{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,4]],"date-time":"2025-12-04T14:36:58Z","timestamp":1764859018339,"version":"3.37.3"},"reference-count":29,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2018,5,1]],"date-time":"2018-05-01T00:00:00Z","timestamp":1525132800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"funder":[{"DOI":"10.13039\/501100000925","name":"National Health and Medical Research Council","doi-asserted-by":"publisher","award":["1093314"],"award-info":[{"award-number":["1093314"]}],"id":[{"id":"10.13039\/501100000925","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.jp","clinicalkey.com","clinicalkey.es","clinicalkey.com.au","clinicalkey.fr","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Computers in Biology and Medicine"],"published-print":{"date-parts":[[2018,5]]},"DOI":"10.1016\/j.compbiomed.2018.02.014","type":"journal-article","created":{"date-parts":[[2018,2,26]],"date-time":"2018-02-26T12:56:17Z","timestamp":1519649777000},"page":"1-7","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["Automated geometric optimization for robotic HIFU treatment of liver tumors"],"prefix":"10.1016","volume":"96","author":[{"given":"Tom","family":"Williamson","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Scott","family":"Everitt","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Sunita","family":"Chauhan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.compbiomed.2018.02.014_bib1","series-title":"A\u00a0Robotic Approach to HIFU Based Neurosurgery","first-page":"386","author":"Davies","year":"1998"},{"issue":"6","key":"10.1016\/j.compbiomed.2018.02.014_bib2","doi-asserted-by":"crossref","first-page":"353","DOI":"10.3109\/10929080802586825","article-title":"Intra-operative feedback and dynamic compensation for image-guided robotic focal ultrasound surgery","volume":"13","author":"Chauhan","year":"2008","journal-title":"Comput. Aided Surg."},{"key":"10.1016\/j.compbiomed.2018.02.014_bib3","series-title":"Medical Robotics, I-Tech Education and Publishing","first-page":"29","article-title":"Image guided robotic systems for focal ultrasound based surgical applications","author":"Chauhan","year":"2008"},{"issue":"Pt 3","key":"10.1016\/j.compbiomed.2018.02.014_bib4","first-page":"388","article-title":"A\u00a0novel high intensity focused ultrasound robotic system for breast cancer treatment","volume":"16","author":"Yonetsuji","year":"2013","journal-title":"Med. Image Comput. Comput. Assist. Interv."},{"issue":"8","key":"10.1016\/j.compbiomed.2018.02.014_bib5","doi-asserted-by":"crossref","first-page":"890","DOI":"10.1038\/sj.bjc.6602803","article-title":"The safety and feasibility of extracorporeal high-intensity focused ultrasound (HIFU) for the treatment of liver and kidney tumours in a Western population","volume":"93","author":"Illing","year":"2005","journal-title":"Br. J. Cancer"},{"issue":"11","key":"10.1016\/j.compbiomed.2018.02.014_bib6","doi-asserted-by":"crossref","first-page":"1743","DOI":"10.1088\/0031-9155\/34\/11\/021","article-title":"High intensity focused ultrasound\u2013a surgical technique for the treatment of discrete liver tumours","volume":"34","author":"ter Haar","year":"1989","journal-title":"Phys. Med. Biol."},{"issue":"2","key":"10.1016\/j.compbiomed.2018.02.014_bib7","doi-asserted-by":"crossref","first-page":"404","DOI":"10.1002\/jmri.21688","article-title":"MRI-based thermal dosimetry and diffusion-weighted imaging of MRI-guided focused ultrasound thermal ablation of uterine fibroids","volume":"29","author":"Pilatou","year":"2009","journal-title":"J.\u00a0Magn. Reson. Imag."},{"key":"10.1016\/j.compbiomed.2018.02.014_bib8","first-page":"1311","article-title":"A\u00a0computer-assisted robotic platform for Focused Ultrasound Surgery: assessment of high intensity focused ultrasound delivery","volume":"2015","author":"Cafarelli","year":"2015","journal-title":"Conf. Proc. Annu. Int. Conf. IEEE Eng. Med. Biol. Soc."},{"issue":"1","key":"10.1016\/j.compbiomed.2018.02.014_bib9","doi-asserted-by":"crossref","first-page":"20","DOI":"10.1186\/s40349-017-0098-7","article-title":"A\u00a0focused ultrasound treatment system for moving targets (part I): generic system design and in-silico first-stage evaluation","volume":"5","author":"Schwenke","year":"2017","journal-title":"J.\u00a0Ther. Ultrasound"},{"issue":"1","key":"10.1016\/j.compbiomed.2018.02.014_bib10","doi-asserted-by":"crossref","first-page":"7","DOI":"10.1002\/rcs.360","article-title":"A\u00a0navigation system for open liver surgery: design, workflow and first clinical applications","volume":"7","author":"Peterhans","year":"2011","journal-title":"Int. J. Med. Robot. Comput. Assist. Surg."},{"issue":"12","key":"10.1016\/j.compbiomed.2018.02.014_bib11","doi-asserted-by":"crossref","first-page":"1416","DOI":"10.1001\/archsurg.2011.212","article-title":"Hepatic resection vs minimally invasive radiofrequency ablation for the treatment of colorectal liver metastases: a Markov analysis","volume":"146","author":"Khajanchee","year":"2011","journal-title":"Arch. Surg."},{"issue":"3","key":"10.1016\/j.compbiomed.2018.02.014_bib12","doi-asserted-by":"crossref","first-page":"1022","DOI":"10.1148\/radiol.11110817","article-title":"Radiofrequency ablation versus hepatic resection for the treatment of hepatocellular carcinomas 2 cm or smaller: a retrospective comparative study","volume":"262","author":"Peng","year":"2012","journal-title":"Radiology"},{"issue":"1","key":"10.1016\/j.compbiomed.2018.02.014_bib13","doi-asserted-by":"crossref","first-page":"41","DOI":"10.1016\/0377-0427(92)90052-Y","article-title":"The sphere packing problem","volume":"44","author":"Hales","year":"1992","journal-title":"J.\u00a0Comput. Appl. Math."},{"issue":"5660","key":"10.1016\/j.compbiomed.2018.02.014_bib14","doi-asserted-by":"crossref","first-page":"990","DOI":"10.1126\/science.1093010","article-title":"Improving the density of jammed disordered packings using ellipsoids","volume":"303","author":"Donev","year":"2004","journal-title":"Science (80)"},{"issue":"2","key":"10.1016\/j.compbiomed.2018.02.014_bib15","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1063\/1.1698327","article-title":"Density and packing in an aggregate of mixed spheres","volume":"20","author":"Hudson","year":"1949","journal-title":"J.\u00a0Appl. Phys."},{"issue":"4","key":"10.1016\/j.compbiomed.2018.02.014_bib16","doi-asserted-by":"crossref","first-page":"220","DOI":"10.3109\/10929080009148891","article-title":"Optimization of multiple-isocenter treatment planning for linac-based stereotactic radiosurgery","volume":"5","author":"Liao","year":"2000","journal-title":"Comput. Aided Surg."},{"key":"10.1016\/j.compbiomed.2018.02.014_bib17","series-title":"Proceedings of the Third ACM Symposium on Solid Modeling and Applications - SMA \u201995","first-page":"409","article-title":"Bubble mesh: automated triangular meshing of non-manifold geometry by sphere packing","author":"Shimada","year":"1995"},{"issue":"1","key":"10.1016\/j.compbiomed.2018.02.014_bib18","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1115\/1.2136166","article-title":"Two-phase computerized planning of cryosurgery using bubble-packing and force-field analogy","volume":"128","author":"Shimada","year":"2005","journal-title":"J.\u00a0Biomech. Eng."},{"issue":"2","key":"10.1016\/j.compbiomed.2018.02.014_bib19","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1080\/10255840701336653","article-title":"Cryosurgery planning using bubble packing in 3D","volume":"11","author":"Tanaka","year":"2008","journal-title":"Comput. Methods Biomech. Biomed. Engin."},{"issue":"1","key":"10.1016\/j.compbiomed.2018.02.014_bib20","doi-asserted-by":"crossref","first-page":"1","DOI":"10.3109\/10929080701882556","article-title":"Computerized planning of prostate cryosurgery with pullback operation","volume":"13","author":"Tanaka","year":"2008","journal-title":"Comput. Aided Surg."},{"issue":"11","key":"10.1016\/j.compbiomed.2018.02.014_bib21","doi-asserted-by":"crossref","first-page":"1310","DOI":"10.1016\/j.acra.2007.07.016","article-title":"Multiscale optimization of the probe placement for radiofrequency ablation","volume":"14","author":"Altrogge","year":"2007","journal-title":"Acad. Radiol."},{"year":"2016","series-title":"BodyParts3D\/Anatomography: Select Parts and Make Embeddable Model of Your Own","key":"10.1016\/j.compbiomed.2018.02.014_bib22"},{"issue":"s2","key":"10.1016\/j.compbiomed.2018.02.014_bib23","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1111\/j.1464-410X.2005.05200.x","article-title":"Extracorporeal ablation of renal tumours with high-intensity focused ultrasound","volume":"95","author":"Marberger","year":"2005","journal-title":"BJU Int."},{"issue":"8","key":"10.1016\/j.compbiomed.2018.02.014_bib24","doi-asserted-by":"crossref","first-page":"1036","DOI":"10.1089\/end.2005.19.1036","article-title":"Multiple high-intensity focused ultrasound probes for kidney-tissue ablation","volume":"19","author":"H\u00e4cker","year":"2005","journal-title":"J.\u00a0Endourol."},{"key":"10.1016\/j.compbiomed.2018.02.014_bib25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1186\/2047-783X-19-1","article-title":"Effect of lung flooding and high-intensity focused ultrasound on lung tumours: an experimental study in an ex vivo human cancer model and simulated in vivo tumours in pigs.","volume":"19","author":"Wolfram","year":"2014","journal-title":"Eur. J. Med. Res."},{"issue":"1","key":"10.1016\/j.compbiomed.2018.02.014_bib26","doi-asserted-by":"crossref","first-page":"193","DOI":"10.2214\/AJR.15.15803","article-title":"Stereotactic CT-guided percutaneous microwave ablation of liver tumors with the use of high-frequency jet ventilation: an accuracy and procedural safety study","volume":"208","author":"Engstrand","year":"2017","journal-title":"Am. J. Roentgenol."},{"issue":"6","key":"10.1016\/j.compbiomed.2018.02.014_bib27","doi-asserted-by":"crossref","first-page":"353","DOI":"10.3109\/10929080802586825","article-title":"Intra-operative feedback and dynamic compensation for image-guided robotic focal ultrasound surgery","volume":"13","author":"Chauhan","year":"2008","journal-title":"Comput. Aided Surg."},{"issue":"4","key":"10.1016\/j.compbiomed.2018.02.014_bib28","doi-asserted-by":"crossref","first-page":"163","DOI":"10.1145\/37402.37422","article-title":"Marching cubes: a high resolution 3D surface construction algorithm","volume":"21","author":"Lorensen","year":"1987","journal-title":"ACM SIGGRAPH Comput. Graph."},{"issue":"12","key":"10.1016\/j.compbiomed.2018.02.014_bib29","doi-asserted-by":"crossref","first-page":"3139","DOI":"10.1088\/0031-9155\/59\/12\/3139","article-title":"A\u00a0comparison of methods for focusing the field of a HIFU array transducer through human ribs","volume":"59","author":"G\u00e9lat","year":"2014","journal-title":"Phys. Med. Biol."}],"container-title":["Computers in Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010482518300441?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010482518300441?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2018,12,28]],"date-time":"2018-12-28T17:00:59Z","timestamp":1546016459000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0010482518300441"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2018,5]]},"references-count":29,"alternative-id":["S0010482518300441"],"URL":"https:\/\/doi.org\/10.1016\/j.compbiomed.2018.02.014","relation":{},"ISSN":["0010-4825"],"issn-type":[{"type":"print","value":"0010-4825"}],"subject":[],"published":{"date-parts":[[2018,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Automated geometric optimization for robotic HIFU treatment of liver tumors","name":"articletitle","label":"Article Title"},{"value":"Computers in Biology and Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.compbiomed.2018.02.014","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2018 Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}