{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T21:03:50Z","timestamp":1790802230668,"version":"4.1.0"},"reference-count":59,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,12,1]],"date-time":"2026-12-01T00:00:00Z","timestamp":1796083200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T00:00:00Z","timestamp":1789689600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100003196","name":"Governo Italiano Ministero della Salute","doi-asserted-by":"publisher","award":["RF-2021-12375208"],"award-info":[{"award-number":["RF-2021-12375208"]}],"id":[{"id":"10.13039\/501100003196","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Computer Methods and Programs in Biomedicine"],"published-print":{"date-parts":[[2026,12]]},"DOI":"10.1016\/j.cmpb.2026.109652","type":"journal-article","created":{"date-parts":[[2026,9,18]],"date-time":"2026-09-18T23:25:19Z","timestamp":1789773919000},"page":"109652","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["Toward a computationally efficient numerical approach to simulate the left atrial appendage occlusion in patient-specific anatomies"],"prefix":"10.1016","volume":"287","author":[{"ORCID":"https:\/\/orcid.org\/0009-0001-0013-8750","authenticated-orcid":false,"given":"Chiara","family":"Bonfanti","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Francesca","family":"Danielli","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8621-2503","authenticated-orcid":false,"given":"Francesca","family":"Berti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8946-1983","authenticated-orcid":false,"given":"Benigno Marco","family":"Fanni","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-0122-5175","authenticated-orcid":false,"given":"Emanuele","family":"Gasparotti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-7832-0122","authenticated-orcid":false,"given":"Simona","family":"Celi","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Sergio","family":"Berti","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4515-0101","authenticated-orcid":false,"given":"Giancarlo","family":"Pennati","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-6349-1586","authenticated-orcid":false,"given":"Lorenza","family":"Petrini","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.cmpb.2026.109652_bib0001","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1161\/01.RES.72.1.167","article-title":"Altered left atrial compliance after atrial appendectomy: influence on left atrial and ventricular filling","volume":"72","author":"Hoit","year":"1993","journal-title":"Circ. Res."},{"key":"10.1016\/j.cmpb.2026.109652_bib0002","doi-asserted-by":"crossref","first-page":"H559","DOI":"10.1152\/ajpheart.00083.2022","article-title":"Abnormal left atrial body stiffness is predicted by appendage size: impact of appendage occlusion on left atrial mechanics assessed by pressure-volume analysis","volume":"323","author":"Bregasi","year":"2022","journal-title":"Am. J. Physiol. - Hear. Circ. Physiol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0003","unstructured":"N. Mumoli, S. Sanatkhani, Z. Li, Stroke risk evaluation for patients with atrial fibrillation: insights from left atrial appendage, n.d."},{"key":"10.1016\/j.cmpb.2026.109652_bib0004","doi-asserted-by":"crossref","DOI":"10.31083\/j.rcm2407211","article-title":"Percutaneous left atrial appendage occlusion therapy: evolution and growing evidence","volume":"24","author":"Han","year":"2023","journal-title":"Rev. Cardiovasc. Med."},{"key":"10.1016\/j.cmpb.2026.109652_bib0005","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2022.1074562","article-title":"Imaging and biophysical modelling of thrombogenic mechanisms in atrial fibrillation and stroke","volume":"9","author":"Qureshi","year":"2023","journal-title":"Front. Cardiovasc. Med."},{"key":"10.1016\/j.cmpb.2026.109652_bib0006","doi-asserted-by":"crossref","DOI":"10.3390\/jcm12216909","article-title":"The left atrial appendage and atrial fibrillation\u2014a contemporary review","volume":"12","author":"Sulague","year":"2023","journal-title":"J. Clin. Med."},{"key":"10.1016\/j.cmpb.2026.109652_bib0007","unstructured":"J. Gofus, P. Zacek, Y. Shahin, K. Medilek, L. Haman, J. Vojacek, Left atrial appendage occlusion: percutaneous and surgical approaches in everyday practice, (n.d.). https:\/\/doi.org\/10.33963\/v.kp.99369."},{"key":"10.1016\/j.cmpb.2026.109652_bib0008","doi-asserted-by":"crossref","DOI":"10.3390\/jcm12175524","article-title":"Non-pharmacological stroke prevention in atrial fibrillation","volume":"12","author":"Anduaga","year":"2023","journal-title":"J. Clin. Med."},{"key":"10.1016\/j.cmpb.2026.109652_bib0009","doi-asserted-by":"crossref","DOI":"10.31083\/j.rcm2412360","article-title":"Choosing appropriate candidates for left atrial appendage occlusion","volume":"24","author":"Zhang","year":"2023","journal-title":"Rev. Cardiovasc. Med."},{"key":"10.1016\/j.cmpb.2026.109652_bib0010","doi-asserted-by":"crossref","first-page":"E1038","DOI":"10.4244\/EIJ-D-22-00627","article-title":"Left atrial appendage occlusion","volume":"18","author":"Holmes","year":"2023","journal-title":"EuroIntervention"},{"key":"10.1016\/j.cmpb.2026.109652_bib0011","unstructured":"B. Plicht, T.F.M. Konorza, P. Kahlert, F. Al-Rashid, H. Kaelsch, R.A. J\u00e1nosi, T. Buck, H.S. Bachmann, W. Siffert, G. Heusch, R. Erbel, Risk factors for thrombus formation on the amplatzer cardiac plug after left atrial appendage occlusion, n.d."},{"key":"10.1016\/j.cmpb.2026.109652_bib0012","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1016\/j.ijcard.2017.07.052","article-title":"Left atrial appendage closure using AMPLATZER\u2122 devices: a large, multicenter, Italian registry","volume":"248","author":"Berti","year":"2017","journal-title":"Int. J. Cardiol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0013","doi-asserted-by":"crossref","unstructured":"S. Kubo, Y. Mizutani, K. Meemook, Y. Nakajima, A. Hussaini, S. Kar, Incidence, characteristics, and clinical course of device-related thrombus after watchman left atrial appendage occlusion device implantation in atrial fibrillation patients, 2017.","DOI":"10.1016\/j.jacep.2017.05.006"},{"key":"10.1016\/j.cmpb.2026.109652_bib0014","doi-asserted-by":"crossref","unstructured":"A. Sedaghat, J.-W. Schrickel, R. Andri\u00e9, R. Schueler, G. Nickenig, C. Hammerstingl, Thrombus formation after left atrial appendage occlusion with the amplatzer amulet device, 2017.","DOI":"10.1016\/j.jacep.2016.05.006"},{"key":"10.1016\/j.cmpb.2026.109652_bib0015","doi-asserted-by":"crossref","first-page":"1528","DOI":"10.1016\/j.jacc.2018.01.076","article-title":"Device-related thrombosis after percutaneous left atrial appendage occlusion for atrial fibrillation","volume":"71","author":"Fauchier","year":"2018","journal-title":"J. Am. Coll. Cardiol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0016","doi-asserted-by":"crossref","first-page":"1003","DOI":"10.1016\/j.jcin.2019.02.003","article-title":"Incidence, characterization, and clinical impact of device-related thrombus following left atrial appendage occlusion in the prospective global AMPLATZER amulet observational study","volume":"12","author":"Aminian","year":"2019","journal-title":"JACC Cardiovasc. Interv."},{"key":"10.1016\/j.cmpb.2026.109652_bib0017","doi-asserted-by":"crossref","unstructured":"M.A. Ainhoa, L.O. Andy, Y. \u00a8ue Carlos, S. Etelvino, M. Nunez-Garcia, A. Fernandez-Quilez, J. Mill, I. Genua, D. Arzamendi, T. De Potter, X. Freixa, O. Camara, In Silico Optimization of Left Atrial Appendage Occluder Implantation Using Interactive and Modeling Tools., (2019) 10\u2013237.","DOI":"10.3389\/fphys.2019.00237"},{"key":"10.1016\/j.cmpb.2026.109652_bib0018","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2018.00034","article-title":"Computational fluid dynamic analysis of the left atrial appendage to predict thrombosis risk","volume":"5","author":"Bosi","year":"2018","journal-title":"Front. Cardiovasc. Med."},{"key":"10.1016\/j.cmpb.2026.109652_bib0019","doi-asserted-by":"crossref","DOI":"10.3389\/fbioe.2021.586041","article-title":"Effect of the alterations in contractility and morphology produced by atrial fibrillation on the thrombosis potential of the left atrial appendage","volume":"9","author":"Vella","year":"2021","journal-title":"Front. Bioeng. Biotechnol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0020","article-title":"Evaluation of stroke risk in patients with atrial fibrillation using morphological and hemodynamic characteristics","volume":"9","author":"Wang","year":"2022","journal-title":"Front. Cardiovasc. Med."},{"key":"10.1016\/j.cmpb.2026.109652_bib0021","doi-asserted-by":"crossref","first-page":"2348","DOI":"10.3934\/mbe.2020125","article-title":"Numerical prediction of thrombosis risk in left atrium under atrial fibrillation","volume":"17","author":"Wang","year":"2020","journal-title":"Math. Biosci. Eng."},{"key":"10.1016\/j.cmpb.2026.109652_bib0022","first-page":"1","article-title":"Virtual left atrial appendage occlusion in paroxysmal atrial fibrillation during sinus rhythm predicts variable reductions in blood stasis","author":"B\u00e4ck","year":"2025","journal-title":"J. Physiol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0023","doi-asserted-by":"crossref","DOI":"10.1016\/j.compbiomed.2021.104423","article-title":"A comprehensive comparison of various patient-specific CFD models of the left atrium for atrial fibrillation patients","volume":"133","author":"Due\u00f1as-Pamplona","year":"2021","journal-title":"Comput. Biol. Med."},{"key":"10.1016\/j.cmpb.2026.109652_bib0024","doi-asserted-by":"crossref","DOI":"10.3390\/app10041448","article-title":"Correlation between LAA morphological features and computational fluid dynamics analysis for non-valvular atrial fibrillation patients","volume":"10","author":"Fanni","year":"2020","journal-title":"Appl. Sci."},{"key":"10.1016\/j.cmpb.2026.109652_bib0025","doi-asserted-by":"crossref","DOI":"10.1002\/cnm.3100","article-title":"Sensitivity analysis of geometrical parameters to study haemodynamics and thrombus formation in the left atrial appendage","volume":"34","author":"Garc\u00eda-Isla","year":"2018","journal-title":"Int. J. Numer. Meth. Biomed. Eng."},{"key":"10.1016\/j.cmpb.2026.109652_bib0026","doi-asserted-by":"crossref","DOI":"10.3389\/fphys.2021.596596","article-title":"Demonstration of patient-specific simulations to assess left atrial appendage thrombogenesis risk","volume":"12","author":"Garc\u00eda-Villalba","year":"2021","journal-title":"Front. Physiol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0027","doi-asserted-by":"crossref","DOI":"10.1002\/cnm.3597","article-title":"Non-Newtonian blood rheology impacts left atrial stasis in patient-specific simulations","volume":"38","author":"Gonzalo","year":"2022","journal-title":"Int. J. Numer. Meth. Biomed. Eng."},{"key":"10.1016\/j.cmpb.2026.109652_bib0028","doi-asserted-by":"crossref","DOI":"10.1115\/1.4044583","article-title":"A proof of concept for computational fluid dynamic analysis of the left atrium in atrial fibrillation on a patient-specific basis","volume":"142","author":"Masci","year":"2020","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.cmpb.2026.109652_bib0029","doi-asserted-by":"crossref","DOI":"10.3389\/fphys.2018.01938","article-title":"The impact of left atrium appendage morphology on stroke risk assessment in atrial fibrillation: a computational fluid dynamics study","volume":"9","author":"Masci","year":"2019","journal-title":"Front. Physiol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0030","doi-asserted-by":"crossref","first-page":"3284","DOI":"10.1007\/s10439-016-1590-x","article-title":"A computational framework for personalized blood flow analysis in the human left atrium","volume":"44","author":"Otani","year":"2016","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/j.cmpb.2026.109652_bib0031","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pcbi.1011546","article-title":"Impact of occluder device configurations in insilico left atrial hemodynamics for the analysis of device-related thrombus","volume":"20","author":"Albors","year":"2024","journal-title":"PLoS Comput. Biol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0032","doi-asserted-by":"crossref","DOI":"10.3389\/fcvm.2023.1067964","article-title":"Preliminary findings on left atrial appendage occlusion simulations applying different endocardial devices","volume":"10","author":"D\u2019Alessandro","year":"2023","journal-title":"Front. Cardiovasc. Med."},{"key":"10.1016\/j.cmpb.2026.109652_bib0033","doi-asserted-by":"crossref","unstructured":"E. Gasparotti, B.M. Fanni, E. Del Pia, K. Capellini, F. Danielli, F. Berti, A. Clemente, S. Berti, G. Pennati, L. Petrini, Computational Fluid Dynamic Simulation to Evaluate the Device-Related Effects After Left Atrial Appendage Occlusion, Springer. (2023) 205\u2013212.","DOI":"10.1007\/978-3-031-55315-8_23"},{"key":"10.1016\/j.cmpb.2026.109652_bib0034","doi-asserted-by":"crossref","DOI":"10.3390\/math9182304","article-title":"Sensitivity analysis of in silico fluid simulations to predict thrombus formation after left atrial appendage occlusion","volume":"9","author":"Mill","year":"2021","journal-title":"Mathematics"},{"key":"10.1016\/j.cmpb.2026.109652_bib0035","doi-asserted-by":"crossref","unstructured":"E. Planas, J. Mill, A. Olivares, X. Morales, M. Pons, X. Iriart, H. Cochet, O. Camara, In-silico Analysis of Device-Related Thrombosis For Different Left Atrial Appendage Occluder Settings, (2022) 160\u2013168.","DOI":"10.1007\/978-3-030-93722-5_18"},{"key":"10.1016\/j.cmpb.2026.109652_bib0036","first-page":"1405","article-title":"Impact of left atrial appendage occlusion device position on potential determinants of device-related thrombus: a patient-specific in silico study","volume":"113","author":"Zhong","year":"2024","journal-title":"Clin. Res. Cardiol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0037","first-page":"1","article-title":"Blood flow stasis improvements after simulated occlusion of the left atrial appendage in paroxysmal atrial fibrillation using 4-D computed tomography","author":"Hassan","year":"2025","journal-title":"J. Physiol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0038","doi-asserted-by":"crossref","first-page":"149","DOI":"10.1016\/j.jcct.2019.08.010","article-title":"Validation of a computational model aiming to optimize preprocedural planning in percutaneous left atrial appendage closure","volume":"14","author":"Bavo","year":"2020","journal-title":"J. Cardiovasc. Comput. Tomogr."},{"key":"10.1016\/j.cmpb.2026.109652_bib0039","doi-asserted-by":"crossref","DOI":"10.1002\/cnm.3814","article-title":"Left atrial appendage occlusion: on the need of a numerical model to simulate the implant procedure","volume":"40","author":"Danielli","year":"2024","journal-title":"Int. J. Numer. Meth. Biomed. Eng."},{"key":"10.1016\/j.cmpb.2026.109652_bib0040","unstructured":"Feops heartguide, (n.d.)."},{"key":"10.1016\/j.cmpb.2026.109652_bib0041","doi-asserted-by":"crossref","DOI":"10.1016\/j.jacadv.2022.100139","article-title":"Feops heart guide patient-specific computational simulations for WATCHMAN FLX left atrial appendage closure: a retrospective study","volume":"1","author":"Ranard","year":"2022","journal-title":"JACC Adv"},{"key":"10.1016\/j.cmpb.2026.109652_bib0042","first-page":"1356","article-title":"Clinical value of CT-based 3D computational modeling in left atrial appendage occlusion: an in-depth analysis of the PRECISE LAAO study","volume":"105","author":"De Cock","year":"2025","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"10.1016\/j.cmpb.2026.109652_bib0043","first-page":"1290","article-title":"Understanding the role of the left atrial appendage on the flow in the atrium","volume":"104","author":"Bshennaty","year":"2024","journal-title":"Catheter. Cardiovasc. Interv."},{"key":"10.1016\/j.cmpb.2026.109652_bib0044","article-title":"Comparison of flow dynamics after left atrial appendage occlusion with the watchman FLX versus amulet devices: implications for device-related thrombosis","author":"Bshennaty","year":"2025","journal-title":"Catheter. Cardiovasc. Interv"},{"key":"10.1016\/j.cmpb.2026.109652_bib0045","doi-asserted-by":"crossref","DOI":"10.1016\/j.jacadv.2024.101339","article-title":"Flow dynamic factors correlated with device-related thrombosis after left atrial appendage occlusion","volume":"3","author":"Vogl","year":"2024","journal-title":"JACC Adv"},{"key":"10.1016\/j.cmpb.2026.109652_bib0046","doi-asserted-by":"crossref","DOI":"10.1016\/j.compbiomed.2025.110355","article-title":"A new braided model of the Amulet Amplatzer for accurate simulations of left atrial appendage occlusion procedures","volume":"192","author":"Md","year":"2025","journal-title":"Comput. Biol. Med."},{"key":"10.1016\/j.cmpb.2026.109652_bib0047","doi-asserted-by":"crossref","first-page":"104","DOI":"10.1016\/j.medengphy.2020.05.019","article-title":"Left atrial appendage occlusion device: development and validation of a finite element model","volume":"82","author":"Zaccaria","year":"2020","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.cmpb.2026.109652_bib0048","unstructured":"Watchman flx device: product brochure, (n.d.)."},{"key":"10.1016\/j.cmpb.2026.109652_bib0049","unstructured":"3d slicer image computing platform., (n.d.)."},{"key":"10.1016\/j.cmpb.2026.109652_bib0050","doi-asserted-by":"crossref","unstructured":"R.P.S.V.K. Kikinis, 3D slicer: a platform for subject-specific image analysis, visualization, and clinical support, 3 (2014) 277\u2013289.","DOI":"10.1007\/978-1-4614-7657-3_19"},{"key":"10.1016\/j.cmpb.2026.109652_bib0051","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.121.022274","article-title":"Left atrial appendage occlusion for stroke prevention in nonvalvular atrial fibrillation","volume":"10","author":"Collado","year":"2021","journal-title":"J. Am. Heart Assoc."},{"key":"10.1016\/j.cmpb.2026.109652_bib0052","doi-asserted-by":"crossref","first-page":"1133","DOI":"10.4244\/EIJY19M08_01","article-title":"EHRA\/EAPCI expert consensus statement on catheter-based left atrial appendage occlusion - an update","volume":"15","author":"Glikson","year":"2020","journal-title":"EuroIntervention"},{"key":"10.1016\/j.cmpb.2026.109652_bib0053","doi-asserted-by":"crossref","unstructured":"J. Saw, M. Lempereur, Percutaneous Left Atrial Appendage Closure Procedural Techniques and Outcomes, 2014.","DOI":"10.1016\/j.jcin.2014.05.026"},{"key":"10.1016\/j.cmpb.2026.109652_bib0054","doi-asserted-by":"crossref","first-page":"1781","DOI":"10.1111\/jce.15548","article-title":"Novel computed tomography angiography-based sizing methodology for WATCHMAN FLX","volume":"33","author":"Dallan","year":"2022","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0055","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1002\/cnm.3254","article-title":"Analysis of a coupled fluid-structure interaction model of the left atrium and mitral valve","volume":"35","author":"Feng","year":"2019","journal-title":"Int. J. Numer. Method. Biomed. Eng."},{"key":"10.1016\/j.cmpb.2026.109652_bib0056","doi-asserted-by":"crossref","unstructured":"Y. Nakatani, T. Sakamoto, Y. Yamaguchi, Y. Tsujino, N. Kataoka, K. Kinugawa, Heterogeneity in the left atrial wall thickness contributes to atrial fibrillation recurrence after catheter ablation, Heart Vessels. 33 (2018) 1549\u20131558. https:\/\/doi.org\/10.1007\/s00380-018-1200-y.","DOI":"10.1007\/s00380-018-1200-y"},{"key":"10.1016\/j.cmpb.2026.109652_bib0057","doi-asserted-by":"crossref","first-page":"2262","DOI":"10.1111\/jce.15157","article-title":"Thickness of the left atrial wall surrounding the left atrial appendage","volume":"32","author":"S\u0142odowska","year":"2021","journal-title":"J. Cardiovasc. Electrophysiol."},{"key":"10.1016\/j.cmpb.2026.109652_bib0058","doi-asserted-by":"crossref","first-page":"825","DOI":"10.1115\/1.2801650","article-title":"Finite element modeling of the left atrium to facilitate the design of an endoscopic atrial retractor","volume":"129","author":"Jernigan","year":"2007","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.cmpb.2026.109652_bib0059","doi-asserted-by":"crossref","first-page":"2139","DOI":"10.1016\/j.jcin.2023.05.045","article-title":"Impact of device implant depth after left atrial appendage occlusion","volume":"16","author":"Cepas-Guill\u00e9n","year":"2023","journal-title":"JACC Cardiovasc. Interv."}],"container-title":["Computer Methods and Programs in Biomedicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0169260726004013?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0169260726004013?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,30]],"date-time":"2026-09-30T20:29:58Z","timestamp":1790800198000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0169260726004013"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,12]]},"references-count":59,"alternative-id":["S0169260726004013"],"URL":"https:\/\/doi.org\/10.1016\/j.cmpb.2026.109652","relation":{},"ISSN":["0169-2607"],"issn-type":[{"value":"0169-2607","type":"print"}],"subject":[],"published":{"date-parts":[[2026,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Toward a computationally efficient numerical approach to simulate the left atrial appendage occlusion in patient-specific anatomies","name":"articletitle","label":"Article Title"},{"value":"Computer Methods and Programs in Biomedicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.cmpb.2026.109652","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Author(s). Published by Elsevier B.V.","name":"copyright","label":"Copyright"}],"article-number":"109652"}}