{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T23:04:05Z","timestamp":1789513445081,"version":"build-2803163510"},"reference-count":37,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","clinicaloncologyonline.net","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Oncology"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.clon.2026.104216","type":"journal-article","created":{"date-parts":[[2026,6,12]],"date-time":"2026-06-12T00:09:34Z","timestamp":1781222974000},"page":"104216","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Exploring the Need for Plan Adaptation in Robustly Optimised Head and Neck Intensity Modulated Proton Therapy: A Dosimetric Perspective From Initial Institutional Experience"],"prefix":"10.1016","volume":"56","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-9549-4231","authenticated-orcid":false,"given":"V.","family":"Raveendran","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-3369-3870","authenticated-orcid":false,"given":"S.","family":"Sinha","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"P.","family":"Mukherjee","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Kumar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-1619-841X","authenticated-orcid":false,"given":"P.H.","family":"Shinde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0002-7351-2085","authenticated-orcid":false,"given":"A.C.","family":"Prabu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0007-7488-0804","authenticated-orcid":false,"given":"R.N.","family":"Punde","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.N.","family":"Chaudhari","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0001-0818-4743","authenticated-orcid":false,"given":"S.M.","family":"Mathew","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.","family":"Mohanty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Swain","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.","family":"Budrukkar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0744-4838","authenticated-orcid":false,"given":"S.G.","family":"Laskar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.clon.2026.104216_bib1","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1016\/S0140-6736(25)01962-2","article-title":"Proton versus photon radiotherapy for patients with oropharyngeal cancer in the USA: a multicentre, randomised, open-label, non-inferiority phase 3 trial","volume":"407","author":"Frank","year":"2026","journal-title":"Lancet"},{"key":"10.1016\/j.clon.2026.104216_bib2","doi-asserted-by":"crossref","DOI":"10.1016\/j.radonc.2023.109971","article-title":"Comparing the oncologic outcomes of proton therapy and intensity-modulated radiation therapy for head and neck squamous cell carcinoma","volume":"190","author":"Chang","year":"2024","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib3","doi-asserted-by":"crossref","first-page":"960","DOI":"10.1016\/j.ijrobp.2003.12.024","article-title":"Quantification of volumetric and geometric changes occurring during fractionated radiotherapy for head-and-neck cancer using an integrated CT\/linear accelerator system","volume":"59","author":"Barker","year":"2004","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.clon.2026.104216_bib4","article-title":"Dosimetric impact of adaptive proton therapy in head and neck cancer\u2013a review","volume":"39","author":"Huiskes","year":"2023","journal-title":"Clin Transl Radiat Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib5","doi-asserted-by":"crossref","first-page":"22TR01","DOI":"10.1088\/1361-6560\/ac344f","article-title":"Adaptive proton therapy","volume":"66","author":"Paganetti","year":"2021","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.clon.2026.104216_bib6","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1088\/0031-9155\/53\/4\/015","article-title":"Intensity modulated proton therapy and its sensitivity to treatment uncertainties 2: the potential effects of inter-fraction and inter-field motions","volume":"53","author":"Lomax","year":"2008","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.clon.2026.104216_bib7","doi-asserted-by":"crossref","first-page":"59","DOI":"10.1088\/1361-6560\/62\/1\/59","article-title":"Water equivalent path length calculations using scatter-corrected head and neck CBCT images to evaluate patients for adaptive proton therapy","volume":"62","author":"Kim","year":"2016","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.clon.2026.104216_bib8","doi-asserted-by":"crossref","first-page":"888","DOI":"10.1016\/j.ijrobp.2013.09.014","article-title":"Dose uncertainties in IMPT for oropharyngeal cancer in the presence of anatomical, range, and setup errors","volume":"87","author":"Kraan","year":"2013","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.clon.2026.104216_bib9","doi-asserted-by":"crossref","first-page":"187","DOI":"10.1016\/j.radonc.2007.11.032","article-title":"Sensitivity of intensity modulated proton therapy plans to changes in patient weight","volume":"86","author":"Albertini","year":"2008","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib10","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.radonc.2014.08.024","article-title":"Dose distribution resulting from changes in aeration of nasal cavity or paranasal sinus cancer in the proton therapy","volume":"113","author":"Fukumitsu","year":"2014","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib11","doi-asserted-by":"crossref","first-page":"394","DOI":"10.14338\/IJPT-15-00002.1","article-title":"The impact of anatomic change on pencil beam scanning in the treatment of oropharynx cancer","volume":"2","author":"Thomson","year":"2015","journal-title":"Int J Part Ther"},{"key":"10.1016\/j.clon.2026.104216_bib12","doi-asserted-by":"crossref","first-page":"616","DOI":"10.1016\/j.ijrobp.2016.11.013","article-title":"Effect of anatomic changes on pencil beam scanned proton dose distributions for cranial and extracranial tumors","volume":"97","author":"Placidi","year":"2017","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.clon.2026.104216_bib13","doi-asserted-by":"crossref","first-page":"22TR02","DOI":"10.1088\/1361-6560\/aae659","article-title":"Robust radiotherapy planning","volume":"63","author":"Unkelbach","year":"2018","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.clon.2026.104216_bib14","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1118\/1.3021139","article-title":"Reducing the sensitivity of IMPT treatment plans to setup errors and range uncertainties via probabilistic treatment planning","volume":"36","author":"Unkelbach","year":"2009","journal-title":"Med Phys"},{"key":"10.1016\/j.clon.2026.104216_bib15","doi-asserted-by":"crossref","first-page":"1079","DOI":"10.1118\/1.3679340","article-title":"Robust optimization of intensity modulated proton therapy","volume":"39","author":"Liu","year":"2012","journal-title":"Med Phys"},{"key":"10.1016\/j.clon.2026.104216_bib16","series-title":"Adaptive proton therapy utilizing an in-room CT","author":"Lomax","year":"2020"},{"key":"10.1016\/j.clon.2026.104216_bib17","doi-asserted-by":"crossref","first-page":"127","DOI":"10.1016\/j.radonc.2018.12.008","article-title":"Including anatomical variations in robust optimization for head and neck proton therapy can reduce the need of adaptation","volume":"131","author":"Cubillos-Mes\u00edas","year":"2019","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib18","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/aa9c1c","article-title":"Anatomical robust optimization to account for nasal cavity filling variation during intensity-modulated proton therapy: a comparison with conventional and adaptive planning strategies","volume":"63","author":"van de Water","year":"2018","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.clon.2026.104216_bib19","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.radonc.2017.09.032","article-title":"Multiple-CT optimization of intensity-modulated proton therapy\u2013Is it possible to eliminate adaptive planning?","volume":"128","author":"Wang","year":"2018","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib20","doi-asserted-by":"crossref","first-page":"124","DOI":"10.1016\/j.radonc.2019.09.010","article-title":"Multiple-CT optimization: An adaptive optimization method to account for anatomical changes in intensity-modulated proton therapy for head and neck cancers","volume":"142","author":"Yang","year":"2020","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib21","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/abe050","article-title":"Comparison of weekly and daily online adaptation for head and neck intensity-modulated proton therapy","volume":"66","author":"Bobi\u0107","year":"2021","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.clon.2026.104216_bib22","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ad7cbd","article-title":"First clinical implementation of a highly efficient daily online adapted proton therapy (DAPT) workflow","volume":"69","author":"Albertini","year":"2024","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.clon.2026.104216_bib23","series-title":"Model policy: proton beam therapy","year":"2023"},{"key":"10.1016\/j.clon.2026.104216_bib24","doi-asserted-by":"crossref","first-page":"84","DOI":"10.14338\/IJPT-20-00071.1","article-title":"PTCOG head and neck subcommittee consensus guidelines on particle therapy for the management of head and neck tumors","volume":"8","author":"Lin","year":"2021","journal-title":"Int J Part Ther"},{"key":"10.1016\/j.clon.2026.104216_bib25","doi-asserted-by":"crossref","DOI":"10.1016\/j.radonc.2025.111135","article-title":"Delineation of the post-operative primary tumour and nodal clinical target volumes in oral cavity squamous cell carcinoma: European Society for Radiotherapy and Oncology (ESTRO) clinical guidelines","volume":"212","author":"Evans","year":"2025","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib26","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/j.radonc.2017.10.016","volume":"126","author":"Gr\u00e9goire","year":"2018","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib27","doi-asserted-by":"crossref","first-page":"S3","DOI":"10.1016\/j.ijrobp.2009.09.040","article-title":"Quantitative Analyses of Normal Tissue Effects in the Clinic (QUANTEC): an introduction to the scientific issues","volume":"76","author":"Bentzen","year":"2010","journal-title":"Int J Radiat Oncol Biol Phys"},{"key":"10.1016\/j.clon.2026.104216_bib28","doi-asserted-by":"crossref","first-page":"e236","DOI":"10.1002\/mp.14030","article-title":"Strategies for effective physics plan and chart review in radiation therapy: report of AAPM Task Group 275","volume":"47","author":"Ford","year":"2020","journal-title":"Med Phys"},{"key":"10.1016\/j.clon.2026.104216_bib29","doi-asserted-by":"crossref","first-page":"6794","DOI":"10.1002\/mp.15915","article-title":"Use of CBCT plus plan robustness for reducing QACT frequency in intensity-modulated proton therapy: head-and-neck cases","volume":"49","author":"Yao","year":"2022","journal-title":"Med Phys"},{"key":"10.1016\/j.clon.2026.104216_bib30","doi-asserted-by":"crossref","DOI":"10.1002\/acm2.13550","article-title":"Onboard cone-beam CT-based replan evaluation for head and neck proton therapy","volume":"23","author":"Stanforth","year":"2022","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.clon.2026.104216_bib31","doi-asserted-by":"crossref","first-page":"26","DOI":"10.14338\/IJPT-17-00010.1","article-title":"Intensity-modulated proton therapy adaptive planning for patients with oropharyngeal cancer","volume":"4","author":"Wu","year":"2017","journal-title":"Int J Part Ther"},{"key":"10.1016\/j.clon.2026.104216_bib32","doi-asserted-by":"crossref","first-page":"174","DOI":"10.1002\/acm2.13128","article-title":"Potential benefits of adaptive intensity-modulated proton therapy in nasopharyngeal carcinomas","volume":"22","author":"Minatogawa","year":"2021","journal-title":"J Appl Clin Med Phys"},{"key":"10.1016\/j.clon.2026.104216_bib33","doi-asserted-by":"crossref","first-page":"384","DOI":"10.1016\/j.meddos.2020.06.002","article-title":"Evaluation of replanning in intensity-modulated proton therapy for oropharyngeal cancer: Factors influencing plan robustness","volume":"45","author":"Deiter","year":"2020","journal-title":"Med Dosim"},{"key":"10.1016\/j.clon.2026.104216_bib34","doi-asserted-by":"crossref","first-page":"39","DOI":"10.1016\/j.radonc.2021.03.008","article-title":"Anatomic changes in head and neck intensity-modulated proton therapy: Comparison between robust optimization and online adaptation","volume":"159","author":"Lalonde","year":"2021","journal-title":"Radiother Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib35","doi-asserted-by":"crossref","first-page":"64","DOI":"10.1186\/s13014-016-0641-7","article-title":"Feasibility of automated proton therapy plan adaptation for head and neck tumors using cone beam CT images","volume":"11","author":"Kurz","year":"2016","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib36","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1186\/1748-717X-7-19","article-title":"Assessment of shoulder position variation and its impact on IMRT and VMAT doses for head and neck cancer","volume":"7","author":"Neubauer","year":"2012","journal-title":"Radiat Oncol"},{"key":"10.1016\/j.clon.2026.104216_bib37","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1016\/j.ejmp.2018.08.015","article-title":"Impact of shoulder deformation on volumetric modulated arc therapy doses for head and neck cancer","volume":"53","author":"Tachibana","year":"2018","journal-title":"Phys Med"}],"container-title":["Clinical Oncology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0936655526001871?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0936655526001871?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,15]],"date-time":"2026-09-15T22:41:05Z","timestamp":1789512065000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0936655526001871"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":37,"alternative-id":["S0936655526001871"],"URL":"https:\/\/doi.org\/10.1016\/j.clon.2026.104216","relation":{},"ISSN":["0936-6555"],"issn-type":[{"value":"0936-6555","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Exploring the Need for Plan Adaptation in Robustly Optimised Head and Neck Intensity Modulated Proton Therapy: A Dosimetric Perspective From Initial Institutional Experience","name":"articletitle","label":"Article Title"},{"value":"Clinical Oncology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.clon.2026.104216","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Royal College of Radiologists. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"104216"}}