{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,6,25]],"date-time":"2026-06-25T06:49:59Z","timestamp":1782370199583,"version":"3.54.5"},"reference-count":55,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2025,1,1]],"date-time":"2025-01-01T00:00:00Z","timestamp":1735689600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalradiologyonline.net","clinicalkey.fr","clinicalkey.jp","clinicalkey.com.au","clinicalkey.es","clinicalkey.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Radiology"],"published-print":{"date-parts":[[2025,1]]},"DOI":"10.1016\/j.crad.2024.09.011","type":"journal-article","created":{"date-parts":[[2024,9,21]],"date-time":"2024-09-21T15:33:39Z","timestamp":1726932819000},"page":"106705","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":6,"special_numbering":"C","title":["Radiation dose reduction in pediatric computed tomography (CT) using deep convolutional neural network denoising"],"prefix":"10.1016","volume":"80","author":[{"ORCID":"https:\/\/orcid.org\/0000-0003-0163-0963","authenticated-orcid":false,"given":"K.K.","family":"Horst","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Z.","family":"Zhou","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-1432-5781","authenticated-orcid":false,"given":"N.C.","family":"Hull","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-0552-8571","authenticated-orcid":false,"given":"P.G.","family":"Thacker","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"B.A.","family":"Kassmeyer","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"M.P.","family":"Johnson","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-6358-1728","authenticated-orcid":false,"given":"N.","family":"Demirel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.D.","family":"Missert","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0009-0006-2294-5808","authenticated-orcid":false,"given":"K.","family":"Weger","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"L.","family":"Yu","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.crad.2024.09.011_bib1","doi-asserted-by":"crossref","first-page":"677","DOI":"10.1542\/peds.2007-1910","article-title":"American Academy of Pediatrics Section on R. Radiation risk to children from computed tomography","volume":"120","author":"Brody","year":"2007","journal-title":"Pediatrics"},{"key":"10.1016\/j.crad.2024.09.011_bib2","doi-asserted-by":"crossref","first-page":"603","DOI":"10.1016\/j.jpedsurg.2006.12.009","article-title":"Review of radiation risks from computed tomography: essentials for the pediatric surgeon","volume":"42","author":"Rice","year":"2007","journal-title":"J Pediatr Surg"},{"key":"10.1016\/j.crad.2024.09.011_bib3","doi-asserted-by":"crossref","first-page":"289","DOI":"10.2214\/ajr.176.2.1760289","article-title":"Estimated risks of radiation-induced fatal cancer from pediatric CT","volume":"176","author":"Brenner","year":"2001","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2024.09.011_bib4","doi-asserted-by":"crossref","first-page":"142","DOI":"10.1093\/rpd\/ncr293","article-title":"Patient doses in paediatric CT: feasibility of setting diagnostic reference levels","volume":"147","author":"Jarvinen","year":"2011","journal-title":"Radiat Prot Dosim"},{"key":"10.1016\/j.crad.2024.09.011_bib5","doi-asserted-by":"crossref","first-page":"307","DOI":"10.1093\/rpd\/nct226","article-title":"The establishment of computed tomography diagnostic reference levels in Portugal","volume":"158","author":"Santos","year":"2014","journal-title":"Radiat Prot Dosim"},{"key":"10.1016\/j.crad.2024.09.011_bib6","doi-asserted-by":"crossref","first-page":"219","DOI":"10.1148\/radiol.2017161530","article-title":"Pediatric chest CT diagnostic reference ranges: development and application","volume":"284","author":"Strauss","year":"2017","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2024.09.011_bib7","doi-asserted-by":"crossref","first-page":"214","DOI":"10.1093\/rpd\/ncab093","article-title":"Estimation of diagnostic reference levels and achievable doses for pediatric patients in common computed tomography examinations: a multi-center study","volume":"194","author":"Zamani","year":"2021","journal-title":"Radiat Prot Dosim"},{"key":"10.1016\/j.crad.2024.09.011_bib8","doi-asserted-by":"crossref","first-page":"92","DOI":"10.1016\/j.jped.2018.07.010","article-title":"Ultra-low-dose chest computed tomography without anesthesia in the assessment of pediatric pulmonary diseases","volume":"96","author":"Dorneles","year":"2020","journal-title":"J Pediatr (Rio J"},{"key":"10.1016\/j.crad.2024.09.011_bib9","doi-asserted-by":"crossref","first-page":"1072","DOI":"10.1007\/s00247-014-3245-0","article-title":"CT of the chest in suspected child abuse using submillisievert radiation dose","volume":"45","author":"Sanchez","year":"2015","journal-title":"Pediatr Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib10","doi-asserted-by":"crossref","first-page":"820","DOI":"10.1148\/radiol.10100278","article-title":"Development of low-dose protocols for thin-section CT assessment of cystic fibrosis in pediatric patients","volume":"257","author":"O'Connor","year":"2010","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2024.09.011_bib11","doi-asserted-by":"crossref","first-page":"991","DOI":"10.1007\/s10554-016-0854-8","article-title":"Diagnostic accuracy of sub-mSv prospective ECG-triggering cardiac CT in young infant with complex congenital heart disease","volume":"32","author":"Gao","year":"2016","journal-title":"Int J Cardiovasc Imaging"},{"key":"10.1016\/j.crad.2024.09.011_bib12","doi-asserted-by":"crossref","first-page":"1455","DOI":"10.1007\/s10554-020-02118-7","article-title":"Evaluation of complex congenital heart disease in infants using low dose cardiac computed tomography","volume":"37","author":"Dodge-Khatami","year":"2021","journal-title":"Int J Cardiovasc Imaging"},{"key":"10.1016\/j.crad.2024.09.011_bib13","doi-asserted-by":"crossref","first-page":"1678","DOI":"10.3390\/tomography8040140","article-title":"AI denoising improves image quality and radiological workflows in pediatric ultra-low-dose thorax computed tomography scans","volume":"8","author":"Brendlin","year":"2022","journal-title":"Tomography"},{"key":"10.1016\/j.crad.2024.09.011_bib14","doi-asserted-by":"crossref","first-page":"369","DOI":"10.1007\/s10140-017-1487-5","article-title":"Pediatric chest CT at chest radiograph doses: when is the ultralow-dose chest CT clinically appropriate?","volume":"24","author":"Villanueva-Meyer","year":"2017","journal-title":"Emerg Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib15","doi-asserted-by":"crossref","first-page":"1444","DOI":"10.2214\/AJR.21.26183","article-title":"Comparison of 0.3-mSv CT to standard-dose CT for detection of lung nodules in children and young adults with cancer","volume":"217","author":"Thapaliya","year":"2021","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2024.09.011_bib16","doi-asserted-by":"crossref","first-page":"1057","DOI":"10.1007\/s00247-022-05584-4","article-title":"Low dose pediatric chest computed tomography on a photon counting detector system - initial clinical experience","volume":"53","author":"Tsiflikas","year":"2023","journal-title":"Pediatr Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib17","doi-asserted-by":"crossref","first-page":"1050","DOI":"10.1007\/s00261-015-0384-1","article-title":"Observer performance for adaptive, image-based denoising and filtered back projection compared to scanner-based iterative reconstruction for lower dose CT enterography","volume":"40","author":"Fletcher","year":"2015","journal-title":"Abdom Imaging"},{"key":"10.1016\/j.crad.2024.09.011_bib18","doi-asserted-by":"crossref","first-page":"455","DOI":"10.1148\/radiol.2018180125","article-title":"Observer performance with varying radiation dose and reconstruction methods for detection of hepatic metastases","volume":"289","author":"Fletcher","year":"2018","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2024.09.011_bib19","doi-asserted-by":"crossref","first-page":"1060","DOI":"10.1016\/j.crad.2017.07.006","article-title":"Image quality of CT angiography in young children with congenital heart disease: a comparison between the sinogram-affirmed iterative reconstruction (SAFIRE) and advanced modelled iterative reconstruction (ADMIRE) algorithms","volume":"72","author":"Nam","year":"2017","journal-title":"Clin Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib20","doi-asserted-by":"crossref","first-page":"242","DOI":"10.1007\/s00247-019-04532-z","article-title":"Pediatric head computed tomography with advanced modeled iterative reconstruction: focus on image quality and reduction of radiation dose","volume":"50","author":"Cho","year":"2020","journal-title":"Pediatr Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib21","doi-asserted-by":"crossref","first-page":"31","DOI":"10.1007\/s10554-014-0570-1","article-title":"Image quality of CT angiography with model-based iterative reconstruction in young children with congenital heart disease: comparison with filtered back projection and adaptive statistical iterative reconstruction","volume":"31","author":"Son","year":"2015","journal-title":"Int J Cardiovasc Imaging"},{"key":"10.1016\/j.crad.2024.09.011_bib22","doi-asserted-by":"crossref","first-page":"339","DOI":"10.1148\/radiol.2015132766","article-title":"State of the art: iterative CT reconstruction techniques","volume":"276","author":"Geyer","year":"2015","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2024.09.011_bib23","doi-asserted-by":"crossref","first-page":"499","DOI":"10.1148\/radiol.15142047","article-title":"Degradation of CT low-contrast spatial resolution due to the use of iterative reconstruction and reduced dose levels","volume":"276","author":"McCollough","year":"2015","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2024.09.011_bib24","first-page":"220311","article-title":"Photon-counting detector CT with deep learning noise reduction to detect multiple myeloma","author":"Baffour","year":"2022","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2024.09.011_bib25","doi-asserted-by":"crossref","DOI":"10.1088\/1361-6560\/ac7999","article-title":"Deep learning versus iterative reconstruction on image quality and dose reduction in abdominal CT: a live animal study","volume":"67","author":"Zhang","year":"2022","journal-title":"Phys Med Biol"},{"key":"10.1016\/j.crad.2024.09.011_bib26","doi-asserted-by":"crossref","first-page":"146","DOI":"10.1186\/s12880-021-00677-2","article-title":"Image quality assessment of pediatric chest and abdomen CT by deep learning reconstruction","volume":"21","author":"Yoon","year":"2021","journal-title":"BMC Med Imaging"},{"key":"10.1016\/j.crad.2024.09.011_bib27","article-title":"Denoising of pediatric low dose abdominal CT using deep learning based algorithm","volume":"17","author":"Park","year":"2022","journal-title":"PLoS One"},{"key":"10.1016\/j.crad.2024.09.011_bib28","doi-asserted-by":"crossref","first-page":"422","DOI":"10.1002\/mp.13918","article-title":"Synthesizing images from multiple kernels using a deep convolutional neural network","volume":"47","author":"Missert","year":"2020","journal-title":"Med Phys"},{"key":"10.1016\/j.crad.2024.09.011_bib29","doi-asserted-by":"crossref","first-page":"180","DOI":"10.1148\/radiol.2020202317","article-title":"Improving image quality and reducing radiation dose for pediatric CT by using deep learning reconstruction","volume":"298","author":"Brady","year":"2021","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2024.09.011_bib30","doi-asserted-by":"crossref","first-page":"315","DOI":"10.2214\/AJR.21.27255","article-title":"Radiation dose reduction for 80-kVp pediatric CT using deep learning-based reconstruction: a clinical and phantom study","volume":"219","author":"Nagayama","year":"2022","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2024.09.011_bib31","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20211163","article-title":"Radiation and iodine dose reduced thoraco-abdomino-pelvic dual-energy CT at 40 keV reconstructed with deep learning image reconstruction","volume":"95","author":"Noda","year":"2022","journal-title":"Br J Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib32","doi-asserted-by":"crossref","first-page":"1629","DOI":"10.1007\/s00330-022-09206-3","article-title":"Is it possible to use low-dose deep learning reconstruction for the detection of liver metastases on CT routinely?","volume":"33","author":"Lyu","year":"2023","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib33","doi-asserted-by":"crossref","DOI":"10.3390\/cancers14205016","article-title":"Measurement accuracy and repeatability of RECIST-defined pulmonary lesions and lymph nodes in ultra-low-dose CT based on deep learning image reconstruction","volume":"14","author":"Zhao","year":"2022","journal-title":"Cancers (Basel)"},{"key":"10.1016\/j.crad.2024.09.011_bib34","doi-asserted-by":"crossref","DOI":"10.1259\/bjr.20220196","article-title":"Iterative reconstruction vs deep learning image reconstruction: comparison of image quality and diagnostic accuracy of arterial stenosis in low-dose lower extremity CT angiography","volume":"95","author":"Qu","year":"2022","journal-title":"Br J Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib35","doi-asserted-by":"crossref","first-page":"477","DOI":"10.1097\/RCT.0b013e318258e891","article-title":"Development and validation of a practical lower-dose-simulation tool for optimizing computed tomography scan protocols","volume":"36","author":"Yu","year":"2012","journal-title":"J Comput Assist Tomogr"},{"key":"10.1016\/j.crad.2024.09.011_bib36","doi-asserted-by":"crossref","first-page":"e339","DOI":"10.1002\/mp.12345","article-title":"Low-dose CT for the detection and classification of metastatic liver lesions: results of the 2016 low dose CT Grand Challenge","volume":"44","author":"McCollough","year":"2017","journal-title":"Med Phys"},{"key":"10.1016\/j.crad.2024.09.011_bib37","doi-asserted-by":"crossref","first-page":"465","DOI":"10.1148\/radiol.2015141991","article-title":"Observer performance in the detection and classification of malignant hepatic nodules and masses with CT image-space denoising and iterative reconstruction","volume":"276","author":"Fletcher","year":"2015","journal-title":"Radiology"},{"key":"10.1016\/j.crad.2024.09.011_bib38","doi-asserted-by":"crossref","first-page":"73","DOI":"10.2214\/AJR.22.27806","article-title":"Diagnostic performance in low- and high-contrast tasks of an image-based denoising algorithm applied to radiation dose-reduced multiphase abdominal CT examinations","volume":"220","author":"Inoue","year":"2023","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2024.09.011_bib39","doi-asserted-by":"crossref","first-page":"1026","DOI":"10.2214\/AJR.14.14185","article-title":"Radiation dose reduction in pediatric body CT using iterative reconstruction and a novel image-based denoising method","volume":"205","author":"Yu","year":"2015","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2024.09.011_bib40","doi-asserted-by":"crossref","first-page":"902","DOI":"10.1002\/mp.14594","article-title":"Low-dose CT image and projection dataset","volume":"48","author":"Moen","year":"2021","journal-title":"Med Phys"},{"key":"10.1016\/j.crad.2024.09.011_bib41","doi-asserted-by":"crossref","first-page":"145","DOI":"10.1007\/s00256-021-03828-2","article-title":"Clinical evaluation of a phantom-based deep convolutional neural network for whole-body-low-dose and ultra-low-dose CT skeletal surveys","volume":"51","author":"Huber","year":"2022","journal-title":"Skeletal Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib42","volume":"vol. 33","author":"Landis","year":"1977"},{"key":"10.1016\/j.crad.2024.09.011_bib43","doi-asserted-by":"crossref","first-page":"1049","DOI":"10.1007\/s00247-022-05574-6","article-title":"Pilot study to determine whether reduced-dose photon-counting detector chest computed tomography can reliably display Brody II score imaging findings for children with cystic fibrosis at radiation doses that approximate radiographs","volume":"53","author":"Horst","year":"2023","journal-title":"Pediatr Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib44","series-title":"Report No 96. College park, MD","article-title":"Report No. 96. The measurement, reporting, and management of radiation dose in CT","author":"McCollough","year":"2008"},{"key":"10.1016\/j.crad.2024.09.011_bib45","doi-asserted-by":"crossref","first-page":"212","DOI":"10.1097\/HP.0000000000001302","article-title":"Evaluation of radiation doses in pediatric patients undergoing conventional chest X-ray examination","volume":"120","author":"Lahham","year":"2021","journal-title":"Health Phys"},{"key":"10.1016\/j.crad.2024.09.011_bib46","series-title":"Doses and radiation risk of the chest x-ray examination of children with COVID-19","author":"Shatskiy","year":"2021"},{"key":"10.1016\/j.crad.2024.09.011_bib47","doi-asserted-by":"crossref","first-page":"285","DOI":"10.1259\/bjr\/55733882","article-title":"What are the risks from medical X-rays and other low dose radiation?","volume":"79","author":"Wall","year":"2006","journal-title":"Br J Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib48","doi-asserted-by":"crossref","DOI":"10.1183\/16000617.0173-2021","article-title":"State-of-the-art review of lung imaging in cystic fibrosis with recommendations for pulmonologists and radiologists from the \"iMAging managEment of cySTic fibROsis\u201d (MAESTRO) consortium","volume":"31","author":"Ciet","year":"2022","journal-title":"Eur Respir Rev"},{"key":"10.1016\/j.crad.2024.09.011_bib49","doi-asserted-by":"crossref","first-page":"5139","DOI":"10.1007\/s00330-020-07537-7","article-title":"Image quality of ultralow-dose chest CT using deep learning techniques: potential superiority of vendor-agnostic post-processing over vendor-specific techniques","volume":"31","author":"Nam","year":"2021","journal-title":"Eur Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib50","doi-asserted-by":"crossref","first-page":"566","DOI":"10.2214\/AJR.19.21809","article-title":"Image quality and lesion detection on deep learning reconstruction and iterative reconstruction of submillisievert chest and abdominal CT","volume":"214","author":"Singh","year":"2020","journal-title":"AJR Am J Roentgenol"},{"key":"10.1016\/j.crad.2024.09.011_bib51","doi-asserted-by":"crossref","first-page":"100","DOI":"10.1016\/j.ejrad.2018.07.015","article-title":"Effects of reconstruction technique on the quality of abdominal CT angiography: a comparison between forward projected model-based iterative reconstruction solution (FIRST) and conventional reconstruction methods","volume":"106","author":"Wu","year":"2018","journal-title":"Eur J Radiol"},{"key":"10.1016\/j.crad.2024.09.011_bib52","doi-asserted-by":"crossref","first-page":"749","DOI":"10.1055\/s-0033-1335577","article-title":"Impact of a 4th generation iterative reconstruction technique on image quality in low-dose computed tomography of the chest in immunocompromised patients","volume":"185","author":"Laqmani","year":"2013","journal-title":"Rofo"},{"key":"10.1016\/j.crad.2024.09.011_bib53","doi-asserted-by":"crossref","first-page":"101","DOI":"10.1007\/s00062-018-0740-y","article-title":"Image quality of CT angiography of supra-aortic arteries : comparison between Advanced Modelled Iterative Reconstruction (ADMIRE), Sinogram Affirmed Iterative Reconstruction (SAFIRE) and Filtered Back Projection (FBP) in one patients' group","volume":"30","author":"Orgel","year":"2020","journal-title":"Clin Neuroradiol"},{"key":"10.1016\/j.crad.2024.09.011_bib54","doi-asserted-by":"crossref","first-page":"836","DOI":"10.1002\/mp.15430","article-title":"Performance of a deep learning-based CT image denoising method: generalizability over dose, reconstruction kernel, and slice thickness","volume":"49","author":"Zeng","year":"2022","journal-title":"Med Phys"},{"key":"10.1016\/j.crad.2024.09.011_bib55","doi-asserted-by":"crossref","first-page":"544","DOI":"10.1097\/RCT.0000000000001150","article-title":"Evaluating a convolutional neural network noise reduction method when applied to CT images reconstructed differently than training data","volume":"45","author":"Huber","year":"2021","journal-title":"J Comput Assist Tomogr"}],"container-title":["Clinical Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009926024005166?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009926024005166?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2025,2,19]],"date-time":"2025-02-19T17:44:17Z","timestamp":1739987057000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0009926024005166"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2025,1]]},"references-count":55,"alternative-id":["S0009926024005166"],"URL":"https:\/\/doi.org\/10.1016\/j.crad.2024.09.011","relation":{},"ISSN":["0009-9260"],"issn-type":[{"value":"0009-9260","type":"print"}],"subject":[],"published":{"date-parts":[[2025,1]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Radiation dose reduction in pediatric computed tomography (CT) using deep convolutional neural network denoising","name":"articletitle","label":"Article Title"},{"value":"Clinical Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.crad.2024.09.011","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 The Royal College of Radiologists. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"106705"}}