{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,5,1]],"date-time":"2026-05-01T19:09:39Z","timestamp":1777662579500,"version":"3.51.4"},"reference-count":36,"publisher":"Elsevier BV","issue":"12","license":[{"start":{"date-parts":[[2022,12,1]],"date-time":"2022-12-01T00:00:00Z","timestamp":1669852800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,12,1]],"date-time":"2022-12-01T00:00:00Z","timestamp":1669852800000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Current Problems in Cardiology"],"published-print":{"date-parts":[[2022,12]]},"DOI":"10.1016\/j.cpcardiol.2022.101349","type":"journal-article","created":{"date-parts":[[2022,8,14]],"date-time":"2022-08-14T17:28:56Z","timestamp":1660498136000},"page":"101349","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Catheter Ablation of Well Tolerated Ventricular Tachycardia in Patients With Structural Heart Disease and Without Automatic Defibrillator Implantation: Long Term Follow-up"],"prefix":"10.1016","volume":"47","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-4454-1864","authenticated-orcid":false,"given":"Laura Sofia","family":"Cardelli","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gaetano","family":"Barbato","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Valeria","family":"Carinci","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Francesco","family":"Pergolini","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Enri","family":"Leci","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Gianni","family":"Casella","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.cpcardiol.2022.101349_bib0001","doi-asserted-by":"crossref","DOI":"10.1016\/0033-0620(89)90029-7","article-title":"The efficacy of amiodarone in the treatment of ventricular tachycardia or ventricular fibrillation","volume":"31","author":"Greene","year":"1989","journal-title":"Prog Cardiovasc Dis"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0002","doi-asserted-by":"crossref","DOI":"10.1016\/0002-8703(91)90013-8","article-title":"Long-term follow-up after sustained monomorphic ventricular tachycardia: Causes, pump failure, and empiric antiarrhythmic therapy that modify survival","volume":"121","author":"Leclercq","year":"1991","journal-title":"Am Heart J"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0003","article-title":"A Comparison of Seven Antiarrhythmic Drugs in Patients with Ventricular Tachyarrhythmias","volume":"329","author":"Mason","year":"1993","journal-title":"N Engl J Med"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0004","doi-asserted-by":"crossref","unstructured":"Priori SG, Blomstr\u00f6 M- Lundqvist C. ESC Guidelines 2015 ESC guidelines for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death the task force for the management of patients with ventricular arrhythmias and the prevention of sudden cardiac death of the European Society of Cardiology (ESC) Endorsed by: Association for European Paediatric and Congenital Cardiology (AEPC). Published online 2015. https:\/\/doi.org\/10.1093\/eurheartj\/ehv316.","DOI":"10.1093\/eurheartj\/ehv316"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0005","article-title":"ACC\/AHA\/HRS 2008 guidelines for device-based therapy of cardiac rhythm abnormalities","volume":"117","author":"Epstein","year":"2008","journal-title":"Circulation"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0006","doi-asserted-by":"crossref","DOI":"10.1161\/01.CIR.102.7.748","article-title":"Randomized comparison of antiarrhythmic drug therapy with implantable defibrillators in patients resuscitated from cardiac arrest","volume":"102","author":"Kuck","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0007","doi-asserted-by":"crossref","DOI":"10.1161\/01.CIR.101.11.1297","article-title":"Canadian Implantable Defibrillator Study (CIDS)","volume":"101","author":"Connolly","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0008","doi-asserted-by":"crossref","first-page":"1576","DOI":"10.1056\/NEJM199711273372202","article-title":"A comparison of antiarrhythmic-drug therapy with implantable defibrillators in patients resuscitated from near-fatal ventricular arrhythmias","volume":"337","year":"1997","journal-title":"N Engl J Med."},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0009","doi-asserted-by":"crossref","DOI":"10.1053\/euhj.2000.2476","article-title":"Meta-analysis of the implantable cardioverter defibrillator secondary prevention trials","volume":"21","author":"Connolly","year":"2000","journal-title":"Eur Heart J"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0010","doi-asserted-by":"crossref","first-page":"747","DOI":"10.1093\/oxfordjournals.eurheartj.a059559","article-title":"The value of the clinical history to assess prognosis of patients with ventricular tachycardia or ventricular fibrillation after myocardial infarction","volume":"10","author":"Brugada","year":"1989","journal-title":"Eur Heart J"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0011","doi-asserted-by":"crossref","first-page":"442","DOI":"10.1016\/0735-1097(89)90525-1","article-title":"Long-term results of amiodarone therapy in patients with recurrent sustained ventricular tachycardia or ventricular fibrillation","volume":"13","author":"Herre","year":"1989","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0012","doi-asserted-by":"crossref","DOI":"10.1016\/S0735-1097(02)01784-9","article-title":"Sudden death in patients with implantable cardioverter defibrillators","volume":"39","author":"Mitchell","year":"2002","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0013","doi-asserted-by":"crossref","first-page":"2657","DOI":"10.1056\/NEJMoa065457","article-title":"Prophylactic catheter ablation for the prevention of defibrillator therapy","volume":"357","author":"Reddy","year":"2007","journal-title":"N Engl J Med"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0014","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0140-6736(09)61755-4","article-title":"Catheter ablation of stable ventricular tachycardia before defibrillator implantation in patients with coronary heart disease (VTACH): a multicentre randomised controlled trial","volume":"375","author":"Kuck","year":"2010","journal-title":"Lancet"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0015","article-title":"2017 AHA\/ACC\/HRS guideline for management of patients with ventricular arrhythmias and the prevention of sudden cardiac death: executive summary","volume":"138","author":"Al-Khatib","year":"2018","journal-title":"Circulation"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0016","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCULATIONAHA.106.670067","article-title":"All patients with hemodynamically tolerated postinfarction ventricular tachycardia do not require an implantable cardioverter-defibrillator","volume":"116","author":"Almendral","year":"2007","journal-title":"Circulation"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0017","doi-asserted-by":"crossref","first-page":"414","DOI":"10.1053\/euhj.2001.2804","article-title":"Catheter ablation and antiarrhythmic drugs for haemodynamically tolerated post-infarction ventricular tachycardia; long-term outcome in relation to acute electrophysiological findings","volume":"23","author":"Della Bella","year":"2002","journal-title":"Eur Heart J"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0018","article-title":"Long-term follow-up after radiofrequency catheter ablation of ventricular tachycardia: a successful approach?","volume":"13","author":"Burg","year":"2002","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0019","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCEP.113.000261","article-title":"A Stepwise approach to the management of postinfarct ventricular tachycardia using catheter ablation as the first-line treatment","volume":"6","author":"Pauriah","year":"2013","journal-title":"Circ Arrhythmia Electrophysiol"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0020","doi-asserted-by":"crossref","DOI":"10.1093\/eurheartj\/ehu040","article-title":"Radio-frequency ablation as primary management of well-tolerated sustained monomorphic ventricular tachycardia in patients with structural heart disease and left ventricular ejection fraction over 30%","volume":"35","author":"Maury","year":"2014","journal-title":"Eur Heart J"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0021","doi-asserted-by":"crossref","first-page":"457","DOI":"10.1161\/01.CIR.65.3.457","article-title":"Clinical classification of cardiac deaths","volume":"65","author":"Hinkle","year":"1982","journal-title":"Circulation"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0022","article-title":"Management of ventricular tachycardia in the setting of a dedicated unit for the treatment of complex ventricular arrhythmias","volume":"127","author":"Della","year":"2013","journal-title":"Circulation"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0023","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2009.09.014","article-title":"Incidence and predictors of mortality following ablation of ventricular tachycardia in patients with an implantable cardioverter-defibrillator","volume":"7","author":"Sauer","year":"2010","journal-title":"Hear Rhythm."},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0024","doi-asserted-by":"crossref","DOI":"10.1161\/01.CIR.103.2.244","article-title":"Stable\u201d ventricular tachycardia is not a benign rhythm","volume":"103","author":"Raitt","year":"2001","journal-title":"Circulation"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0025","doi-asserted-by":"crossref","first-page":"153","DOI":"10.1161\/CIRCEP.108.769471","article-title":"Ventricular tachycardia ablation: evolution of patients and procedures over 8 years","volume":"1","author":"Sacher","year":"2008","journal-title":"Circ Arrhythm Electrophysiol"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0027","doi-asserted-by":"crossref","DOI":"10.1001\/jamacardio.2018.1049","article-title":"Sudden death in patients with coronary heart disease without severe systolic dysfunction","volume":"3","author":"Chatterjee","year":"2018","journal-title":"JAMA Cardiol"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0028","doi-asserted-by":"crossref","DOI":"10.1016\/j.jacc.2017.03.568","article-title":"Seattle heart failure and proportional risk models predict benefit from implantable cardioverter-defibrillators","volume":"69","author":"Bilchick","year":"2017","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0029","doi-asserted-by":"crossref","DOI":"10.1002\/ejhf.1755","article-title":"One-year mortality after implantable cardioverter-defibrillator placement within the veterans affairs health system","volume":"22","author":"Fudim","year":"2020","journal-title":"Eur J Heart Fail"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0030","doi-asserted-by":"crossref","DOI":"10.1056\/NEJMoa071098","article-title":"Prognostic importance of defibrillator shocks in patients with heart failure","volume":"359","author":"Poole","year":"2008","journal-title":"N Engl J Med"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0031","doi-asserted-by":"crossref","DOI":"10.1046\/j.1540-8167.2004.03344.x","article-title":"Long-term outcome of patients who received implantable cardioverter defibrillators for stable ventricular tachycardia","volume":"15","author":"Glikson","year":"2004","journal-title":"J Cardiovasc Electrophysiol"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0032","doi-asserted-by":"crossref","DOI":"10.1016\/j.jacc.2006.02.049","article-title":"The frequency and incremental cost of major complications among medicare beneficiaries receiving implantable cardioverter-defibrillators","volume":"47","author":"Reynolds","year":"2006","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0033","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2011.07.036","article-title":"Shocks burden and increased mortality in implantable cardioverter-defibrillator patients","volume":"8","author":"Larsen","year":"2011","journal-title":"Hear Rhythm."},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0034","doi-asserted-by":"crossref","DOI":"10.1016\/j.hrthm.2009.11.027","article-title":"Differences in effects of electrical therapy type for ventricular arrhythmias on mortality in implantable cardioverter-defibrillator patients","volume":"7","author":"Sweeney","year":"2010","journal-title":"Hear Rhythm."},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0035","doi-asserted-by":"crossref","DOI":"10.1161\/CIRCULATIONAHA.110.960633","article-title":"Long-Term outcome after ICD and CRT implantation and influence of remote device follow-up","volume":"122","author":"Saxon","year":"2010","journal-title":"Circulation"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0036","doi-asserted-by":"crossref","DOI":"10.1056\/NEJMoa1211107","article-title":"Reduction in inappropriate therapy and mortality through ICD programming","volume":"367","author":"Moss","year":"2012","journal-title":"N Engl J Med"},{"key":"10.1016\/j.cpcardiol.2022.101349_bib0037","doi-asserted-by":"crossref","DOI":"10.1016\/j.amjcard.2005.11.048","article-title":"Frequency and causes of implantable cardioverter-defibrillator therapies: is device therapy proarrhythmic?","volume":"97","author":"Germano","year":"2006","journal-title":"Am J Cardiol"}],"container-title":["Current Problems in Cardiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0146280622002468?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0146280622002468?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,27]],"date-time":"2025-09-27T01:59:28Z","timestamp":1758938368000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0146280622002468"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,12]]},"references-count":36,"journal-issue":{"issue":"12","published-print":{"date-parts":[[2022,12]]}},"alternative-id":["S0146280622002468"],"URL":"https:\/\/doi.org\/10.1016\/j.cpcardiol.2022.101349","relation":{},"ISSN":["0146-2806"],"issn-type":[{"value":"0146-2806","type":"print"}],"subject":[],"published":{"date-parts":[[2022,12]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Catheter Ablation of Well Tolerated Ventricular Tachycardia in Patients With Structural Heart Disease and Without Automatic Defibrillator Implantation: Long Term Follow-up","name":"articletitle","label":"Article Title"},{"value":"Current Problems in Cardiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.cpcardiol.2022.101349","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"name":"copyright","label":"Copyright"}],"article-number":"101349"}}