{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2025,10,20]],"date-time":"2025-10-20T10:07:39Z","timestamp":1760954859792,"version":"3.44.0"},"reference-count":23,"publisher":"Elsevier BV","issue":"6","license":[{"start":{"date-parts":[[2006,6,1]],"date-time":"2006-06-01T00:00:00Z","timestamp":1149120000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2006,6,1]],"date-time":"2006-06-01T00:00:00Z","timestamp":1149120000000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","clinicalradiologyonline.net","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Radiology"],"published-print":{"date-parts":[[2006,6]]},"DOI":"10.1016\/j.crad.2006.01.012","type":"journal-article","created":{"date-parts":[[2006,5,19]],"date-time":"2006-05-19T07:19:02Z","timestamp":1148023142000},"page":"483-494","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":19,"title":["CT colonography in a Korean population with a high residue diet: Comparison between wet and dry preparations"],"prefix":"10.1016","volume":"61","author":[{"given":"S.H.","family":"Kim","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"B.I.","family":"Choi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.K.","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.M.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"H.W.","family":"Eun","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"J.Y.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.H.","family":"Lee","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.J.","family":"Han","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.H.","family":"Choi","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"K.-S.","family":"Shin","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"key":"10.1016\/j.crad.2006.01.012_bib1","doi-asserted-by":"crossref","first-page":"126","DOI":"10.1136\/gut.47.1.126","article-title":"Diagnostic accuracy and interobserver agreement of CT colonography (virtual colonoscopy)","volume":"47","author":"Pescatore","year":"2000","journal-title":"Gut"},{"key":"10.1016\/j.crad.2006.01.012_bib2","doi-asserted-by":"crossref","first-page":"380","DOI":"10.1148\/radiol.2252011625","article-title":"CT colonography: multiobserver diagnostic performance","volume":"225","author":"McFarland","year":"2002","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib3","doi-asserted-by":"crossref","first-page":"685","DOI":"10.1148\/radiology.219.3.r01jn40685","article-title":"Colorectal neoplasia: performance characteristics of CT colonography for detection in 300 patients","volume":"219","author":"Yee","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib4","doi-asserted-by":"crossref","first-page":"2191","DOI":"10.1056\/NEJMoa031618","article-title":"Computed tomographic virtual colonoscopy to screen for colorectal neoplasia in asymptomatic adults","volume":"349","author":"Pickhardt","year":"2003","journal-title":"N Engl J Med"},{"key":"10.1016\/j.crad.2006.01.012_bib5","doi-asserted-by":"crossref","first-page":"459","DOI":"10.1148\/radiol.2302021422","article-title":"Colorectal neoplasia screening with CT colonography in average-risk asymptomatic subjects: community-based study","volume":"230","author":"Edwards","year":"2004","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib6","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1148\/radiol.2303021624","article-title":"Colorectal polyps and cancers in asymptomatic average-risk patients: evaluation with CT colonography","volume":"230","author":"Macari","year":"2004","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib7","doi-asserted-by":"crossref","first-page":"1145","DOI":"10.1111\/j.1572-0241.2004.30253.x","article-title":"Community-based screening by colonoscopy or computed tomographic colonography in asymptomatic average-risk subjects","volume":"99","author":"Scott","year":"2004","journal-title":"Am J Gastroenterol"},{"key":"10.1016\/j.crad.2006.01.012_bib8","doi-asserted-by":"crossref","first-page":"109","DOI":"10.1148\/radiol.2291020561","article-title":"Multi-detector row CT colonography: effect of collimation, pitch, and orientation on polyp detection in a human colectomy specimen","volume":"229","author":"Taylor","year":"2003","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib9","doi-asserted-by":"crossref","first-page":"753","DOI":"10.1148\/radiol.2283020928","article-title":"CT colonography: protocol optimization with multi-detector row CT\u2014study in an anthropomorphic colon phantom","volume":"228","author":"Wessling","year":"2003","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib10","doi-asserted-by":"crossref","first-page":"611","DOI":"10.1148\/radiol.2322031069","article-title":"CT colonography: feasibility of substantial dose reduction\u2014comparison of medium to very low doses in identical patients","volume":"232","author":"Van Gelder","year":"2004","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib11","doi-asserted-by":"crossref","first-page":"25","DOI":"10.1148\/radiol.2241011126","article-title":"CT colonography at different radiation dose levels: feasibility of dose reduction","volume":"224","author":"van Gelder","year":"2002","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib12","doi-asserted-by":"crossref","first-page":"274","DOI":"10.1148\/radiology.218.1.r01ja31274","article-title":"Effect of different bowel preparations on residual fluid at CT colonography","volume":"218","author":"Macari","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib13","doi-asserted-by":"crossref","first-page":"393","DOI":"10.1148\/radiol.2241011222","article-title":"Dietary fecal tagging as a cleansing method before CT colonography: initial results polyp detection and patient acceptance","volume":"224","author":"Lefere","year":"2002","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib14","doi-asserted-by":"crossref","first-page":"693","DOI":"10.1148\/radiology.219.3.r01jn22693","article-title":"CT colonography without cathartic preparation: feasibility study","volume":"219","author":"Callstrom","year":"2001","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2006.01.012_bib15","doi-asserted-by":"crossref","first-page":"276","DOI":"10.1016\/S0016-5107(98)70191-9","article-title":"Meta-analysis and cost comparison of polyethylene glycol lavage versus sodium phosphate for colonoscopy preparation","volume":"48","author":"Hsu","year":"1998","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.crad.2006.01.012_bib16","doi-asserted-by":"crossref","first-page":"103","DOI":"10.1111\/j.1440-1746.1996.tb00044.x","article-title":"Bowel preparation for colonoscopy: a randomized prospective trail comparing sodium phosphate and polyethylene glycol in a predominantly elderly population","volume":"11","author":"Thomson","year":"1996","journal-title":"J Gastroenterol Hepatol"},{"key":"10.1016\/j.crad.2006.01.012_bib17","doi-asserted-by":"crossref","first-page":"1223","DOI":"10.1007\/BF02258217","article-title":"Effectiveness of polyethylene glycol antegrade gut lavage bowel preparation for colonoscopy\u2014timing is the key!","volume":"41","author":"Church","year":"1998","journal-title":"Dis Colon Rectum"},{"key":"10.1016\/j.crad.2006.01.012_bib18","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1034\/j.1600-0455.2002.430312.x","article-title":"Bowel cleansing methods prior to CT colonography","volume":"43","author":"Ginnerup","year":"2002","journal-title":"Acta Radiol"},{"key":"10.1016\/j.crad.2006.01.012_bib19","first-page":"540","article-title":"Dietary fiber intake of Korean","volume":"26","author":"Kim","year":"1997","journal-title":"J Korean Soc Food Sci Nutr"},{"key":"10.1016\/j.crad.2006.01.012_bib20","doi-asserted-by":"crossref","first-page":"705","DOI":"10.1067\/mge.2001.119733","article-title":"Efficacy and safety of sodium phosphate tablets compared with PEG solution in colon cleansing: two identically designed, randomized, controlled, parallel group, multicenter phase III trials","volume":"54","author":"Kastenberg","year":"2001","journal-title":"Gastrointest Endosc"},{"key":"10.1016\/j.crad.2006.01.012_bib21","first-page":"422","article-title":"A randomized prospective trial comparing oral sodium phosphate with standard polyethylene glycol-based lavage solution (Golytely) in the preparation of patients for colonoscopy","volume":"85","author":"Vanner","year":"1990","journal-title":"Am J Gastroenterol"},{"key":"10.1016\/j.crad.2006.01.012_bib22","doi-asserted-by":"crossref","first-page":"689","DOI":"10.1007\/BF02054413","article-title":"Prospective, randomized, endoscopic blinded trial comparing precolonoscopy bowel cleansing methods","volume":"37","author":"Cohen","year":"1994","journal-title":"Dis Colon Rectum"},{"key":"10.1016\/j.crad.2006.01.012_bib23","doi-asserted-by":"crossref","first-page":"560","DOI":"10.1055\/s-2002-33207","article-title":"Two liters of polyethylene glycol-electrolyte lavage solution versus sodium phosphate as bowel cleansing regimen for colonoscopy: a prospective randomized controlled trial","volume":"34","author":"Poon","year":"2002","journal-title":"Endoscopy"}],"container-title":["Clinical Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009926006000481?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009926006000481?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,14]],"date-time":"2025-09-14T16:17:24Z","timestamp":1757866644000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0009926006000481"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2006,6]]},"references-count":23,"journal-issue":{"issue":"6","published-print":{"date-parts":[[2006,6]]}},"alternative-id":["S0009926006000481"],"URL":"https:\/\/doi.org\/10.1016\/j.crad.2006.01.012","relation":{},"ISSN":["0009-9260"],"issn-type":[{"type":"print","value":"0009-9260"}],"subject":[],"published":{"date-parts":[[2006,6]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"CT colonography in a Korean population with a high residue diet: Comparison between wet and dry preparations","name":"articletitle","label":"Article Title"},{"value":"Clinical Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.crad.2006.01.012","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"Copyright \u00a9 2006 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}