{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,14]],"date-time":"2026-06-14T20:09:14Z","timestamp":1781467754823,"version":"3.54.1"},"reference-count":49,"publisher":"Elsevier BV","issue":"4","license":[{"start":{"date-parts":[[2011,10,1]],"date-time":"2011-10-01T00:00:00Z","timestamp":1317427200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2011,10,1]],"date-time":"2011-10-01T00:00:00Z","timestamp":1317427200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","theclinics.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinics in Podiatric Medicine and Surgery"],"published-print":{"date-parts":[[2011,10]]},"DOI":"10.1016\/j.cpm.2011.06.003","type":"journal-article","created":{"date-parts":[[2011,9,24]],"date-time":"2011-09-24T00:26:30Z","timestamp":1316823990000},"page":"619-631","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":9,"title":["Locking Plate Technology and Its Use in Foot and Ankle Surgery"],"prefix":"10.1016","volume":"28","author":[{"given":"Dekarlos M.","family":"Dial","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Michael","family":"Ryan","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.cpm.2011.06.003_bib1","doi-asserted-by":"crossref","first-page":"975","DOI":"10.1007\/s11999-009-0991-7","article-title":"Minimally invasive locked plating of distal tibia fractures is safe and effective","volume":"468","author":"Ronga","year":"2010","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.cpm.2011.06.003_bib2","doi-asserted-by":"crossref","first-page":"1093","DOI":"10.1302\/0301-620X.84B8.0841093","article-title":"Evolution of the internal fixation of long bone fractures: the scientific basis of biological internal fixation. Choosing a new balance between stability and biology","volume":"84","author":"Perren","year":"2002","journal-title":"J\u00a0Bone Joint Surg Br"},{"key":"10.1016\/j.cpm.2011.06.003_bib3","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1097\/00003086-198807000-00018","article-title":"Early temporary porosis of bone induced by internal fixation implants: a reaction to necrosis, not to stress protection?","volume":"232","author":"Perren","year":"1988","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.cpm.2011.06.003_bib4","doi-asserted-by":"crossref","first-page":"406","DOI":"10.5435\/00124635-200607000-00003","article-title":"Surgical treatment of nonarticular distal tibia fractures","volume":"14","author":"Bedi","year":"2006","journal-title":"J\u00a0Am Acad Orthop Surg"},{"key":"10.1016\/j.cpm.2011.06.003_bib5","doi-asserted-by":"crossref","first-page":"205","DOI":"10.5435\/00124635-200407000-00001","article-title":"Perspectives on modern orthopaedics: innovations in locking plate technology","volume":"12","author":"Haidukewych","year":"2004","journal-title":"J\u00a0Am Acad Orthop Surg"},{"key":"10.1016\/j.cpm.2011.06.003_bib6","doi-asserted-by":"crossref","first-page":"183","DOI":"10.5435\/00124635-200603000-00009","article-title":"The use of locking plates in fracture care","volume":"14","author":"Cantu","year":"2006","journal-title":"J\u00a0Am Acad Orthop Surg"},{"key":"10.1016\/j.cpm.2011.06.003_bib7","doi-asserted-by":"crossref","first-page":"176","DOI":"10.1097\/01.blo.0000137554.91189.a9","article-title":"A\u00a0new locking plate for unstable fracture of the proximal humerus","volume":"430","author":"Fankhauser","year":"2005","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.cpm.2011.06.003_bib8","doi-asserted-by":"crossref","first-page":"50","DOI":"10.1097\/01.blo.0000131484.27501.4b","article-title":"Locking compression plates for osteoporotic nonunions of the diaphyseal humerus","volume":"425","author":"Ring","year":"2004","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.cpm.2011.06.003_bib9","doi-asserted-by":"crossref","first-page":"488","DOI":"10.1097\/00005131-200409000-00003","article-title":"Biomechanics of locked plates and screws","volume":"18","author":"Egol","year":"2004","journal-title":"J\u00a0Orthop Trauma"},{"key":"10.1016\/j.cpm.2011.06.003_bib10","doi-asserted-by":"crossref","first-page":"831","DOI":"10.1007\/s11999-008-0459-1","article-title":"Fractures of the distal tibia treated with polyaxial locking plating","volume":"467","author":"Gao","year":"2009","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.cpm.2011.06.003_bib11","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1097\/00005131-200409000-00002","article-title":"Locked internal fixator. Sensitivity of screw\/plate stability to the correct insertion angle of the screw","volume":"18","author":"Kaab","year":"2004","journal-title":"J\u00a0Orthop Trauma"},{"key":"10.1016\/j.cpm.2011.06.003_bib12","doi-asserted-by":"crossref","first-page":"625","DOI":"10.2106\/00004623-197759050-00008","article-title":"Compression bone-plating: historical considerations","volume":"59","author":"Bagby","year":"1977","journal-title":"J\u00a0Bone Joint Surg Am"},{"issue":"Suppl 3","key":"10.1016\/j.cpm.2011.06.003_bib13","doi-asserted-by":"crossref","first-page":"C21","DOI":"10.1016\/S0020-1383(00)80028-5","article-title":"Force transfer between the plate and the bone: relative importance of the bending stiffness of the screws friction between plate and bone","volume":"31","author":"Cordey","year":"2000","journal-title":"Injury"},{"key":"10.1016\/j.cpm.2011.06.003_bib14","first-page":"189","article-title":"The evolution of locked plates","volume":"88","author":"Kubiak","year":"2006","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.cpm.2011.06.003_bib15","doi-asserted-by":"crossref","first-page":"67","DOI":"10.1097\/00003086-199111000-00010","article-title":"Zespol: an original method of stable osteosynthesis","volume":"272","author":"Ramotowski","year":"1991","journal-title":"Clin Orthop"},{"issue":"S1","key":"10.1016\/j.cpm.2011.06.003_bib16","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1016\/0020-1383(95)96891-7","article-title":"Point contact fixator: part I. Scientific background, design and application","volume":"22","author":"Perren","year":"1995","journal-title":"Injury"},{"key":"10.1016\/j.cpm.2011.06.003_bib17","doi-asserted-by":"crossref","first-page":"392","DOI":"10.1007\/s100390050069","article-title":"LISS osteosynthesis for distal fractures of the femur","volume":"1","author":"Schandelmaier","year":"1999","journal-title":"Trauma und Berufskrankheit"},{"key":"10.1016\/j.cpm.2011.06.003_bib18","first-page":"1545","article-title":"Monoaxial versus polyaxial screw insertion in angular stable plate fixation of proximal humerus fractures: radiographic analysis of a prospective randomized study","volume":"69","author":"Ockert","year":"2010","journal-title":"J\u00a0Trauma"},{"key":"10.1016\/j.cpm.2011.06.003_bib19","doi-asserted-by":"crossref","first-page":"S-B6","DOI":"10.1016\/j.injury.2003.09.020","article-title":"Development of the locking compression plate","volume":"34","author":"Frigg","year":"2003","journal-title":"Injury"},{"key":"10.1016\/j.cpm.2011.06.003_bib20","doi-asserted-by":"crossref","first-page":"108","DOI":"10.1097\/00003086-199307000-00013","article-title":"Open reduction and internal fixation of tibial plafond fractures","volume":"292","author":"Teeney","year":"1993","journal-title":"Clin Orthop Relat Res"},{"issue":"Suppl 3","key":"10.1016\/j.cpm.2011.06.003_bib21","doi-asserted-by":"crossref","first-page":"SC32","DOI":"10.1016\/S0020-1383(01)00182-6","article-title":"Distal femoral fracture fixation utilizing the Less Invasive Stabilization System (L.I.S.S.): the technique and early results","volume":"32","author":"Kregor","year":"2001","journal-title":"Injury"},{"key":"10.1016\/j.cpm.2011.06.003_bib22","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1007\/s00264-002-0393-x","article-title":"Osteosynthesis of distal radius fractures with a volar locking screw plate system","volume":"27","author":"Drobertz","year":"2003","journal-title":"Int Orthop"},{"issue":"Suppl 3","key":"10.1016\/j.cpm.2011.06.003_bib23","doi-asserted-by":"crossref","first-page":"SC48","DOI":"10.1016\/S0020-1383(01)00183-8","article-title":"Minimally invasive fracture stabilization of distal femoral fractures with the LISS: a prospective multicenter study: results of a clinical study with special emphasis on difficult cases","volume":"32","author":"Schutz","year":"2001","journal-title":"Injury"},{"key":"10.1016\/j.cpm.2011.06.003_bib24","doi-asserted-by":"crossref","first-page":"334","DOI":"10.1097\/00007632-199902150-00005","article-title":"The effect of locking fixation screws on the stability of anterior cervical plating","volume":"24","author":"Spivak","year":"1999","journal-title":"Spine"},{"key":"10.1016\/j.cpm.2011.06.003_bib25","doi-asserted-by":"crossref","first-page":"205","DOI":"10.5435\/00124635-200407000-00001","article-title":"Innovations in locking plate technology","volume":"12","author":"Haidukewych","year":"2004","journal-title":"J\u00a0Am Acad Orthop Surg"},{"issue":"Suppl 2","key":"10.1016\/j.cpm.2011.06.003_bib26","doi-asserted-by":"crossref","first-page":"B20","DOI":"10.1016\/j.injury.2003.09.022","article-title":"The LCP\u2014concept in the operative treatment of distal humerus fractures-biological, biomechanical and surgical aspects","volume":"34","author":"Korner","year":"2003","journal-title":"Injury"},{"key":"10.1016\/j.cpm.2011.06.003_bib27","doi-asserted-by":"crossref","first-page":"196","DOI":"10.1177\/107110070602700308","article-title":"A\u00a0biomechanical comparison of locking plates and nonlocking plates for the fixation of calcaneal fractures","volume":"27","author":"Redfern","year":"2006","journal-title":"Foot Ankle Int"},{"key":"10.1016\/j.cpm.2011.06.003_bib28","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1177\/107110070502600407","article-title":"A\u00a0comparison of plates with and without locking screws in a calcaneal fracture model","volume":"26","author":"Richter","year":"2005","journal-title":"Foot Ankle Int"},{"key":"10.1016\/j.cpm.2011.06.003_bib29","doi-asserted-by":"crossref","first-page":"709","DOI":"10.1016\/j.orthres.2003.11.007","article-title":"The influence of cyclic compression and distraction on the healing of experimental tibial fractures","volume":"22","author":"Hente","year":"2004","journal-title":"J\u00a0Orthop Res"},{"issue":"Suppl","key":"10.1016\/j.cpm.2011.06.003_bib30","doi-asserted-by":"crossref","first-page":"S132","DOI":"10.1097\/00003086-199810001-00015","article-title":"Effects of mechanical factors on the fracture healing process","volume":"355","author":"Claes","year":"1998","journal-title":"Clin Orthop Relat Res"},{"key":"10.1016\/j.cpm.2011.06.003_bib31","doi-asserted-by":"crossref","first-page":"783","DOI":"10.2106\/00004623-197153040-00020","article-title":"Primary bone healing. An experimental study in the rabbit","volume":"53","author":"Rahn","year":"1971","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.cpm.2011.06.003_bib32","doi-asserted-by":"crossref","first-page":"1652","DOI":"10.2106\/JBJS.I.01111","article-title":"Far cortical locking plates can improve healing of fractures stabilized with locking plates","volume":"92","author":"Bottlang","year":"2010","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.cpm.2011.06.003_bib33","doi-asserted-by":"crossref","first-page":"156","DOI":"10.1097\/BOT.0b013e3181be6720","article-title":"Locked plating of distal femur fractures leads to inconsistent and asymmetric callus formation","volume":"24","author":"Lujan","year":"2010","journal-title":"J\u00a0Orthop Trauma"},{"key":"10.1016\/j.cpm.2011.06.003_bib34","doi-asserted-by":"crossref","first-page":"509","DOI":"10.1097\/00005131-200409000-00006","article-title":"Treatment of distal femur fractures using the less invasive stabilization system: surgical experience and early clinical results in 103 fractures","volume":"18","author":"Kregor","year":"2004","journal-title":"J\u00a0Orthop Trauma"},{"key":"10.1016\/j.cpm.2011.06.003_bib35","doi-asserted-by":"crossref","first-page":"55","DOI":"10.1080\/00016470410001708110","article-title":"Minimal invasive treatment of the LISS (Less Invasive Stabilization System): a prospective study of 30 fractures with a follow up of 20 months","volume":"75","author":"Fankhauser","year":"2004","journal-title":"Acta Orthop Scand"},{"key":"10.1016\/j.cpm.2011.06.003_bib36","doi-asserted-by":"crossref","first-page":"1985","DOI":"10.2106\/JBJS.H.01038","article-title":"Far cortical locking can reduce stiffness of locked plating constructs while retaining construct strength","volume":"91","author":"Bottlang","year":"2009","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.cpm.2011.06.003_bib37","series-title":"Planning and reduction technique in fracture surgery","author":"Mast","year":"1989"},{"issue":"Suppl 2","key":"10.1016\/j.cpm.2011.06.003_bib38","doi-asserted-by":"crossref","first-page":"B11","DOI":"10.1016\/j.injury.2003.09.021","article-title":"Biomechanical testing of the LCP\u2014how can stability in locked internal fixators be controlled?","volume":"34","author":"Stoffel","year":"2003","journal-title":"Injury"},{"key":"10.1016\/j.cpm.2011.06.003_bib39","doi-asserted-by":"crossref","first-page":"181","DOI":"10.1016\/j.injury.2007.08.026","article-title":"Fixation of long bone segmental defects: a biomechanical study","volume":"39","author":"Talbot","year":"2008","journal-title":"Injury"},{"key":"10.1016\/j.cpm.2011.06.003_bib40","doi-asserted-by":"crossref","first-page":"358","DOI":"10.1016\/j.injury.2006.08.058","article-title":"Biomechanical testing of the locking compression plate: when does the distance between bone and implant significantly reduce construct stability?","volume":"38","author":"Ahmad","year":"2007","journal-title":"Injury"},{"issue":"Suppl 2","key":"10.1016\/j.cpm.2011.06.003_bib41","doi-asserted-by":"crossref","first-page":"B63","DOI":"10.1016\/j.injury.2003.09.026","article-title":"Guidelines for the clinical application of the LCP","volume":"34","author":"Gautier","year":"2003","journal-title":"Injury"},{"key":"10.1016\/j.cpm.2011.06.003_bib42","doi-asserted-by":"crossref","first-page":"361","DOI":"10.3113\/FAI.2007.0361","article-title":"Bunion surgery using locking-plate fixation of proximal chevron osteotomies","volume":"28","author":"Gallentine","year":"2007","journal-title":"Foot Ankle Int"},{"key":"10.1016\/j.cpm.2011.06.003_bib43","doi-asserted-by":"crossref","first-page":"219","DOI":"10.3113\/FAI.2008.0219","article-title":"Blade plate compared with locking plate for tibiotalocalcaneal arthrodesis: a cadaver study","volume":"29","author":"Chodos","year":"2008","journal-title":"Foot Ankle Int"},{"key":"10.1016\/j.cpm.2011.06.003_bib44","doi-asserted-by":"crossref","first-page":"581","DOI":"10.3113\/FAI.2008.0581","article-title":"Rigidity comparison of locking plate intramedullary fixation for tibiotalocalcaneal arthrodesis","volume":"29","author":"O\u2019Neil","year":"2008","journal-title":"Foot Ankle Int"},{"key":"10.1016\/j.cpm.2011.06.003_bib45","doi-asserted-by":"crossref","first-page":"2425","DOI":"10.2106\/00004623-200312000-00022","article-title":"Intramedullary fixation compared with blade-plate- and screw fixation for tibiotalocalcaneal arthrodesis: a biomechanical investigation","volume":"85","author":"Chiodo","year":"2003","journal-title":"J\u00a0Bone Joint Surg Am"},{"key":"10.1016\/j.cpm.2011.06.003_bib46","doi-asserted-by":"crossref","first-page":"320","DOI":"10.1177\/1938640010374121","article-title":"Early weight bearing of calcaneal fractures fixated with locked plates: a radiographic review","volume":"3","author":"Hyer","year":"2010","journal-title":"Foot Ankle Spec"},{"key":"10.1016\/j.cpm.2011.06.003_bib47","doi-asserted-by":"crossref","first-page":"170","DOI":"10.1053\/j.jfas.2008.12.009","article-title":"Lapidus bunionectomy: early evaluation of crossed lag screws versus locking plate with plantar lag screw","volume":"48","author":"Saxena","year":"2009","journal-title":"J\u00a0Foot Ankle Surg"},{"key":"10.1016\/j.cpm.2011.06.003_bib48","doi-asserted-by":"crossref","first-page":"984","DOI":"10.1177\/107110070502601114","article-title":"Screw fixation compared to H-locking fixation for first metatarsal cuneiform joint arthrodesis: a biomechanical study","volume":"26","author":"Cohen","year":"2005","journal-title":"Foot Ankle Int"},{"key":"10.1016\/j.cpm.2011.06.003_bib49","doi-asserted-by":"crossref","first-page":"158","DOI":"10.3113\/FAI.2010.0157","article-title":"Stability of medial locking plate and a compression screw versus two crossed screws for Lapidus arthrodesis","volume":"31","author":"Klos","year":"2010","journal-title":"Foot Ankle Int"}],"container-title":["Clinics in Podiatric Medicine and Surgery"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0891842211000474?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0891842211000474?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,10,11]],"date-time":"2025-10-11T18:54:22Z","timestamp":1760208862000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0891842211000474"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2011,10]]},"references-count":49,"journal-issue":{"issue":"4","published-print":{"date-parts":[[2011,10]]}},"alternative-id":["S0891842211000474"],"URL":"https:\/\/doi.org\/10.1016\/j.cpm.2011.06.003","relation":{},"ISSN":["0891-8422"],"issn-type":[{"value":"0891-8422","type":"print"}],"subject":[],"published":{"date-parts":[[2011,10]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Locking Plate Technology and Its Use in Foot and Ankle Surgery","name":"articletitle","label":"Article Title"},{"value":"Clinics in Podiatric Medicine and Surgery","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.cpm.2011.06.003","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2011 Published by Elsevier Inc.","name":"copyright","label":"Copyright"}]}}