{"status":"ok","message-type":"work","message-version":"1.0.0","message":{"indexed":{"date-parts":[[2026,11,7]],"date-time":"2026-11-07T09:45:40Z","timestamp":1794044740728,"version":"4.8.0"},"reference-count":31,"publisher":"Elsevier BV","issue":"2","license":[{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/tdm\/userlicense\/1.0\/"},{"start":{"date-parts":[[2024,4,1]],"date-time":"2024-04-01T00:00:00Z","timestamp":1711929600000},"content-version":"tdm","delay-in-days":0,"URL":"https:\/\/www.elsevier.com\/legal\/tdmrep-license"},{"start":{"date-parts":[[2024,2,8]],"date-time":"2024-02-08T00:00:00Z","timestamp":1707350400000},"content-version":"vor","delay-in-days":0,"URL":"http:\/\/creativecommons.org\/licenses\/by-nc-nd\/4.0\/"}],"funder":[{"DOI":"10.13039\/100006775","name":"GE Healthcare","doi-asserted-by":"publisher","id":[{"id":"10.13039\/100006775","id-type":"DOI","asserted-by":"publisher"}]}],"content-domain":{"domain":["cvdigitalhealthjournal.com","elsevier.com","sciencedirect.com"],"crossmark-restriction":true},"short-container-title":["Cardiovascular Digital Health Journal"],"published-print":{"date-parts":[[2024,4]]},"DOI":"10.1016\/j.cvdhj.2024.02.002","type":"journal-article","created":{"date-parts":[[2024,2,12]],"date-time":"2024-02-12T17:04:10Z","timestamp":1707757450000},"page":"70-77","update-policy":"https:\/\/doi.org\/10.1016\/elsevier_cm_policy","source":"Crossref","is-referenced-by-count":3,"title":["Performance comparison of 6 in-hospital patient monitoring systems in the detection and alarm of ventricular cardiac arrhythmias"],"prefix":"10.1016","volume":"5","author":[{"given":"Nicola","family":"Cosentino","sequence":"first","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Xuan","family":"Zhang","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Emily J.","family":"Farrar","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Halit O.","family":"Yapici","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Ren\u00e9","family":"Coffeng","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"Heikki","family":"Vaananen","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]},{"given":"John W.","family":"Beard","sequence":"additional","affiliation":[],"role":[{"vocabulary":"crossref","role":"author"}]}],"member":"78","reference":[{"key":"10.1016\/j.cvdhj.2024.02.002_bib1","doi-asserted-by":"crossref","first-page":"764","DOI":"10.1213\/00000539-199211000-00020","article-title":"A comparison of methods for the detection of myocardial ischemia during noncardiac surgery: automated ST-segment analysis systems, electrocardiography, and transesophageal echocardiography","volume":"75","author":"Ellis","year":"1992","journal-title":"Anesth Analg"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib2","doi-asserted-by":"crossref","DOI":"10.1371\/journal.pone.0110274","article-title":"Insights into the problem of alarm fatigue with physiologic monitor devices: a comprehensive observational study of consecutive intensive care unit patients","volume":"9","author":"Drew","year":"2014","journal-title":"PLoS One"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib3","doi-asserted-by":"crossref","first-page":"2534","DOI":"10.1161\/CIRCULATIONAHA.106.180199","volume":"114","author":"Buxton","year":"2006","journal-title":"Circulation"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib4","doi-asserted-by":"crossref","first-page":"1671","DOI":"10.1136\/heartjnl-2019-316192","article-title":"Management of ventricular tachycardia storm","volume":"107","author":"Junaid","year":"2021","journal-title":"Heart"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib5","doi-asserted-by":"crossref","first-page":"1724","DOI":"10.1016\/S0735-1097(98)00430-6","article-title":"Ventricular tachycardia during follow-up in patients resuscitated from ventricular fibrillation: experience from stored electrograms of implantable cardioverter-defibrillators","volume":"32","author":"R\u00fcppel","year":"1998","journal-title":"J Am Coll Cardiol"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib6","doi-asserted-by":"crossref","first-page":"499","DOI":"10.2147\/TCRM.S126191","article-title":"Patient characteristics associated with false arrhythmia alarms in intensive care","volume":"13","author":"Harris","year":"2017","journal-title":"Ther Clin Risk Manag"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib7","doi-asserted-by":"crossref","first-page":"4689","DOI":"10.1038\/s41598-022-07761-9","article-title":"A contrastive learning approach for ICU false arrhythmia alarm reduction","volume":"12","author":"Zhou","year":"2022","journal-title":"Sci Rep"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib8","doi-asserted-by":"crossref","first-page":"378","DOI":"10.4037\/NCI.0b013e3182a903f9","article-title":"Alarm fatigue: a patient safety concern","volume":"24","author":"Sendelbach","year":"2013","journal-title":"AACN Adv Crit Care"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib9","doi-asserted-by":"crossref","first-page":"28","DOI":"10.4037\/ajcc2010651","article-title":"Monitor alarm fatigue: standardizing use of physiological monitors and decreasing nuisance alarms","volume":"19","author":"Graham","year":"2010","journal-title":"Am J Crit Care"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib10","doi-asserted-by":"crossref","first-page":"8409","DOI":"10.3390\/ijerph17228409","article-title":"Impact of alarm fatigue on the work of nurses in an intensive care environment\u2014a systematic review","volume":"17","author":"Lewandowska","year":"2020","journal-title":"Int J Environ Res Public Health"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib11","doi-asserted-by":"crossref","first-page":"e273","DOI":"10.1161\/CIR.0000000000000527","article-title":"Update to practice standards for electrocardiographic monitoring in hospital settings: a scientific statement from the American Heart Association","volume":"136","author":"Sandau","year":"2017","journal-title":"Circulation"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib12","doi-asserted-by":"crossref","first-page":"463","DOI":"10.1016\/j.jelectrocard.2007.07.002","article-title":"Maximal increase in sensitivity with minimal loss of specificity for diagnosis of acute coronary occlusion achieved by sequentially adding leads from the 24-lead electrocardiogram to the orderly sequenced 12-lead electrocardiogram","volume":"40","author":"Perron","year":"2007","journal-title":"J Electrocardiol"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib13","doi-asserted-by":"crossref","first-page":"857","DOI":"10.1161\/01.CIR.87.3.857","article-title":"Signal-averaged electrocardiogram. Improved identification of patients with ventricular tachycardia using a 28-lead optimal array","volume":"87","author":"Ho","year":"1993","journal-title":"Circulation"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib14","doi-asserted-by":"crossref","first-page":"368","DOI":"10.1111\/j.1475-097X.2007.00761.x","article-title":"Detection of acute myocardial infarction using the 12-lead ECG plus inverted leads versus the 16-lead ECG (with additional posterior and right-sided chest electrodes)","volume":"27","author":"Tragardh","year":"2007","journal-title":"Clin Physiol Funct Imaging"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib15","doi-asserted-by":"crossref","first-page":"786","DOI":"10.1016\/S0196-0644(05)80792-9","article-title":"Assessing the diagnostic value of an ECG containing leads V4R, V8, and V9: the 15-lead ECG","volume":"22","author":"Zalenski","year":"1993","journal-title":"Ann Emerg Med"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib16","series-title":"Cohort Description for MADDEC\u2014Mass Data in Detection and Prevention of Serious Adverse Events in Cardiovascular Disease","year":"2018"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib17","doi-asserted-by":"crossref","DOI":"10.1136\/openhrt-2019-001007","article-title":"Left ventricular ejection fraction adds value over the GRACE score in prediction of 6-month mortality after ACS: the MADDEC study","volume":"6","author":"Syyli","year":"2019","journal-title":"Open Heart"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib18","doi-asserted-by":"crossref","first-page":"1186","DOI":"10.1088\/0967-3334\/37\/8\/1186","article-title":"Suppression of false arrhythmia alarms in the ICU: a machine learning approach","volume":"37","author":"Ansari","year":"2016","journal-title":"Physiol Meas"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib19","doi-asserted-by":"crossref","first-page":"e2","DOI":"10.1016\/j.hrthm.2019.03.002","article-title":"2019 HRS\/EHRA\/APHRS\/LAHRS expert consensus statement on catheter ablation of ventricular arrhythmias","volume":"17","author":"Cronin","year":"2020","journal-title":"Heart Rhythm"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib20","doi-asserted-by":"crossref","first-page":"1539","DOI":"10.1253\/circj.CJ-16-0183","article-title":"Clinical impact of ventricular tachycardia and\/or fibrillation during the acute phase of acute myocardial infarction on in-hospital and 5-year mortality rates in the percutaneous coronary intervention era","volume":"80","author":"Masuda","year":"2016","journal-title":"Circ J"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib21","doi-asserted-by":"crossref","first-page":"1779","DOI":"10.1001\/jama.2009.600","article-title":"Incidence of and outcomes associated with ventricular tachycardia or fibrillation in patients undergoing primary percutaneous coronary intervention","volume":"301","author":"Mehta","year":"2009","journal-title":"JAMA"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib22","doi-asserted-by":"crossref","first-page":"588","DOI":"10.1016\/j.jelectrocard.2012.08.050","article-title":"Clinical alarm hazards: a \u201ctop ten\u201d health technology safety concern","volume":"45","author":"Keller","year":"2012","journal-title":"J Electrocardiol"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib23","doi-asserted-by":"crossref","first-page":"396","DOI":"10.12788\/jhm.2918","article-title":"Physiologic monitor alarm rates at 5 children's hospitals","volume":"13","author":"Schondelmeyer","year":"2018","journal-title":"J Hosp Med"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib24","doi-asserted-by":"crossref","first-page":"703","DOI":"10.1542\/hpeds.2020-003509","article-title":"Physiologic monitor alarm burden and nurses' subjective workload in a children's hospital","volume":"11","author":"Rasooly","year":"2021","journal-title":"Hosp Pediatr"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib25","doi-asserted-by":"crossref","first-page":"36","DOI":"10.1109\/RBME.2018.2810957","article-title":"A review of signal processing techniques for electrocardiogram signal quality assessment","volume":"11","author":"Satija","year":"2018","journal-title":"IEEE Rev Biomed Eng"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib26","doi-asserted-by":"crossref","first-page":"88357","DOI":"10.1109\/ACCESS.2019.2926199","article-title":"Noise detection in electrocardiogram signals for intensive care unit patients","volume":"7","author":"Bashar","year":"2019","journal-title":"IEEE Access"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib28","doi-asserted-by":"crossref","first-page":"464","DOI":"10.1161\/01.CIR.79.2.464","article-title":"Instrumentation and practice standards for electrocardiographic monitoring in special care units. A report for health professionals by a Task Force of the Council on Clinical Cardiology, American Heart Association","volume":"79","author":"Mirvis","year":"1989","journal-title":"Circulation"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib29","doi-asserted-by":"crossref","first-page":"e1583","DOI":"10.1002\/hsr2.1583","article-title":"Correlation between professional quality of life and alarm fatigue symptoms among intensive care unit nurses","volume":"6","author":"Dehghan","year":"2023","journal-title":"Health Sci Rep"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib30","doi-asserted-by":"crossref","first-page":"130","DOI":"10.1097\/CCM.0000000000002803","article-title":"Technological distractions (part 2): a summary of approaches to manage clinical alarms with intent to reduce alarm fatigue","volume":"46","author":"Winters","year":"2018","journal-title":"Crit Care Med"},{"issue":"6S","key":"10.1016\/j.cvdhj.2024.02.002_bib31","doi-asserted-by":"crossref","first-page":"S44","DOI":"10.1016\/j.jelectrocard.2018.07.024","article-title":"A call to alarms: current state and future directions in the battle against alarm fatigue","volume":"51","author":"Hravnak","year":"2018","journal-title":"J Electrocardiol"},{"key":"10.1016\/j.cvdhj.2024.02.002_bib33","doi-asserted-by":"crossref","first-page":"47","DOI":"10.1097\/NCQ.0000000000000223","article-title":"Alarm fatigue: use of an evidence-based alarm management strategy","volume":"32","author":"Turmell","year":"2017","journal-title":"J Nurs Care Qual"}],"container-title":["Cardiovascular Digital Health Journal"],"original-title":[],"language":"en","link":[{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666693624000094?httpAccept=text\/xml","content-type":"text\/xml","content-version":"vor","intended-application":"text-mining"},{"URL":"https:\/\/api.elsevier.com\/content\/article\/PII:S2666693624000094?httpAccept=text\/plain","content-type":"text\/plain","content-version":"vor","intended-application":"text-mining"}],"deposited":{"date-parts":[[2024,4,15]],"date-time":"2024-04-15T08:03:13Z","timestamp":1713168193000},"score":1,"resource":{"primary":{"URL":"https:\/\/linkinghub.elsevier.com\/retrieve\/pii\/S2666693624000094"}},"subtitle":[],"short-title":[],"issued":{"date-parts":[[2024,4]]},"references-count":31,"journal-issue":{"issue":"2","published-print":{"date-parts":[[2024,4]]}},"alternative-id":["S2666693624000094"],"URL":"https:\/\/doi.org\/10.1016\/j.cvdhj.2024.02.002","relation":{},"ISSN":["2666-6936"],"issn-type":[{"value":"2666-6936","type":"print"}],"subject":[],"published":{"date-parts":[[2024,4]]},"assertion":[{"value":"Elsevier","name":"publisher","label":"This article is maintained by"},{"value":"Performance comparison of 6 in-hospital patient monitoring systems in the detection and alarm of ventricular cardiac arrhythmias","name":"articletitle","label":"Article Title"},{"value":"Cardiovascular Digital Health Journal","name":"journaltitle","label":"Journal Title"},{"value":"https:\/\/doi.org\/10.1016\/j.cvdhj.2024.02.002","name":"articlelink","label":"CrossRef DOI link to publisher maintained version"},{"value":"article","name":"content_type","label":"Content Type"},{"value":"\u00a9 2024 Heart Rhythm Society.","name":"copyright","label":"Copyright"}]}}