{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,29]],"date-time":"2026-09-29T04:16:25Z","timestamp":1790655385270,"version":"4.1.0"},"reference-count":47,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,2,1]],"date-time":"2025-02-01T00:00:00Z","timestamp":1738368000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,12,11]],"date-time":"2024-12-11T00:00:00Z","timestamp":1733875200000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000857","name":"Loughborough University","doi-asserted-by":"publisher","id":[{"id":"10.13039\/501100000857","id-type":"DOI","asserted-by":"publisher"}]},{"DOI":"10.13039\/501100000266","name":"Engineering and Physical Sciences Research Council","doi-asserted-by":"publisher","award":["EP\/V02910X\/1"],"award-info":[{"award-number":["EP\/V02910X\/1"]}],"id":[{"id":"10.13039\/501100000266","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.fr","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Computers in Biology and Medicine"],"published-print":{"date-parts":[[2025,2]]},"DOI":"10.1016\/j.compbiomed.2024.109512","type":"journal-article","created":{"date-parts":[[2024,12,14]],"date-time":"2024-12-14T11:08:33Z","timestamp":1734174513000},"page":"109512","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["Computational evaluation of interactive dynamics for a full transcatheter aortic valve device in a patient-specific aortic root"],"prefix":"10.1016","volume":"185","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-9375-3559","authenticated-orcid":false,"given":"Jingwen","family":"Zhang","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-5002-0411","authenticated-orcid":false,"given":"Ran","family":"He","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Jia","family":"Wu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Zhihao","family":"Fan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Dong","family":"Liu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Andy","family":"Gleadall","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Liguo","family":"Zhao","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0400-2180","authenticated-orcid":false,"given":"Simin","family":"Li","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.compbiomed.2024.109512_bib1","doi-asserted-by":"crossref","first-page":"3006","DOI":"10.1161\/01.CIR.0000047200.36165.B8","article-title":"Percutaneous transcatheter implantation of an aortic valve prosthesis for calcific aortic stenosis","volume":"106","author":"Cribier","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.compbiomed.2024.109512_bib2","doi-asserted-by":"crossref","first-page":"154","DOI":"10.1016\/j.tcm.2014.10.001","article-title":"Update on transcatheter aortic valve replacement","volume":"25","author":"Abdel-Wahab","year":"2015","journal-title":"Trends Cardiovasc. Med."},{"key":"10.1016\/j.compbiomed.2024.109512_bib3","doi-asserted-by":"crossref","first-page":"9","DOI":"10.14797\/mdcj-8-2-9","article-title":"Next-generation transcatheter heart valves: current trials in europe and the USA","volume":"8","author":"Sinning","year":"2012","journal-title":"Methodist DeBakey Cardiova. J."},{"key":"10.1016\/j.compbiomed.2024.109512_bib4","doi-asserted-by":"crossref","first-page":"2547","DOI":"10.1016\/j.jbiomech.2014.06.007","article-title":"Simulation of transcatheter aortic valve implantation through patient-specific finite element analysis: two clinical cases","volume":"47","author":"Morganti","year":"2014","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2024.109512_bib5","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1007\/s10237-014-0583-7","article-title":"Simulations of transcatheter aortic valve implantation: implications for aortic root rupture","volume":"14","author":"Wang","year":"2015","journal-title":"Biomech. Model. Mechanobiol."},{"key":"10.1016\/j.compbiomed.2024.109512_bib6","doi-asserted-by":"crossref","first-page":"1965","DOI":"10.1016\/j.jbiomech.2012.05.008","article-title":"Patient-specific modeling of biomechanical interaction in transcatheter aortic valve deployment","volume":"45","author":"Wang","year":"2012","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2024.109512_bib7","doi-asserted-by":"crossref","first-page":"2520","DOI":"10.1016\/j.jbiomech.2016.03.036","article-title":"Impact of different aortic valve calcification patterns on the outcome of transcatheter aortic valve implantation: a finite element study","volume":"49","author":"Sturla","year":"2016","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2024.109512_bib8","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ab10c1","article-title":"A patient-specific mass-spring model for biomechanical simulation of aortic root tissue during transcatheter aortic valve implantation","volume":"64","author":"Cristoforetti","year":"2019","journal-title":"Phys. Med. Biol."},{"key":"10.1016\/j.compbiomed.2024.109512_bib9","doi-asserted-by":"crossref","first-page":"183","DOI":"10.1007\/s11517-012-0864-1","article-title":"Patient-specific simulations of transcatheter aortic valve stent implantation","volume":"50","author":"Capelli","year":"2012","journal-title":"Med. Biol. Eng. Comput."},{"key":"10.1016\/j.compbiomed.2024.109512_bib10","doi-asserted-by":"crossref","first-page":"236","DOI":"10.1016\/j.jbiomech.2018.02.017","article-title":"Population-specific material properties of the implantation site for transcatheter aortic valve replacement finite element simulations","volume":"71","author":"Bosi","year":"2018","journal-title":"J. Biomech."},{"issue":"1","key":"10.1016\/j.compbiomed.2024.109512_bib11","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1038\/s41598-020-66899-6","article-title":"A validated computational framework to predict outcomes in TAVI","volume":"10","author":"Bosi","year":"2020","journal-title":"Sci. Rep."},{"issue":"1","key":"10.1016\/j.compbiomed.2024.109512_bib12","doi-asserted-by":"crossref","first-page":"79","DOI":"10.1007\/s10237-018-1069-9","article-title":"The impact of implantation depth of the LotusTM valve on mechanical stress in close proximity to the bundle of His","volume":"18","author":"McGee","year":"2019","journal-title":"Biomech. Model. Mechanobiol."},{"key":"10.1016\/j.compbiomed.2024.109512_bib13","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2024.106650","article-title":"Effect of bioprosthetic leaflet anisotropy on stent dynamics of Transcatheter Aortic Valve Replacement devices","volume":"157","author":"Armfield","year":"2024","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.compbiomed.2024.109512_bib14","doi-asserted-by":"crossref","DOI":"10.1016\/j.cmpb.2022.106912","article-title":"Patient-specific multi-scale design optimization of transcatheter aortic valve stents","volume":"221","author":"Barati","year":"2022","journal-title":"Comput. Methods Progr. Biomed."},{"issue":"6","key":"10.1016\/j.compbiomed.2024.109512_bib15","doi-asserted-by":"crossref","first-page":"1195","DOI":"10.1007\/s10439-014-1008-6","article-title":"An in vitro evaluation of the impact of eccentric deployment on transcatheter aortic valve hemodynamics","volume":"42","author":"Gunning","year":"2014","journal-title":"Ann. Biomed. Eng."},{"issue":"113","key":"10.1016\/j.compbiomed.2024.109512_bib16","doi-asserted-by":"crossref","DOI":"10.1098\/rsif.2015.0737","article-title":"Total ellipse of the heart valve: the impact of eccentric stent distortion on the regional dynamic deformation of pericardial tissue leaflets of a transcatheter aortic valve replacement","volume":"12","author":"Gunning","year":"2015","journal-title":"J. R. Soc. Interface"},{"issue":"2","key":"10.1016\/j.compbiomed.2024.109512_bib17","doi-asserted-by":"crossref","DOI":"10.1007\/s10237-018-1094-8","article-title":"Patient-specific simulation of transcatheter aortic valve replacement: impact of deployment options on paravalvular leakage","volume":"18","author":"Bianchi","year":"2019","journal-title":"Biomech. Model. Mechanobiol."},{"issue":"10","key":"10.1016\/j.compbiomed.2024.109512_bib18","article-title":"Patient-specific computer simulation of transcatheter aortic valve replacement in bicuspid aortic valve morphology","volume":"12","author":"Dowling","year":"2019","journal-title":"Circulation: Cardiov. Imaging"},{"issue":"10","key":"10.1016\/j.compbiomed.2024.109512_bib19","doi-asserted-by":"crossref","DOI":"10.1007\/s11517-019-02012-y","article-title":"Biomechanical modelling of transcatheter aortic valve replacement in a stenotic bicuspid aortic valve: deployments and paravalvular leakage","volume":"57","author":"Lavon","year":"2019","journal-title":"Med. Biol. Eng. Comput."},{"key":"10.1016\/j.compbiomed.2024.109512_bib20","doi-asserted-by":"crossref","DOI":"10.1016\/j.carrev.2022.03.006","article-title":"Durability of surgical and transcatheter aortic bioprostheses. A review of the literature","author":"Casenghi","year":"2022","journal-title":"Cardiovasc. Revascularization Med."},{"key":"10.1016\/j.compbiomed.2024.109512_bib21","series-title":"Abaqus 2020 Documentation","author":"Syst\u00e8mes","year":"2020"},{"key":"10.1016\/j.compbiomed.2024.109512_bib22","doi-asserted-by":"crossref","first-page":"1903","DOI":"10.1007\/s10554-019-01626-5","article-title":"Pediatric heterozygous familial hypercholesterolemia patients have locally increased aortic pulse wave velocity and wall thickness at the aortic root","volume":"35","author":"Tran","year":"2019","journal-title":"Int. J. Cardiovasc. Imag."},{"key":"10.1016\/j.compbiomed.2024.109512_bib23","author":"Williams"},{"key":"10.1016\/j.compbiomed.2024.109512_bib24","doi-asserted-by":"crossref","first-page":"268","DOI":"10.1115\/1.3138417","article-title":"Three-dimensional stress distribution in arteries","volume":"105","author":"Chuong","year":"1983","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.compbiomed.2024.109512_bib25","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1615\/CritRevBiomedEng.v23.i1-2.10","article-title":"Mechanics of the arterial wall: review and directions","volume":"23","author":"Humphrey","year":"1995","journal-title":"Crit. Rev. Biomed. Eng."},{"key":"10.1016\/j.compbiomed.2024.109512_bib26","doi-asserted-by":"crossref","first-page":"1065","DOI":"10.1016\/j.jtcvs.2016.12.016","article-title":"Stent and leaflet stresses in a 26-mm first-generation balloon-expandable transcatheter aortic valve","volume":"153","author":"Xuan","year":"2017","journal-title":"J. Thorac. Cardiovasc. Surg."},{"key":"10.1016\/j.compbiomed.2024.109512_bib27","doi-asserted-by":"crossref","first-page":"905","DOI":"10.1115\/1.2049337","article-title":"Simulated bioprosthetic heart valve deformation under quasi-static loading","volume":"127","author":"Sun","year":"2005","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.compbiomed.2024.109512_bib28","doi-asserted-by":"crossref","first-page":"3663","DOI":"10.1016\/j.jbiomech.2015.08.012","article-title":"Leaflet stress and strain distributions following incomplete transcatheter aortic valve expansion","volume":"48","author":"Abbasi","year":"2015","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2024.109512_bib29","first-page":"81","article-title":"Leaflet mechanical properties of carpentier-edwards perimount magna pericardial aortic bioprostheses: surgical bioprosthetic leaflet biomechanics","volume":"26","author":"Kuang","year":"2017","journal-title":"J. Heart Valve Dis."},{"key":"10.1016\/j.compbiomed.2024.109512_bib30","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1023\/A:1010835316564","article-title":"A new constitutive framework for arterial wall mechanics and a comparative study of material models","volume":"61","author":"Holzapfel","year":"2000","journal-title":"J. Elasticity"},{"key":"10.1016\/j.compbiomed.2024.109512_bib31","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1098\/rsif.2005.0073","article-title":"Hyperelastic modelling of arterial layers with distributed collagen fibre orientations","volume":"3","author":"Gasser","year":"2006","journal-title":"J. R. Soc. Interface"},{"key":"10.1016\/j.compbiomed.2024.109512_bib32","doi-asserted-by":"crossref","first-page":"93","DOI":"10.1016\/j.jmbbm.2012.03.012","article-title":"Layer-specific damage experiments and modeling of human thoracic and abdominal aortas with non-atherosclerotic intimal thickening","volume":"12","author":"Weisbecker","year":"2012","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.compbiomed.2024.109512_bib33","doi-asserted-by":"crossref","first-page":"87","DOI":"10.1016\/j.athoracsur.2011.08.002","article-title":"Comparison of mechanical properties of human ascending aorta and aortic sinuses","volume":"93","author":"Azadani","year":"2012","journal-title":"Ann. Thorac. Surg."},{"key":"10.1016\/j.compbiomed.2024.109512_bib34","doi-asserted-by":"crossref","first-page":"1111","DOI":"10.1093\/ejcts\/ezr163","article-title":"Biomechanical comparison of human pulmonary and aortic roots","volume":"41","author":"Azadani","year":"2012","journal-title":"Eur. J. Cardio. Thorac. Surg."},{"key":"10.1016\/j.compbiomed.2024.109512_bib35","doi-asserted-by":"crossref","first-page":"1482","DOI":"10.1016\/j.athoracsur.2016.08.061","article-title":"Biomechanics of failed pulmonary autografts compared to native aortic roots","volume":"103","author":"Mookhoek","year":"2017","journal-title":"Ann. Thorac. Surg."},{"key":"10.1016\/j.compbiomed.2024.109512_bib36","series-title":"Proceedings of the 2010 IEEE 36th Annual Northeast Bioengineering Conference, NEBEC 2010","article-title":"Differences in mechanical properties between human and porcine aortic root","author":"Martin","year":"2010"},{"key":"10.1016\/j.compbiomed.2024.109512_bib37","doi-asserted-by":"crossref","first-page":"28","DOI":"10.1016\/j.ejcts.2010.08.056","article-title":"Significant differences in the material properties between aged human and porcine aortic tissues","volume":"40","author":"Martin","year":"2011","journal-title":"Eur. J. Cardio. Thorac. Surg."},{"key":"10.1016\/j.compbiomed.2024.109512_bib38","doi-asserted-by":"crossref","first-page":"634","DOI":"10.1016\/j.ejcts.2004.05.043","article-title":"Comparison of biomechanical and structural properties between human aortic and pulmonary valve","volume":"26","author":"Stradins","year":"2004","journal-title":"Eur. J. Cardio. Thorac. Surg. : Offi. J. Europ. Assoc. Cardio-Thoracic Surg."},{"key":"10.1016\/j.compbiomed.2024.109512_bib39","doi-asserted-by":"crossref","first-page":"1501","DOI":"10.1089\/ten.2006.0279","article-title":"The role of collagen cross-links in biomechanical behavior of human aortic heart valve leaflets--relevance for tissue engineering","volume":"13","author":"Balguid","year":"2007","journal-title":"Tissue Eng."},{"key":"10.1016\/j.compbiomed.2024.109512_bib40","doi-asserted-by":"crossref","first-page":"657","DOI":"10.1115\/1.1800557","article-title":"Anisotropic mechanical properties of tissue components in human atherosclerotic plaques","volume":"126","author":"Holzapfel","year":"2004","journal-title":"J. Biomech. Eng."},{"key":"10.1016\/j.compbiomed.2024.109512_bib41","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0234340","article-title":"Experimental and mathematical characterization of coronary polyamide-12 balloon catheter membranes","volume":"15","author":"Geith","year":"2020","journal-title":"PLoS One"},{"key":"10.1016\/j.compbiomed.2024.109512_bib42","doi-asserted-by":"crossref","first-page":"313","DOI":"10.1016\/j.ijcard.2017.11.106","article-title":"Quantitative assessment of paravalvular leakage after transcatheter aortic valve replacement using a patient-specific pulsatile flow model","volume":"258","author":"Tanaka","year":"2018","journal-title":"Int. J. Cardiol."},{"issue":"9","key":"10.1016\/j.compbiomed.2024.109512_bib43","doi-asserted-by":"crossref","DOI":"10.33963\/KP.15522","article-title":"New advances in the prevention of transcatheter aortic valve implantation failure: current and future perspectives","volume":"78","author":"Piroli","year":"2020","journal-title":"Kardiol. Pol."},{"key":"10.1016\/j.compbiomed.2024.109512_bib44","doi-asserted-by":"crossref","first-page":"2513","DOI":"10.1016\/j.jbiomech.2015.10.048","article-title":"Prediction of patient-specific post-operative outcomes of TAVI procedure: the impact of the positioning strategy on valve performance","volume":"49","author":"Morganti","year":"2016","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2024.109512_bib45","article-title":"Ultimate tensile strength and biaxial stress\u2013strain responses of aortic tissues\u2014a clinical-engineering correlation","volume":"10","author":"Dong","year":"2022","journal-title":"Appl. Eng. Sci."},{"issue":"4","key":"10.1016\/j.compbiomed.2024.109512_bib46","doi-asserted-by":"crossref","DOI":"10.1097\/MAT.0000000000000659","article-title":"Radial force: an underestimated parameter in oversizing transcatheter aortic valve replacement prostheses: in vitro analysis with five commercialized valves","volume":"64","author":"Egron","year":"2018","journal-title":"Am. Soc. Artif. Intern. Organs J."},{"issue":"4","key":"10.1016\/j.compbiomed.2024.109512_bib47","doi-asserted-by":"crossref","first-page":"525","DOI":"10.1007\/s10237-023-01789-0","article-title":"On the necessity to include arterial pre-stress in patient-specific simulations of minimally invasive procedures","volume":"23","author":"Ramella","year":"2024","journal-title":"Biomech. Model. Mechanobiol."}],"container-title":["Computers in Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S001048252401597X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S001048252401597X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,3,28]],"date-time":"2025-03-28T14:52:52Z","timestamp":1743173572000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S001048252401597X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,2]]},"references-count":47,"alternative-id":["S001048252401597X"],"URL":"https:\/\/doi.org\/10.1016\/j.compbiomed.2024.109512","relation":{},"ISSN":["0010-4825"],"issn-type":[{"value":"0010-4825","type":"print"}],"subject":[],"published":{"date-parts":[[2025,2]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Computational evaluation of interactive dynamics for a full transcatheter aortic valve device in a patient-specific aortic root","name":"articletitle","label":"Article Title"},{"value":"Computers in Biology and Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.compbiomed.2024.109512","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"109512"}}