{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T22:32:22Z","timestamp":1790634742175,"version":"4.1.0"},"reference-count":37,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2016,10,1]],"date-time":"2016-10-01T00:00:00Z","timestamp":1475280000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.fr","clinicalkey.com.au","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Computer Methods and Programs in Biomedicine"],"published-print":{"date-parts":[[2016,10]]},"DOI":"10.1016\/j.cmpb.2016.07.016","type":"journal-article","created":{"date-parts":[[2016,7,12]],"date-time":"2016-07-12T17:38:24Z","timestamp":1468345104000},"page":"187-196","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":65,"special_numbering":"C","title":["Paroxysmal atrial fibrillation prediction method with shorter HRV sequences"],"prefix":"10.1016","volume":"134","author":[{"given":"K.H.","family":"Boon","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Khalil-Hani","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.B.","family":"Malarvili","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.W.","family":"Sia","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.cmpb.2016.07.016_bib0010","doi-asserted-by":"crossref","first-page":"2369","DOI":"10.1093\/eurheartj\/ehq278","article-title":"Guidelines for the management of atrial fibrillation the task force for the management of atrial fibrillation of the European Society of Cardiology (ESC)","volume":"31","author":"Camm","year":"2010","journal-title":"Eur. Heart J."},{"issue":"2","key":"10.1016\/j.cmpb.2016.07.016_bib0015","doi-asserted-by":"crossref","first-page":"239","DOI":"10.1097\/HJH.0b013e32834f03bf","article-title":"Hypertension and atrial fibrillation: diagnostic approach, prevention and treatment. Position paper of the Working Group \u201cHypertension Arrhythmias and Thrombosis\u201d of the European Society of Hypertension","volume":"30","author":"Manolis","year":"2012","journal-title":"J. Hypertens"},{"issue":"1","key":"10.1016\/j.cmpb.2016.07.016_bib0020","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1067\/mhj.2000.107547","article-title":"Observations on the transition from intermittent to permanent atrial fibrillation","volume":"140","author":"Al-Khatib","year":"2000","journal-title":"Am. Heart J."},{"issue":"5","key":"10.1016\/j.cmpb.2016.07.016_bib0025","doi-asserted-by":"crossref","first-page":"1007","DOI":"10.1016\/S0735-1097(97)00043-0","article-title":"Acute effects of dual-site right atrial pacing in patients with spontaneous and inducible atrial flutter and fibrillation","volume":"29","author":"Prakash","year":"1997","journal-title":"J. Am. Coll. Cardiol"},{"issue":"10, Suppl. 1","key":"10.1016\/j.cmpb.2016.07.016_bib0030","doi-asserted-by":"crossref","first-page":"3","DOI":"10.1016\/S0002-9149(00)00908-5","article-title":"Management of atrial fibrillation: therapeutic options and clinical decisions","volume":"85","author":"Prystowsky","year":"2000","journal-title":"Am. J. Cardiol"},{"issue":"5","key":"10.1016\/j.cmpb.2016.07.016_bib0035","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1161\/01.CIR.93.5.1043","article-title":"Heart rate variability: standards of measurement, physiological interpretation, and clinical use","volume":"93","author":"Task Force of the European Society of Cardiology","year":"1996","journal-title":"Circulation"},{"key":"10.1016\/j.cmpb.2016.07.016_bib0040","series-title":"A methodology for predicting paroxysmal atrial fibrillation based on ECG arrhythmia feature analysis","year":"2001"},{"key":"10.1016\/j.cmpb.2016.07.016_bib0045","series-title":"Screening for paroxysmal atrial fibrillation using atrial premature contractions and spectral measures","year":"2002"},{"issue":"4","key":"10.1016\/j.cmpb.2016.07.016_bib0050","doi-asserted-by":"crossref","first-page":"561","DOI":"10.1109\/TBME.2003.821030","article-title":"Prediction of paroxysmal atrial fibrillation by analysis of atrial premature complexes","volume":"51","author":"Tran","year":"2004","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"10.1016\/j.cmpb.2016.07.016_bib0055","series-title":"Atrial fibrillation onset prediction using variability of ECG signals","year":"2013"},{"issue":"1","key":"10.1016\/j.cmpb.2016.07.016_bib0060","doi-asserted-by":"crossref","first-page":"40","DOI":"10.1016\/j.cmpb.2010.07.011","article-title":"Prediction of paroxysmal atrial fibrillation based on non-linear analysis and spectrum and bispectrum features of the heart rate variability signal","volume":"105","author":"Mohebbi","year":"2012","journal-title":"Comput. Methods Programs Biomed"},{"issue":"2","key":"10.1016\/j.cmpb.2016.07.016_bib0065","doi-asserted-by":"crossref","first-page":"151","DOI":"10.1016\/j.artmed.2008.03.009","article-title":"Complexity and spectral analysis of the heart rate variability dynamics for distant prediction of paroxysmal atrial fibrillation with artificial intelligence methods","volume":"43","author":"Chesnokov","year":"2008","journal-title":"Artif. Intell. Med"},{"key":"10.1016\/j.cmpb.2016.07.016_bib0070","series-title":"Prediction of paroxysmal atrial fibrillation by footprint analysis","year":"2001"},{"key":"10.1016\/j.cmpb.2016.07.016_bib0075","series-title":"A two-stage solution algorithm for paroxysmal atrial fibrillation prediction","year":"2001"},{"key":"10.1016\/j.cmpb.2016.07.016_bib0080","series-title":"Design and implementation of biomedical SoC for implantable cardioverter defibrillators","year":"2007"},{"issue":"1","key":"10.1016\/j.cmpb.2016.07.016_bib0085","doi-asserted-by":"crossref","first-page":"19","DOI":"10.1109\/TBCAS.2009.2035555","article-title":"Digital heart-rate variability parameter monitoring and assessment ASIC","volume":"4","author":"Massagram","year":"2010","journal-title":"IEEE Trans. Biomed. Circ. Syst."},{"issue":"5","key":"10.1016\/j.cmpb.2016.07.016_bib0090","doi-asserted-by":"crossref","first-page":"1491","DOI":"10.1016\/j.eswa.2012.08.042","article-title":"Design of heart rate variability processor for portable 3-lead ECG monitoring system-on-chip","volume":"40","author":"Fang","year":"2013","journal-title":"Expert Syst. Appl."},{"issue":"12","key":"10.1016\/j.cmpb.2016.07.016_bib0095","doi-asserted-by":"crossref","first-page":"1031","DOI":"10.1007\/s11517-006-0119-0","article-title":"Heart rate variability: a review","volume":"44","author":"Rajendra Acharya","year":"2006","journal-title":"Med. Biol. Eng. Comput."},{"issue":"23","key":"10.1016\/j.cmpb.2016.07.016_bib0100","doi-asserted-by":"crossref","first-page":"e215","DOI":"10.1161\/01.CIR.101.23.e215","article-title":"PhysioBank, PhysioToolkit, and PhysioNet : components of a new research resource for complex physiologic signals","volume":"101","author":"Goldberger","year":"2000","journal-title":"Circulation"},{"issue":"3","key":"10.1016\/j.cmpb.2016.07.016_bib0105","doi-asserted-by":"crossref","first-page":"230","DOI":"10.1109\/TBME.1985.325532","article-title":"Detection algorithm","volume":"32","author":"Pan","year":"1985","journal-title":"IEEE Trans. Biomed. Eng"},{"issue":"12","key":"10.1016\/j.cmpb.2016.07.016_bib0110","doi-asserted-by":"crossref","first-page":"1157","DOI":"10.1109\/TBME.1986.325695","article-title":"Quantitative investigation of QRS detection rules using the MIT\/BIH arrhythmia database","volume":"33","author":"Hamilton","year":"1986","journal-title":"IEEE Trans. Biomed. Eng"},{"issue":"4","key":"10.1016\/j.cmpb.2016.07.016_bib0115","doi-asserted-by":"crossref","first-page":"630","DOI":"10.1109\/TBME.2005.844028","article-title":"Quantifying errors in spectral estimates of HRV due to beat replacement and resampling","volume":"52","author":"Clifford","year":"2005","journal-title":"IEEE Trans. Biomed. Eng"},{"key":"10.1016\/j.cmpb.2016.07.016_bib0120","series-title":"Impulse rejection filter for artifact removal in spectral analysis of biomedical signals","year":"2004"},{"issue":"2","key":"10.1016\/j.cmpb.2016.07.016_bib0125","doi-asserted-by":"crossref","first-page":"325","DOI":"10.1088\/0967-3334\/23\/2\/308","article-title":"A study on the optimum order of autoregressive models for heart rate variability","volume":"23","author":"Anita","year":"2002","journal-title":"Physiol. Meas"},{"issue":"1","key":"10.1016\/j.cmpb.2016.07.016_bib0130","doi-asserted-by":"crossref","first-page":"35","DOI":"10.1016\/S0165-0270(98)00064-8","article-title":"A comparison of fast Fourier transform (FFT) and autoregressive (AR) spectral estimation techniques for the analysis of tremor data","volume":"83","author":"Spyers-Ashby","year":"1998","journal-title":"J. Neurosci. Methods"},{"issue":"7","key":"10.1016\/j.cmpb.2016.07.016_bib0135","doi-asserted-by":"crossref","first-page":"869","DOI":"10.1109\/PROC.1987.13824","article-title":"Bispectrum estimation: a digital signal processing framework","volume":"75","author":"Nikias","year":"1987","journal-title":"P. IEEE"},{"issue":"10","key":"10.1016\/j.cmpb.2016.07.016_bib0140","doi-asserted-by":"crossref","first-page":"1774","DOI":"10.1109\/TBME.2004.831519","article-title":"Bicoherence analysis of new cardiovascular spectral components observed in heart-transplant patients: statistical approach for bicoherence thresholding","volume":"51","author":"Pinhas","year":"2004","journal-title":"IEEE Trans. Biomed. Eng"},{"issue":"8","key":"10.1016\/j.cmpb.2016.07.016_bib0145","doi-asserted-by":"crossref","first-page":"816","DOI":"10.1016\/j.compbiomed.2012.06.005","article-title":"Bispectral analysis and genetic algorithm for congestive heart failure recognition based on heart rate variability","volume":"42","author":"Yu","year":"2012","journal-title":"Comput. Biol. Med"},{"issue":"6","key":"10.1016\/j.cmpb.2016.07.016_bib0150","doi-asserted-by":"crossref","first-page":"1629","DOI":"10.1016\/j.ins.2007.11.012","article-title":"Classifying mental tasks based on features of higher-order statistics from EEG signals in brain\u2013computer interface","volume":"178","author":"Zhou","year":"2008","journal-title":"Inf. Sci. (Ny)"},{"issue":"1","key":"10.1016\/j.cmpb.2016.07.016_bib0155","doi-asserted-by":"crossref","first-page":"82","DOI":"10.1063\/1.166141","article-title":"Quantification of scaling exponents and crossover phenomena in nonstationary heartbeat time series","volume":"5","author":"Peng","year":"1995","journal-title":"Chaos"},{"issue":"4","key":"10.1016\/j.cmpb.2016.07.016_bib0160","doi-asserted-by":"crossref","first-page":"H1643","DOI":"10.1152\/ajpheart.1994.266.4.H1643","article-title":"Physiological time-series analysis: what does regularity quantify?","volume":"266","author":"Pincus","year":"1994","journal-title":"Am. J. Physiol. Heart Circ. Physiol"},{"issue":"3","key":"10.1016\/j.cmpb.2016.07.016_bib0165","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1145\/1961189.1961199","article-title":"LIBSVM: A library for support vector machines","volume":"2","author":"Chang","year":"2011","journal-title":"ACM Trans. Intell. Syst. Technol"},{"key":"10.1016\/j.cmpb.2016.07.016_bib0170","doi-asserted-by":"crossref","first-page":"72","DOI":"10.1016\/j.compbiomed.2013.11.016","article-title":"Investigating the performance improvement of HRV Indices in CHF using feature selection methods based on backward elimination and statistical significance","volume":"45","author":"Narin","year":"2014","journal-title":"Comput. Biol. Med"},{"issue":"19","key":"10.1016\/j.cmpb.2016.07.016_bib0175","doi-asserted-by":"crossref","first-page":"2507","DOI":"10.1093\/bioinformatics\/btm344","article-title":"A review of feature selection techniques in bioinformatics","volume":"23","author":"Saeys","year":"2007","journal-title":"Bioinformatics"},{"issue":"2","key":"10.1016\/j.cmpb.2016.07.016_bib0180","doi-asserted-by":"crossref","first-page":"231","DOI":"10.1016\/j.eswa.2005.09.024","article-title":"A GA-based feature selection and parameters optimizationfor support vector machines","volume":"31","author":"Huang","year":"2006","journal-title":"Expert Syst. Appl."},{"key":"10.1016\/j.cmpb.2016.07.016_bib0185","first-page":"1089","article-title":"No unbiased estimator of the variance of K-fold cross-validation","volume":"5","author":"Bengio","year":"2004","journal-title":"J. Mach. Learn. Res"},{"key":"10.1016\/j.cmpb.2016.07.016_bib0190","doi-asserted-by":"crossref","first-page":"85","DOI":"10.1016\/j.knosys.2012.10.011","article-title":"A simultaneous feature adaptation and feature selection method for content-based image retrieval systems","volume":"39","author":"Rashedi","year":"2013","journal-title":"Know-Based Syst"}],"container-title":["Computer Methods and Programs in Biomedicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0169260715304235?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0169260715304235?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,10,29]],"date-time":"2019-10-29T00:14:20Z","timestamp":1572308060000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0169260715304235"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2016,10]]},"references-count":37,"alternative-id":["S0169260715304235"],"URL":"https:\/\/doi.org\/10.1016\/j.cmpb.2016.07.016","relation":{},"ISSN":["0169-2607"],"issn-type":[{"value":"0169-2607","type":"print"}],"subject":[],"published":{"date-parts":[[2016,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Paroxysmal atrial fibrillation prediction method with shorter HRV sequences","name":"articletitle","label":"Article Title"},{"value":"Computer Methods and Programs in Biomedicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.cmpb.2016.07.016","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2016 Elsevier Ireland Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}