{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,4]],"date-time":"2026-06-04T06:56:38Z","timestamp":1780556198003,"version":"3.54.1"},"reference-count":82,"publisher":"Elsevier BV","issue":"1","license":[{"start":{"date-parts":[[2005,1,1]],"date-time":"2005-01-01T00:00:00Z","timestamp":1104537600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2005,1,1]],"date-time":"2005-01-01T00:00:00Z","timestamp":1104537600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","clinicalradiologyonline.net","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Radiology"],"published-print":{"date-parts":[[2005,1]]},"DOI":"10.1016\/j.crad.2004.03.025","type":"journal-article","created":{"date-parts":[[2005,1,11]],"date-time":"2005-01-11T07:29:34Z","timestamp":1105428574000},"page":"8-21","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":23,"title":["Electrocardiographic assistance in multidetector CT of thoracic disorders"],"prefix":"10.1016","volume":"60","author":[{"given":"K.","family":"Marten","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.","family":"Funke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"E.J.","family":"Rummeny","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"C.","family":"Engelke","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.crad.2004.03.025_bib1","series-title":"Spiral and multislice computed tomography of the body","first-page":"759","article-title":"Heart","author":"Prokop","year":"2003"},{"key":"10.1016\/j.crad.2004.03.025_bib2","doi-asserted-by":"crossref","first-page":"123","DOI":"10.1007\/s001170050020","article-title":"Optimizing temporal resolution in CT with retrospective ECG gating","volume":"40","author":"Boese","year":"2000","journal-title":"Radiologie"},{"key":"10.1016\/j.crad.2004.03.025_bib3","doi-asserted-by":"crossref","first-page":"271","DOI":"10.1148\/radiol.2221010481","article-title":"Thoracic aorta: motion artifact reduction with retrospective and prospective electrocardiography-assisted multi-detector row CT","volume":"222","author":"Roos","year":"2002","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib4","first-page":"106","article-title":"Retrospectively ECG-gated spiral CT of the heart and lung","volume":"9","author":"Bahner","year":"1999","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib5","doi-asserted-by":"crossref","first-page":"97","DOI":"10.1016\/S0720-048X(00)00272-2","article-title":"Current development of cardiac imaging with multidetector-row CT","volume":"36","author":"Becker","year":"2000","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib6","doi-asserted-by":"crossref","first-page":"111","DOI":"10.1007\/s001170050018","article-title":"Cardiac imaging with rapid, retrospective ECG synchronized multilevel spiral CT","volume":"40","author":"Ohnesorge","year":"2000","journal-title":"Radiologie"},{"key":"10.1016\/j.crad.2004.03.025_bib7","doi-asserted-by":"crossref","first-page":"164","DOI":"10.1055\/s-2008-1056544","article-title":"ECG-controlled cardio-computer tomography","volume":"132","author":"Lackner","year":"1980","journal-title":"Fortschr R\u00f6ntgenstr"},{"key":"10.1016\/j.crad.2004.03.025_bib8","doi-asserted-by":"crossref","first-page":"733","DOI":"10.1007\/s00117-002-0787-1","article-title":"CT angiography of the coronary arteries with a 16-row spiral tomograph. Effect of spatial resolution on image quality","volume":"42","author":"Jakobs","year":"2002","journal-title":"Radiologie"},{"key":"10.1016\/j.crad.2004.03.025_bib9","doi-asserted-by":"crossref","first-page":"118","DOI":"10.1007\/s001170050019","article-title":"Initial experiences with multi-slice detector spiral CT in diagnosis of arteriosclerosis of coronary vessels","volume":"40","author":"Becker","year":"2000","journal-title":"Radiologie"},{"key":"10.1016\/j.crad.2004.03.025_bib10","first-page":"239","article-title":"Variation of heart rate and electrocardiograph trigger interval during ultrafast computed tomography","volume":"10","author":"Mao","year":"1996","journal-title":"Am J Card Imaging"},{"key":"10.1016\/j.crad.2004.03.025_bib11","doi-asserted-by":"crossref","first-page":"571","DOI":"10.1148\/radiology.208.3.9722830","article-title":"Coronary arterial calcium screening: ready for prime time?","volume":"208","author":"Flamm","year":"1998","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib12","doi-asserted-by":"crossref","first-page":"1006","DOI":"10.1007\/s001170050455","article-title":"Methods of quantification of coronary artery calcifications with electron-beam and conventional computed tomography","volume":"38","author":"Becker","year":"1998","journal-title":"Radiologie"},{"key":"10.1016\/j.crad.2004.03.025_bib13","doi-asserted-by":"crossref","first-page":"1881","DOI":"10.1118\/1.1286552","article-title":"ECG-correlated image reconstruction from subsecond multi-slice spiral CT scans of the heart","volume":"27","author":"Kachelriess","year":"2000","journal-title":"Med Phys"},{"key":"10.1016\/j.crad.2004.03.025_bib14","doi-asserted-by":"crossref","first-page":"564","DOI":"10.1148\/radiology.217.2.r00nv30564","article-title":"Cardiac imaging by means of electrocardiographically gated multisection spiral CT: initial experience","volume":"217","author":"Ohnesorge","year":"2000","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib15","doi-asserted-by":"crossref","first-page":"907","DOI":"10.1097\/00004728-200111000-00014","article-title":"Heart-rate adaptive optimization of spatial and temporal resolution for ECG-gated multislice spiral CT of the heart","volume":"25","author":"Flohr","year":"2001","journal-title":"J Comput Assist Tomogr"},{"issue":"1022","key":"10.1016\/j.crad.2004.03.025_bib16","first-page":"1027","article-title":"New technical developments in multislice, CT, part 2: sub-millimeter slice scanning and increased gantry rotation speed for cardiac imaging","volume":"174","author":"Flohr","year":"2002","journal-title":"Fortschr R\u00f6ntgenstr"},{"issue":"721","key":"10.1016\/j.crad.2004.03.025_bib17","first-page":"724","article-title":"Visualization of coronary arteries in CT as assessed by a new 16 slice technology and reduced gantry rotation time: first experience","volume":"174","author":"Heuschmid","year":"2002","journal-title":"Fortsch R\u00f6ntgenstr"},{"key":"10.1016\/j.crad.2004.03.025_bib18","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1148\/radiol.2261011365","article-title":"Radiation exposure during cardiac CT: effective doses at multi-detector row CT and electron-beam CT","volume":"226","author":"Hunold","year":"2003","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib19","doi-asserted-by":"crossref","first-page":"1923","DOI":"10.1007\/s00330-003-1895-7","article-title":"Ultra-low-dose coronary artery calcium screening using multislice CT with retrospective ECG gating","volume":"13","author":"Jakobs","year":"2003","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib20","doi-asserted-by":"crossref","first-page":"1081","DOI":"10.1007\/s00330-001-1278-x","article-title":"Multislice helical CT of the heart with retrospective ECG gating: reduction of radiation exposure by ECG-controlled tube current modulation","volume":"12","author":"Jakobs","year":"2002","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib21","first-page":"487","article-title":"Dose evaluation and dose reduction strategies for ECG-gated multislice spiral CT of the heart","volume":"217","author":"Ohnesorge","year":"2000","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib22","doi-asserted-by":"crossref","first-page":"1175","DOI":"10.1161\/01.CIR.94.5.1175","article-title":"Coronary artery calcification: pathophysiology, epidemiology, imaging methods, and clinical implications: a statement for health professionals from the American Heart Association Writing Group","volume":"94","author":"Wexler","year":"1996","journal-title":"Circulation"},{"key":"10.1016\/j.crad.2004.03.025_bib23","doi-asserted-by":"crossref","first-page":"827","DOI":"10.1016\/0735-1097(90)90282-T","article-title":"Quantification of coronary artery calcium using ultrafast computed tomography","volume":"15","author":"Agatston","year":"1990","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.crad.2004.03.025_bib24","doi-asserted-by":"crossref","first-page":"807","DOI":"10.1148\/radiology.208.3.9722864","article-title":"Coronary artery disease: improved reproducibility of calcium scoring with an electron-beam CT volumetric method","volume":"208","author":"Callister","year":"1998","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib25","doi-asserted-by":"crossref","first-page":"1972","DOI":"10.1056\/NEJM199812313392703","article-title":"Effect of HMG-CoA reductase inhibitors on coronary artery disease as assessed by electron-beam computed tomography","volume":"339","author":"Callister","year":"1998","journal-title":"N Engl J Med"},{"key":"10.1016\/j.crad.2004.03.025_bib26","doi-asserted-by":"crossref","first-page":"224","DOI":"10.1148\/radiology.218.1.r01ja34224","article-title":"Coronary artery calcification measured at electron-beam CT: agreement in dual scan runs and change over time","volume":"218","author":"Bielak","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib27","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1161\/01.CIR.102.1.126","article-title":"ACC\/AHA expert consensus document on EBCT for the diagnosis and prognosis of coronary artery disease","volume":"102","author":"O'Rouke","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.crad.2004.03.025_bib28","doi-asserted-by":"crossref","first-page":"550","DOI":"10.1016\/S0002-8703(96)90237-9","article-title":"Detection of coronary calcification with electron-beam computed tomography: evaluation of interexamination reproducibility and comparison of three image-acquisition protocols","volume":"132","author":"Wang","year":"1996","journal-title":"Am Heart J"},{"key":"10.1016\/j.crad.2004.03.025_bib29","doi-asserted-by":"crossref","first-page":"17","DOI":"10.1007\/s003300200003","article-title":"Multidetector-row CT cardiac imaging with 4 and 16 slices for coronary CTA and imaging of atherosclerotic plaques","volume":"12","author":"Kopp","year":"2002","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib30","doi-asserted-by":"crossref","first-page":"496","DOI":"10.1097\/00004424-200209000-00004","article-title":"Variation of the coronary calcium score depending on image reconstruction interval and scoring algorithm","volume":"37","author":"Mahnken","year":"2002","journal-title":"Invest Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib31","doi-asserted-by":"crossref","first-page":"838","DOI":"10.1148\/radiol.2242011332","article-title":"EKG-triggered CT data acquisition to reduce variability in coronary arterial calcium score","volume":"224","author":"Lu","year":"2002","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib32","doi-asserted-by":"crossref","first-page":"1295","DOI":"10.2214\/ajr.176.5.1761295","article-title":"Coronary artery calcium measurement: agreement of multirow detector and electron beam CT","volume":"176","author":"Becker","year":"2001","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2004.03.025_bib33","first-page":"402","article-title":"Comparison of EBCT and ECG-gated multislice spiral CT: a study of 3D Ca-scoring with phantom and patient data","volume":"213","author":"Ohnesorge","year":"1999","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib34","doi-asserted-by":"crossref","first-page":"1532","DOI":"10.1007\/s00330-002-1394-2","article-title":"Reproducibility of coronary calcium quantification in repeat examinations with retrospectively ECG-gated multisection spiral CT","volume":"12","author":"Ohnesorge","year":"2002","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib35","doi-asserted-by":"crossref","first-page":"1429","DOI":"10.2214\/ajr.177.6.1771429","article-title":"Quantification of coronary artery calcium using multidetector CT and a retrospective ECG-gating reconstruction algorithm","volume":"177","author":"Horiguchi","year":"2001","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2004.03.025_bib36","doi-asserted-by":"crossref","first-page":"2026","DOI":"10.1161\/01.CIR.0000034392.34211.FC","article-title":"Computed tomography and magnetic resonance imaging for noninvasive coronary angiography and plaque imaging: current and potential future concepts","volume":"106","author":"Fayad","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.crad.2004.03.025_bib37","first-page":"57","article-title":"Noninvasive coronary angiography with multidetector row CT technology. Categorial course in diagnostic radiology: thoracic imaging-chest and cardiac","volume":"2001","author":"Becker","year":"2001","journal-title":"RSNA Syllabus"},{"key":"10.1016\/j.crad.2004.03.025_bib38","doi-asserted-by":"crossref","first-page":"2823","DOI":"10.1161\/01.CIR.102.23.2823","article-title":"Noninvasive coronary angiography by retrospectively ECG-gated multislice spiral CT","volume":"102","author":"Achenbach","year":"2000","journal-title":"Circulation"},{"key":"10.1016\/j.crad.2004.03.025_bib39","doi-asserted-by":"crossref","first-page":"683","DOI":"10.1148\/radiol.2213010174","article-title":"Coronary arteries: retrospectively ECG-gated multi-detector row CT angiography with selective optimization of the image reconstruction window","volume":"221","author":"Kopp","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib40","doi-asserted-by":"crossref","first-page":"750","DOI":"10.1097\/00004728-200209000-00015","article-title":"Detection of coronary artery stenoses with multislice helical CT angiography","volume":"26","author":"Becker","year":"2002","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.crad.2004.03.025_bib41","doi-asserted-by":"crossref","first-page":"2535","DOI":"10.1161\/01.CIR.103.21.2535","article-title":"Detection of coronary artery stenoses by contrast-enhanced, retrospectively electrocardiographically-gated, multislice spiral computed tomography","volume":"103","author":"Achenbach","year":"2001","journal-title":"Circulation"},{"key":"10.1016\/j.crad.2004.03.025_bib42","doi-asserted-by":"crossref","first-page":"913","DOI":"10.1016\/S0002-9149(02)02238-5","article-title":"Usefulness of multislice computed tomography for detecting obstructive coronary artery disease","volume":"89","author":"Nieman","year":"2002","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.crad.2004.03.025_bib43","doi-asserted-by":"crossref","first-page":"470","DOI":"10.1136\/heart.88.5.470","article-title":"Non-invasive coronary angiography with multislice spiral computed tomography: impact of heart rate","volume":"88","author":"Nieman","year":"2002","journal-title":"Heart"},{"key":"10.1016\/j.crad.2004.03.025_bib44","doi-asserted-by":"crossref","first-page":"2051","DOI":"10.1161\/01.CIR.0000037222.58317.3D","article-title":"Reliable noninvasive coronary angiography with fast submillimeter multislice spiral computed tomography","volume":"106","author":"Nieman","year":"2002","journal-title":"Circulation"},{"key":"10.1016\/j.crad.2004.03.025_bib45","first-page":"26","article-title":"Multislice CT of the coronary arteries: comparison with coronary angiography","volume":"173","author":"Fischbach","year":"2001","journal-title":"Fortschr Roentgenstr"},{"key":"10.1016\/j.crad.2004.03.025_bib46","first-page":"412","article-title":"Value and limits of multislice-cardiac-CT: a prospective study in over 500 patients","volume":"221","author":"Herzog","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib47","first-page":"200","article-title":"Comparison of the detectability of coronary arterial stenotic lesions by MR angiography and multidetector CT","volume":"221","author":"Nitatori","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib48","doi-asserted-by":"crossref","first-page":"378","DOI":"10.1016\/S0009-9260(03)00051-5","article-title":"Multislice computed tomographic coronary angiography: experience in a UK centre","volume":"58","author":"Morgan-Hughes","year":"2003","journal-title":"Clin Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib49","doi-asserted-by":"crossref","first-page":"508","DOI":"10.1016\/S0002-9149(98)00372-5","article-title":"Angiographic correlates of spotty coronary artery calcium detected by electron-beam computed tomography in patients with normal or near-normal coronary angiograms","volume":"82","author":"Schmermund","year":"1998","journal-title":"Am J Cardiol"},{"key":"10.1016\/j.crad.2004.03.025_bib50","doi-asserted-by":"crossref","first-page":"55","DOI":"10.4065\/77.1.55","article-title":"Current results and new developments of coronary angiography with use of contrast-enhanced computed tomography of the heart","volume":"77","author":"Gerber","year":"2002","journal-title":"Mayo Clin Proc"},{"key":"10.1016\/j.crad.2004.03.025_bib51","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1007\/s001170050021","article-title":"Proximal anastomoses of aortocoronary bypasses. Evaluation with ECG-triggered single-slice computerized tomography","volume":"40","author":"von Smekal","year":"2000","journal-title":"Radiologie"},{"key":"10.1016\/j.crad.2004.03.025_bib52","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1016\/S0720-048X(00)00230-8","article-title":"Morphology and patency of Gore-Tex wrapped internal mammary artery bypass-evaluation with helical CT","volume":"37","author":"Wohlgemuth","year":"2001","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib53","doi-asserted-by":"crossref","first-page":"120","DOI":"10.1148\/radiol.2251011703","article-title":"Electrocardiographically gated multi-detector row CT for assessment of valvular morphology and calcification in aortic stenosis","volume":"225","author":"Willmann","year":"2002","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib54","doi-asserted-by":"crossref","first-page":"209","DOI":"10.1097\/00019501-200206000-00002","article-title":"Aortic valve calcium on spiral computed tomography (dual slice mode) is associated with advanced coronary calcium in hypertensive patients","volume":"13","author":"Adler","year":"2002","journal-title":"Coron Artery Dis"},{"key":"10.1016\/j.crad.2004.03.025_bib55","doi-asserted-by":"crossref","first-page":"2662","DOI":"10.1007\/s00330-002-1454-7","article-title":"ECG-gated multidetector row CT for assessment of mitral valve disease: initial experience","volume":"12","author":"Willmann","year":"2002","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib56","doi-asserted-by":"crossref","first-page":"1545","DOI":"10.2214\/ajr.179.6.1791545","article-title":"Using ECG-gated multidetector CT to evaluate global left ventricular myocardial function in patients with coronary artery disease","volume":"179","author":"Juergens","year":"2002","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2004.03.025_bib57","first-page":"452","article-title":"Validation of left ventricular volume and ejection fraction measurement with multi-slice computed tomography: comparison to cine magnetic resonance imaging","volume":"221","author":"Halliburton","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib58","doi-asserted-by":"crossref","first-page":"1566","DOI":"10.1055\/s-2002-35946","article-title":"Multi-slice CT (MDCT) in cardiac function imaging: threshold-value supported 3D volume reconstructions to determine the left ventricular ejection fraction in comparison to MRI","volume":"174","author":"Ehrhard","year":"2002","journal-title":"Fortschr R\u00f6ntgenstr"},{"key":"10.1016\/j.crad.2004.03.025_bib59","first-page":"413","article-title":"Evaluation of wall motion using multi-detector-row CT: new application of post-processing interactive multi-planar animation of the heart","volume":"221","author":"Mochizuki","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib60","first-page":"196","article-title":"Early myocardial perfusion defect and late enhancement on enhancement CT predict clinical outcome in patients with acute myocardial infarction after reperfusion therapy","volume":"221","author":"Koyama","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib61","first-page":"294","article-title":"Assessment of regional myocardial perfusion using multirow-detector computed tomography (MDCT)","volume":"12","author":"Wintersperger","year":"2002","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib62","doi-asserted-by":"crossref","first-page":"31","DOI":"10.2214\/ajr.163.1.8010241","article-title":"Volumetric high-resolution CT in the diagnosis of interstitial lung disease and bronchiectasis: diagnostic accuracy and radiation dose","volume":"163","author":"Engeler","year":"1994","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2004.03.025_bib63","doi-asserted-by":"crossref","first-page":"1043","DOI":"10.1016\/S0033-8389(22)02103-0","article-title":"High resolution computed tomography. Technical aspects","volume":"29","author":"Mayo","year":"1991","journal-title":"Radiol Clin North Am"},{"key":"10.1016\/j.crad.2004.03.025_bib64","doi-asserted-by":"crossref","first-page":"395","DOI":"10.1016\/0887-2171(95)90028-4","article-title":"Bronchiectasis: CT\/clinical correlations","volume":"16","author":"McGuinness","year":"1995","journal-title":"Semin Ultrasound CT MR"},{"key":"10.1016\/j.crad.2004.03.025_bib65","doi-asserted-by":"crossref","first-page":"1117","DOI":"10.2214\/ajr.151.6.1117","article-title":"Motion artifacts on CT simulate bronchiectasis","volume":"151","author":"Tarver","year":"1988","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2004.03.025_bib66","first-page":"126","article-title":"Maximum and minimum intensity projection of spiral CT data for simultaneous 3D imaging of the pulmonary vasculature and airways","volume":"185","author":"Napel","year":"1992","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib67","doi-asserted-by":"crossref","first-page":"739","DOI":"10.1148\/radiographics.22.4.g02jl01739","article-title":"High resolution CT and CT angiography of peripheral pulmonary vascular disorders","volume":"22","author":"Engelke","year":"2002","journal-title":"RadioGraphics"},{"key":"10.1016\/j.crad.2004.03.025_bib68","doi-asserted-by":"crossref","first-page":"649","DOI":"10.1148\/radiology.212.3.r99se08649","article-title":"Electrocardiographically gated thin-section CT of the lung","volume":"212","author":"Sch\u00f6pf","year":"1999","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib69","doi-asserted-by":"crossref","first-page":"1681","DOI":"10.1007\/s003300000810","article-title":"Thin-section CT of the lung: influence of 0.5-s gantry rotation and ECG triggering on image quality","volume":"11","author":"Montaudon","year":"2001","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib70","doi-asserted-by":"crossref","first-page":"447","DOI":"10.1148\/radiology.217.2.r00nv01447","article-title":"Pulmonary embolism detection: prospective evaluation of dual-section helical CT versus selective pulmonary arteriography in 157 patients","volume":"217","author":"Qanadli","year":"2000","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib71","doi-asserted-by":"crossref","first-page":"1297","DOI":"10.1007\/s003300000460","article-title":"Thoracic helical CT: influence of subsecond scan time and thin collimation on evaluation of peripheral pulmonary arteries","volume":"10","author":"Remy-Jardin","year":"2000","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib72","doi-asserted-by":"crossref","first-page":"248","DOI":"10.1007\/s001170050984","article-title":"Diagnosis of lung embolism with multislice spiral CT","volume":"41","author":"Schoepf","year":"2001","journal-title":"Radiologie"},{"key":"10.1016\/j.crad.2004.03.025_bib73","doi-asserted-by":"crossref","first-page":"483","DOI":"10.1148\/radiol.2222001802","article-title":"Subsegmental pulmonary emboli: improved detection with thincollimation multi-detector row spiral CT","volume":"222","author":"Schoepf","year":"2002","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib74","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1148\/radiology.219.3.r01jn32629","article-title":"Peripheral pulmonary arteries: how far in the lung does multi-detector row spiral CT allow analysis?","volume":"219","author":"Ghaye","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib75","first-page":"75","article-title":"Spiral CT for acute pulmonary embolism","volume":"2001","author":"Mayo","year":"2001","journal-title":"RSNA Syllabus"},{"key":"10.1016\/j.crad.2004.03.025_bib76","doi-asserted-by":"crossref","first-page":"862","DOI":"10.1016\/S0009-9260(03)00348-9","article-title":"ECG-gated multislice spiral CT for diagnosis of acute pulmonary embolism","volume":"58","author":"Marten","year":"2003","journal-title":"Clin Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib77","doi-asserted-by":"crossref","first-page":"1","DOI":"10.1097\/00004728-199901000-00001","article-title":"Motion artefacts of the aorta simulating aortic dissection on spiral CT","volume":"23","author":"Quanadli","year":"1999","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.crad.2004.03.025_bib78","doi-asserted-by":"crossref","first-page":"309","DOI":"10.1148\/radiographics.20.2.g00mc04309","article-title":"Pitfalls in the diagnosis of thoracic aortic dissection at CT angiography","volume":"20","author":"Batra","year":"2000","journal-title":"RadioGraphics"},{"key":"10.1016\/j.crad.2004.03.025_bib79","doi-asserted-by":"crossref","first-page":"1497","DOI":"10.1007\/s00330-002-1388-0","article-title":"retrospectively ECGgated multislice spiral CT scan and reconstruction technique with suppression of heart pulsation artefacts for cardiothoracic imaging with extended volume coverage","volume":"12","author":"Flohr","year":"2002","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib80","doi-asserted-by":"crossref","first-page":"581","DOI":"10.1016\/S0009-9260(03)00188-0","article-title":"Refined computed tomography of the thoracic aorta: the impact of electrocardiographic assistance","volume":"58","author":"Morgan-Hughes","year":"2003","journal-title":"Clin Radiol"},{"key":"10.1016\/j.crad.2004.03.025_bib81","doi-asserted-by":"crossref","first-page":"583","DOI":"10.1148\/radiol.2282020873","article-title":"Thoracic aorta at multi-detector row CT: motion artefact with various reconstruction windows","volume":"228","author":"Morgan-Hughes","year":"2003","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2004.03.025_bib82","series-title":"Multi-slice CT in cardiac imaging","author":"Ohnesorge","year":"2002"}],"container-title":["Clinical Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009926004001606?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009926004001606?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,14]],"date-time":"2025-09-14T16:09:51Z","timestamp":1757866191000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0009926004001606"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2005,1]]},"references-count":82,"journal-issue":{"issue":"1","published-print":{"date-parts":[[2005,1]]}},"alternative-id":["S0009926004001606"],"URL":"https:\/\/doi.org\/10.1016\/j.crad.2004.03.025","relation":{},"ISSN":["0009-9260"],"issn-type":[{"value":"0009-9260","type":"print"}],"subject":[],"published":{"date-parts":[[2005,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Electrocardiographic assistance in multidetector CT of thoracic disorders","name":"articletitle","label":"Article Title"},{"value":"Clinical Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.crad.2004.03.025","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2005 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}