{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,9,28]],"date-time":"2026-09-28T18:46:16Z","timestamp":1790621176282,"version":"4.1.0"},"reference-count":28,"publisher":"Elsevier BV","license":[{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2026,8,1]],"date-time":"2026-08-01T00:00:00Z","timestamp":1785542400000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"}],"content-domain":{"domain":["clinicalkey.com","clinicalkey.com.au","clinicalkey.es","clinicalkey.fr","clinicalkey.jp","clinicalradiologyonline.net","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Clinical Radiology"],"published-print":{"date-parts":[[2026,8]]},"DOI":"10.1016\/j.crad.2026.107402","type":"journal-article","created":{"date-parts":[[2026,5,29]],"date-time":"2026-05-29T06:43:11Z","timestamp":1780036991000},"page":"107402","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":1,"special_numbering":"C","title":["Diagnostic accuracy of flat panel computed tomography for acute stroke: a systematic review and meta-analysis of diagnostic test accuracy studies"],"prefix":"10.1016","volume":"99","author":[{"ORCID":"https:\/\/orcid.org\/0000-0001-5629-3023","authenticated-orcid":false,"given":"S.","family":"Ghozy","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"S.B.","family":"Jazayeri","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0001-8142-8073","authenticated-orcid":false,"given":"M.A.","family":"Ali","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0003-4495-7464","authenticated-orcid":false,"given":"J.","family":"Ognard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"ORCID":"https:\/\/orcid.org\/0000-0002-9140-2325","authenticated-orcid":false,"given":"R.R.","family":"Borkar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"A.A.","family":"Dmytriw","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"R.","family":"Kadirvel","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"W.","family":"Brinjikji","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"D.F.","family":"Kallmes","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"issue":"7","key":"10.1016\/j.crad.2026.107402_bib1","doi-asserted-by":"crossref","first-page":"e364","DOI":"10.1161\/STR.0000000000000375","article-title":"2021 guideline for the prevention of stroke in patients with stroke and transient ischemic attack: a guideline from the American Heart Association\/American Stroke Association","volume":"52","author":"Kleindorfer","year":"2021","journal-title":"Stroke"},{"issue":"1","key":"10.1016\/j.crad.2026.107402_bib2","doi-asserted-by":"crossref","DOI":"10.1136\/bmjmed-2022-000407","article-title":"Advances in mechanical thrombectomy for acute ischaemic stroke","volume":"2","author":"Raha","year":"2023","journal-title":"BMJ Med"},{"issue":"8","key":"10.1016\/j.crad.2026.107402_bib3","doi-asserted-by":"crossref","first-page":"2478","DOI":"10.1161\/STROKEAHA.121.038221","article-title":"Direct to angiosuite versus conventional imaging in suspected large vessel occlusion: a systemic review and meta-analysis","volume":"53","author":"Mohammaden","year":"2022","journal-title":"Stroke"},{"issue":"8","key":"10.1016\/j.crad.2026.107402_bib4","doi-asserted-by":"crossref","first-page":"1470","DOI":"10.3174\/ajnr.A2088","article-title":"Flat panel detector CT, CT angiography, and CT perfusion in stroke","volume":"31","author":"L\u00f6vblad","year":"2010","journal-title":"AJNR Am J Neuroradiol"},{"issue":"12","key":"10.1016\/j.crad.2026.107402_bib5","doi-asserted-by":"crossref","first-page":"1253","DOI":"10.1136\/neurintsurg-2016-012866","article-title":"Latest generation of flat detector CT as a peri-interventional diagnostic tool: a comparative study with multidetector CT","volume":"9","author":"Leyhe","year":"2017","journal-title":"J Neurointerv Surg"},{"issue":"1","key":"10.1016\/j.crad.2026.107402_bib6","doi-asserted-by":"crossref","first-page":"5","DOI":"10.1186\/s41747-023-00412-2","article-title":"Sine spin flat detector CT can improve cerebral soft tissue imaging: a retrospective in vivo study","volume":"8","author":"Schmitt","year":"2024","journal-title":"Eur Radiol Exp"},{"issue":"1","key":"10.1016\/j.crad.2026.107402_bib7","article-title":"Mechanical thrombectomy in the late presentation of anterior circulation large vessel occlusion stroke: a guideline from the society of vascular and interventional neurology guidelines and practice standards committee","volume":"3","author":"Nguyen","year":"2023","journal-title":"Stroke Vasc Interv Neurol"},{"key":"10.1016\/j.crad.2026.107402_bib8","article-title":"Preferred reporting items for systematic review and meta-analysis of diagnostic test accuracy studies (PRISMA-DTA): explanation, elaboration, and checklist","volume":"370","author":"Salameh","year":"2020","journal-title":"BMJ"},{"issue":"8","key":"10.1016\/j.crad.2026.107402_bib9","doi-asserted-by":"crossref","first-page":"529","DOI":"10.7326\/0003-4819-155-8-201110180-00009","article-title":"QUADAS-2: a revised tool for the quality assessment of diagnostic accuracy studies","volume":"155","author":"Whiting","year":"2011","journal-title":"Ann Intern Med"},{"issue":"3","key":"10.1016\/j.crad.2026.107402_bib10","first-page":"40","article-title":"Meta: an R package for meta-analysis","volume":"7","author":"Schwarzer","year":"2007","journal-title":"R News"},{"key":"10.1016\/j.crad.2026.107402_bib11","article-title":"Diagnostic test accuracy: application and practice using R software","volume":"41","author":"Shim","year":"2019","journal-title":"Epidemiol Health"},{"key":"10.1016\/j.crad.2026.107402_bib12","series-title":"Cochrane handbook for systematic reviews of interventions","author":"Chandler","year":"2019"},{"issue":"2","key":"10.1016\/j.crad.2026.107402_bib13","doi-asserted-by":"crossref","first-page":"112","DOI":"10.1002\/jrsm.11","article-title":"Outlier and influence diagnostics for meta-analysis","volume":"1","author":"Viechtbauer","year":"2010","journal-title":"Res Synth Methods"},{"issue":"1","key":"10.1016\/j.crad.2026.107402_bib14","doi-asserted-by":"crossref","first-page":"306","DOI":"10.1186\/s12874-022-01788-2","article-title":"Meta-DiSc 2.0: a web application for meta-analysis of diagnostic test accuracy data","volume":"22","author":"Plana","year":"2022","journal-title":"BMC Med Res Methodol"},{"issue":"7109","key":"10.1016\/j.crad.2026.107402_bib15","doi-asserted-by":"crossref","first-page":"629","DOI":"10.1136\/bmj.315.7109.629","article-title":"Bias in meta-analysis detected by a simple, graphical test","volume":"315","author":"Egger","year":"1997","journal-title":"Bmj"},{"issue":"3","key":"10.1016\/j.crad.2026.107402_bib16","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1111\/jon.13098","article-title":"Flat-panel detector CT to assess intracranial hemorrhage immediately following mechanical thrombectomy","volume":"33","author":"Inoa","year":"2023","journal-title":"J Neuroimaging"},{"issue":"1\u20132","key":"10.1016\/j.crad.2026.107402_bib17","doi-asserted-by":"crossref","first-page":"9","DOI":"10.1159\/000450727","article-title":"Optimized flat-detector CT in stroke imaging: ready for first-line use?","volume":"43","author":"Eckert","year":"2017","journal-title":"Cerebrovasc Dis"},{"issue":"4","key":"10.1016\/j.crad.2026.107402_bib18","doi-asserted-by":"crossref","first-page":"1600","DOI":"10.1177\/02841851221122429","article-title":"Immediate postinterventional flat-panel CT: differentiation of hemorrhagic transformation from contrast exudation of acute ischemic stroke patients after thrombectomy","volume":"64","author":"Pan","year":"2023","journal-title":"Acta Radiol"},{"issue":"2","key":"10.1016\/j.crad.2026.107402_bib19","doi-asserted-by":"crossref","first-page":"139","DOI":"10.1136\/neurintsurg-2012-010644","article-title":"Predictive value of flat-panel CT for haemorrhagic transformations in patients with acute stroke treated with thrombectomy","volume":"6","author":"Rouchaud","year":"2014","journal-title":"J Neurointerv Surg"},{"issue":"9","key":"10.1016\/j.crad.2026.107402_bib20","doi-asserted-by":"crossref","first-page":"1759","DOI":"10.3174\/ajnr.A4021","article-title":"Flat detector angio-CT following intra-arterial therapy of acute ischemic stroke: identification of hemorrhage and distinction from contrast accumulation due to blood-brain barrier disruption","volume":"35","author":"Kau","year":"2014","journal-title":"AJNR Am J Neuroradiol"},{"issue":"6","key":"10.1016\/j.crad.2026.107402_bib21","doi-asserted-by":"crossref","first-page":"541","DOI":"10.1007\/s00234-017-1837-8","article-title":"Standards of practice in interventional neuroradiology","volume":"59","author":"Jansen","year":"2017","journal-title":"Neuroradiology"},{"key":"10.1016\/j.crad.2026.107402_bib22","doi-asserted-by":"crossref","DOI":"10.1016\/j.jocn.2025.111110","article-title":"Direct transfer to angiosuite vs conventional workup for stroke: a systematic review and meta-analysis","volume":"134","author":"Mortezaei","year":"2025","journal-title":"J Clin Neurosci"},{"issue":"3","key":"10.1016\/j.crad.2026.107402_bib23","doi-asserted-by":"crossref","DOI":"10.3390\/jcm14030963","article-title":"Hybrid CT angio suite for acute ischemic stroke: a new time-saving workflow model?","volume":"14","author":"Trombatore","year":"2025","journal-title":"J Clin Med"},{"issue":"11","key":"10.1016\/j.crad.2026.107402_bib24","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0165794","article-title":"Voxel-based sensitivity of flat-panel CT for the detection of intracranial hemorrhage: comparison to multi-detector CT","volume":"11","author":"Fr\u00f6lich","year":"2016","journal-title":"PLoS One"},{"issue":"3","key":"10.1016\/j.crad.2026.107402_bib25","doi-asserted-by":"crossref","first-page":"625","DOI":"10.1007\/s00062-024-01401-7","article-title":"Flat-panel detector perfusion imaging and conventional multidetector perfusion imaging in patients with acute ischemic stroke : a comparative study","volume":"34","author":"Serrallach","year":"2024","journal-title":"Clin Neuroradiol"},{"issue":"2","key":"10.1016\/j.crad.2026.107402_bib26","doi-asserted-by":"crossref","first-page":"163","DOI":"10.3174\/ajnr.A8103","article-title":"Value of immediate flat panel perfusion imaging after endovascular therapy (AFTERMATH): a proof of concept study","volume":"45","author":"Mujanovic","year":"2024","journal-title":"AJNR Am J Neuroradiol"},{"issue":"12","key":"10.1016\/j.crad.2026.107402_bib27","doi-asserted-by":"crossref","first-page":"1457","DOI":"10.1007\/s00234-019-02285-y","article-title":"Diagnostic accuracy of flat-panel computed tomography in assessing cerebral perfusion in comparison with perfusion computed tomography and perfusion magnetic resonance: a systematic review","volume":"61","author":"Stille","year":"2019","journal-title":"Neuroradiology"},{"issue":"4","key":"10.1016\/j.crad.2026.107402_bib28","doi-asserted-by":"crossref","first-page":"387","DOI":"10.1136\/neurintsurg-2021-018464","article-title":"Evaluation of time-resolved whole brain flat panel detector perfusion imaging using RAPID ANGIO in patients with acute stroke: comparison with CT perfusion imaging","volume":"15","author":"Kurmann","year":"2023","journal-title":"J Neurointerv Surg"}],"container-title":["Clinical Radiology"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009926026001789?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S0009926026001789?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2026,9,8]],"date-time":"2026-09-08T00:26:54Z","timestamp":1788827214000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S0009926026001789"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2026,8]]},"references-count":28,"alternative-id":["S0009926026001789"],"URL":"https:\/\/doi.org\/10.1016\/j.crad.2026.107402","relation":{},"ISSN":["0009-9260"],"issn-type":[{"value":"0009-9260","type":"print"}],"subject":[],"published":{"date-parts":[[2026,8]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Diagnostic accuracy of flat panel computed tomography for acute stroke: a systematic review and meta-analysis of diagnostic test accuracy studies","name":"articletitle","label":"Article Title"},{"value":"Clinical Radiology","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.crad.2026.107402","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2026 The Royal College of Radiologists. Published by Elsevier Ltd. All rights are reserved, including those for text and data mining, AI training, and similar technologies.","name":"copyright","label":"Copyright"}],"article-number":"107402"}}