{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,3,18]],"date-time":"2026-03-18T05:00:54Z","timestamp":1773810054232,"version":"3.50.1"},"reference-count":21,"publisher":"Elsevier BV","issue":"5","license":[{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2022,5,1]],"date-time":"2022-05-01T00:00:00Z","timestamp":1651363200000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","clinicalradiologyonline.net","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Radiology"],"published-print":{"date-parts":[[2022,5]]},"DOI":"10.1016\/j.crad.2022.02.005","type":"journal-article","created":{"date-parts":[[2022,2,25]],"date-time":"2022-02-25T09:05:24Z","timestamp":1645779924000},"page":"e394-e399","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":21,"title":["Imaging-guided percutaneous transthoracic needle biopsy of nodules in the lung base: fluoroscopy CT versus cone-beam CT"],"prefix":"10.1016","volume":"77","author":[{"given":"Q.","family":"Ren","sequence":"first","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"Y.","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"M.","family":"Yan","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"C.","family":"Zheng","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"G.","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]},{"given":"X.","family":"Xia","sequence":"additional","affiliation":[],"role":[{"role":"author","vocabulary":"crossref"}]}],"member":"78","reference":[{"issue":"255","key":"10.1016\/j.crad.2022.02.005_bib1","first-page":"32","article-title":"Ultrasound and ct guided thoracic biopsy approaches\u2014effectiveness and complications","author":"Azrumelashvili","year":"2016","journal-title":"Georgian Med News"},{"key":"10.1016\/j.crad.2022.02.005_bib2","article-title":"Biopsy of lung lesions under CT control","author":"Marel","year":"2020","journal-title":"Biomed Pap Med Fac Univ Palacky Olomouc Czech Repub"},{"key":"10.1016\/j.crad.2022.02.005_bib3","series-title":"StatPearls. Treasure island","article-title":"Lung biopsy techniques and clinical significance","author":"Modi","year":"2021"},{"issue":"1","key":"10.1016\/j.crad.2022.02.005_bib4","doi-asserted-by":"crossref","first-page":"291","DOI":"10.1148\/radiol.13131265","article-title":"C-arm cone-beam CT-guided percutaneous transthoracic needle biopsy of lung nodules: clinical experience in 1108 patients","volume":"271","author":"Lee","year":"2014","journal-title":"Radiology"},{"issue":"9","key":"10.1016\/j.crad.2022.02.005_bib5","doi-asserted-by":"crossref","first-page":"2108","DOI":"10.1007\/s00330-010-1783-x","article-title":"Initial experience of percutaneous transthoracic needle biopsy of lung nodules using C-arm cone-beam CT systems","volume":"20","author":"Jin","year":"2010","journal-title":"Eur Radiol"},{"issue":"6","key":"10.1016\/j.crad.2022.02.005_bib6","doi-asserted-by":"crossref","first-page":"W400","DOI":"10.2214\/AJR.09.3963","article-title":"C-arm cone-beam CT-guided percutaneous transthoracic lung biopsy: usefulness in evaluation of small pulmonary nodules","volume":"195","author":"Hwang","year":"2010","journal-title":"AJR Am J Roentgenol"},{"issue":"6","key":"10.1016\/j.crad.2022.02.005_bib7","doi-asserted-by":"crossref","first-page":"799","DOI":"10.1016\/j.jvir.2008.02.018","article-title":"Three-dimensional C-arm cone-beam CT: applications in the interventional suite","volume":"19","author":"Wallace","year":"2008","journal-title":"J Vasc Interv Radiol"},{"issue":"6","key":"10.1016\/j.crad.2022.02.005_bib8","doi-asserted-by":"crossref","first-page":"470","DOI":"10.5152\/dir.2014.13463","article-title":"Clinical applications of the C-arm cone-beam CT-based 3D needle guidance system in performing percutaneous transthoracic needle biopsy of pulmonary lesions","volume":"20","author":"Jiao","year":"2014","journal-title":"Diagn Interv Radiol"},{"issue":"2","key":"10.1016\/j.crad.2022.02.005_bib9","doi-asserted-by":"crossref","first-page":"381","DOI":"10.1007\/s00330-015-3861-6","article-title":"Comparison of cone-beam CT-guided and CT fluoroscopy-guided transthoracic needle biopsy of lung nodules","volume":"26","author":"Rotolo","year":"2016","journal-title":"Eur Radiol"},{"issue":"2","key":"10.1016\/j.crad.2022.02.005_bib10","first-page":"336","article-title":"Computed tomography-guided lung biopsy: association between biopsy needle angle and pneumothorax development","volume":"8","author":"Kuriyama","year":"2018","journal-title":"Mol Clin Oncol"},{"issue":"7","key":"10.1016\/j.crad.2022.02.005_bib11","doi-asserted-by":"crossref","first-page":"878","DOI":"10.1001\/archinte.1981.00340070058013","article-title":"A clinical and roentgenographic correlation of diaphragmatic movement","volume":"141","author":"Williams","year":"1981","journal-title":"Arch Intern Med"},{"key":"10.1016\/j.crad.2022.02.005_bib12","doi-asserted-by":"crossref","DOI":"10.1111\/1754-9485.13279","article-title":"Computed tomography guided lung biopsy under general anaesthesia with apnoea: preliminary experience","author":"Deb","year":"2021","journal-title":"J Med Imaging Radiat Oncol"},{"key":"10.1016\/j.crad.2022.02.005_bib13","doi-asserted-by":"crossref","DOI":"10.1097\/RCT.0000000000001192","article-title":"Percutaneous transthoracic lung biopsy: optimizing yield and mitigating risk","author":"Azour","year":"2021","journal-title":"J Comput Assist Tomogr"},{"issue":"6","key":"10.1016\/j.crad.2022.02.005_bib14","doi-asserted-by":"crossref","first-page":"1414","DOI":"10.1007\/s00270-011-0302-z","article-title":"Pulmonary masses: initial results of cone-beam CT guidance with needle planning software for percutaneous lung biopsy","volume":"35","author":"Braak","year":"2012","journal-title":"Cardiovasc Intervent Radiol"},{"issue":"4","key":"10.1016\/j.crad.2022.02.005_bib15","doi-asserted-by":"crossref","first-page":"258","DOI":"10.1016\/j.tranon.2015.04.006","article-title":"Percutaneous transthoracic lung biopsy: comparison between C-arm cone-beam CT and conventional CT guidance","volume":"8","author":"Cheng","year":"2015","journal-title":"Transl Oncol"},{"issue":"7","key":"10.1016\/j.crad.2022.02.005_bib16","doi-asserted-by":"crossref","first-page":"1845","DOI":"10.1007\/s00330-015-3601-y","article-title":"Rapid needle-out patient-rollover approach after cone beam CT-guided lung biopsy: effect on pneumothorax rate in 1,191 consecutive patients","volume":"25","author":"Kim","year":"2015","journal-title":"Eur Radiol"},{"issue":"1","key":"10.1016\/j.crad.2022.02.005_bib17","doi-asserted-by":"crossref","first-page":"241","DOI":"10.1148\/radiol.2019181362","article-title":"Ultra-Low radiation dose CT fluoroscopy for percutaneous interventions: a porcine feasibility study","volume":"291","author":"Wagner","year":"2019","journal-title":"Radiology"},{"issue":"6","key":"10.1016\/j.crad.2022.02.005_bib18","doi-asserted-by":"crossref","first-page":"1612","DOI":"10.1378\/chest.09-0370","article-title":"CT fluoroscopy-guided biopsy of 1,000 pulmonary lesions performed with 20-gauge coaxial cutting needles: diagnostic yield and risk factors for diagnostic failure","volume":"136","author":"Hiraki","year":"2009","journal-title":"Chest"},{"issue":"5","key":"10.1016\/j.crad.2022.02.005_bib19","doi-asserted-by":"crossref","first-page":"872","DOI":"10.3348\/kjr.2018.19.5.872","article-title":"Cone-beam CT virtual navigation-guided percutaneous needle biopsy of suspicious pleural metastasis: a pilot study","volume":"19","author":"Lim","year":"2018","journal-title":"Korean J Radiol"},{"issue":"1014","key":"10.1016\/j.crad.2022.02.005_bib20","doi-asserted-by":"crossref","first-page":"e217","DOI":"10.1259\/bjr\/64727750","article-title":"Transthoracic fine-needle aspiration biopsy of the lungs using a C-arm cone-beam CT system: diagnostic accuracy and post-procedural complications","volume":"85","author":"Lee","year":"2012","journal-title":"Br J Radiol"},{"issue":"5","key":"10.1016\/j.crad.2022.02.005_bib21","doi-asserted-by":"crossref","first-page":"712","DOI":"10.1007\/s00270-019-02163-3","article-title":"Virtual guidance of percutaneous transthoracic needle biopsy with C-arm cone-beam CT: diagnostic accuracy, risk factors and effective radiation dose","volume":"42","author":"Fior","year":"2019","journal-title":"Cardiovasc Intervent Radiol"}],"container-title":["Clinical Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009926022000897?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009926022000897?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,9,14]],"date-time":"2025-09-14T16:46:04Z","timestamp":1757868364000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0009926022000897"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2022,5]]},"references-count":21,"journal-issue":{"issue":"5","published-print":{"date-parts":[[2022,5]]}},"alternative-id":["S0009926022000897"],"URL":"https:\/\/doi.org\/10.1016\/j.crad.2022.02.005","relation":{},"ISSN":["0009-9260"],"issn-type":[{"value":"0009-9260","type":"print"}],"subject":[],"published":{"date-parts":[[2022,5]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Imaging-guided percutaneous transthoracic needle biopsy of nodules in the lung base: fluoroscopy CT versus cone-beam CT","name":"articletitle","label":"Article Title"},{"value":"Clinical Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.crad.2022.02.005","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2022 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.","name":"copyright","label":"Copyright"}]}}