],"date-time":"2020-12-26T11:05:21Z","timestamp":1608980721000},"page":"22-26","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":24,"special_numbering":"C","title":["Effects of iron oxide particles on MRI and mammography in breast cancer patients after a sentinel lymph node biopsy with paramagnetic tracers"],"prefix":"10.1016","volume":"75","author":[{"given":"Erkin","family":"Aribal","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Levent","family":"\u00c7elik","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cem","family":"Yilmaz","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Cem","family":"Demirkiran","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Davut Can","family":"Guner","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"2","key":"10.1016\/j.clinimag.2020.12.011_bb0005","doi-asserted-by":"crossref","first-page":"175","DOI":"10.1016\/j.breast.2014.01.004","article-title":"The central-European SentiMag study: sentinel lymph node biopsy with superparamagnetic iron oxide (SPIO) vs. radioisotope","volume":"23","author":"Thill","year":"2014","journal-title":"Breast"},{"issue":"4","key":"10.1016\/j.clinimag.2020.12.011_bb0010","doi-asserted-by":"crossref","first-page":"1237","DOI":"10.1245\/s10434-013-3379-6","article-title":"Sentinel node biopsy using a magnetic tracer versus standard technique: the SentiMAG multicentre trial","volume":"21","author":"Douek","year":"2014","journal-title":"Ann Surg Oncol"},{"issue":"4","key":"10.1016\/j.clinimag.2020.12.011_bb0015","article-title":"The superparamagnetic iron oxide tracer: a valid alternative in sentinel node biopsy for breast cancer treatment","volume":"26","author":"Ghilli","year":"2017","journal-title":"Eur J Cancer Care (Engl)"},{"key":"10.1016\/j.clinimag.2020.12.011_bb0020","doi-asserted-by":"crossref","unstructured":"Ersoy YE, Kadioglu H. Review of novel sentinel lymph node biopsy techniques in breast cancer patients treated with Neoadjuvant chemotherapy. Clin Breast Cancer. 2018 Aug;18(4):e555-e559. doi: https:\/\/doi.org\/10.1016\/j.clbc.2018.01.004. Epub 2018 Jan 31. PMID: 29429940.","DOI":"10.1016\/j.clbc.2018.01.004"},{"issue":"1","key":"10.1016\/j.clinimag.2020.12.011_bb0025","doi-asserted-by":"crossref","first-page":"46","DOI":"10.1016\/j.ejso.2014.11.006","article-title":"The superparamagnetic iron oxide is equivalent to the Tc99 radiotracer method for identifying the sentinel lymph node in breast cancer","volume":"41","author":"Rubio","year":"2015","journal-title":"Eur J Surg Oncol"},{"key":"10.1016\/j.clinimag.2020.12.011_bb0030","doi-asserted-by":"crossref","unstructured":"Pi\u00f1ero-Madrona A, Torr\u00f3-Richart JA, de Le\u00f3n-Carrillo JM, et al (2015). Pi\u00f1ero-Madrona A, Torr\u00f3-Richart JA, de Le\u00f3n-Carrillo JM, et al. Superparamagnetic iron oxide as a tracer for sentinel node biopsy in breast cancer: a comparative non-inferiority study. Eur J Surg Oncol. 2015;41(8):991\u2013997. doi:https:\/\/doi.org\/10.1016\/j.ejso.2015.04.017.","DOI":"10.1016\/j.ejso.2015.04.017"},{"key":"10.1016\/j.clinimag.2020.12.011_bb0035","doi-asserted-by":"crossref","unstructured":"Arslan G, Y\u0131lmaz C, \u00c7elik L, \u00c7ubuk R, Tasal\u0131 N. Unexpected finding on mammography and MRI due to accumulation of iron oxide particles used for sentinel lymph node detection. Eur J Breast Health. 2019;15(3):200\u2013202. Published 2019 Jul 1. doi:https:\/\/doi.org\/10.5152\/ejbh.2019.4410.","DOI":"10.5152\/ejbh.2019.4410"},{"issue":"5","key":"10.1016\/j.clinimag.2020.12.011_bb0040","doi-asserted-by":"crossref","first-page":"731","DOI":"10.1016\/j.ejso.2018.01.241","article-title":"Optimisation of breast MRI compatibility after sentinel node biopsy with paramagnetic tracers","volume":"44","author":"Karakatsanis","year":"2018","journal-title":"Eur J Surg Oncol"},{"issue":"1","key":"10.1016\/j.clinimag.2020.12.011_bb0045","doi-asserted-by":"crossref","first-page":"74","DOI":"10.1016\/j.ejso.2017.11.016","article-title":"Feasibility of breast MRI after sentinel procedure for breast cancer with superparamagnetic tracers","volume":"44","author":"Krischer","year":"2018","journal-title":"Eur J Surg Oncol"},{"key":"10.1016\/j.clinimag.2020.12.011_bb0050","doi-asserted-by":"crossref","unstructured":"Harvey JA, Hendrick RE, Coll JM, Nicholson BT, Burkholder BT, Cohen MA. Breast MR imaging artifacts: how to recognize and fix them. Radiographics. 2007;27 Suppl 1:S131-S145. doi:https:\/\/doi.org\/10.1148\/rg.27si075514.","DOI":"10.1148\/rg.27si075514"},{"issue":"3","key":"10.1016\/j.clinimag.2020.12.011_bb0055","doi-asserted-by":"crossref","first-page":"547","DOI":"10.2214\/AJR.11.7364","article-title":"Metal-induced artifacts in MRI","volume":"197","author":"Hargreaves","year":"2011","journal-title":"AJR Am J Roentgenol"},{"issue":"2","key":"10.1016\/j.clinimag.2020.12.011_bb0060","doi-asserted-by":"crossref","first-page":"372","DOI":"10.2214\/AJR.05.1254","article-title":"Effects on breast MRI of artifacts caused by metallic tissue marker clips","volume":"188","author":"Genson","year":"2007","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.clinimag.2020.12.011_bb0065","doi-asserted-by":"crossref","unstructured":"Singh DR, Chin MS, Peh WC. Artifacts in musculoskeletal MR imaging. Semin Musculoskelet Radiol. 2014;18(1):12\u201322. doi:https:\/\/doi.org\/10.1055\/s-0034-1365831.","DOI":"10.1055\/s-0034-1365831"},{"key":"10.1016\/j.clinimag.2020.12.011_bb0070","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1016\/j.ejro.2019.05.006","article-title":"Improvement in breast magnetic resonance imaging after a sentinel procedure for breast cancer with superparamagnetic tracers","volume":"6","author":"Forte","year":"2019","journal-title":"Eur J Radiol Open"}],"container-title":["Clinical Imaging"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0899707120305179?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0899707120305179?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,12]],"date-time":"2025-10-12T11:44:17Z","timestamp":1760269457000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0899707120305179"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2021,7]]},"references-count":14,"alternative-id":["S0899707120305179"],"URL":"https:\/\/doi.org\/10.1016\/j.clinimag.2020.12.011","relation":{},"ISSN":["0899-7071"],"issn-type":[{"value":"0899-7071","type":"print"}],"subject":[],"published":{"date-parts":[[2021,7]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Effects of iron oxide particles on MRI and mammography in breast cancer patients after a sentinel lymph node biopsy with paramagnetic tracers","name":"articletitle","label":"Article Title"},{"value":"Clinical Imaging","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clinimag.2020.12.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2020 Elsevier Inc. All rights reserved.","name":"copyright","label":"Copyright"}]}}