{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T21:31:50Z","timestamp":1786570310027,"version":"build-2736575974"},"reference-count":96,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2026,6,15]],"date-time":"2026-06-15T00:00:00Z","timestamp":1781481600000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by\/4.0\/"}],"funder":[{"DOI":"10.13039\/501100000923","name":"Australian Research Council","doi-asserted-by":"publisher","award":["IC180100024"],"award-info":[{"award-number":["IC180100024"]}],"id":[{"id":"10.13039\/501100000923","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Computers in Biology and Medicine"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.compbiomed.2026.111813","type":"journal-article","created":{"date-parts":[[2026,6,17]],"date-time":"2026-06-17T19:50:13Z","timestamp":1781725813000},"page":"111813","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":0,"special_numbering":"C","title":["A TPMS-integrated paediatric proximal femoral osteotomy implant demonstrates structural feasibility and improved load sharing: An in silico proof-of-concept study"],"prefix":"10.1016","volume":"213","author":[{"ORCID":"https:\/\/orcid.org\/0000-0002-7015-0608","authenticated-orcid":false,"given":"Ali","family":"Ebrahimzadeh Dehaghani","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-4217-3087","authenticated-orcid":false,"given":"Alireza Y.","family":"Bavil","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0011-6981","authenticated-orcid":false,"given":"Emmanuel","family":"Eghan-Acquah","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-2659-1844","authenticated-orcid":false,"given":"Zia","family":"Javanbakht","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Martina","family":"Barzan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0824-9682","authenticated-orcid":false,"given":"David G.","family":"Lloyd","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Christopher P.","family":"Carty","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-2442-3326","authenticated-orcid":false,"given":"Stefanie","family":"Feih","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"1","key":"10.1016\/j.compbiomed.2026.111813_bib1","doi-asserted-by":"crossref","DOI":"10.1016\/j.irbm.2025.100919","article-title":"Selected postoperative neck-shaft angle in proximal femoral osteotomy can affect the bone healing: a finite element study","volume":"47","author":"Bavil","year":"2026","journal-title":"IRBM"},{"key":"10.1016\/j.compbiomed.2026.111813_bib2","doi-asserted-by":"crossref","first-page":"2299","DOI":"10.1007\/s00264-012-1643-1","article-title":"The locking compression paediatric hip plate: technical guide and critical analysis","volume":"36","author":"Joeris","year":"2012","journal-title":"Int. Orthop."},{"key":"10.1016\/j.compbiomed.2026.111813_bib3","article-title":"An overview of 3D printed metal implants in orthopedic applications: present and future perspectives","volume":"9","author":"Wu","year":"2023","journal-title":"Heliyon"},{"key":"10.1016\/j.compbiomed.2026.111813_bib4","doi-asserted-by":"crossref","DOI":"10.1016\/j.heliyon.2024.e37818","article-title":"Advanced porous hip implants: a comprehensive review","volume":"10","author":"Ziaie","year":"2024","journal-title":"Heliyon"},{"key":"10.1016\/j.compbiomed.2026.111813_bib5","doi-asserted-by":"crossref","first-page":"42","DOI":"10.1186\/s13018-022-03492-9","article-title":"Additively manufactured controlled porous orthopedic joint replacement designs to reduce bone stress shielding: a systematic review","volume":"18","author":"Safavi","year":"2023","journal-title":"J. Orthop. Surg. Res."},{"key":"10.1016\/j.compbiomed.2026.111813_bib6","doi-asserted-by":"crossref","first-page":"43","DOI":"10.1016\/j.injury.2020.06.044","article-title":"The influence of biomechanical stability on bone healing and fracture-related infection: the legacy of Stephan Perren","volume":"52","author":"Foster","year":"2021","journal-title":"Injury"},{"key":"10.1016\/j.compbiomed.2026.111813_bib7","first-page":"491","article-title":"Assessment of implant stability as a prognostic determinant","volume":"11","author":"Meredith","year":"1998","journal-title":"Int. J. Prosthodont. (IJP)"},{"key":"10.1016\/j.compbiomed.2026.111813_bib8","doi-asserted-by":"crossref","DOI":"10.1016\/j.jbiomech.2022.111057","article-title":"A FE study on the effect of interference fit and coefficient of friction on the micromotions and interface gaps of a cementless PEEK femoral component","volume":"137","author":"Post","year":"2022","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib9","doi-asserted-by":"crossref","DOI":"10.1016\/j.jbiomech.2021.110270","article-title":"Decreased stress shielding with a PEEK femoral total knee prosthesis measured in validated computational models","volume":"118","author":"de Ruiter","year":"2021","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib10","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1007\/s42235-018-0057-1","article-title":"Biomechanical optimization of elastic modulus distribution in porous femoral stem for artificial hip joints","volume":"15","author":"Sun","year":"2018","journal-title":"J. Bionic Eng."},{"key":"10.1016\/j.compbiomed.2026.111813_bib11","doi-asserted-by":"crossref","first-page":"1655","DOI":"10.1016\/S0021-9290(00)00110-X","article-title":"Analysis of a femoral hip prosthesis designed to reduce stress shielding","volume":"33","author":"Joshi","year":"2000","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib12","doi-asserted-by":"crossref","first-page":"141","DOI":"10.1080\/17452759.2017.1307769","article-title":"Metallic bone fixation implants: a novel design approach for reducing the stress shielding phenomenon","volume":"12","author":"Al-Tamimi","year":"2017","journal-title":"Virtual Phys. Prototyp."},{"key":"10.1016\/j.compbiomed.2026.111813_bib13","doi-asserted-by":"crossref","first-page":"769","DOI":"10.1016\/j.bone.2011.06.035","article-title":"Compressive behaviour of child and adult cortical bone","volume":"49","author":"\u00d6hman","year":"2011","journal-title":"Bone"},{"key":"10.1016\/j.compbiomed.2026.111813_bib14","first-page":"124","article-title":"The relationship between stress shielding and bone resorption around total hip stems and the effects of flexible materials","author":"Huiskes","year":"1992","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.compbiomed.2026.111813_bib15","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1146\/annurev.bioeng.8.061505.095721","article-title":"Biomechanical and molecular regulation of bone remodeling","volume":"8","author":"Robling","year":"2006","journal-title":"Annu. Rev. Biomed. Eng."},{"key":"10.1016\/j.compbiomed.2026.111813_bib16","article-title":"Metallic implant removal in children","volume":"25","author":"Peterson","year":"2005","journal-title":"J. Pediatr. Orthop."},{"key":"10.1016\/j.compbiomed.2026.111813_bib17","doi-asserted-by":"crossref","DOI":"10.1142\/S0219519419500519","article-title":"Reducing stress shielding and weight as well as helping to revascularization of the femur by applying honeycomb holes in hip prosthesis","volume":"19","author":"Ebrahimzadeh","year":"2019","journal-title":"J. Mech. Med. Biol."},{"key":"10.1016\/j.compbiomed.2026.111813_bib18","doi-asserted-by":"crossref","DOI":"10.1016\/j.compbiomed.2024.109544","article-title":"Simulated effects of surgical corrections on bone-implant micromotion and implant stresses in paediatric proximal femoral osteotomy","volume":"185","author":"Bavil","year":"2025","journal-title":"Comput. Biol. Med."},{"key":"10.1016\/j.compbiomed.2026.111813_bib19","doi-asserted-by":"crossref","DOI":"10.1016\/j.cmpb.2024.108480","article-title":"Enhancing biomechanical outcomes in proximal femoral osteotomy through optimised blade plate sizing: a neuromusculoskeletal-informed finite element analysis","volume":"257","author":"Eghan-Acquah","year":"2024","journal-title":"Comput. Methods Progr. Biomed."},{"key":"10.1016\/j.compbiomed.2026.111813_bib20","doi-asserted-by":"crossref","DOI":"10.1016\/j.injury.2024.111917","article-title":"The impact of early axial interfragmentary motion on the fracture healing environment: a scoping review","volume":"55","author":"Rechter","year":"2024","journal-title":"Injury"},{"key":"10.1016\/j.compbiomed.2026.111813_bib21","doi-asserted-by":"crossref","DOI":"10.1155\/2011\/836587","article-title":"Titanium-based biomaterials for preventing stress shielding between implant devices and bone","volume":"2011","author":"Niinomi","year":"2011","journal-title":"Int. J. Biomater."},{"key":"10.1016\/j.compbiomed.2026.111813_bib22","doi-asserted-by":"crossref","first-page":"2661","DOI":"10.3390\/polym13162661","article-title":"Optimization of a patient-specific external fixation device for lower limb injuries","volume":"13","author":"Alqahtani","year":"2021","journal-title":"Polymers"},{"key":"10.1016\/j.compbiomed.2026.111813_bib23","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1007\/s10237-019-01240-3","article-title":"Stress analysis in a bone fracture fixed with topology-optimised plates","volume":"19","author":"Al-Tamimi","year":"2020","journal-title":"Biomech. Model. Mechanobiol."},{"key":"10.1016\/j.compbiomed.2026.111813_bib24","doi-asserted-by":"crossref","DOI":"10.1080\/17452759.2024.2391475","article-title":"Topology optimization and biomechanical evaluation of bone plates for tibial bone fractures considering bone healing","volume":"19","author":"Mehboob","year":"2024","journal-title":"Virtual Phys. Prototyp."},{"key":"10.1016\/j.compbiomed.2026.111813_bib25","doi-asserted-by":"crossref","first-page":"339","DOI":"10.18063\/ijb.v7i3.339","article-title":"3D topology optimization and mesh dependency for redesigning locking compression plates aiming to reduce stress shielding","volume":"7","author":"Al-Tamimi","year":"2021","journal-title":"Int J Bioprint"},{"key":"10.1016\/j.compbiomed.2026.111813_bib26","doi-asserted-by":"crossref","first-page":"270","DOI":"10.1557\/mrs2003.79","article-title":"Cellular solids","volume":"28","author":"Gibson","year":"2003","journal-title":"MRS Bull."},{"key":"10.1016\/j.compbiomed.2026.111813_bib27","doi-asserted-by":"crossref","DOI":"10.1016\/j.pmatsci.2021.100918","article-title":"Properties and applications of additively manufactured metallic cellular materials: a review","volume":"125","author":"Du Plessis","year":"2022","journal-title":"Prog. Mater. Sci."},{"key":"10.1016\/j.compbiomed.2026.111813_bib28","doi-asserted-by":"crossref","first-page":"1328","DOI":"10.1016\/j.msec.2017.02.094","article-title":"Metallic powder-bed based 3D printing of cellular scaffolds for orthopaedic implants: a state-of-the-art review on manufacturing, topological design, mechanical properties and biocompatibility","volume":"76","author":"Tan","year":"2017","journal-title":"Mater. Sci. Eng. C"},{"key":"10.1016\/j.compbiomed.2026.111813_bib29","doi-asserted-by":"crossref","first-page":"266","DOI":"10.1080\/17452759.2018.1491713","article-title":"Numerical comparison of lattice unit cell designs for medical implants by additive manufacturing","volume":"13","author":"Du Plessis","year":"2018","journal-title":"Virtual Phys. Prototyp."},{"key":"10.1016\/j.compbiomed.2026.111813_bib30","first-page":"167","article-title":"Topology-mechanical property relationship of 3D printed strut, skeletal, and sheet based periodic metallic cellular materials","volume":"19","author":"Al-Ketan","year":"2018","journal-title":"Addit. Manuf."},{"key":"10.1016\/j.compbiomed.2026.111813_bib31","doi-asserted-by":"crossref","first-page":"1311","DOI":"10.1080\/15376494.2019.1665759","article-title":"Design and simulation analysis of Lattice bone plate based on finite element method","volume":"28","author":"Jia","year":"2021","journal-title":"Mech. Adv. Mater. Struct."},{"key":"10.1016\/j.compbiomed.2026.111813_bib32","doi-asserted-by":"crossref","first-page":"18","DOI":"10.1016\/j.medengphy.2021.04.003","article-title":"A new porous fixation plate design using the topology optimization","volume":"92","author":"Murat","year":"2021","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.compbiomed.2026.111813_bib33","doi-asserted-by":"crossref","DOI":"10.1016\/j.compbiomed.2023.107062","article-title":"Investigation of lattice infill parameters for additively manufactured bone fracture plates to reduce stress shielding","volume":"161","author":"Subasi","year":"2023","journal-title":"Comput. Biol. Med."},{"key":"10.1016\/j.compbiomed.2026.111813_bib34","doi-asserted-by":"crossref","DOI":"10.1002\/cnm.3682","article-title":"The optimal design of 3D-printed lattice bone plate by considering fracture healing mechanism","volume":"39","author":"Xu","year":"2023","journal-title":"Int. J. Numer. Methods Biomed. Eng."},{"key":"10.1016\/j.compbiomed.2026.111813_bib35","doi-asserted-by":"crossref","DOI":"10.1002\/adem.202300911","article-title":"Designing a novel porous fixation plate with a gyroid lattice structure for humerus fractures using a probabilistic approach","volume":"26","author":"Kaymaz","year":"2024","journal-title":"Adv. Eng. Mater."},{"key":"10.1016\/j.compbiomed.2026.111813_bib36","series-title":"Musculoskeletal Research and Basic Science","first-page":"61","article-title":"Mechanical testing standards of orthopedic implants","author":"Demir","year":"2016"},{"key":"10.1016\/j.compbiomed.2026.111813_bib37","doi-asserted-by":"crossref","DOI":"10.1016\/j.measurement.2024.115691","article-title":"A modified testing method based on ASTM F382 considering the practical physiological loading and boundary conditions applying on bone plates","volume":"241","author":"Chen","year":"2025","journal-title":"Measurement"},{"key":"10.1016\/j.compbiomed.2026.111813_bib38","series-title":"Standard Guide for Total Knee Replacement Loading Profiles","year":"2023"},{"key":"10.1016\/j.compbiomed.2026.111813_bib39","series-title":"Loading and Displacement Parameters for Wear-Testing Machines with Displacement Control and Corresponding Environmental Conditions for Test","article-title":"Implants for surgery\u2014wear of total knee-joint prostheses","year":"2014"},{"key":"10.1016\/j.compbiomed.2026.111813_bib40","series-title":"2020 3rd International Conference on Engineering Technology and its Applications (IICETA)","first-page":"220","article-title":"Testing mechanical behaviour of bone-plate construct","author":"Abed","year":"2020"},{"key":"10.1016\/j.compbiomed.2026.111813_bib41","series-title":"Standard Specification and Test Methods for Metallic Medical Bone Screws","year":"2021"},{"key":"10.1016\/j.compbiomed.2026.111813_bib42","series-title":"Test Method for Metallic Bone Plates","first-page":"382","author":"Specification","year":"1999"},{"key":"10.1016\/j.compbiomed.2026.111813_bib43","unstructured":"ASTM F382-17, Standard Specification and Test Method for Metallic Bone Plates. ASTM International. ."},{"key":"10.1016\/j.compbiomed.2026.111813_bib44","series-title":"Standard Guide for Total Knee Replacement Loading Profiles","year":"2017"},{"key":"10.1016\/j.compbiomed.2026.111813_bib45","series-title":"Loading and Displacement Parameters for Wear-Testing Machines with Displacement Control and Corresponding Environmental Conditions for Test","article-title":"Implants for surgery\u2014wear of total knee-joint prostheses","year":"2014"},{"issue":"4","key":"10.1016\/j.compbiomed.2026.111813_bib46","doi-asserted-by":"crossref","first-page":"842","DOI":"10.1002\/jor.26043","article-title":"Effect of postoperative neck\u2010shaft and anteversion angles on biomechanical outcomes in proximal femoral osteotomy: an in silico study","volume":"43","author":"Bavil","year":"2025","journal-title":"J. Orthop. Res."},{"key":"10.1016\/j.compbiomed.2026.111813_bib47","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-024-61305-x","article-title":"Effect of different constraining boundary conditions on simulated femoral stresses and strains during gait","volume":"14","author":"Bavil","year":"2024","journal-title":"Sci. Rep."},{"key":"10.1016\/j.compbiomed.2026.111813_bib48","doi-asserted-by":"crossref","first-page":"167","DOI":"10.1016\/j.artd.2020.11.022","article-title":"Biomechanical behavior of an hydroxyapatite-coated traditional hip stem and a short one of similar design: comparative study using finite element analysis","volume":"7","author":"G\u00f3mez-Vallejo","year":"2021","journal-title":"Arthroplast Today"},{"key":"10.1016\/j.compbiomed.2026.111813_bib49","doi-asserted-by":"crossref","first-page":"398","DOI":"10.1002\/ar.1049","article-title":"From Wolff's law to the Utah paradigm: insights about bone physiology and its clinical applications","volume":"262","author":"Frost","year":"2001","journal-title":"Anat. Rec."},{"key":"10.1016\/j.compbiomed.2026.111813_bib50","doi-asserted-by":"crossref","DOI":"10.1002\/adem.202400518","article-title":"Multifunctional design of triply periodic minimal surface structures for temporary pediatric fixation devices","volume":"27","author":"Ebrahimzadeh Dehaghani","year":"2025","journal-title":"Adv. Eng. Mater."},{"key":"10.1016\/j.compbiomed.2026.111813_bib51","first-page":"505","article-title":"Energy absorption characteristics of metallic triply periodic minimal surface sheet structures under compressive loading","volume":"23","author":"Zhang","year":"2018","journal-title":"Addit. Manuf."},{"key":"10.1016\/j.compbiomed.2026.111813_bib52","doi-asserted-by":"crossref","first-page":"62","DOI":"10.1016\/j.polymer.2017.11.049","article-title":"Insights into the mechanical properties of several triply periodic minimal surface lattice structures made by polymer additive manufacturing","volume":"152","author":"Maskery","year":"2018","journal-title":"Polymer"},{"key":"10.1016\/j.compbiomed.2026.111813_bib53","doi-asserted-by":"crossref","first-page":"2483","DOI":"10.1016\/j.jbiomech.2008.05.017","article-title":"An accurate estimation of bone density improves the accuracy of subject-specific finite element models","volume":"41","author":"Schileo","year":"2008","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib54","doi-asserted-by":"crossref","first-page":"2457","DOI":"10.1016\/j.jbiomech.2005.07.018","article-title":"Subject-specific finite element models of long bones: an in vitro evaluation of the overall accuracy","volume":"39","author":"Taddei","year":"2006","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib55","doi-asserted-by":"crossref","first-page":"2034","DOI":"10.1016\/j.jbiomech.2015.03.027","article-title":"Developing CT based computational models of pediatric femurs","volume":"48","author":"Li","year":"2015","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib56","doi-asserted-by":"crossref","first-page":"777","DOI":"10.1016\/S0021-9290(03)00011-3","article-title":"The primary stability of a cementless stem varies between subjects as much as between activities","volume":"36","author":"Pancanti","year":"2003","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib57","doi-asserted-by":"crossref","first-page":"1016","DOI":"10.1259\/0007-1285-46-552-1016","article-title":"Computerized transverse axial scanning (tomography). 1. Description of system","volume":"46","author":"Hounsfield","year":"1973","journal-title":"Br. J. Radiol."},{"key":"10.1016\/j.compbiomed.2026.111813_bib58","doi-asserted-by":"crossref","first-page":"1023","DOI":"10.1259\/0007-1285-46-552-1023","article-title":"Computerized transverse axial scanning (tomography). 2. Clinical application","volume":"46","author":"Ambrose","year":"1973","journal-title":"Br. J. Radiol."},{"key":"10.1016\/j.compbiomed.2026.111813_bib59","doi-asserted-by":"crossref","first-page":"10442","DOI":"10.1007\/s10853-018-2322-4","article-title":"Superior strength and ductility of 316L stainless steel with heterogeneous lamella structure","volume":"53","author":"Li","year":"2018","journal-title":"J. Mater. Sci."},{"key":"10.1016\/j.compbiomed.2026.111813_bib60","article-title":"Surgical parameters influence paediatric knee kinematics and cartilage stresses in anterior cruciate ligament reconstruction: navigating subject-specific variability using neuromusculoskeletal-finite element modelling analysis","author":"Dastgerdi","year":"2024","journal-title":"Knee Surg. Sports Traumatol. Arthrosc."},{"key":"10.1016\/j.compbiomed.2026.111813_bib61","doi-asserted-by":"crossref","DOI":"10.1016\/j.cmpb.2024.108132","article-title":"Sensitivity analysis of paediatric knee kinematics to the graft surgical parameters during anterior cruciate ligament reconstruction: a sequentially linked neuromusculoskeletal-finite element analysis","volume":"248","author":"Dastgerdi","year":"2024","journal-title":"Comput. Methods Progr. Biomed."},{"key":"10.1016\/j.compbiomed.2026.111813_bib62","doi-asserted-by":"crossref","first-page":"3026","DOI":"10.1038\/s41598-020-59602-2","article-title":"EMG-assisted muscle force driven finite element model of the knee joint with fibril-reinforced poroelastic cartilages and menisci","volume":"10","author":"Esrafilian","year":"2020","journal-title":"Sci. Rep."},{"key":"10.1016\/j.compbiomed.2026.111813_bib63","doi-asserted-by":"crossref","first-page":"2860","DOI":"10.1109\/TBME.2022.3156018","article-title":"An EMG-assisted muscle-force driven finite element analysis pipeline to investigate Joint- and tissue-level mechanical responses in functional activities: towards a rapid assessment toolbox","volume":"69","author":"Esrafilian","year":"2022","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.compbiomed.2026.111813_bib64","doi-asserted-by":"crossref","first-page":"1940","DOI":"10.1109\/TBME.2007.901024","article-title":"OpenSim: open-source software to create and analyze dynamic simulations of movement","volume":"54","author":"Delp","year":"2007","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.compbiomed.2026.111813_bib65","doi-asserted-by":"crossref","first-page":"2068","DOI":"10.1109\/TBME.2016.2586891","article-title":"Full-body musculoskeletal model for muscle-driven simulation of human gait","volume":"63","author":"Rajagopal","year":"2016","journal-title":"IEEE Trans. Biomed. Eng."},{"key":"10.1016\/j.compbiomed.2026.111813_bib66","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1016\/j.jbiomech.2018.08.023","article-title":"Subject-specific calibration of neuromuscular parameters enables neuromusculoskeletal models to estimate physiologically plausible hip joint contact forces in healthy adults","volume":"80","author":"Hoang","year":"2018","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib67","doi-asserted-by":"crossref","first-page":"3929","DOI":"10.1016\/j.jbiomech.2015.09.021","article-title":"CEINMS: a toolbox to investigate the influence of different neural control solutions on the prediction of muscle excitation and joint moments during dynamic motor tasks","volume":"48","author":"Pizzolato","year":"2015","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib68","doi-asserted-by":"crossref","first-page":"96","DOI":"10.1016\/j.compbiomed.2014.04.002","article-title":"Reconstruction of the biomechanical transfer path of femoral head necrosis: a subject-specific finite element investigation","volume":"52","author":"Zhou","year":"2014","journal-title":"Comput. Biol. Med."},{"key":"10.1016\/j.compbiomed.2026.111813_bib69","doi-asserted-by":"crossref","first-page":"1089","DOI":"10.1016\/j.medengphy.2006.11.005","article-title":"The number of screws, bone quality, and friction coefficient affect acetabular cup stability","volume":"29","author":"Hsu","year":"2007","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.compbiomed.2026.111813_bib70","doi-asserted-by":"crossref","first-page":"1141","DOI":"10.1243\/09544119JEIM799","article-title":"A biomechanical evaluation of orthopaedic implants for hip fractures by finite element analysis and in-vitro tests","volume":"224","author":"Eberle","year":"2010","journal-title":"Proc. Inst. Mech. Eng. H"},{"key":"10.1016\/j.compbiomed.2026.111813_bib71","doi-asserted-by":"crossref","first-page":"331","DOI":"10.1515\/bmt-2015-0091","article-title":"Biomechanical effect of different femoral neck blade position on the fixation of intertrochanteric fracture: a finite element analysis","volume":"61","author":"Lee","year":"2016","journal-title":"Biomed. Tech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib72","doi-asserted-by":"crossref","first-page":"858","DOI":"10.3390\/medicina58070858","article-title":"Continuous implant load monitoring to assess bone healing status\u2014evidence from animal testing","volume":"58","author":"Windolf","year":"2022","journal-title":"Medicina"},{"key":"10.1016\/j.compbiomed.2026.111813_bib73","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2025.106908","article-title":"Evaluation of boundary conditions for predicting femoral bone-implant mechanics during gait in the absence of comprehensive medical imaging","volume":"164","author":"Eghan-Acquah","year":"2025","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.compbiomed.2026.111813_bib74","doi-asserted-by":"crossref","DOI":"10.1038\/s41598-021-90142-5","article-title":"The limit of tolerable micromotion for implant osseointegration: a systematic review","volume":"11","author":"Kohli","year":"2021","journal-title":"Sci. Rep."},{"key":"10.1016\/j.compbiomed.2026.111813_bib75","doi-asserted-by":"crossref","first-page":"1748","DOI":"10.1016\/j.compbiomed.2013.07.032","article-title":"Prediction of stress shielding around an orthopedic screw: using stress and strain energy density as mechanical stimuli","volume":"43","author":"Haase","year":"2013","journal-title":"Comput. Biol. Med."},{"key":"10.1016\/j.compbiomed.2026.111813_bib76","series-title":"Stress-Related Bone Resorption, Joint Replacement and Bone Resorption: Pathology, Biomaterials, and Clinical Practice","first-page":"375","author":"Bobyn","year":"2006"},{"key":"10.1016\/j.compbiomed.2026.111813_bib77","first-page":"202","article-title":"Determinants of stress shielding: design versus materials versus interface","author":"Sumner","year":"1992","journal-title":"Clin. Orthop. Relat. Res."},{"key":"10.1016\/j.compbiomed.2026.111813_bib78","doi-asserted-by":"crossref","first-page":"1481","DOI":"10.1016\/j.medengphy.2016.09.018","article-title":"Stress shielding in periprosthetic bone following a total knee replacement: effects of implant material, design and alignment","volume":"38","author":"Zhang","year":"2016","journal-title":"Med. Eng. Phys."},{"key":"10.1016\/j.compbiomed.2026.111813_bib79","series-title":"Bone Mechanics Handbook","author":"Cowin","year":"2001"},{"key":"10.1016\/j.compbiomed.2026.111813_bib80","doi-asserted-by":"crossref","first-page":"1135","DOI":"10.1016\/0021-9290(87)90030-3","article-title":"Adaptive bone-remodeling theory applied to prosthetic-design analysis","volume":"20","author":"Huiskes","year":"1987","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib81","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1080\/03091902.2024.2355319","article-title":"A numerical investigation of stress, strain, and bone density changes due to bone remodelling in the talus bone following total ankle arthroplasty","volume":"48","author":"Mondal","year":"2024","journal-title":"J. Med. Eng. Technol."},{"key":"10.1016\/j.compbiomed.2026.111813_bib82","doi-asserted-by":"crossref","first-page":"707","DOI":"10.2106\/00004623-199705000-00010","article-title":"In vivo skeletal responses to porous-surfaced implants subjected to small induced motions","volume":"79","author":"Jasty","year":"1997","journal-title":"J. Bone Joint Surg. Am."},{"key":"10.1016\/j.compbiomed.2026.111813_bib83","doi-asserted-by":"crossref","DOI":"10.1098\/rsif.2019.0259","article-title":"Biomechanical behaviours of the bone\u2013implant interface: a review","volume":"16","author":"Gao","year":"2019","journal-title":"J. R. Soc. Interface"},{"key":"10.1016\/j.compbiomed.2026.111813_bib84","doi-asserted-by":"crossref","first-page":"1836","DOI":"10.1016\/j.jbiomech.2016.04.021","article-title":"Implicit modeling of screw threads for efficient finite element analysis of complex bone-implant systems","volume":"49","author":"Inzana","year":"2016","journal-title":"J. Biomech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib85","doi-asserted-by":"crossref","first-page":"335","DOI":"10.3390\/sym10080335","article-title":"Finite element study of a threaded fastening: the case of surgical screws in bone","volume":"10","author":"L\u00f3pez-Campos","year":"2018","journal-title":"Symmetry"},{"key":"10.1016\/j.compbiomed.2026.111813_bib86","doi-asserted-by":"crossref","first-page":"311","DOI":"10.1007\/BF02344213","article-title":"Computational simulations of stress shielding and bone resorption around existing and computer-designed orthopaedic screws","volume":"40","author":"Gefen","year":"2002","journal-title":"Med. Biol. Eng. Comput."},{"key":"10.1016\/j.compbiomed.2026.111813_bib87","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1007\/s40964-021-00210-5","article-title":"Biomorphic porous Ti6Al4V gyroid scaffolds for bone implant applications fabricated by selective laser melting","volume":"6","author":"Hameed","year":"2021","journal-title":"Progr. Addit. Manuf."},{"key":"10.1016\/j.compbiomed.2026.111813_bib88","doi-asserted-by":"crossref","first-page":"4993","DOI":"10.1007\/s11665-021-05580-z","article-title":"3D-Printed Ti6Al4V scaffolds with graded triply periodic minimal surface structure for bone tissue engineering","volume":"30","author":"Liao","year":"2021","journal-title":"J. Mater. Eng. Perform."},{"key":"10.1016\/j.compbiomed.2026.111813_bib89","doi-asserted-by":"crossref","DOI":"10.1016\/j.jmbbm.2021.104608","article-title":"Mechanical interaction between additive-manufactured metal lattice structures and bone in compression: implications for stress shielding of orthopaedic implants","volume":"121","author":"Liverani","year":"2021","journal-title":"J. Mech. Behav. Biomed. Mater."},{"key":"10.1016\/j.compbiomed.2026.111813_bib90","series-title":"Frontiers in Biomedical Devices","article-title":"Solid-lattice hip prosthesis design: applying topology and lattice optimization to reduce stress shielding from hip implants","author":"He","year":"2018"},{"key":"10.1016\/j.compbiomed.2026.111813_bib91","doi-asserted-by":"crossref","DOI":"10.1016\/j.matdes.2025.115001","article-title":"Review on lower limb bone fracture fixation: biomechanics, design, and advancements in additive manufacturing for implants","volume":"260","author":"Mehboob","year":"2025","journal-title":"Mater. Des."},{"key":"10.1016\/j.compbiomed.2026.111813_bib92","doi-asserted-by":"crossref","DOI":"10.1016\/j.matdes.2025.114060","article-title":"Computational modelling and optimization of porous plates for mandibular fracture fixation accounting for bone healing","volume":"254","author":"Mehboob","year":"2025","journal-title":"Mater. Des."},{"key":"10.1016\/j.compbiomed.2026.111813_bib93","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1016\/0268-0033(88)90065-4","article-title":"Stress protection osteopenia due to rigid plating","volume":"3","author":"Gilbert","year":"1988","journal-title":"Clin. BioMech."},{"key":"10.1016\/j.compbiomed.2026.111813_bib94","series-title":"Proximal Femoral Osteotomy Advice and Exercises","author":"Royal Berkshire","year":"2024"},{"key":"10.1016\/j.compbiomed.2026.111813_bib95","doi-asserted-by":"crossref","first-page":"3759","DOI":"10.1038\/s41467-026-70309-2","article-title":"Combined physical and pharmacological anabolic osteoporosis therapies increase bone response and mechanoregulation in female mice","volume":"17","author":"Schulte","year":"2026","journal-title":"Nat. Commun."},{"key":"10.1016\/j.compbiomed.2026.111813_bib96","first-page":"1","article-title":"On the pathogenesis of osteogenesis imperfecta: some insights of the Utah paradigm of skeletal physiology","volume":"3","author":"Frost","year":"2003","journal-title":"J. Musculoskelet. Neuronal Interact."}],"container-title":["Computers in Biology and Medicine"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S001048252600377X?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S001048252600377X?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,8,12]],"date-time":"2026-08-12T21:12:07Z","timestamp":1786569127000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S001048252600377X"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":96,"alternative-id":["S001048252600377X"],"URL":"https:\/\/doi.org\/10.1016\/j.compbiomed.2026.111813","relation":{},"ISSN":["0010-4825"],"issn-type":[{"value":"0010-4825","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"A TPMS-integrated paediatric proximal femoral osteotomy implant demonstrates structural feasibility and improved load sharing: An in silico proof-of-concept study","name":"articletitle","label":"Article Title"},{"value":"Computers in Biology and Medicine","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.compbiomed.2026.111813","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Authors. Published by Elsevier Ltd.","name":"copyright","label":"Copyright"}],"article-number":"111813"}}