{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,12,12]],"date-time":"2025-12-12T13:17:41Z","timestamp":1765545461556},"reference-count":20,"publisher":"Elsevier BV","issue":"3","license":[{"start":{"date-parts":[[2007,9,1]],"date-time":"2007-09-01T00:00:00Z","timestamp":1188604800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"}],"content-domain":{"domain":[],"crossmark-restriction":false},"short-container-title":["Contraception"],"published-print":{"date-parts":[[2007,9]]},"DOI":"10.1016\/j.contraception.2007.04.010","type":"journal-article","created":{"date-parts":[[2007,8,4]],"date-time":"2007-08-04T11:11:35Z","timestamp":1186225895000},"page":"233-237","source":"Crossref","is-referenced-by-count":16,"title":["Release behavior of copper ion in a novel contraceptive composite"],"prefix":"10.1016","volume":"76","author":[{"given":"Juan","family":"Li","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Jinping","family":"Suo","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xunbin","family":"Huang","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Chang","family":"Ye","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Xiwang","family":"Wu","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.contraception.2007.04.010_bib1","doi-asserted-by":"crossref","first-page":"363","DOI":"10.1023\/A:1006760928734","article-title":"Contraceptive methods used and preferred by men and women","volume":"15","author":"Kirkkola","year":"1999","journal-title":"Adv Contracept"},{"key":"10.1016\/j.contraception.2007.04.010_bib2","doi-asserted-by":"crossref","first-page":"45","DOI":"10.1023\/A:1006575610716","article-title":"Non-physician insertion of IUDs: clinical outcomes among TCu380A insertions in three developing-country clinics","volume":"14","author":"Farr","year":"1998","journal-title":"Adv Contracept"},{"key":"10.1016\/j.contraception.2007.04.010_bib3","doi-asserted-by":"crossref","first-page":"235","DOI":"10.1016\/S0010-7824(02)00480-8","article-title":"Uterine factors and risk of pregnancy in IUD users: a nested case-control study","volume":"67","author":"Avecilla-Palau","year":"2003","journal-title":"Contraception"},{"key":"10.1016\/j.contraception.2007.04.010_bib4","doi-asserted-by":"crossref","first-page":"391","DOI":"10.1023\/A:1011288701499","article-title":"Characterization of copper corrosion products originated in simulated uterine fluids and on packaged intrauterine devices","volume":"12","author":"Bastidas","year":"2001","journal-title":"J Mater Sci Mater Med"},{"key":"10.1016\/j.contraception.2007.04.010_bib5","doi-asserted-by":"crossref","first-page":"179","DOI":"10.1023\/A:1006793231274","article-title":"Characteristics of copper corrosion in simulated uterine fluid in the presence of protein","volume":"15","author":"Zhu","year":"1999","journal-title":"Adv Contracept"},{"key":"10.1016\/j.contraception.2007.04.010_bib6","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1023\/A:1006594818470","article-title":"Effect of stainless steel on corrosion behavior of copper in a copper-bearing intrauterine device","volume":"14","author":"Xue","year":"1998","journal-title":"Adv Contracept"},{"key":"10.1016\/j.contraception.2007.04.010_bib7","doi-asserted-by":"crossref","first-page":"29","DOI":"10.1023\/A:1006679427572","article-title":"Does the intrauterine device carry the risk of immunity to sperm?","volume":"15","author":"Vural","year":"1999","journal-title":"Adv Contracept"},{"key":"10.1016\/j.contraception.2007.04.010_bib8","doi-asserted-by":"crossref","first-page":"69","DOI":"10.1016\/S0009-8981(03)00124-4","article-title":"Characterization of copper in uterine fluid of patients who use the copper T-380A intrauterine device","volume":"332","author":"Arancibia","year":"2003","journal-title":"Clin Chim Acta"},{"key":"10.1016\/j.contraception.2007.04.010_bib9","doi-asserted-by":"crossref","first-page":"635","DOI":"10.1016\/0010-938X(95)00154-C","article-title":"The corrosion behavior of copper in simulated uterine fluid","volume":"38","author":"Zhang","year":"1996","journal-title":"Corros Sci"},{"key":"10.1016\/j.contraception.2007.04.010_bib10","doi-asserted-by":"crossref","first-page":"49","DOI":"10.1016\/S0010-7824(97)00207-2","article-title":"Corrosion behavior of copper in a copper bearing intrauterine device in the presence of indomethacin","volume":"57","author":"Xue","year":"1998","journal-title":"Contraception"},{"key":"10.1016\/j.contraception.2007.04.010_bib11","doi-asserted-by":"crossref","first-page":"427","DOI":"10.1016\/S0010-938X(02)00123-3","article-title":"Copper corrosion inhibition by triphenylmethane derivations in sulphuric acid media","volume":"45","author":"Bastidas","year":"2003","journal-title":"Corros Sci"},{"key":"10.1016\/j.contraception.2007.04.010_bib12","doi-asserted-by":"crossref","first-page":"667","DOI":"10.1016\/S0142-9612(01)00154-5","article-title":"Influence of pH and oxygen on copper corrosion in simulated uterine fluid","volume":"23","author":"Mora","year":"2002","journal-title":"Biomaterials"},{"key":"10.1016\/j.contraception.2007.04.010_bib13","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1016\/S0378-5173(97)00402-X","article-title":"Mechanism of sustained drug release in diffusion-controlled polymer matrix \u2014 application of percolation theory","volume":"170","author":"Xu","year":"1998","journal-title":"Int J Pharm"},{"key":"10.1016\/j.contraception.2007.04.010_bib14","doi-asserted-by":"crossref","first-page":"2671","DOI":"10.1016\/j.biomaterials.2004.08.003","article-title":"Corrosion behavior of copper\/LDPE nanocomposites in simulated uterine solution","volume":"26","author":"Cai","year":"2005","journal-title":"Biomaterials"},{"key":"10.1016\/j.contraception.2007.04.010_bib15","doi-asserted-by":"crossref","first-page":"1371","DOI":"10.1016\/S0142-9612(99)00040-X","article-title":"Highly crosslinked, PEG-containing copolymers for sustained solute delivery","volume":"20","author":"Scott","year":"1999","journal-title":"Biomaterials"},{"key":"10.1016\/j.contraception.2007.04.010_bib16","doi-asserted-by":"crossref","first-page":"15","DOI":"10.1016\/S0939-6411(97)00113-6","article-title":"Drug diffusion and binding in ionizable interpenetrating networks from poly (vinyl alcohol) and poly (acrylic acid)","volume":"46","author":"Peppas","year":"1998","journal-title":"Eur J Pharm Biopharm"},{"key":"10.1016\/j.contraception.2007.04.010_bib17","doi-asserted-by":"crossref","first-page":"133","DOI":"10.1002\/(SICI)1097-4628(19991003)74:1<133::AID-APP16>3.0.CO;2-N","article-title":"Properties and structure of poly (vinyl alcohol)\/silica composites","volume":"74","author":"Nakane","year":"1999","journal-title":"J Appl Polym Sci"},{"key":"10.1016\/j.contraception.2007.04.010_bib18","doi-asserted-by":"crossref","first-page":"75","DOI":"10.1016\/S0928-4931(98)00043-5","article-title":"Physical properties and structure of organic\u2013inorganic hybrid materials produced by sol-gel process","volume":"6","author":"Shoichiro","year":"1998","journal-title":"Mat Sci Eng C"},{"key":"10.1016\/j.contraception.2007.04.010_bib19","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/S0010-7824(00)00124-4","article-title":"Copper corrosion-simulated uterine solutions","volume":"61","author":"Bastidas","year":"2000","journal-title":"Contraception"},{"key":"10.1016\/j.contraception.2007.04.010_bib20","doi-asserted-by":"crossref","first-page":"157","DOI":"10.1016\/S0168-3659(00)00341-2","article-title":"Understanding drug release from poly(ethylene oxide)-b-poly(propylene oxide)-b-poly(ethylene oxide) gels","volume":"70","author":"Anderson","year":"2001","journal-title":"J Control Release"}],"container-title":["Contraception"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010782407001771?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0010782407001771?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2019,1,5]],"date-time":"2019-01-05T12:23:02Z","timestamp":1546690982000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0010782407001771"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2007,9]]},"references-count":20,"journal-issue":{"issue":"3","published-print":{"date-parts":[[2007,9]]}},"alternative-id":["S0010782407001771"],"URL":"https:\/\/doi.org\/10.1016\/j.contraception.2007.04.010","relation":{},"ISSN":["0010-7824"],"issn-type":[{"value":"0010-7824","type":"print"}],"subject":[],"published":{"date-parts":[[2007,9]]}}}