{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,25]],"date-time":"2025-10-25T13:56:23Z","timestamp":1761400583095,"version":"build-2065373602"},"reference-count":22,"publisher":"Elsevier BV","issue":"9","license":[{"start":{"date-parts":[[2010,9,1]],"date-time":"2010-09-01T00:00:00Z","timestamp":1283299200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2010,9,1]],"date-time":"2010-09-01T00:00:00Z","timestamp":1283299200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Neurophysiology"],"published-print":{"date-parts":[[2010,9]]},"DOI":"10.1016\/j.clinph.2010.03.028","type":"journal-article","created":{"date-parts":[[2010,4,28]],"date-time":"2010-04-28T09:22:02Z","timestamp":1272446522000},"page":"1574-1583","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":4,"title":["Application of a novel automatic duration method measurement based on the wavelet transform on pathological motor unit action potentials"],"prefix":"10.1016","volume":"121","author":[{"given":"Ignacio","family":"Rodr\u00edguez-Carre\u00f1o","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Luis","family":"Gila-Useros","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Armando","family":"Malanda-Trigueros","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"I.G.","family":"Gurtubay","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Javier","family":"Navallas-Irujo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Javier","family":"Rodr\u00edguez-Falces","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.clinph.2010.03.028_bib1","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1002\/mus.880170803","article-title":"Reference values of motor unit action potentials obtained with multi-MUAP analysis","volume":"17","author":"Bischoff","year":"1994","journal-title":"Muscle Nerve"},{"key":"10.1016\/j.clinph.2010.03.028_bib2","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1002\/1097-4598(200007)23:7<1022::AID-MUS4>3.0.CO;2-3","article-title":"Quantification of jiggle in real electromyographic signals","volume":"23","author":"Campos","year":"2000","journal-title":"Muscle Nerve"},{"key":"10.1016\/j.clinph.2010.03.028_bib4","first-page":"387","article-title":"Skill and selection bias has least influence on motor unit action potential firing rate\/frequency","volume":"43","author":"Chu","year":"2003","journal-title":"Electromyogr Clin Neurophysiol"},{"key":"10.1016\/j.clinph.2010.03.028_bib5","doi-asserted-by":"crossref","first-page":"1188","DOI":"10.1002\/(SICI)1097-4598(199909)22:9<1188::AID-MUS4>3.0.CO;2-I","article-title":"Motor unit action potential duration and muscle length","volume":"22","author":"Dumitru","year":"1999","journal-title":"Muscle Nerve"},{"key":"10.1016\/j.clinph.2010.03.028_bib6","doi-asserted-by":"crossref","first-page":"1876","DOI":"10.1016\/S1388-2457(99)00142-X","article-title":"Determinants of motor unit action potential duration","volume":"110","author":"Dumitru","year":"1999","journal-title":"Clin Neurophysiol"},{"key":"10.1016\/j.clinph.2010.03.028_bib7","doi-asserted-by":"crossref","first-page":"832","DOI":"10.1109\/TBME.2005.863893","article-title":"Automatic decomposition of intramuscular electromyographic signals","volume":"53","author":"Florestal","year":"2006","journal-title":"IEEE Trans Biomed Eng"},{"key":"10.1016\/j.clinph.2010.03.028_bib8","doi-asserted-by":"crossref","first-page":"462","DOI":"10.1016\/S0924-980X(98)00048-4","article-title":"The physiological origin of the slow afterwave in muscle action potentials","volume":"109","author":"Lateva","year":"1998","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"10.1016\/j.clinph.2010.03.028_bib9","unstructured":"Malanda A, Navallas J, Gila L, Rodr\u00edguez J, Rodr\u00edguez I. Extraction of representative potentials in MUAP sets. In: Proceedings of the XVIIth congress of the international society of electrophysiology and kinesiology; 2008. p. 54."},{"key":"10.1016\/j.clinph.2010.03.028_bib12","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1016\/0013-4694(88)90168-X","article-title":"Analysis of the amplitude and area of the concentric needle EMG motor unit action potentials","volume":"69","author":"Nandedkar","year":"1988","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"10.1016\/j.clinph.2010.03.028_bib13","doi-asserted-by":"crossref","first-page":"1155","DOI":"10.1002\/mus.880181012","article-title":"Multi motor unit action potential analysis (MMA)","volume":"18","author":"Nandedkar","year":"1995","journal-title":"Muscle Nerve"},{"key":"10.1016\/j.clinph.2010.03.028_bib14","unstructured":"Navallas J, Malanda A, Gila L, Rodr\u00edguez J, Rodr\u00edguez I, Florestal JR, et al. An algorithm for optimal discharge selection for MUAP waveform extraction. In: Proceedings of the XVIth congress of the international society of electrophysiology and kinesiology; 2006. p. 12."},{"year":"1996","series-title":"Digital signal processing: principles, algorithms and applications","author":"Proakis","key":"10.1016\/j.clinph.2010.03.028_bib15"},{"key":"10.1016\/j.clinph.2010.03.028_bib16","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1016\/j.cmpb.2005.11.002","article-title":"Filter design for cancellation of baseline-fluctuation in needle EMG recordings","volume":"81","author":"Rodr\u00edguez","year":"2006","journal-title":"Comput Methods Programs Biomed"},{"key":"10.1016\/j.clinph.2010.03.028_bib17","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1097\/01.wnp.0000236606.53923.0d","article-title":"Motor unit action potential duration: I. Variability of manual and automatic measurements","volume":"24","author":"Rodr\u00edguez","year":"2007","journal-title":"J Clin Neurophysiol"},{"key":"10.1016\/j.clinph.2010.03.028_bib18","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1097\/01.wnp.0000236581.49422.c3","article-title":"Motor unit action potential duration: II. A new automatic measurement method based on the wavelet transform","volume":"24","author":"Rodr\u00edguez","year":"2007","journal-title":"J Clin Neurophysiol"},{"issue":"Suppl. 11","key":"10.1016\/j.clinph.2010.03.028_bib19","doi-asserted-by":"crossref","first-page":"S98","DOI":"10.1002\/mus.10154","article-title":"New attempts to quantify concentric needle electromyography","author":"Sonoo","year":"2002","journal-title":"Muscle Nerve"},{"key":"10.1016\/j.clinph.2010.03.028_bib20","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1016\/0168-5597(93)90068-Z","article-title":"The ability of MUP parameters to discriminate between normal and neurogenic MUPs in concentric EMG: analysis of the MUP \u201cthickness\u201d and the proposal of \u201csize index\u201d","volume":"89","author":"Sonoo","year":"1993","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"10.1016\/j.clinph.2010.03.028_bib21","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1097\/00004691-198610000-00003","article-title":"Quantitative analysis of individual motor unit potentials \u2013 a proposition for standardized terminology and criteria for measurement","volume":"3","author":"Stalberg","year":"1986","journal-title":"J Clin Neurophysiol"},{"key":"10.1016\/j.clinph.2010.03.028_bib22","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1016\/0924-980X(95)00007-8","article-title":"Multi-MUP EMG analysis \u2013 a two year experience with a quantitative method in daily routine","volume":"97","author":"Stalberg","year":"1995","journal-title":"Electroencephalogr Clin Neurophysiol"},{"key":"10.1016\/j.clinph.2010.03.028_bib23","doi-asserted-by":"crossref","first-page":"401","DOI":"10.1097\/00004691-199609000-00004","article-title":"Quantitative motor unit potential analysis","volume":"13","author":"Stalberg","year":"1996","journal-title":"J Clin Neurophysiol"},{"key":"10.1016\/j.clinph.2010.03.028_bib25","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1002\/mus.20046","article-title":"Reliability of quantitative motor unit action potential parameters","volume":"30","author":"Takehara","year":"2004","journal-title":"Muscle Nerve"},{"key":"10.1016\/j.clinph.2010.03.028_bib26","first-page":"265","article-title":"Motor unit action potential (MUAP) parameters affected by editing duration cursors","volume":"44","author":"Takehara","year":"2004","journal-title":"Electromyogr Clin Neurophysiol"}],"container-title":["Clinical Neurophysiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1388245710003160?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S1388245710003160?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,25]],"date-time":"2025-10-25T10:56:45Z","timestamp":1761389805000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S1388245710003160"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2010,9]]},"references-count":22,"journal-issue":{"issue":"9","published-print":{"date-parts":[[2010,9]]}},"alternative-id":["S1388245710003160"],"URL":"https:\/\/doi.org\/10.1016\/j.clinph.2010.03.028","relation":{},"ISSN":["1388-2457"],"issn-type":[{"type":"print","value":"1388-2457"}],"subject":[],"published":{"date-parts":[[2010,9]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Application of a novel automatic duration method measurement based on the wavelet transform on pathological motor unit action potentials","name":"articletitle","label":"Article Title"},{"value":"Clinical Neurophysiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clinph.2010.03.028","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2010 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.","name":"copyright","label":"Copyright"}]}}