{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,17]],"date-time":"2026-08-17T17:21:14Z","timestamp":1786987274833,"version":"build-2736575974"},"reference-count":26,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,3,4]],"date-time":"2024-03-04T00:00:00Z","timestamp":1709510400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Computers in Biology and Medicine"],"published-print":{"date-parts":[[2024,4]]},"DOI":"10.1016\/j.compbiomed.2024.108180","type":"journal-article","created":{"date-parts":[[2024,2,28]],"date-time":"2024-02-28T04:12:44Z","timestamp":1709093564000},"page":"108180","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":11,"special_numbering":"C","title":["Enhancing the accuracy of shock advisory algorithms in automated external defibrillators during ongoing cardiopulmonary resuscitation using a cascade of CNNEDs"],"prefix":"10.1016","volume":"172","author":[{"given":"Mahdi Pirayesh Shirazi","family":"Nejad","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Vadym","family":"Kargin","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9563-1627","authenticated-orcid":false,"given":"Shirin","family":"Hajeb-M","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"David","family":"Hicks","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Matt","family":"Valentine","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4422-4837","authenticated-orcid":false,"given":"K.H.","family":"Chon","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.compbiomed.2024.108180_bib1","doi-asserted-by":"crossref","DOI":"10.1016\/j.eswa.2022.117499","article-title":"Enhancing the accuracy of shock advisory algorithms in automated external defibrillators during ongoing cardiopulmonary resuscitation using a deep convolutional Encoder-Decoder filtering model","volume":"203","author":"Hajeb-M","year":"2022","journal-title":"Expert Syst. Appl."},{"issue":"1","key":"10.1016\/j.compbiomed.2024.108180_bib2","first-page":"43","article-title":"The \u2018chain of survival\u2019 concept: how it can save lives","volume":"1","author":"Cummins","year":"1992","journal-title":"Heart Dis. Stroke"},{"issue":"2","key":"10.1016\/j.compbiomed.2024.108180_bib3","doi-asserted-by":"crossref","first-page":"113","DOI":"10.1016\/S0300-9572(01)00407-5","article-title":"Survival models for out-of-hospital cardiopulmonary resuscitation from the perspectives of the bystander, the first responder, and the paramedic","volume":"51","author":"Waalewijn","year":"2001","journal-title":"Resuscitation"},{"issue":"1","key":"10.1016\/j.compbiomed.2024.108180_bib4","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0300-9572(02)00047-3","article-title":"Prevention of deterioration of ventricular fibrillation by basic life support during out-of-hospital cardiac arrest","volume":"54","author":"Waalewijn","year":"2002","journal-title":"Resuscitation"},{"issue":"11","key":"10.1016\/j.compbiomed.2024.108180_bib5","doi-asserted-by":"crossref","first-page":"S409","DOI":"10.1097\/CCM.0b013e31818a7fbf","article-title":"Electrocardiographic analysis during uninterrupted cardiopulmonary resuscitation","volume":"36","author":"Tan","year":"2008","journal-title":"Crit. Care Med."},{"issue":"2","key":"10.1016\/j.compbiomed.2024.108180_bib6","doi-asserted-by":"crossref","first-page":"131","DOI":"10.1016\/j.resuscitation.2003.12.019","article-title":"Feasibility of shock advice analysis during CPR through removal of CPR artefacts from the human ECG","volume":"61","author":"Eilevstj\u00f8nn","year":"2004","journal-title":"Resuscitation"},{"issue":"9","key":"10.1016\/j.compbiomed.2024.108180_bib7","doi-asserted-by":"crossref","first-page":"1087","DOI":"10.1016\/j.resuscitation.2010.02.031","article-title":"Cardiopulmonary resuscitation artefact suppression using a Kalman filter and the frequency of chest compressions as the reference signal","volume":"81","author":"Ruiz","year":"2010","journal-title":"Resuscitation"},{"issue":"1","key":"10.1016\/j.compbiomed.2024.108180_bib8","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1109\/TBME.2007.902235","article-title":"Removal of CPR artifacts from the ventricular fibrillation ECG by adaptive regression on lagged reference signals","volume":"55","author":"Rheinberger","year":"2008","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.compbiomed.2024.108180_bib9","doi-asserted-by":"crossref","DOI":"10.1155\/2014\/140438","article-title":"Removal of cardiopulmonary resuscitation artifacts with an enhanced adaptive filtering method: an experimental trial","volume":"2014","author":"Gong","year":"2014","journal-title":"BioMed Res. Int."},{"issue":"2","key":"10.1016\/j.compbiomed.2024.108180_bib10","doi-asserted-by":"crossref","first-page":"471","DOI":"10.1109\/TBME.2016.2564642","article-title":"An enhanced adaptive filtering method for suppressing cardiopulmonary resuscitation artifact","volume":"64","author":"Gong","year":"2017","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"4","key":"10.1016\/j.compbiomed.2024.108180_bib11","doi-asserted-by":"crossref","first-page":"1052","DOI":"10.1109\/TBME.2008.2010329","article-title":"A least mean-square filter for the estimation of the cardiopulmonary resuscitation artifact based on the frequency of the compressions","volume":"56","author":"Irusta","year":"2009","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"2","key":"10.1016\/j.compbiomed.2024.108180_bib12","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1109\/TBME.2008.2003107","article-title":"CPR artifact removal in ventricular fibrillation ECG signals using gabor multipliers","volume":"56","author":"Werther","year":"2009","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"6","key":"10.1016\/j.compbiomed.2024.108180_bib13","doi-asserted-by":"crossref","first-page":"1752","DOI":"10.1109\/TBME.2018.2878910","article-title":"A machine learning shock decision algorithm for use during piston-driven chest compressions","volume":"66","author":"Isasi","year":"2019","journal-title":"IEEE Trans. Biomed. Eng."},{"issue":"6","key":"10.1016\/j.compbiomed.2024.108180_bib14","doi-asserted-by":"crossref","DOI":"10.1161\/JAHA.120.019065","article-title":"Deep neural network approach for continuous ECG\u2010based automated external defibrillator shock advisory system during cardiopulmonary resuscitation","volume":"10","author":"Hajeb\u2010M","year":"2021","journal-title":"J. Am. Heart Assoc."},{"issue":"2","key":"10.1016\/j.compbiomed.2024.108180_bib15","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1016\/j.resuscitation.2007.08.002","article-title":"A method to remove CPR artefacts from human ECG using only the recorded ECG","volume":"76","author":"Ruiz de Gauna","year":"2008","journal-title":"Resuscitation"},{"key":"10.1016\/j.compbiomed.2024.108180_bib16","series-title":"2009 36th Annual Computers in Cardiology Conference (CinC)","first-page":"817","article-title":"Detection of shockable and non-shockable rhythms in presence of CPR artifacts by time-frequency ECG analysis","author":"Didon","year":"2009"},{"issue":"11","key":"10.1016\/j.compbiomed.2024.108180_bib17","doi-asserted-by":"crossref","first-page":"1219","DOI":"10.1016\/j.resuscitation.2009.09.003","article-title":"Techniques for artefact filtering from chest compression corrupted ECG signals: good, but not enough","volume":"80","author":"Li","year":"2009","journal-title":"Resuscitation"},{"issue":"1","key":"10.1016\/j.compbiomed.2024.108180_bib18","doi-asserted-by":"crossref","first-page":"115","DOI":"10.1016\/j.resuscitation.2006.05.017","article-title":"Detection of ventricular fibrillation in the presence of cardiopulmonary resuscitation artefacts","volume":"72","author":"Aramendi","year":"2007","journal-title":"Resuscitation"},{"key":"10.1016\/j.compbiomed.2024.108180_bib19","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1016\/j.resuscitation.2021.01.003","article-title":"Analyzing the heart rhythm during chest compressions: performance and clinical value of a new AED algorithm","volume":"162","author":"de Graaf","year":"2021","journal-title":"Resuscitation"},{"issue":"24","key":"10.1016\/j.compbiomed.2024.108180_bib20","doi-asserted-by":"crossref","DOI":"10.3390\/s21248210","article-title":"Automated condition-based suppression of the CPR artifact in ECG data to make a reliable shock decision for AEDs during CPR","volume":"21","author":"Hajeb-Mohammadalipour","year":"2021","journal-title":"Sensors"},{"key":"10.1016\/j.compbiomed.2024.108180_bib21","unstructured":"\u201cCREI-GARD, A NEW CONCEPT IN COMPUTERIZED ARRHYTHMIA MONITORING SYSTEMS. | Scholars@Duke\u201d https:\/\/scholars.duke.edu\/display\/pub754604 (accessed June. 7, 2023).."},{"issue":"23","key":"10.1016\/j.compbiomed.2024.108180_bib22","doi-asserted-by":"crossref","first-page":"e215","DOI":"10.1161\/01.CIR.101.23.e215","article-title":"PhysioBank, PhysioToolkit, and PhysioNet","volume":"101","author":"Goldberger","year":"2000","journal-title":"Circulation"},{"issue":"2","key":"10.1016\/j.compbiomed.2024.108180_bib23","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1007\/s13246-016-0425-2","article-title":"A new method without reference channels used for ventricular fibrillation detection during cardiopulmonary resuscitation","volume":"39","author":"Yu","year":"2016","journal-title":"Australas. Phys. Eng. Sci. Med."},{"issue":"9","key":"10.1016\/j.compbiomed.2024.108180_bib24","doi-asserted-by":"crossref","first-page":"4500","DOI":"10.3390\/s23094500","article-title":"Deep learning strategy for sliding ECG analysis during cardiopulmonary resuscitation: influence of the hands-off time on accuracy","volume":"23","author":"Krasteva","year":"2023","journal-title":"Sensors"},{"issue":"12","key":"10.1016\/j.compbiomed.2024.108180_bib25","doi-asserted-by":"crossref","DOI":"10.3390\/s21124105","article-title":"Optimization of end-to-end convolutional neural networks for analysis of out-of-hospital cardiac arrest rhythms during cardiopulmonary resuscitation","volume":"21","author":"Jekova","year":"2021","journal-title":"Sensors"},{"key":"10.1016\/j.compbiomed.2024.108180_bib26","series-title":"\u201cAn Alternative to Derive the Instantaneous Frequency of the Chest Compressions to Suppress the CPR Artifact,\u201d Presented at the Computing in Cardiology","first-page":"545","author":"Ayala","year":"2010"}],"container-title":["Computers in Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010482524002646?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010482524002646?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,10,7]],"date-time":"2024-10-07T16:03:59Z","timestamp":1728317039000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0010482524002646"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":26,"alternative-id":["S0010482524002646"],"URL":"https:\/\/doi.org\/10.1016\/j.compbiomed.2024.108180","relation":{},"ISSN":["0010-4825"],"issn-type":[{"value":"0010-4825","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Enhancing the accuracy of shock advisory algorithms in automated external defibrillators during ongoing cardiopulmonary resuscitation using a cascade of CNNEDs","name":"articletitle","label":"Article Title"},{"value":"Computers in Biology and Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.compbiomed.2024.108180","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"108180"}}