{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,2,13]],"date-time":"2026-02-13T23:31:01Z","timestamp":1771025461771,"version":"3.50.1"},"reference-count":45,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,3,1]],"date-time":"2024-03-01T00:00:00Z","timestamp":1709251200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2023,12,28]],"date-time":"2023-12-28T00:00:00Z","timestamp":1703721600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100004587","name":"Instituto de Salud Carlos III","doi-asserted-by":"publisher","award":["DTS21\/00103"],"award-info":[{"award-number":["DTS21\/00103"]}],"id":[{"id":"10.13039\/501100004587","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000780","name":"European Commission","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000780","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Computers in Biology and Medicine"],"published-print":{"date-parts":[[2024,3]]},"DOI":"10.1016\/j.compbiomed.2023.107870","type":"journal-article","created":{"date-parts":[[2023,12,28]],"date-time":"2023-12-28T16:26:16Z","timestamp":1703780776000},"page":"107870","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":2,"special_numbering":"C","title":["Comparative evaluation of methods for obtaining the stress-free geometry of keratoconus corneas with different levels of severity"],"prefix":"10.1016","volume":"170","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-2915-9165","authenticated-orcid":false,"given":"Carmelo","family":"G\u00f3mez","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-1546-4807","authenticated-orcid":false,"given":"David P.","family":"Pi\u00f1ero","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8082-1751","authenticated-orcid":false,"given":"Jorge L.","family":"Ali\u00f3","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-8391-0688","authenticated-orcid":false,"given":"Francisco","family":"Cavas","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.compbiomed.2023.107870_bib1","doi-asserted-by":"crossref","first-page":"851","DOI":"10.1016\/j.survophthal.2018.05.004","article-title":"Biomechanics and structure of the cornea: implications and association with corneal disorders","volume":"63","author":"Ma","year":"2018","journal-title":"Surv. Ophthalmol."},{"key":"10.1016\/j.compbiomed.2023.107870_bib2","doi-asserted-by":"crossref","DOI":"10.1016\/j.preteyeres.2022.101161","article-title":"The pre-Descemet's layer (Dua's layer, also known as the Dua-Fine layer and the pre-posterior limiting lamina layer): discovery, characterisation, clinical and surgical applications, and the controversy","volume":"97","author":"Dua","year":"2023","journal-title":"Prog. Retin. Eye Res."},{"key":"10.1016\/j.compbiomed.2023.107870_bib3","first-page":"232","article-title":"Implications of the structure-property relationship on the optomechanical characterization of the cornea: a review","author":"Gururani","year":"2021","journal-title":"Optik"},{"key":"10.1016\/j.compbiomed.2023.107870_bib4","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1016\/j.jcrs.2014.04.013","article-title":"Biomechanics of corneal ectasia and biomechanical treatments","volume":"40","author":"Roberts","year":"2014","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.compbiomed.2023.107870_bib5","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2020.104155","article-title":"Biomechanics of the keratoconic cornea: theory, segmentation, pressure distribution, and coupled FE-optimization algorithm","volume":"113","author":"Rahmati","year":"2021","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.compbiomed.2023.107870_bib6","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1016\/j.cjph.2022.10.002","article-title":"Numerical solutions and geometric attractors of a fractional model of the cancer-immune based on the Atangana-Baleanu-Caputo derivative and the reproducing kernel scheme","volume":"80","author":"Maayah","year":"2022","journal-title":"Chin. J. Phys."},{"key":"10.1016\/j.compbiomed.2023.107870_bib7","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1590\/S0004-27492009000200002","article-title":"Keratoconus prediction using a finite element model of the cornea with local biomechanical properties","volume":"72","author":"Carvalho","year":"2009","journal-title":"Arq. Bras. Oftalmol."},{"key":"10.1016\/j.compbiomed.2023.107870_bib8","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1016\/j.jmbbm.2008.07.002","article-title":"Biomechanical analysis of the keratoconic cornea","volume":"2","author":"Gefen","year":"2009","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.compbiomed.2023.107870_bib9","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1186\/s40662-020-0174-x","article-title":"Biomechanical diagnostics of the cornea","volume":"7","author":"Esporcatte","year":"2020","journal-title":"Eye and Vision"},{"key":"10.1016\/j.compbiomed.2023.107870_bib10","doi-asserted-by":"crossref","DOI":"10.1115\/1.2982251","article-title":"Three-dimensional modeling and computational analysis of the human cornea considering distributed collagen fibril orientations","volume":"130","author":"Pandolfi","year":"2008","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.compbiomed.2023.107870_bib11","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1002\/nme.1726","article-title":"On the numerical treatment of initial strains in biological soft tissues","volume":"68","author":"Pe\u00f1a","year":"2006","journal-title":"Int. J. Numer. Methods Eng."},{"key":"10.1016\/j.compbiomed.2023.107870_bib12","doi-asserted-by":"crossref","first-page":"211","DOI":"10.1016\/j.medengphy.2012.09.006","article-title":"Stress free configuration of the human eye","volume":"35","author":"Elsheikh","year":"2013","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.compbiomed.2023.107870_bib13","doi-asserted-by":"crossref","first-page":"143","DOI":"10.1109\/RBME.2017.2773521","article-title":"Deformable models for surgical simulation: a survey","volume":"11","author":"Zhang","year":"2018","journal-title":"IEEE Reviews in Biomedical Engineering"},{"key":"10.1016\/j.compbiomed.2023.107870_bib14","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1016\/j.medengphy.2016.01.012","article-title":"Gaussian process prediction of the stress-free configuration of pre-deformed soft tissues: application to the human cornea","volume":"38","author":"Businaro","year":"2016","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.compbiomed.2023.107870_bib15","doi-asserted-by":"crossref","first-page":"797","DOI":"10.1016\/j.jbiomech.2007.11.010","article-title":"Finite element simulation of arcuates for astigmatism correction","volume":"41","author":"Lanchares","year":"2008","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2023.107870_bib16","doi-asserted-by":"crossref","first-page":"11","DOI":"10.35119\/maio.v2i4.106","article-title":"On the recovery of the stress-free configuration of the human cornea","volume":"2","author":"Pandolfi","year":"2020","journal-title":"Modeling and Artificial Intelligence in Ophthalmology"},{"key":"10.1016\/j.compbiomed.2023.107870_bib17","doi-asserted-by":"crossref","first-page":"821","DOI":"10.1002\/(SICI)1097-0207(19981115)43:5<821::AID-NME453>3.0.CO;2-C","article-title":"Computational methods for inverse deformations in quasi-incompressible finite elasticity","volume":"43","author":"Govindjee","year":"1998","journal-title":"Int. J. Numer. Methods Eng."},{"key":"10.1016\/j.compbiomed.2023.107870_bib18","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1016\/0045-7825(96)01045-6","article-title":"Computational methods for inverse finite elastostatics","volume":"136","author":"Govindjee","year":"1996","journal-title":"Comput. Methods Appl. Mech. Eng."},{"key":"10.1016\/j.compbiomed.2023.107870_bib19","doi-asserted-by":"crossref","first-page":"768","DOI":"10.1080\/10255842.2011.641119","article-title":"A forward incremental prestressing method with application to inverse parameter estimations and eye-specific simulations of posterior scleral shells","volume":"16","author":"Grytz","year":"2013","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"10.1016\/j.compbiomed.2023.107870_bib20","doi-asserted-by":"crossref","first-page":"52","DOI":"10.1002\/cnm.1236","article-title":"A computational strategy for prestressing patient-specific biomechanical problems under finite deformation","volume":"26","author":"Gee","year":"2010","journal-title":"International Journal for Numerical Methods in Biomedical Engineering"},{"key":"10.1016\/j.compbiomed.2023.107870_bib21","doi-asserted-by":"crossref","first-page":"260","DOI":"10.1016\/j.jmbbm.2015.07.023","article-title":"Patient-specific simulation of the intrastromal ring segment implantation in corneas with keratoconus","volume":"51","author":"Lago","year":"2015","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.compbiomed.2023.107870_bib22","doi-asserted-by":"crossref","first-page":"480","DOI":"10.3928\/1081597X-20150623-07","article-title":"Biomechanical modeling of femtosecond laser keyhole endokeratophakia surgery","volume":"31","author":"Studer","year":"2015","journal-title":"J. Refract. Surg."},{"key":"10.1016\/j.compbiomed.2023.107870_bib23","doi-asserted-by":"crossref","first-page":"751","DOI":"10.1016\/j.jbiomech.2012.11.018","article-title":"Patient-specific finite-element simulation of the human cornea: a clinical validation study on cataract surgery","volume":"46","author":"Studer","year":"2013","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2023.107870_bib24","doi-asserted-by":"crossref","DOI":"10.3389\/fbioe.2019.00105","article-title":"Determination of corneal biomechanical behavior in-vivo for healthy eyes using CorVis ST tonometry: stress-strain index","volume":"7","author":"Eliasy","year":"2019","journal-title":"Front. Bioeng. Biotechnol."},{"key":"10.1016\/j.compbiomed.2023.107870_bib25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1167\/tvst.9.11.26","article-title":"Corneal biomechanics after intrastromal ring surgery: optomechanical in silico assessment","volume":"9","author":"Ariza-Gracia","year":"2020","journal-title":"Translational Vision Science and Technology"},{"key":"10.1016\/j.compbiomed.2023.107870_bib26","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1016\/j.jmbbm.2018.04.016","article-title":"Development and clinical verification of numerical simulation for laser in situ keratomileusis","volume":"83","author":"Bao","year":"2018","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.compbiomed.2023.107870_bib27","article-title":"A large-scale computational analysis of corneal structural response and ectasia risk in myopic laser refractive surgery (An American ophthalmological society thesis)","volume":"114","author":"Dupps","year":"2016","journal-title":"Trans. Am. Ophthalmol. Soc."},{"key":"10.1016\/j.compbiomed.2023.107870_bib28","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2023.105998","article-title":"Modeling the biomechanics of laser corneal refractive surgery","volume":"145","author":"Montanino","year":"2023","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.compbiomed.2023.107870_bib29","doi-asserted-by":"crossref","first-page":"694","DOI":"10.1007\/s10439-012-0712-3","article-title":"A pull-back algorithm to determine the unloaded vascular geometry in anisotropic hyperelastic AAA passive mechanics","volume":"41","author":"Riveros","year":"2013","journal-title":"Ann. Biomed. Eng."},{"key":"10.1016\/j.compbiomed.2023.107870_bib30","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1016\/j.jcrs.2014.03.020","article-title":"Biomechanical and optical behavior of human corneas before and after photorefractive keratectomy","volume":"40","author":"S\u00e1nchez","year":"2014","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.compbiomed.2023.107870_bib31","doi-asserted-by":"crossref","first-page":"6287","DOI":"10.1167\/iovs.16-19948","article-title":"Comparison of patient-specific computational modeling predictions and clinical outcomes of lasik for myopia","volume":"57","author":"Seven","year":"2016","journal-title":"Investigative Ophthalmology and Visual Science"},{"key":"10.1016\/j.compbiomed.2023.107870_bib32","doi-asserted-by":"crossref","first-page":"1084","DOI":"10.1016\/j.jcrs.2019.02.022","article-title":"Optimization of surgical parameters based on patient-specific models: application to arcuate keratotomy","volume":"45","author":"Truffer","year":"2019","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.compbiomed.2023.107870_bib33","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2022.105252","article-title":"Numerical estimation of stress and refractive power maps in healthy and keratoconus eyes","volume":"131","author":"Simonini","year":"2022","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.compbiomed.2023.107870_bib34","doi-asserted-by":"crossref","first-page":"2167","DOI":"10.1016\/j.jcrs.2012.10.022","article-title":"Characterization of corneal structure in keratoconus","volume":"38","author":"Pi\u00f1ero","year":"2012","journal-title":"J. Cataract Refract. Surg."},{"key":"10.1016\/j.compbiomed.2023.107870_bib35","doi-asserted-by":"crossref","first-page":"297","DOI":"10.1016\/S0039-6257(97)00119-7","volume":"42","author":"Rabinowitz","year":"1998","journal-title":"Keratoconus, Survey of Ophthalmology"},{"key":"10.1016\/j.compbiomed.2023.107870_bib36","doi-asserted-by":"crossref","first-page":"e933","DOI":"10.1111\/aos.14433","article-title":"Subclinical keratoconus detection with three-dimensional (3-D) morphogeometric and volumetric analysis","volume":"98","author":"Toprak","year":"2020","journal-title":"Acta Ophthalmol."},{"key":"10.1016\/j.compbiomed.2023.107870_bib37","doi-asserted-by":"crossref","first-page":"102","DOI":"10.1016\/j.ajo.2020.09.031","article-title":"Three-dimensional morphogeometric and volumetric characterization of cornea in pediatric patients with early keratoconus","volume":"222","author":"Toprak","year":"2021","journal-title":"American journal of ophthalmology"},{"key":"10.1016\/j.compbiomed.2023.107870_bib38","doi-asserted-by":"crossref","first-page":"261","DOI":"10.1016\/j.jare.2020.03.012","article-title":"Morphogeometric analysis for characterization of keratoconus considering the spatial localization and projection of apex and minimum corneal thickness point","volume":"24","author":"Vel\u00e1zquez","year":"2020","journal-title":"J. Adv. Res."},{"key":"10.1016\/j.compbiomed.2023.107870_bib39","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0236096","article-title":"Limbus misrepresentation in parametric eye models","volume":"15","author":"Moore","year":"2020","journal-title":"PLoS One"},{"key":"10.1016\/j.compbiomed.2023.107870_bib40","series-title":"Corneal Topography: Principles and Applications","author":"Corbett","year":"2019"},{"key":"10.1016\/j.compbiomed.2023.107870_bib41","first-page":"121","article-title":"Collagen fibril orientation in the human corneal stroma and its implication in keratoconus","volume":"38","author":"Daxer","year":"1997","journal-title":"Investigative Ophthalmology and Visual Science"},{"key":"10.1016\/j.compbiomed.2023.107870_bib42","article-title":"Cornea modelling","volume":"7","author":"Pandolfi","year":"2020","journal-title":"Eye Vis (Lond)"},{"key":"10.1016\/j.compbiomed.2023.107870_bib43","article-title":"Small-angle fibre diffraction studies of cornela matrix structure: a depth-profiled investigation of the human EyeBank cornea","volume":"40","author":"Quantock","year":"2007","journal-title":"Journal of Applied Crystallography - J APPL CRYST"},{"key":"10.1016\/j.compbiomed.2023.107870_bib44","doi-asserted-by":"crossref","first-page":"287","DOI":"10.1080\/10255842.2018.1447104","article-title":"Sensitivity of corneal biomechanical and optical behavior to material parameters using design of experiments method","volume":"21","author":"Xu","year":"2018","journal-title":"Comput. Methods Biomech. Biomed. Eng."},{"key":"10.1016\/j.compbiomed.2023.107870_bib45","doi-asserted-by":"crossref","first-page":"215","DOI":"10.1586\/17469899.2015.1044979","article-title":"Topography and tomography in the diagnosis of corneal ectasia","volume":"10","author":"Ramamurthy","year":"2015","journal-title":"Expet Rev. Ophthalmol."}],"container-title":["Computers in Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010482523013355?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010482523013355?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,9,25]],"date-time":"2024-09-25T18:43:04Z","timestamp":1727289784000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0010482523013355"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,3]]},"references-count":45,"alternative-id":["S0010482523013355"],"URL":"https:\/\/doi.org\/10.1016\/j.compbiomed.2023.107870","relation":{},"ISSN":["0010-4825"],"issn-type":[{"value":"0010-4825","type":"print"}],"subject":[],"published":{"date-parts":[[2024,3]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Comparative evaluation of methods for obtaining the stress-free geometry of keratoconus corneas with different levels of severity","name":"articletitle","label":"Article Title"},{"value":"Computers in Biology and Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.compbiomed.2023.107870","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2023 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"107870"}}